HomeMy WebLinkAbout1998-010609 - mechanical PERMIT QITYOF ORONO PERMIT TYPE: 2750 Kelley Parkway- P.O. Box 66 MECHANICAL Crystal Bay, Minnesota 55323 Permit Number: 010609 (612)473-7357 Date Issued: 08/17/98' SITE ADDRESS: . 120 ORONO ORCHARD RD JG P 1' N. 0y-117-2_-21-0 DESCRIPTION: FLt 1E SIZE 6„ FUEL NATURAL GAS MAKE 1 HEATING SYSTEMS BRYANBRYANT MODEL30AAVi048100 INPUT 100, 000 1 AIR CONDITIONING r1AF��:E AMER STANDARD MODEL 7AL0s E A 100A TONS 3 REMARKS: FEE SUMMARY: VAL DAT ION $8,550 Base Fee $106 . 88 MAIL IN S j,,yt.a: Surcharge 14.2: Total Fee $112.64 Subtotal $111 . 16 CONTRACTOR: — App=licant. — OWNER: SEDGWICK HTG 2 AC C :' F=81°9c_; (a MERCHANT LOUIS 8910 WENTWORTH AVE '_ •: 120 ORONO ORCHARD RD MINNEAPOLIS MN 55420-2:=14 ORO NOMN 553 91 (612) 881-9000 475-2647 THE N ERS GED HEREBY RE k E�T 1 PER) ISS 1 ON TOMAKE, THE REAL IMP E E "S SPECIFIED' AND AGREES TO DO ALL. :WORK IN STRICT �MPLIAN E WITS ALL CHIT' oRoN'7 ORDINANCES AND STATE, OF MINNESOTA NNESOTA' SU I LD 11G CODE REQU T : NTS - ...J APPLICANT/PERMITEE SIGNATURE ISSUED BY:SIGNAT R� a, caro fiECEIVED 7,v R1!2 if A 1998 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357. Please check one: New Addition Repair Replace Residential Commercial JOB SITE: (,2b 0Elind ore- ,,p__ 4"d_ ,,le) Zip: ( 1' i Owner's Name: ��,v-ss /111,44c%t Telephone Number: 4/7s_de„ 4/7 Mailing Address: be/ z — City: Ahs Zip: ..c.57.34 Contractor's Name: [1MU .. . : ,; Telephone Number: CO. Mailing Address: 8910 We „•,,,. _ Zi p: • •. ,MV 5542C 'n SYSTEM DESCRIPTION 881-9000 M HEATING SYSTEMS Quantity: Make: Model: I' ' ilgr e) r\ Fuel: Flue Size: i96/, Input BTUs: /AP LpD Output BTUs: CFM: COOLING SYSTEMS Quantity: I Make: avn/J7_ Model: 701dD.3LA /UOfi Tons: ,3 H. Power WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add-on Factory fireplace with flue Factory Fireplace (s) Freestanding Masonry Wood Stove (s) Franklin, other Brand Name Model No. Mfgr's Min., Clearances, side , rear , min. flue dia. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) g.„C0" x .0125 $ /06-k7 (contract price) 2. State Surcharge. ** Add the State Building Code Division Surcharge to each permit. x .0005 $ 4. 1 7 or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ I 1 i2. 1,4 * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: IJA1 , L i,; . _ Date: ?/,4f/y/ f 'Zr Approved By: R Date: • Heat Loss Subtotal from Page 1 DESIGN TEMPERATURE DIFFERENCE UABTUH CEILING SaEETRE 30 135 140 145 1 50 155 1 60 165 1 70 1 75 180 1 85 190 195 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 18 21 24 27 1 30 33 36 139 42 45 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3I+f 5.7 6.2 6.6 7.0 7.5 8.4 R-19, 6" INSULATION 1 j(O (� 1.6 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 4.8 .0 C� R-30, 10" INSULATION 1.0 1.2 1.3 1.5 t1"1.6 1.8 2.0 2.1 2.3 2.5 2.6 1 2.8 3.1 R-38, 12" INSULATION 0.8 0.9 1 1.0 1.2 1 1.3 1.4 1.6 1.7 11.8 2.0 2.1 12.2 12.3 2.5 FLOOR OVER AN SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET 30 1 35 ( ao I I 1 1 1 170 1 I I I I s5 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 10 111 13 14 16 1 17 19 21 22 24 25 27 28 30 R-11, 3" INSULATION 2.4112.8 3.2 3.6_4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 R-19, 6"INSULATION 1.6 1 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.613.9 1 4.2 4.4 1 4.7 4.9 R-30, 10"INSULATION 1.1 1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 12.8 1 3.0 3.1 !3.3 3.5 DESIGN TEMPERATURE DIFFERENCE BASEMENT FLOOR SQUARE 30 135 140 145 150 155 160 165 1 70 175 180 185 ; 90 196 BTUH FEET HEAT LOSS HEAT TRANSFER MULTIPLIER BASEMENT FLOOR l '7 O 0.8 1 1.0 11.1 1 1.3 11.4 11.5 1 1.7 1 1.8 12.0 12.1 12.2 12. I2.5 2 � 7 I CONCRETE SLAB WITHOUT LINEAR` DESIGN TEMPERATURE DIFFERENCE BTUH PERIMETER SYSTEM FOOT 30 1 35 I � i � I � I I � I � 17o I I � I � 1 � 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 37 1 41 45 49 5357 61 65 69 1 73 77 1" EDGE 13 15 17 19 1,21 25 27 29 31 33 35 I 37 39 2" INSULATION INSULATION 6.3 1 7.4 8.4 9.4 110.511235112.6113? 614.7 15.8 16.81-17.8118.9 20.0 CONCRETE SLAB LINEAR DESIGN TEMPERATURE DIFFERENCE1 BTUH WITH PERIMETER SYSTEM FOOT 30 135 140 145 150 155 160 165 1 70 1 75 180 1 85 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 57 67' 76 J 86 95 105 114 124 133 143 152 162 1 171 1181 1" EDGE INSULATION 34 40 46 52 57 63 69 74 80 86 91 97 1103 109 2" EDGE INSULATION 28 1 33 37 42 47 1 51 56 61 65 70 75 79 1 84 89 An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per linear foot of crack. n FLOOR SQ FT. x CEILING HEIGHT = l��°COBQFT INFILTRATION/ VENTILATION 0.40 x CUBIC FT - 60 = CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 145 150 155 60 165 1 70 75 180 185 1 90 195 HEAT TRANSFER MULTIPLIER HEAT LOSS ) r INFILTRATION /01--0 33 '39 44 150-1 55 61 66 72 77 83 88 94 99 05 i l OXO' MECHANICAL VENTILATION 33 39 44 1 50 1 55 61 66 72 77 83 , 88 194 105 HEAT LOSS SUBTOTAL DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% 1.151 R-7, 2" Flexible Blanket Insulation: ADD 10% 1.101 TOTAL HEAT LOSS 75-7?-7j NOTE: 7 ` - NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. HL-841-L7 002344 Litho U.S.A. sedgwiclk HEATING&AIR CONDITIONING CO. RESIDENTIAL HEATING DATA SHEET Comfort von can count on JOB NAME: 0 I S G�/c���.-t (DATE ADDRESS: / C7rovt f9 (7rcJ-► ot_.-rJ I OUTDOOR TEMP: -,t U INDOOR TEMP:+ 7 0 TEMP. DIFFERENCE: '7(7 DESIGN TEMPERATURE DIFFERENCE UARBTUH MOVABLE GLASS WINDOWS SQ E 30 135 140 145 150 155 160 1 65 1 70 175 180 185 190 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 39 45 52 58 65 71 78 84 90 97 103 110 116 123 SINGLE GLASS W/STORM 21 25 28 31 35 38 42 45 49 52 56 59 § DOUBLE GLASS 28 32 37 41 46 50 55 60 64 69 73 78 82 ./87 / S UC6 DOUBLE GLASS W/STORM 16 19 21 24 27 29 32 35 37 40 42 45 N 50 DESIGN TEMPERATURE DIFFERENCE BTUH SLIDING GLASS DOORS SaEETRE 30 135 140 145 150 155 160 165 1 70 175 180 185 1 90 ( 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 42 48 55 62 69 76 83 90 97 104 110 117 124 131 SINGLE GLASS W/STORMl 22 26 29 33 37 40 44 48 51 55 59 62 0 DOUBLE GLASS L a- 29 34 39 43 48 53 58 63 67 72 77 82 87 91 `5 7,57 DESIGN TEMPERATURE DIFFERENCE BTUH DOORS SQUARE 30 1 35 140 145 150 155 160 165 1 70 1 75 180 185 190 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SOLID WOOD 31 36 41 46 51 56 62 67 72 77 82 87 SOLID WOOD** of 5 18 21 24 27 30 33 36 39 42 45 47 50( 53 6 5 3 METAL URETHANE / 23 27 30 34 38 42 45 49 53 57 60 64 -� 72 METAL URETHANE** 13 16 18 20 22 25 27 29 31 33 36 38 40 42 **Weatherstripped or Storm RUNNING FEET CEILING HEIGHT X WALLS GROSS WALL WINDOWS & DOOR AREAS - �I NET WALL AREA ( ak070 _ DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL SaEETRE 3o 135 1 40 145 1 50 155 1 60 1651 70 175 1 80 1 85 190 195 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 8 10 11 12 14 15 17 18 19 21 22 236(25;)26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7. 8. 8.5 �t5� R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 b. 6.6 R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1/2" POLYSTYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4.7 4.9 5.2 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH ABOVE GRADE FEET 30 135 140 145 150 155 160 165 1 70 175 180 185 190 195 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 16 18 21 23 26 28 31 33 36 38 41 44 46 49 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.5 _3.8 4.2 4.6 5.0_ 5.4 5.8 6.2 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.6 3.8 4.1 4.3 4.6 MASONRY WALL SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH 30 135 1 ao 1 45 150 155 1 so 1 65 1 70 175 1 ao I 85 190 195 BELOW GRADE FEET HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION /(10 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.6 10.3 11.0 11.8 12.g 13.21 .0 G R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4x. 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL