Laserfiche WebLink
��O���� � <br /> � . 1V' <br /> ; O ' <br /> O ��� <br /> ,, <br /> ��� V - � CITY of ORONO <br /> ,,..;,,.P,� , <br /> � `�? .�; �,,j.��� ,. ��C„ , Municipal Offices ' <br /> ;;,:?�,.. ,.,:,. ;. <br /> '�,L ! .•t .+;` t,t��G Street Address: �15a-a4 q—�bo O Mailing Address: <br /> '9�(�HQ�' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��s0 S�`G dQ�0 U� ��- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the cuaent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locadon,design and construction standards of the cuaent Orono <br /> Municipal Code but does meet the ttuee foot separation requuement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failiag or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITTON l5-7): �� <br /> �T mspection indicates: <br /> Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped '-7-1b�6`� ). <br /> Make sure septic tanks are pumped through manhole and not throueh white inspection piaes. This allows for the proper <br /> cleanins Keep water softner and iron filter dischar¢e out of septic svstem to prolon¢life of drain6eld. Ask pumper to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner that seatase is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident, <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: ��U� ,' St�}� �- ��^�C� I uo k �K <br /> � <br /> �-�Z�6 -o y �� ��� <br /> Da[e of Inspection Matt Bolterman - Septic System Inspector <br /> Not�: In the e��ent that this inspection report is used lo satistj� the rec1uirements f'or a mortga�e or other transfer of propert�. be advised that this repa��does <br /> nut ��uarantee ur eertitj th�t an e.�isting system �vill continue ro liinction properl��. but is mereh an opinion of the adequac� oF the s•stem uncler current <br /> �nn�itiun>based on the av�ilablc inl�nnation. <br />