Laserfiche WebLink
1-1 /2" DW flex pipe <br />inside 4' containment <br />/ pipe <br />O <br />N <br />OO ` <br />LAKE <br />MINNETONKA <br />a <br />�- <br />18' <br />CO <br />2 <br />�_ <br />BROWN'S <br />Z <br />a <br />BAY <br />Q <br />0 <br />500-gallon <br />tank on 6'x8' ` <br />(� <br />/ <br />0.5 <br />I JJ <br />(� <br />/ Rf concrete slab <br />0 <br />LLJ <br />/0 <br />Q <br />m n� Oak <br />Mas°<C <br />gaa� e <br />Hose <br />L <br />4 <br />N <br />Q <br />Reel <br />Q \Aokls <br />\ <br />r' <br />5'6'1 t <br />n✓ <br />J Y <br />Rn <br />Lo y o <br />o co <br />jd <br />Sole 1/8' <br />� <br />U CJ <br />_ <br />66A P <br />O d <br />F+e <br />O <br />O � 0 <br />� <br />(h <br />2 v <br />V <br />O 41 <br />o r <br />a 5 <br />a <br />1. Installation shall comply with the Minnesota Uniform Fire Code. <br />2. Dispenser shall be located a minimum of 10 feet from building and property lines and <br />when the hose is fully extended the nozzle shall not be closer than 5 feet from building <br />openings. <br />I <br />LAKE 3. Install (1) AST 500 gallon double wall tank UL142. <br />M I N N ETON KA 4. Tank will be placed on an concrete pad supplied by owner. <br />5. AST does not need vehicle impact protection because it is a none drive area. <br />6. There shall be an emergency shut-off device located not closer than 20 feet and not <br />SMITH BAY <br />0�9 � <br />farther than 100 feet from the dispenser. Activation of the emergency shuit-off device shall <br />co o <br />shut down transfer of fuel to the dispenser. The emergency shut-off device shall be distinctly <br />'a 'o LO co = o <br />labeled EMERGENCY SHUT-OFF DEVICE. <br />'� z <br />` 7. There shall be provided not farther than 75 feet from the dispenser a portable fire <br />extinclusher of a minimum rating2TA-20:BC. The fire extinguisher shall be inspected annually <br />U M a) M <br />CU4- <br />Gauge by qualified personnel. <br />v m NU <br />8. Signs prohibiting smoking, shall be conspicuously posted within sight of tank and <br />o U) CU <br />4" E-vent dispenser, 9. AST's require normal and emergency vents, The normal vent shall terminate a <br />Im L Q <br />Overfill alarm minimum of 12 feet above the ground level and 5 feet from building openings and property <br />`- <br />Spill container 2" vent lines that can be built upon. <br />Fillrite Pump 10. Electrical equipment shall be installed in accordance with the Minnesota Electrical Code. <br />Ball Valve 11. AST shall be provided with lightning protection in accordance with National Fire <br />1-1/2" Ball <br />Solenoid Valve Valve 75' Hose Reel Protection Association Standard 780 (1994 ed.) <br />12. Install Fill-Rite transfer pump on top of tank equipment with anti-siphon device. (N/C <br />1-1/2" Flexible DW pipe solenoid valve) <br />inside 4" containment pipe 13. Pipe (1) 1-1/2" double wall flex piping inside a 4" containment pipe from pump location <br />4 <br />to dispense reel located by the dock. <br />13. All nozzles to have automatic shut-off, WY OF 01100 <br />Scale 1" = 4' SITE PLAN GRADING PLAN <br />A A PHOV D Fez 7om< <br />To reel at dock on shore C.1�MMOVE0 WITH R� � Ns <br />D-09535-A <br />EJ 01d VED <br />y _ �.'lw�s VA" C <br />