HomeMy WebLinkAbout1993-005517 - furnace PERMIT
TCITY OF ORONO PERMIT TYPE:
t► 2750 Kelley Parkway • P.O. Box 815Permit Number: MEC:HAN I CAL
Orono, Minnesota 55356-0815 Date Issued: t y[y5S 17
(612) 473-7357 0q/21/q:::
SITE ADDRESS:
1290 ORONO OAKS DR
CH
P. I .N. : 35-11 t - _:4.-000_:
DESCRIPTION:
FURNACE
1 HEATING SYSTEMS CFM 1 , 500 FLUE SIZE :::"
FUEL NATURAL GAS MAKE CARRIER
MODEL 1 t x a 1 LG OUTPUT 102,000
INPUT 110,000
1 AIR CONDITIONING MAKE CARRIER MODEL :3SCKOGO
TONS S
-_-r_
REMARKS: - 7, -,:".7'0
FEE SUMMARY: _
VALUATION $7,:=:00
Base Fee $91 ...5 MAIL IN
Surcharge $;__s Total Fee .$'? '. 40 . _.
Subtotal $94.90
CONTRACTOR: - Applicant - OWNER:
FLARE HTG Si AC: 3542116F, MARK PETTY CONSTRUCTION
5E.4 MEDELS:;OHN AVE N 4669 109 AVE
GOLDEN VALLEY MN 55427 CLEAR LAKE MN 55319
(612) 54.E-11166 74_,-_3718
-t
THEF' ss, lakey HEREBY;' . S19 PE $01004 T ,MAKE E 2tkEAL. .,IMPI EMNTS
SPECIFIED OR. 4i'l' LL WO fly, 'CT ' MPL'I WE: WITH PLC CITY OF
' OROS: '4.INANCE '`i _, S . w- OF,; j ` T BUILDING C*' xREQUIREMENTS .
APPLICANT/PERMITEE SIGNATURE ISSUED BY SIGNATURE L.
k `
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
GENERAL INFORMATION SEP 1 5 1993
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID
UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS
POSTED ON THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type,manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code
requirements.
6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required.
7. House Heating Test Record must be submitted before fmal.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS� WILL NOT BE PROCESSED. If you have questions, call 473-7357.
/
Please check one: _ New Addition Repair Replace
X Residential Commercial
JOB SITE:\2 C\0
Owner's Name: g� tv <A-` Telephone Number: \
Mailing Address
Contractor's Name �c,s _' ,.\ TelephoneNumber: �_\\l.QL
Mailing Address
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make:
Model: 1S`E.( U5
Fuel:
Flue Size:
Input BTUs: \\o 1oyJ
Output BTUs: ` ",1�0��
CFM: \ z
COOLING SYSTEMS
Quantity:
Make: \--L.QS
Model: c0
Tons:
H. Power
. `
WOOD BURNING EQUIPMENT
Wood stove with flue
Wood combination or add-on
Factory fireplace with flue Masonry Fireplace (s) Freestanding
Wood Stove (s) Franklin, other
Brand Name Model No.
Mfgr's Min., Clearances, sidg , rear , min. flue dia.
Total
VENTILATION
No. Kitchen Exhaust ducted recirculatingcfm
c
No. Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations
Total
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)x 1.25 $ CI\�,�5
(contract price)
2. State Surcharge. ** Add the State Building Code Division
Surcharge to each permit. Y'j�,U� x .0005 $
(contract price) $ 0
3. Postage and Handling (Only mail-in applications)
4. TOTAL PERMIT FEE (Add lines 1-3 above)
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the
customer for the work done. If any material, equipment, labor,or installation are furnished by the owner,
tenant or any other party the reasonable market value of such items must be added to the estimated cost
or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,
the City may request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is
greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do
all work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements made on this application are complete, true
and correct.
Applicant's Signatur �1 .� ► Date: -.
Approved By:
� OW Date: ( q3
,
` 1
°
- ` ^ %., I
� ^
�. �
DETAILED REPORT FOR ENTIRE HOU',.-3=
�rcpared For: Prepared By:
MARK PETTY CONST TIM LAUDNER
FLARE HEATING
Job Name: BORDSON RESIDENCE
***************************************************************************
EXPOSURE
GLASS NORTH SOUTH EAST WEST NE/NW SE/SW HORZ . TOTAL
AREA � 1111 221 183 : 2811 221 22 | O : 641 |
COOLING | 1 ,674 ! 5081 8,250 | 12,667 | 662 | 838 | 0 ! 24,598 |
HEATING | 4,5551 9031 7,5101 11 ,532 ! 903 | 9031 0 | 26,3071
BELOW
WALLS NORTH CUTH EAST WEST NE/NW SE/SW GRADE TOTAL
AREA 1 1 , 1051 1 ,0961 1 ,0611 9431 381 381 01 4,2811
COOLING | 1 ,0031 9951 9631 8561 34| 341 0| 3,885:
HEATING : 4,381 : 4,3451 4,2071 3,7391 1511 1511 5,6861 226591
DOORS NORTH OUTH EAST WEST NE/NW SE/SW TOTAL
AREA | • 01 98 | 201 401 0: 01 : 158 |
COOLING 1 01 1 , 1911 243 } 486 | 01 0| 1 1 ,920 |
HEATING 1 0L 5,2041 1 ,062 : 2, 124 : 0 | 01 1 8,390 |
FLOOR AREA COOLING HEATING
01
2 | 16 | 4,640
CEILING REA COOLING HEATING
471 | 1 ,650 | 3,622
_
MISCELLANEOUS COOLING LOADS
People Sensible Loam 1 ,350 Latent Load 10,545
Lights & Appl . Load 1 , 195 Latent Safety Btuh 527
Ventilation Load 935
Duct Heat Gain 0
Infiltration Load 815
Sensible Safety Btut- 1 ,818
TOTAL SENSIBLE LOAD 38, 182 TOTAL LATENT LOAD 11 ,073
Summer ACH 0.06 Temp. Swing Mult. 1 .00
*** Total Cooling Load 49,255 BTUH Or 4. 10 Tons ***
MISCELLANEOUS HEATING LOADS
Infiltration Load | 8,624 Ventilation Load 4,950
Duct Heat Loss 0 Safety Btuh 3,960
Winter ACH 0. 12
*** Total Heating Load 83, 151 BTUH ***
^ � ~r
° ' " 04-28-93
3. 1
SUMMARY REPORT
Prepared For: Prepared By:
MARK PETTY CONST TIM LAUDNER
FLARE HEATING
Job Name: BORDSON RESIDENCE
******************%********************************************************
DESIGN CONDITIONS for
OUTDOOR INDOOR
SUMrER WINTER SUMMER WINTER
Dry Bulb 92 -20 75 70
Wet Bulb 75 67
Daily Range 22 Daily Swing 3.0
Latitude 44 Elevation 822
Safety Factor (%) 5
Latent Factor (%) 29
***************************************************************************
Sensible
Room Heating Heating Cooling Cooling
Name BTUH CFM BTUH CFM
Basement 28,343 396 6,518 329
Main Level ' 36,302 508 21 ,011 1 ,061
Upper Level 18,505 259 10,653 538
83, 151 1 , 163 38, 182 1 ,928
HEATING DELTA T 65.0 COOLING DELTA T 18'0
NOTE: *** Calculated Airflow is based upon load requirements.
Verify that airflow calculated is compatible with
selected equipment requirements. ***
DATE TIME
CITY OF ORONO CALLED IN ,he/s3
INSPECTION NOTICE 5 J-5(�J SCHEDULED 9//7/3
PERMIT NO. / COMPLETED &l ►& •
ADDRESS
OWN ER C� . CONTR. - .�
.G�t�
TELEPHONE NO. -331,2 —it 46.
DESCRIPTION d
LU 01 FOOTING 'ECHANICAL RI 16 WELL TEST PUMP
Q 02 FRAMING • -• • •L FINAL 18 EXCAV/GRADING/FILLING
03 INSULATION 24/25 WOOD BURNER/FIREPLACE 19 LAKESHORENVETLANDS
• 04 WALL BD. 12 WATER HOOK-UP 34 TREE REMOVAL
Q 05 FINAL 13 METER SET/TURN ON 17 SITE INSPECTION
07 DEMO—SITE 14 SEWER HOOK-UP 06 PROGRESS
07 DEMO—FINAL 27 SEPTIC MAINT. 21 COMPLAINT
i 09 PLUMBING RI 15 SEPTIC INSTALL. 22 FOLLOW-UP
10 PLUMBING FINAL 23 SEPTIC FINAL
Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO
o COMMENTS:
cc
W
a
cc
0
>.
cc
0
LL
W
cc
W
W
cc
d
WCC WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE
W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
(21 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
✓ BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. L. PHOTO TAKEN
INSPECTOR WILL RETURN
❑STOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the nex inspection 24 hours in advance.473-7357
OwnerlContr�n i
r.
Inspecto
White Copy/Inspector's File Canary Copy/Site Notice
ic
CITY OF ORONO CALLED IN sof/ 93 TIME
INSPECTION NOTICE SCHEDULED /0A-M_.? 51!.3.9
PERMIT NO. —7_S/'7 COMPLETED
ADDRESS c 96 O� •
OWNER CONTR. ..
TELEPHONE NO. -//66
E DESCRIPTION
09) 4fccLL
Lu 01 FOOTING 11 MECHANICAL RI 16 WELL TEST PUMP 74–'204-
Q 02 FRAMING 11 MFINAL 18 EXCAVIGRADINGIFILLING
ti 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 19 LAKESHORE/WETLANDS
• 04 WALL BD. 12 WATER HOOK-UP 34 TREE REMOVAL
Q 05 FINAL 13 METER SET/TURN ON 17 SITE INSPECTION
07 DEMO—SITE 14 SEWER HOOK-UP 06 PROGRESS
v 07 DEMO—FINAL 27 SEPTIC MAINT. 21 COMPLAINT
= 09 PLUMBING RI 15 SEPTIC INSTALL. 22 FOLLOW-UP
10 PLUMBING FINAL 23 SEPTIC FINAL
Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO
COMMENTS:cc
Lu IM u
cc
O
cc
O
LL.W
cc
(,)W
z
W
cc
WCC ` ORK SATISFACTORY:PROCEED ElPROJECT COMPLETE
CORRECT WORK&PROCEED El ISSUE CERTIFICATE OF OCCUPANCY
❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
U BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. E PHOTO TAKEN
INSPECTOR WILL RETURN CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next in tion 24 hours in advance.473-7357
Owner!Contracto . e:
Inspector.
White Copylinspector's File Canary Copy/Site Notice
DATE TIME
CITY OF ORONO CALLED IN // —/7—fc3
INSPECTION NOTICE_ SCHEDULED //— / I //:3 0
PERMIT NO. j .S l7 COMPLETED IA vi
ADDRESS 1,;191 (./ `u , a-/e-- itrA
OWNER /..e. CONTR. _93,--0-e-L, 1441
TELEPHONE NO.00 5-L-/)- //
DESCRIPTION
Uj 01 FOOTING 11 M ._. e RI 16 WELL TEST PUMP
Q 02 FRAMING 11 MECHANICAL FINA 18 EXCAVIGRADINGIFILLING
ti 03 INSULATION 24/25 "••• ;.- • - REPLACE 19 LAKESHOREIWETLANDS
Z04 WALL BD. 12 WATER HOOK-UP 34 TREE REMOVAL
cr 05 FINAL 13 METER SET/TURN ON 17 SITE INSPECTION
1, 07 DEMO—SITE 14 SEWER HOOK-UP 06 PROGRESS
v 07 DEMO—FINAL 27 SEPTIC MAINT. 21 COMPLAINT
st
09 PLUMBING RI 15 SEPTIC INSTALL. 22 FOLLOW-UP
v 10 PLUMBING FINAL 23 SEPTIC FINAL
Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO
o COMMENTS:
cc
W
Q.
cc
O
cc
O
W
cc
Q
k.
W
Z
W
cr
2 WORK SATISFACTORY:PROCEED X PROJECT COMPLETE
W
CC ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
W
O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
Ci BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. G PHOTO TAKEN
INSPECTOR WILL RETURN
C CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance.473-7357
OwnerIContracl n site:
Inspector.
White Copyllnspector's File Canary Copy/Site Notice