HomeMy WebLinkAboutseptic info SEPTIC SYSTEM INVENTOR Y j� f �. Address: 425 Oxford Rd. PID: OS-117-23 41 0023 Building Type residence #BRs/GPD 4 Systems/unit 1/1 Permit#: 814 Date of Permit: 5/16/88 Installer: Westonka Plbg. >:� System Type: standazd trench Appliances: lndry � -� SYSTEM CONDITION ;� Conformity: 1 Tank Condition: 6 DF condition: 11 Failure Pot: low � SEPTIC TANKS Material: precast conrrete Capacity: 1000, 1000 Setback to Bldg: 15 13 DRAINFIELD Length of Lines 255 # Lines: 4 Trench Width: 3 � Treatment Area: 765 Type of Filter: rock � Tile Size: 4 Under Tile 6 Perc Rate: 11.1 Setback DF-Bldg: 20 DF Ht above Wt: 3 Soil Type: loam, sandy loam Limitations: none WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File y � � , Pump Type: subm. Depth: 107 Diameter: 4 Method: drilled INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 6/1/88 installation 1 5/21/91 no surfacing-pump tanks 1 7/10/97 no surfacing-pump tanks 1 _ � , ��:,�, �, ,; , { � ; .. , ���/� ���rc ����- �J � i � � , , .:� . � . r : . , � ; . , ; . ,.._ _ , . ,: � � � : , � , , f. , ; � � � . , . , - , , , . � . f,� .. . , �t . . . _ _ a� . . . . � , . . : _ . � �a-5� �-�v r� 1�. , ---- ------ ----------- - --- - ------- r--- - - - - " - 3 r�a I� •o�(r'JJ " 3 .����Y ,� cy 3�+6 l� � � � �A2� ,� �` ` � `T ,N l�'� «`� d�iT ZZ` Zt� � / B 1 i �^� 2`�� 2Z` / o�tT 30'�' Z`1'Co � � �� � `Iz� 3�� Z so ' y�/ �S ' 3 s� ' si'(o H �y'� S� ' N � wEL�- � O� O .� O �� �-� CITY of ORONO � � � '���"��� ;� �► � :ry'���; �l�r Municipal Offices �� �' '��V�-��� G SVeet Add�ess: Mailin Address: � l�ry�� S `�CEggOg'� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 Owner: � Address: 425 Oxford Rd. Permit #'s: 814 Dates: 5/16/88 Contractors: Westonka Plbg. (This is � an existing system [ l new construction) . �ST�M C�MPLIANCE (1-3) : 1 �ode System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 �omDliant system: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. ' 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The aaturated soil leval [� has or [ ) has not been identified at thia time. If the satursted aoil level has not een identified, this clasaification is aubject to reviaion.) TANK CONDITION (5-91 ; 6 � Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. e Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During tha last septic tank Maiatenance Pumpout the taaks [ ] ware or [� ] were aot confirmed to be watertight by the licensed pumping coatractor. If the tanka we{e�ot coafirmed to be watertight, thia classificatioa is subject to revialoA.) 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. � 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition. soils. etc.) : low COMMENTS- � i� t! Date of Inspection S ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicate,�, �h� o�e�a��c,��h� s�sLe��und�� current conditions. e ep on AA 3-I151 On the North Sbore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER �� / ADDRESS JdJ ��/��- PERMIT NO.'S. / DATES ������ CONTRACTORS . City Ordinanoe No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular bssis.The onsite sewage treatment system at Me above address hes been inspected and appears to fall into the category checked below. (This is �an existing systert► ❑ new construction) � � Meets or exceeds current City atandards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high pote�tial for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City I�spector to discuss system repair/ replacement procedures. If drainfield replecement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time, give acc�rate m�surement of solids accumulation.) If tanks �.Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicatet: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminste surface discharge. ❑ Dreinfield is saturated and visibly discharging untreated O Inspection risers missing—tanks could not be inapected, effluent to the surface, This condition may require replace- Inspection risera (4"dia. pipe)must be instslled in each tenk ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed withi�90 days. the last three years,they should be pumped out now, ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depe�ds on soil types,water Future Expansion ❑ Soil table,and system condition) �Adequate ❑ High water table ow ❑ Fair ❑ Lot size Medium ❑Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: ��/9/ Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner