Loading...
HomeMy WebLinkAboutseptic info �.. SEPTIC SYSTEM INVENTORY Address: 1005 Old Long Lake Rd. PID: 35-118-23 42 0001 Building Type: residence BRs Install'd for: 4 In Musa: Yes Permit#: 5213 Date of Permit: 6/22/78 Installer: Jerry Johnson System Type: standard trench Experimental: no Appliances: lndry,dshw SYSTEM CONDITION Conformity: 2 Tank Condition: 9 DF condition: 11 Failure Pot: medium SEPTIC TANKS Material: concrete precast& Capacity: 1000, 500 Setback to Bldg: 25 Cesspool: unknown DRAINFIELD Length of Lines: 200 # Lines: 4 Trench Width: 3 Treatment Area: 600 Type of Filter: rock Soil Boring: yes Tile Size: 4 Under Tile: 12 Perc Rate: Setback DF-Bldg: 20 DF Ht above Wt: 3 Soil Type: clayey sand & gravel Limitations: WELL DATA Setbacks - Well-Tanks: 75 Well-DF: 75 Report in File Pump Type: Depth: Diameter: Method: INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 6/27/78 add 1st tank (1000 gal),DF (600 sf) s 6/24/78 500 5/22/80 no surfacing 2 8/21/81 1500 7/22/86 no surfacing 2 10/11/82 1000 8/19/88 no surfacing 2 10/1/88 1500 9/25/90 no surfacing 2 2/3/93 2000 10/23/92 no surfacing-pump tanks 2 7/27/98 1200 10/18/93 conforming-no surfacing 2 1/21/00 1800 10/19/94 no surfacing 2 2/10/00 2000 11/2/98 no surfacing 2 3/13/00 1500 )._y-oc) (ocnecTc� St6/27/00 1500 103S- CoN.on3 Lake, Rot + Eli 51 <)-)\ A Q C D \ 3�'6 433 TIMI - - 6 a5'6 Tm� - - 3s6 - so 4_16 'D [�i3 - - 647) s0'6 0.4 . /r0 CITY of ORONO s, Municipal Offices Street Address: Mailing Address: N, kesigOV. 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: 4 ona_ i � Address: 1005 Old Long Lake Rd. Permit #'s: 5213 Dates: 6/22/78 Contractors: Jerry Johnson (This is [1/] an existing system [ ] new construction) . SYSTEM COMPPLIANCE (1-3) : 2 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. .) Compliant System: Does not meet all current City standards for new construction, but in lJ most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [X] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. CInspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is [X] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) (... INFIELD CONDITION (11-14) : 11 ( 11 ' Drainfield is dry, no surfacing evident. "12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: r/- . - / � Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 ,4, CITY OF ORONO O Municipal Offices O � Post Office Box 66 '_,; to' Crystal Bay, MN 55323-0066 P ON-SITE SEWAGE TREATMENT 41 �� INSPECTION REPORT 9k'Esxo�' Owner: ) LL4tw1 4- Address: /0 -ad/i tL i Permit #'s: a Lc Dates: h—aa?g Contractors: ,)e JV/) City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is .04-an existing system ( ] new construction) SYSTEM CONFORMITY (1-3): GA 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic?/-i-has or I ] has not been identified at this time. If the limiting soil characteristic has not been identiied, this classification may be subject to revision.) TANK CONDITION (5-10): A) Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): ') Dr field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): ///ppp��� POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): / (�.-� COMMENTS: / 1 12— dgifir — / ✓, !//,'/ Date of In pection Sep System ns•ector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner At CITY OF ORONO 0 Municipal Offices O O Post Office Box 66 4io'_ Crystal Bay, MN 55323-0066 A , P ON—SITE SEWAGE TREATMENT Y0140 s 4, itilA..A1Nel .' r INSPECTION REPORT 1 A 0 k'EsHa�' Owner: J/iiz ,r � i�.lJ Address: / h4 /"'" Permit #'s: /J Dates: 6/JQs-- Contractors:) )/ -71/1,1- City 1-'+ _�'\ City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is , &an existing system I ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristichas or I ] has not been identified at this time. If the limiting soil characteristic has not been ident i , this classification may be subject to revision.) TANK CONDITION (5-10): T�a{� inspection indicates: (,S' Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): // Dr field inspection indicates: Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): COMMENTS: /lam/�`�3 �% . d-_:/i/ . , Da a of Inspection S ' is System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O /1/; IMunicipal Offices OE O Post Office Box 66 �_ ka._ Crystal Bay, MN 55323-0066 a f ON-SITE SEWAGE TREATMENT 1 (4 INSPECTION REPORT yrkA Owner: /lA AGy RA Address: /w.J vu 2000 i 4. Rd. Permit #.9: 5;05 Dates: 641-70 Contractors: -/i7724/110r\ City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is [ an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting[[soil characteristics. (The limiting soil characteristic [ ] has or `[�u has not been identified at this time. If the limiting soil characteristic has not been identified, this c'llassification may be subject to revision.) TANK CONDITION (5-10): —f� Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. ) . 0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). �C1If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): /l 7D ' field inspection indicates: Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): / I/ I•� COMMENTS: `,�,' •'•i/' ro , !' ,rte k - ic-a. ord cid I i h/ Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner