My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
re: plan review notes
Orono
>
Property Files
>
Street Address
>
T
>
Tonkawa Road
>
0645 Tonkawa Road - 05-117-23-33-0019
>
Correspondence
>
re: plan review notes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:14:01 PM
Creation date
5/28/2019 1:15:05 PM
Metadata
Fields
Template:
x Address Old
Address
0645 Tonkawa Rd
Document Type
Correspondence
PIN
0511723330019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Review Notes <br /> Address; 645 Tonkawa Road <br /> Project: Addition/Remodel <br /> Architect; Rafferty Rafferty Tollefson Architects <br /> Contractor; Diversified Construction <br /> Owner; Camp Teko <br /> Inspector; Lyle Oman <br /> Occupancy Classification; Dining area A-3 <br /> Office area; B <br /> Caretakers res. R-3 <br /> Construction type; VN <br /> Location on property; > 20 to property lines, no requirements <br /> Allowable floor area; <br /> A-3 2712/6000 =452 B 1404/8000 =.175 R-3 1794/8000 =.222 <br /> .452+.175+.222=.851 <1 O.K. <br /> Building height and number of stories; O.K. <br /> Occupancy requirements; <br /> -no occupancy separation required between B and A-3 <br /> -one hour occupancy separation required between R-3 and B and A-3 <br /> -existing walls not to be remodeled <br /> -bedroom replacement window must meet egress requirements <br /> Type of construction requirements; <br /> -type VN proposed -O.K. <br /> Exiting requirements; <br /> -occupant load- 1414 sq. ft. divided by 100 occupant load factor equals 14 occupants <br /> -min 1 exits required, 1 proposed <br /> -travel distance -O.K. <br /> Fire-resistive requirements; <br /> -shaft enclosure -1 hour required, One hour proposed <br /> Required corrections to plan; <br /> -bedroom replacement windows must meet egress requirements <br /> -walls within 2 feet of the front and sides of urinals and water closets shall have a <br /> smooth, hard nonabsorbent surface of portland cement, concrete, ceramic tile or other <br /> smooth nonabsorbent surface to a height of 4 feet <br /> -provide well access per the Mn. Dept. of Health well code division <br /> -mechanical permit required to relocate kiln <br /> -provide smoke detectors in residential area <br /> r02 Por'-5 Di4i" 12'z1- 0 Z <br />