Laserfiche WebLink
�o-�� <br /> � . � <br /> 0 0��;, <br /> �'�� - p��'�{ CITY of ORONO <br /> �..�y,•'�! ,.f�'1'.s � � . . <br /> +�, '�1?}.��. ,„�; .. ��v Municipal Offices � <br /> ;�,: , <br /> �.�'.�:t�`� G Street Address: �15o�'a49'y6o O Mailing Address: <br /> ��9xE8Hp4��' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: <br /> �4� 5 c:� }�:�1 � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYST'EM CONFORMITY (1-3): � <br /> �"CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the cunent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazadon requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is aot failing or an imminent threat to public health or safety. , <br /> 3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the cuaent Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �1 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> v Tank was last pumped �• <br /> Make sure septic tanks are aumped throueh manhole and not throueh white inspection pipes. This allows for the oroper <br /> cleanin¢ Keep water softner and iron filter dischar¢e out of septic svstem to prolon¢I�fe of dramfield. Ask pumaer to test <br /> alarm float to verifv alarm is still working in vour house The alarm warns owner that seatsge�s about to backua mto basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection nsers(4"dia.p�pe)must be mstalled in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : 7S <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: ��F,�(' �t� � oo�(S o�C, ��J�p .S(� �-, L <br /> � C� Sv�� 'LOo� - <br /> � \o-�-o� �'� � <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> No�c: In the e��ent that this inspection report is used to satisf} the reyuirements for a mortgagc or other transter of'properf�. be advised that this report dues <br /> nut guarantee or ccrtitj that an e�isting s��stem ���ill continue to function properh•. hut is• mcreh an �pinion of tlle adequac� of the s�stem U11CICf l'lll'lYlll <br /> �un�itiuns based un the avail�ble inlonnation. <br />