Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2004-P07240 - mechanical
PERMIT a CITY OF ORONO Permit Number: 2750 Kelley Parkway - PO Box 66 P07240 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 2/18/2004 SITE ADDRESS: 540 Orono Orchard Rd S Wayzata,MN 55391 PID: 02-117-23-31-0005 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 143.13 Valuation: $ 11,450.00 State Surcharge Fee: $ 5.73 TOTAL FEE: $ 148.86 APPLICANT: Watertown Sheet Metal OWNER: Sandra Larson 14730 Hwy 7 540 Orono Orchard Rd S Mayer,MN 55360 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. / e.: LyiJ'ap(i(zt._ roz_) APPLICANT PERMITEE SIGNATURE ISSUED BY SIGNATURE Copies: 1-File(Signitures Required), 1-Applicant, 1-Monthly Reports. 1-Assessing. 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs-Complete calculations, details and specifications are required for each heating, ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one: ❑ New n Addition ❑ Repair ❑X Replace Residential ❑ Commercial JOB SITE:5 O O R or^o ORc_AAirat Cc? zip: .5 9/ Owner's Name:/rFi i- 5/47/14 46Vase ,n/ Phone Number: 4/2—'3O - 27� �-- Mailing Address: S/o 0/gavot Oc.:/mid lot City: Lt.)/47 2./Q/.14 Zip: ,S5 1 / Contractor's Name: e/c.);'jJ .6'/KC/ Phone Number: 93-;.2 57-.%•2---.) 7 Mailing Address: /5(73 C# ,1/47 7 City: 07,oycr Zip: 553/a D 1 ' t SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: / Make: 4,604Ox Model: 9b 1/1-2 /R- 0 70 Fuel: /✓RT ,4 :i Flue Size: �` Input BTUs: ® 000 Output BTUs: 5' 0 0 6 CFM: %g'�/o7S COOLING SYSTEMS Quantity: / 1' Make: L 07/2 DSe Model: /3i e O21 Tons: H.Power FIREPLACES GAS LINE ONLY ❑ Gas factory fireplace ❑ Installing a Gas Line Only fVQ ❑ Wood burning factory fireplace with flue 41- D Wood Stove ❑ Wood stove with flue I)1'1, Brand Name Model No. VENTILATION No. i Kitchen Exhaust / duct recalculating /5-O cfm No. / Bath Exhaust(must have duct outside) c 0 cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) ❑ Installation or ❑ Removal ❑ Fuel oil: gallons ❑ underground ❑ inside ['outside !" ❑ LP Gas: gallons ❑ Other Gas opening 2 PERMIT FEE CALCULATION(S) 2002 State Statute ❑ Yes This Section Applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$500.00 or less; excluding the cost of the fixture or appliance: and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ 15.00 State Surcharge $ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: 1. Contract Price* is .0125%of job with a Minimum Fee of($35.00) YSe, x .0125 $ / /3, (c6ntract price) (minimum$35.00) 2. State Surcharge. ** Add the State Building Code Division a Minimum Fee of($ .50) ///iS G x .0005 $ i 73 (contract price) (minimum$.50) 3. Postage and Handling(Only mail-in applications) 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ /7'$•t�4 *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,and other fixed costs.It is the amount to be charged to the customer for the work done.If any material, equipment,labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. **The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or$.50-whichever is greater.For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code,and certifies that all statements made on this application are complete,true and correct. • Applicant's Signature: Date: .1/7:,/ Approved By: Date: 3 NW _ _ LENNOX RESIDENTIAL COOLING DATA SHEET JOB NAME: L44pSoAl DATE 0Z-/7-OV ADDRESS: ,55/0 DRONO OAcilowei ed I OUTDOOR TEMP: /5- INDOOR TEMP: 70 TEMP DIFFERENCE: g 5. I SENSIBLE LOAD CALCULATIONS GLASS SINGLE DOUBLE TRIPLE NO SHADE COMPASS GLASS AREA DESIGN TEMPERAT}J'RjE DIFFERENCE BTUH POINT SQ. FEET 10 15 20 25 30 35 10 15 20 (�! 30 35 10 15 20 25 30 35 HEAT GAIN HEAT TRANSFE MULTIPLIER N TX25 29 33 37 41 45 20 22 24 26 28 30 15 16 18 19 20 21 ,e�� NE& NW 55 60 65 70 '75 80 50 52 54 56 58 60 37 38 40 41 42 44 E&W 9 0 80 85 90 95 100 105 70 72 74 76 78 80 55 56 58 59 60 62 7 1 I(j SE& SW 70 74 78 82 86 90 60 62 64 66 68 70 47 49 51 52 53 54 S Z.Y 40 44 48 52 56 60 35 37 39 41 43 45 26 27 29 31 32 33 9g9 GLASS SINGLE DOUBLE TRIPLE INSIDE SHADE COMPASS GLASS AREA DESIGN TEMPERAT DIFFERENCE BTUH POINT SQ. FEET 10 15 20 25 30 35 ( 10 15 20 30 35 10 15 20 25 30 35 HEAT TRANSF R MULTIPLIER HEAT GAIN N 15 19 23 27 31 35 15 17 19 21 23 25 10 12 14 16 17 19 NE& NW 35 ,39 43 47 51 55 30 32 34 36 38 40 22 24 26 28 30 31 E&W 50 54 58 62" 66 70 45 47 49 51 53 55 35 36 38 40 42 44 SE& SW 40 44 48 52 56 60 35 37 39 41 43 45 29 30 32 34 36 38 S 3/e 25 29 33 37 41 45 20 22 24 26 28 30 16 18 20 22 24 26 ?-76 DESIGN TEMPERATUR IFFERENCE BTUH DOORS SQUAREE10 15 20 25 30 35 HEAT GAIN HEAT TRANSFER ULTIPLIER SOLID WOOD 6.3 8.6 10.9 13.2 14.4 15.5 SOLID WOOD •• 4.2 5.7 7.3 8.8 9.6 10.4 METAL URETHANE Z 2.6 3.5 4.5 5.4 5.9 6.4 1110METAL URETHANE " .7 2.2 3.0 3.8 4.6 5.0 5.4 /z /4t •• Weatherstripped or Storm j RUNNING FEET CEILING HEIGHT X i WALLS GROSS WALL - WINDOWS & DOOR AREAS - NET WALL AREA - DESIGN TEMPERATUR IFFERENCE BTUH FRAME WALL SaEETRE 10 15 20 30 35 HEAT GAIN HEAT TRANSFER MULTIPLIER NO INSULATION 3.7 5.0 6.4 7.8 8.5 9.1 R-11, 3" INSULATION 1.2 1.7 2.1 2.6 2.8 3.0 R-13, 3-1/2" INSULATION 1.1 1.5 1.9 2.3 2.5 2.7 R-13 + 1" POLYSTYRENE 0.8 1.1 1.4 1.7 1.8 2.0 R-19 + 1/2" POLYSTYRENE /y1/4, 0.7 1.0 1.3 1.6 1.7 1.8 .13/y DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE ) BTUH ABOVE GRADE FEET 10 HEAT GAIN HEAT TRANSFER MULTIPLIER NO INSULATION 3.2 5.8 8.3 10.9 12.2 13.4 R-5, 1" INSULATION 1li, 0.9 1.6 2.3 3.1 3.5 , 3.8 340 R-11, 3" INSULATION 0.5 0.9 1.3 1.6 1.8 '2.0 R-19, 6" INSULATION 0.3 0.5 0.8 1.0 1.2 1.3 I SENSIBLE HEAT GAIN SUBTOTAL /y03 .-) IMF _ . Sensible Heat Gain Subtotal from Page 1 /07301.•' DESIGN TEMPERATURR IFFERENCE UARBTUH CEILING S FEET E 10 15 20 [7 30 HEAT GAIN HEAT TRANSFER ULTIPLIER No Insulation 14.9 17.0 19.2 21.4 22.5 23.6 R-11, 3" Insulation 2.8 3.2 3.7 4.1 4.3 4.5 R-19, 6" Insulation g/40 1.8 2.1 2.3 2.6 2.8 2.9 02/.2/ R-30, 10" Insulation 1.1 1.3 1.5 1.6 1.7 1.8 R-38, 12" Insulation 0.9 1.0 1.1 1.3 1.3 1.4 DESIGN TEMPERATU IFFERENCE FLOOR OVER SQUARE BTUH UNCONDITIONED SPACE FEET 10 HEAT GAIN HEAT TRANSFE ULTIPLIER No Insulation 1.9 3.9 5.8 7.7 8.7 9.6 CARPET FLOOR-NO INSULATION 1.3 2.5 3.8 5.1 5.7 6.3 R-11, 3" INSULATION 0.4 0.8 1.3 1.7 1.9 2.1 R-19, 6" INSULATION ,700 0.3 0.5 0.8 1.1 1.2 1.3 ,2a0 R-30, 10" INSULATION '/ 0.2 0.4 0.6 0.7 0.8 0.9 /V4 FLOOR SQ FT. x V CEILING HEIGHT d/7 'CUBIC FT INFILTRATION/ Q VENTILATION 0.40 x/�Z JCUBIC FT + 60 = 7Y CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATU IFFERENCE BTUH CFM 10 15 20 30 36HEAT GAIN HEAT TRANSFER MULTIPLIER INFILTRATION 7/? 11.0 16.5 22.0 27.0 32.0 38.0 ,?/0 0 MECHANICAL VENTILATION 4200 11.0 16.5 22.0 27.0 32.0 38.0 SW 0 INTERNAL HEAT GAIN BTUH HEAT GAIN Number of People_'. x 300 (000 Kitchen Allowance 1,200 SENSIBLE HEAT GAIN SUBTOTAL If L4/7 DUCT GAIN BTUH F TAIN R-4, Flexible Blanket Insulation: ADD 15% (.15) �r1///9 R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) TOTAL SENSIBLE HEAT GAIN t LATENT LOAD CALCULATIONS • Conditions Outdoor Wet Bulb Indoor Wet Bulb Grains Wet 80 62.5 50 414051l► 75 62.5 35 •edium Dry 70 62.5 20 Dry 65 62.5 0 Based on 75°F Indoor Dry Bulb at 50% RH. LATENT LOAD-INFILTRATION QQA�C 0.68 x Grains x 7 Infiltration CFM /v LATENT LOAD-VENTILATION t 0.68 x 35 Grains x T'Ventilation CFM 7f 0 I LATENT LOAD-PEOPLE /,I Number of People_Ala_x 230 94 0 TOTAL LATENT HEAT,GAIN 7 07‘9 I TOTAL SENSIBLE AND LATENT HEAT GAIN 32 7S6 I NOTE: All Heat Transfer Multipliers from ACCA Manual"J" Sixth Edition and for a medium outdoor daily temperature range. CL-841-L7 002345 Litho U.S.A. .. . . LENNOX RESIDENTIAL HEATING DATA SHEET • JOB NAME:/rt-Art at-5phdL 1....vespA/ DATE ..2-/7-- Or ADDRESS:54/O 4l40IV J ORCingii Q A OUTDOOR TEMP: -.2 6 INDOOR TEMP: 70 TEMP. DIFFERENCE: 4M---1 --• DESIGN TEMPERATURE DIFFERENCE BTUH MOVABLE GLASS WINDOWS S�EETRE 30 1 35 140 145 150 155 160 165 170 175 180 851 J 90 951HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 39 45 52 58 65 71 78 84 90 97 103 110 116 123 SINGLE GLASS W/STORM 21 25 28 31 35 38 42 45 49 52 56 59 63 66 DOUBLE GL/,SS .22$ 28 32 37 41 46 50 55 60 64 69 73 78 .87 j w5V/ DOUBLE GLASS WiSTORM 16 19 21 24 27 29 32 35 37 40 42 45 48 50 DESIGN TEMPERATURE DIFFERENCE BTUH SLIDING GLASS DOORS SQUARE 30 135 j 40 145 150 155 160 [65 170 175 [80 1 85 1 90 195FHEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS _/ 42 48 55 62 69 76 83 90 97 104 110 117 124 131 SINGLE GLASS W/STORM /// 22 26 .29 33 37 40 44 48 51 55 59 62 66 70 DOUBLE GLASS / 29 34 39 43 48 53 58 63 67 72 77 82 87 91 WAMEMPIONINSIMMINIMINIMMINOMMIIIIMINI DESIGN TEMPERATURE DIFFERENCE BTUH DOORS SnEETRE 30 [ 35140145150155160165170 ! 75180185190195 HEAT LOSS HEAT TRANSFER MULTIPLIER SOLID WOOD 31 36 41 46 51 56 62 67 72 77 82 87 92 97 SOLID WOOD" 18 21 24 27 30 33 36 39 42 45 47 50 56 METAL URETHANE --27 23 27 30 34 38 42 45 49 53 57 60 64 72 /10 METAL URETHANE" 27 13 16 18 20 22 25 27 29 31 33 36 38 42 fel "Weatherstripped or Storm RUNNING FEET VI? CEILING HEIGHT X WALLS GROSS WALL ? WINDOWS & DOOR AREAS NET WALL AREA I /14914° t DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL SQUARE 30 135 [ 40 1 45 150 155 160 165 170 J 75 180 185 190 195 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 8 10 11 12 14 15 17 18 19 21 22 23 25 26 P-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 8.1 8.5 R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 6.3 6.6 I R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5 5.7 i R-19 - 1/2" POLYSTYRENE /1/4/47 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4. 5.2 .7;,,8•5' DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH ABOVE GRADE FEET 30 135 140 145 150 155 160 165 170 175 180 1 85 ( 90 195 HEAT LOSE HEAT TRANSFER MULTIPLIER NO INSULATION 16 18 21 23 26 28 31 33 36 38 41 44 46 49 _ R-5, 1" INSULATION / 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12 3 713.7 /5'44 R-11, 3" INSULATION ``++'' 2.3 2.7 3.1 3.5 3.8 4.2 4.6 5.0 5.4 5.8 6.2 6. .9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 13.4 3.6 3.8 4.1 4.3 4.6 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL 15015516016517017518085190 1 4590 195 BTU H BELOW GRADE FEET HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 2s,.7._ 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.6 10.3 11.0 11.8 12. 13. 4.0 /0 7/k R-5, 1" INSULATION 12.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7. 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL yp 1� 1 Heat Loss Subtotal from Page 1 yV v213 I DESIGN TEMPERATURE DIFFERENCE i BTUH CEILING SQUARE 30 1 35 140 45 150 155 160 1 65 70 1 75 180 185 190 1 95• HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 18 21 24 27 30 33 36 39 42 45 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.6 7.0 7.5 7.9 8.4 3-19, 6" INSULATION VIP HEAT X1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5(17 5.0 3G)/7 8-30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.8 3.0 3.1 9-38, 12'" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2.2 2.3 2.51 FLOOR OVER AN SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET 30135 140 145 150 1 `55 160 1 65 1 70 175 180 185 1 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 10 11 13 14 16 17 19 21 22 24 25 27 28 30 9-11, 3" INSULATION 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 9-19, 6"INSULATION 0 O 1.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4. 07/4.9 9$(p - 9-.30, 9-.30, 10"INSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.1 3.3 3.5 DESIGN TEMPERATURE DIFFERENCE BTUH BASEMENT FLOOR SQUARE 30 1 35 140 145 150 155 160 1 65 1 70 1 75 180 185 1 90 1 95FHEAT LOSS HEAT TRANSFER MULTIPLIER .3l•SEMENT�LOOP 4iCn 0.8 I 1.0 I 1.1 11.3 11.4 11.5 I 1.7 11.8 I 2.0 12.1 I 2.2 12.i9 2.7 (4)265.""'� DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB WITHOUT LINEARBTUH PERIMETER SYSTEM FOOT 30 135 140 145 150 155 160 1 65 1 70 175 180 185 1 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER VO EDGE INSULATION 25 29 33 37 41 45 49 53 57 61 65 69 73 77 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 31 33 35 37 39 ?" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8 17.8 18.9 20.0 DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB LINEAR 30 135 140 145 150 1 ``5 1 60 1 65 1 70 175 180 1 85 190 1 95 BTUH WITH PERIMETER SYSTEM FOOT HEAT TRANSFER MULTIPLIER HEAT LOSS NO EDGE INSULATION 57 67 76 86 95 105 114 124 133 143 152 162 171 181 1" EDGE INSULATION 34 40 46 52 57 63 69 74 80 86 91 97 103 109 2" EDGE INSULATION 28 33 37 42 47 51 56 61 65 70 75 79 84 89 f An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per linear foot of crack. / FLOOR SQ FT. x / _ CEILING HEIGHT =/f7Jh.UBIC FT INFILTRATION/ VENTILATION 0.40 x/�ZIUBIC FT _ 60 = 7/ CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 1 45 50 155 160 1 65 1 70 175 1 80 185 190 95 • �/ HEAT TRANSFER MULTIPLIER HEAT LOSS INFILTRATION 7 E 33 39 4450 55 61 66 72 77 83 88 94 105 7 742 42-. MECHANICAL VENTILATIONA' O 0 33 39 44 150 1 ,�55 61 66 72 77 83 88 94 105 HEAT LOSS SUBTOTAL 3giLe DUCT LOSS ' ' BTUH HES LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% 1.15) . _r_ R-7, 2" Flexible Blanket Insulation: ADD 10% 1.10) `I al TOTAL HEAT LOSS NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. HL-841-L7 002344 Litho U.S.A. 3 / DATE TIME CITY OF ORONO CALLED IN 5742 `al INSPECTION NOTJ 7 Z SCHEDULED S-/3 1=uo/'c4 PERMIT NO. ((' . COMPLETED /� ADDRESS 540 claw() Q1 K(�( OWNER CONTR. TELEPHONE NO. DESCRIPTION W 01 FOOTING 11 MECHANICA RI 18 EXCAV/GRADING/FILLING H02 FRAMING 1 EC3 CI ANICA1,GINA 19 LAKESHORE/WETLANDS Q 03 INSULATION 24/2 RNER/FIREPLACE 34 TREE REMOVAL 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP IQ 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO c0.) COMMENTS: cc W C CC 0 CC 0 U- W ft Q W Z W CC 2 ❑'WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE W 0 CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY 0 0 CORRECT WORK,CALL FOR REINSPECTION TEMPORARY 0 BEFORE COVERING PERMANENT O CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next'nspection 24 hours in advance. (952) 249-4600 OwnerIContract 't : Inspector. White Copy/Inspector's File Canary Copy/Site Notice