Loading...
HomeMy WebLinkAboutseptic info migir 1034,, / O O CITY OF ORONO " '� Municipal Offices r] ..17"110t.' a ,Sr '$„ Ij "�Aji r Street Address Mailing Address: �� ���, G� Ike2750 Kelley Parkway P.O.Box 66 � E8H0�� Orono,MN 55356 Crystal Bay,MN 55323-0066 To: The Current Owner of Address 500 ORCHARD PARK RD City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No 4../ If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump ut Needed Yes No The city recommends the septic tank(s) and/or lift tank be serviced and Eumped out every three (3) years. City records indicate the tank(s)were last pumped out on '`'1 -o 5- . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: Insp�Ctt :�atiZ Date of Inspection: 6, 'b-7 p p Telephone (952) 249-4600 • Fax(952) 249-4616 www.ci.orono.mn.us 141Ww City of Orono Memo To: Orono residents on mound type septic systems From: Willie Gibbs, ISTS Manager Date: May 10,2006 Re; Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent(the liquid left after the "other stuff has been removed) in the summer time and allows the mound system to help breakdown nitrogen in the effluent Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential freezing problems. Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember,that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound system please feel free to call me, I can be reached at 952-249-4626. 1 7(4.7 °.4 ) CITY of ORONO \vs, , flc ,1/4 44 2-,- ,. Municipal Offices r�G Street Address: c15a.—a49—y60 0 Mailing Address: �EsKp 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: Qc) Ore h A r PACK City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any . reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 6 Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped a ( ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. • DRAINFIELD CONDITION(8-10): IT 8 Drainfleld is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfleld is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: PC, AA P IAA lel' . otulhiti, eg.72-L-14-3-4 Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. -.,i% 04i\ 0 CITY of ORONO ,,,,,./. . i v� y','. .'ik', -^ 41/ I' Municipal Offices .- 1~Y J 'ti \,t .' .)..1,1" .,.k���G Street Address: Mailing Address: `9$ p4'// 2750 KelleyParkwayP.O. Box 66 �\ESH/ —` Orono, MN 55356 a Crystal Bay, MN 55323-0066( To Current Owner: Address: 5d 0 0( r PckC k g(1 City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): t I ) "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 0 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 1) "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISIS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISIS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 6- Tk inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. INFIELD CONDITION(8-10): 8 Drainfield is dry,no surfacing evident. Some evidence of surfacing, not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: l'^60^ 1 0 o(LS a IL_ El to-r, to X Ct•-• pc)r }r,r1(c S n`o'r 'I-1) CO Z - f=X covvS o.. )racALS - PVN\ c t;Qc.:(S c.....,,io- at (}c;c.t 1-j 10.'31-03 . ck-A'S-C) C)4Nc•-* a—t-z"IA-0,-, Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us CITY OF ORONO g O Municipal Offices O O Post Office Box 66 '-= gip. Crystal Bay, MN 55323-0066 Ar ON—SITE SEWAGE TREATMENT �) INSPECTION REPORT r �teNL� .4 ,s, Address: 6 Owner: -7--A00/0“ /Tu/3 1'1 0 Ogeling.b / 191 c./Xog (ss3 Oi ?) Permit #'s: 5.733 Dates: 9-Z-1-79 Contractors: i(/V1675 City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is jX an existing system ( ] new construction) SYSTEM CONFORMITY (1-3): I 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic ( ] has or ( ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): `) Tank inspection indicates: Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pupped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pupped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 1/ Dfield inspection indicates: C11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): ij14 Tr`Ti4 w fes/ ti POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): fr 7 b/u kii COMMENTS: NO S urz:F ACIV1q a# iki ')Q/J, (Jon',bGtltt an A6O)t iru ` /,- _ (101A-Woo. 5�/Or/c .375i-ec� /War) * k2._1 r'' 5��'jcic�j la7 l2 -31--At 0c36 . Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner .0, 0:4 0 0 , „___ CITY of ORONO vi 41, rb 1$1, 'V ; ti Municipal Offices + t , :% , G X " ' O Street Address: Mailing 44 Y 750 Kelley Parkway P.O. Boxx 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: / ,',i0 b L'i--> �J/ Address:500 Orchard Park Rd. Permit #'s:5733 Dates:9/24/79 Contractors:Hayes Exc. (This is ( an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical se ion between the bottom 6f—tire-dre41 € e a sa urated- s�5t1�€ve . (The saturated soil level ,04, has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 6 Pumpout not needed at this time /6% Solids accumulation in tanks indicates they should be pumped out this year. jj System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or 00 were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 1] Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium COMMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days of failure (surface�di(scharge) , whichever comes first. / oZ `/Ca /I, ��irL i1 _y/,.-- ---' Date of Inspection Seg is Sys em Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 Iv- N. CITY OF ORONO O Municipal Offices O O Post Office Box 66 44 Crystal Bay, MN 55323-0066 '." '' P ON—SITE SEWAGE TREATMENT '''��► 4)114 INSPECTION REPORT 9kESH0�' Owner: ( as filo Address: SOO Orchard Poirk Pd. Permit #'s: 73K Dates: I—a2'/-7`? Contractors: gryP�.S 5G. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is SANan existing system I ] new construction) SYSTEM CONFORMITY (1-3): / ® "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic I ] has or DCL has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): 6 Tank inspection indicates: Pumpout not needed at this time. 40 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the Last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 11 Dr field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): ddi7XY., COMMENTS: Date of Inspection ptic ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORTOF POST OFFICE BOX 66 O R O N O 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNERrn �'T�►AJ�Y�-S ADDRESS %SODO"C-/ gS 11234- /Vs[, PERMIT NO.'S. DATES 9-024-79 CONTRACTORS tine /74/6-C. 44. City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is 9t an existing system 0 new construction) pf 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. • 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. ▪ 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. ▪ 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ,Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drain field inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) 0 Adequate ❑ High water table 0 Low 0 Fair ❑ Lot size 0 Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible surfs dis�carge. COMMENTS°��/S./4)/M #( 17,1-'el 1197.\-1 71771) ..h ��1"11/11719/ /r ;a a 47/- 4/-?/ Date of Inspection eptic SystemInspector Pe P Pe Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner