Loading...
HomeMy WebLinkAbout2003-P06927 - mechanical CITY•OF ORON PERMIT � Permit Number: 27�D Kelley Parkway- PO Box 66 P06927 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Pernrits (952) 249-4600 Date Issued: 10/23/2003 SITE ADDRESS: 30 Orono Orchard Rd N Wayzata,NIN 55391 PID: 35-118-23-33-0010 DESCRIPTION: Proposed Use: Residenrial Pernut Class: General Pemut Type: Mechanical Permits Permit Sub-type(s): Heating Systems DETAILS: Approved per resolurion#: Sepazate pernuts required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 55.15 Valuation• $ 4,412.00 State Surcharge Fee: $ 2.21 Misc.Fee: $ 1.50 TOTAL FEE: $ 58.86 APPLICANT' Sedgwick Heating&Air Conditioning Inc. �WNER' James Murphy&Sandra Smith � 8910 Wentworth Avenue S � 30 Orono Orchard Rd N Minneapolis,MN 55420 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. \_� �-�C .��i APPLICANT PERMITEE SIGNATURE SUED BY SIGNATURE Couies: 1-File(Si�nitures Required), 1-Anplicant 1-Monthlv Renorts, 1-Assessin�, 1-Finance Page 1 , i�'_ 'C i /�� . �t . � ����� �' � � - � ��� � � � '�'� �t` � �� � _ � _ [ ;'; CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) :;;�; Crystal Bay, MN 55323 � � f '� x r _ , ., � !. GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. ����` ' 2. Permit cards will be sent by retum mail after a review is completed. PERMITS ARE NOT VALID UNTIL �'` YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. �. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, _� ,�`, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain -� ;'� �"�� calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. ,,x Data shall be presented on form provided. Identificatioi�of and specificatior_s fer water heatir.g equipme.^.t � shall also be provided. 4 4. When any new construction or remodeling is involved, a separate building permit must be obtained. � �" 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 4 � 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. ��. Please check one: New Addition Repair ./� Replace �"� ' ""' ,/ Residential Commercial =� , ^ JOB SITE: ,�1 d ��q� Zip:��� �J � ; Owner's Name: Telephone Number: �,�,�-�/7�_��.t/lo Mailing Addre ���-Z�,, City: Zip: , � Contractor's Name: Telephone Number: Mailing Address: � � City: Zip: E---�;� , ,; - r:.. . . ;"�u3, ;:: SYSTEM DESCRIPTION � ���$�j_;,,�„„ ,j , ; F' ' �!� . �lf';� — J i, '-�'Y'. HEATING SYSTEMS � � ' Quantity: � _ ' � ,, ' Make: ,� , . , ,. Model: ��G!/��J'D�4 �" -3 ,, Fuel: .��,�� Flue Size: j " � Input BTUs: �cJl�fj `'`�� Output BTUs: CFM: �,�; COOLING SYSTEMS Quantity: Make: Model: � ��� ` Tons: - H. Power `, .,w , , E ,, } >, � �� � � .. . . �':.,� ' 4 . . . 9# � x� � y `�' � ' �' , _ .: , . . .. . . � .. . . �d" .. .. . . .. . � . . . : • M . ' FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove - Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen E�aust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* ar Minimum Fee ($35.00) •�'S�J� ' x .0125 $ p��-�� (contract price) 2. State Surchar�e. ** Add the State Building Code Division Surcharge to each permit. x .0005 $ �,o� � or $.50, whichever is greater (contract price) 3. Postage and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ �'�`�� * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. ,'', The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signatur . / , Date: �� Approved By: Date: � i� 'cl� � H`� ING&AIRCO��I,���o. RESIDENTIAL HEATING DATA SHEET Cbr�ifort you can count or� JOB NAME: DATE ADDRESS: OUTDOOR TEMP: INDOOR TEMP: TEMP. DIFFERENCE: DESIGN TEMPERATURE DIFFERENCE MOVABLE GLASS WINDOWS SaE TRE 30 3' 40 4' 50 5' 60 6' �� 7�' 80 8' � 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 39 45 52 58 65 71 78 84 90 97 103 110 116 123 SINGLE GLASS W/STORM 21 25 28 31 35 38 42 45 49 52 56 59 66 � DOUBLE GLASS �- 28 32 37 41 46 50 55 60 64 69 73 78 82 87 DOUBLE GLASS W/STORM 16 19 21 24 27 29 32 35 37 40 42 45 50 SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH SLIDING GLASS DOORS FEET � � � 4'' � �' � � �� �' � � � 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 42 48 55 62 69 76 83 90 97 104 110 117 124 131 SINGLE GLASS W/STORM 22 26 29 33 37 40 44 48 51 55 59 62 70 DOU B LE G LAS S --� 29 34 39 43 48 53 58 63 67 72 77 82 87 91 DESiGN TEMPERATURE DIFFERENCE DOORS SnE TRE 30 35 40 45 50 55 60 65 70 75 80 8a` 90 9`' HEAT LOSS HEAT TRANSFER MULTIPLIER SOLID WOOD 31 36 41 46 51 56 62 67 72 77 82 87 92 97 SOLID WOOD"• 18 21 24 27 30 33 36 39 42 45 47 50 53 56 METAL URETHANE 23 27 30 34 38 42 45 49 53 57 60 64 68 72 METAL URETHANE"• 13 16 18 20 22 25 27 29 31 33 36 38 40 42 "Weatherstripped or Storm RUNNING FEET � "U CEILING HEIGHT X !L WALLS GROSS WALL = L�13 U WINDOWS & DOOR AREAS - NET WALL AREA � l �3 � SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL 30 35 40 45 50 55 60 65 70 75 80 85 90 95 FEET HEAT TRANSFER MULTIPLIER HEAT LOSS NOINSULATION 8 10 11 12 14 15 17 18 19 21 22 23 25 26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 8.5 R-13, 3-1/2" INSULATION --- 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 6.3 6.6 R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1/2" POLYSTYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4.7 4.9 5.2 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH ABOVE GRADE FEET 30 35 40 45 50 55 60 65 70 75 80 8.�` 90 �' HEAT LOSS HEAT TRANSFER MULTIPLIER NOINSULATION 16 18 21 23 26 28 31 33 36 38 41 44 4& 49 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.5 3.8 4.2 4.6 5.0 5.4 5.8 6.2 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.6 3.8 4.1 4.3 4.6 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH BELOW GRADE F ET � � � � � � � � �� �' � � � �' HEAT LOSS HEAT TRANSFER MUITiPLIER NOINSULATION 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.6 10.311.011.812.513.214.0 R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4 7.8 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL Heat Loss Subtotal from Page 1 ` � � DESIGN TEMPERATURE DIFFERENCE C E I LI N G S a E TR E 30 35 40 45 50 55 60 65 70 75 80 85 g0 g5 BTU H HEAT TRANSFER MULTIPLIER HEAT LOSS NO INSULATION 18 21 24 27 30 33 36 39 42 45 48 51 I �l 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5J 6.2 6.6 7.0 7.5 I 8.4 R-19, 6" INSULATION 1.6 1.9 2.1 2.4 �2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 5.0 R-30, 10" INSULATION 1.0 1.2 1.3 1.5 , 1.6 1.8 2.0 2.1 2.3 2.5 2.6 �28 i 3.1 R-38, 12"' INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.' 2.'' :2 2.5 FLOOR OVER AN SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET 30 35 40 45 50 55 60 65 7U 75 80 8.�` � 9`' HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 10 11 13 14 16 17 19 21 22 24 25 27 ZS 30 R-11, 3" INSULATION 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 R-19, 6"INSULATION 1.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4 a.7 4.9 R-30, 10"INSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 �3.0 3.? 3.3 3.5 SQU E DESIGN TEMPERATURE DIFFERENCE BTUH BASEMENT FLOOR E� 30 35 40 45 50 55 60 65 70 75 ' 80 85 i 90 � 95 HEAT TRANSFER MULTIPLIER HEAT LOSS BASEMENT FLOOR 0.8 1.0 1.1 1.3 1.4 1.5 � 1.7 1.8 2.0 2.1 2.2 2.1 !2,� 2,7 CONCRETE SLAB WITHOUT LINEAR DESIGN TEMPERATURE DIFFERENCE BTUH PERIMETER SYSTEM FOOT � � � � � � � � �� � � � I � � HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 37 41 45 49 53 57 61 65 69 73 77 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 31 33 35 I 37 39 2" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14J 15.8 16.8�17.8�18.9 20.0 CONCRETE SLAB LINEAR DESIGN TEMPERATURE DIFFERENCE BTUH WITH PERIMETER SYSTEM FOOT 30 35 40 45 50 55 60 65 70 75 80 8a` ! 90 � 9`' HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 57 67 76 86 95 105 114 124 133 143 152 162 '� 181 1" EDGE INSULATION 34 40 4& 52 57 63 69 74 80 86 91 97 1 109 2" EDGE INSULATION 28 33 37 42 47 � 51 56 61 65 70 75 79 84 89 An additional infiitration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per linear foot of crack. �"l_. �FLOOR SQ FT. x �CEILING HEIGHT = CUBIC Ff INFILTRATION/ -�- VENTILATION I�G� 0.40 x CUBIC Ff - 60 = (��CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 45 50 55 60 65 70 75 8� 8.5 90 �' HEAT LOSS HEATTRANSFER MULTIPLIER /S6� INFILTRATION 33 39 44 50 55 61 66 72 77 83 88 9a 105 MECHANICAL VENTILATION ' 33 39 44 50 55 61 66 72 77 83 88 I 94 99 105 �t((� HEAT LOSS SUBTOTAL �� 7�3 DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15°'0 (.151 R-7, 2" Flexible Blanket Insulation: ADD 10°�O 1.101 TOTALHEATLOSS NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. HL-841-L7 002344 Litho U.S.A. ATE TIME �/ CITY OF ORONO CALLED IN �� �`�?-� INSPECTION NOT E SCHEDULED /LM����,-s �i' 3C ,.��27 PERMIT NO. � COMPLETED ADDRESS_ �� �ic'c' �;. ���� �;;,�'C���.r<<�.�� OWNER CONTR. ��G jr/,r` �� TELEPHONE NO. ,. �' '^ � � DESCRIPTION -- i� `�� � 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING `- 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 BD. 12 WATER HOOK-UP 17 SITE INSPECTION 05 FI 14 SEWER HOOK-UP 06 PROGRESS � DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP ? 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATIOWREMOVAL Z OWNERICONTRACTOR TO MEET YOU:_YES_NO v�, COMMENTS: � W a � J O � � O � W � Q � 2 W � W � � � � �1 WORKSATISFACTORY:PROCEED ❑ PROJECTCOMPLEiE W ❑CORRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR flEINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (95Z� 249-46QQ OwnerlContra n i e: Inspector. - White Copy/lnspector's Fi Canary Copy/Site Notice SEDGWICK HEATING & AIR CONDITIONING CO. HEATING ,lOBNO. ��� � 8910 WENTWORTH AVENUE SOUTH • MINNEAPOLIS,MN 55420 • (952)881-9000 TEST RECORD ADDRESS v� O ``U N O Q K C�1/�� �l CITY �' v�� OCCUPANT OWNER ���� �-S ' " 'U���Y SOLD BY�`e�Q W� �� INSTALLED BY MAKE ��N � �x MODEL ��v��V J� Q 6 ( � SERIAL NO. INPUT_ (J���UJ ����� �{ `�, // THERMOSTAT �v `�v ' -� �� VENT SIZE � VALVE ��✓Lw / TYPE OF LINER j��� LIMIT F�tX2N � l� V��Y NO LINER SIZE LIMIT SETTING ��/V� FILTERS: SIZE J��O v NUMBER .�, � FAN SETTING !� WIRING �U/�dst����!(j PILOT TYPE L/��-/ �^a���C TEST TAG IGNITION MODEL V(041��SCCs LIGHTING INST. t / PILOT TIMING —L '�S 4 �t 7 � .����C DATE TESTED ,�C,/,/� '��S PRESSURE PERCENT COZ i . INPUT CFH PERCENT 02 `2 COMPANY TESTING a STACK TEMP. �� PERCENT CO NAME OF TESTE FORM 235(REV.11/89) FOR ISTRI ION: WHITE COPY-JOB FILE YELLOW COPY-CITY SEDGWICK HEATING & AIR CONDITIONING CO. HEATING JOB NO. YG ��G 8910 WENTWORTH AVENUE SOUTH • MINNEAPOLIS, MN 55420 • (612) 881-9000 TEST RECORD ADDRESS �� ('I rc� �� O i cliu�c� 2� CITY ���'" � OCCUPANT � �� ��• F�z � OWNER � ' � , ,--: SOLD BY ���Lw cr�i Z INSTALLED BY ` � MAKE �^�cv✓�'" MODEL�3 � �p U b'3 6 ['� .� S SERIAL NO. INPUT .;6 `>, d C/ C` THERMOSTAT / - � 7� �` VENT SIZE y � VALVE �-�k{ F e �L c.. a %f TYPE OF LINER �% `�''"' � LIMIT �� Yu�•Z LINER SIZE S � LIMIT SETTING 2 �� FILTERS: SIZE Z p Y? S x �P� S NUMBER ( FAN SETTING � ' h � � WIRING ���c'a✓ :I� �-, PILOT TYPE MC� �:� : �t r <- TEST TAG V IGNITION MODEL h�-s�i� � LIGHTING INST. :✓ PILOT TIMING =� ��'t` DATE TESTED ��� I� �3` PRESSURE 3-���,u/iG PERCENT COz �� g� COMPANY TESTING �s': c� .0 t; INPUT CFH g S PERCENT OZ C� yc �- � STACK TEMP. J}�� PERCENT CO C f` NAME OF TESTER Yh i k. C�r.<nw 1�.�� FORM 235(REV.11/89) FORM DISTRIBUTION: WHITE COPV-JOB FlLE VELLOW COPV-CITY