Loading...
HomeMy WebLinkAboutseptic info . SEPTIC SYSTEM INVENTOR Y � Address: 555 Oxford Rd. PID: OS-117-23 41 0024 Building Type: residence BRs Install'd for: 5 In Musa: Yes Permit#: 5821 Date of Permit: 11/20/79 Installer: Widmer Bros. System Type: standard trench Experimental: no Appliances: lndry,dshw SYSTEM CONDITION Conformity: 1 Tank Condition: 8 DF condition: 11 Failure Pot: medium SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Setback to Bldg: 15 Cesspool: DRAINFIELD Length of Lines: 560 # Lines: 14 Trench Width: 3 Treatment Area: 1680 Type of Filter: rock Soil Boring: no Tile Size: 4 Under Tile: 12 Perc Rate: 56 Setback DF-Bldg: 10 DF Ht above Wt: 3 Soil Type: sandy loam, loam, clay loa Limitations: none WELL DAT�1 Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File yes Pump Type: subm. Depth: 133 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DA TE DESCRIPTION COMPLIANCE DA TE GALL ONS 11/26/79 installation 1 6/1/86 2000 8/8/84 no surfacing 1 9/1/88 2400 2/13/87 no surfacing 1 8/1/91 2000 6/17/88 no surfacing 1 5/21/91 no surfacing-pump tanks 1 7/10/97 no surfaci g-pump tanks 1 11-13—vc) C.��neea-p� �n �;t�, -5��.�e� I i , � � � � ,� �_ : � / � ' � � ; '3 . � ,°"' i „ , . • � - � > � . , ' , . �� ., t �, � ,-, . '. :. �. :. �. . , , . ., - " �:5s C��-�o� ��( . , / � I / � � � ���'' � -- — — / / � 1�7 - - �— ;C a�`��i .� � C � � � ��r� �7� ����� � �, �o a��� -� �".�r� ��� ��b o��- ��-a�� �o _ � � - �'`� ��o ��1� �� , �D�1a _ ��� �� 6 � o� o :, o �' CITY of ORONO ����m� � +� ��� � ,�`� �. r�,� �,. ��;���;:� �!4 Municipal Offices ��'���� � .� ���r��,�� .� Street Address: Mailing Address: `�CEgH04' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: �� � � � Address: 555 Oxford Rd. Permit #'s: 5821 Dates: 11/20/79 Contractors: Widaier Bros. (This is [�]� an existing system [ J new construction) . 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 ComDliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 pjon-Com�liant S}�,gtem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [� has or [ ] has aot been ideatified at this time. If the saturated soil level has not beea identified, this clasaification is subject to revisioa.) TANK CONDITION (S-9) : 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. � System is discharging to the surface. Tanks must be pumped out within 48 hours. Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the laet septic tank Maintenance Pumpout the tanka [ ] were or [�] were not confirmed to be watertight by the liceased pumping contractor. If the tanks were �ot confirmed to be watertight, thia classificatioa ia subject to revision.) NI�ITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreatecl effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and ondi ion. 40� .) : medi„� COMMENTS• T!(�-� Date of Inspection Sep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicat�elephOn��(��l�i'3-�57hg ���J3-1151�) current conditions. On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � � Crystai Bay, MN 55323 473-7357 OWNER ��er N�� ADDRESS l lX�� -+ PERMIT NO.'S. � DATES -;��� CONTRACTORS City Ordinance No,210 requires that each on-site sewage treatment system in Orono be i�spected on a regular basis.The on3ite sewage treatment system at the above address has bee�inspected and appears to fall into the category checked below. (This is �an existing system ❑ new construction) j� � Meets or exceeds current City atandards in all respects relating tO design,construction,and location.Appears to be operating Ja' properly- � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future probtems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replecement is necessary,soil teating will usually be required,a�d a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicatea: O Inapection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time, give eccurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. aholuld be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicatea: should be pumped out as soon aa poasible. '�Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surfece discharge. ❑ Orainfield is saturated and visibly discharging untreated �''�Inspection risen miasing—tanks could not be inspected, effluent to the surfsce. This condition may require replace- ect�on n rs 14 d�a_o�oei m m e tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If 'thin imr�ediately.Repairs must be completed within 90 days. s ree years,they should be pumped out now, ❑ Drainfield extent and condition unk�own, SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failur¢ Site Capabilities for ❑ Slope (depends on soil types,water Futur Expansion O Soil table,and system conditio�) '�Adequate ❑ High water taWe C] Low ❑ Fair ❑ Lot size �l Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High I ❑ Inadequate O Drainage ❑System is causing visible surf disc ge. COMMENTS: � Ye � -��" � r n � r,� c.�,.,- ��=�1"9� vs. Date of Inspection Se ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to fjunction properly,but is merely an opinion of the adequacy of the system under current conditions based on the available informatio�. I This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner