Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2003-P06666 - new structure
r PERMIT CITY OF ORONO Permit Number: 2750 Kelley Parkway - PO Box 66 P06666 Crystal Bay, Minnesota 55323 Permit Type: New Structure (952) 249-4600 Date Issued: 8/28/2003 SITE ADDRESS: 800 Old Crystal Bay Rd N Long Lake,MN 55356 PID: 28-118-23-43-0010 DESCRIPTION: Construction Type VN Proposed Use: Institutional-Schools BuildingCensus Code 327 Permit Class: Permit Type: New Structure Permit Sub-type(s): Building Undefined DETAILS: Approved per resolution#: Separate permits required: Electrical(state) NOTICES/REMARKS: r _n___ttt r__ti_ c tnnn /n__ _ c-._ i o_ c.._—_ citi FEE SUMMARY: Permit Fee: $ 321.25 Valuation: $ 19,550.00 Plan Review Fee: $ 208.78 State Surcharge Fee: $ 10.30 TOTAL FEE: $ 540.33 APPLICANT: Structral Builders,Inc. OWNER: Orono School District 278 12924 First Street PO Box 46 Becker,MN 55308 Long Lake,MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. * -.. \'4. ‘ jrgk-OIL) APPLICANT PERMITEE S' TURE ISSUED BY SIGNATURE Copies: 1-File(Siinitures Required). 1-Applicant, 1-Monthly Reports, 1-Assessin2, 1-Finance Page 1 V. GJu x (� IP(PL.C' Total Fee: $ 5-L �Q� Date Received: Entered By: y._ \ Pe4it#: / /g/ () 3 • CITY OF ORONO - BUILDING PEttMIT APPLICATION All information must be submitted in full before plan review will be started. (please print all information) ------- ---------------------------- —_------------- THE APPLICANT IS: (ciirrcclle one) AVNERDDR CONTRACTOR JOB SITE ADDRESS S''S u 0 id(d y s 4 ( Bal led A) ZIP: 63-3C-1> Orcv► 6 M Dr.no 645€1o.0 Assoc-icu of NAME OF OWNER: -/o TWA Pa.f�„�yc,,,�s I� PHONE: (home) (l 2 'I't Z- q3 d l C J s3" 54nle Lam.-6(A- (work) 4,i z 33.1—q cat) MAILING ADDRESS: Akcioi /'(e r, CITY: /Vi ZIP: 5-S'3 s — Vc' Jt=rde G1z - 32S - 02,31 CONTRACTOR: ClYliAlit Y4.-( f7(4,1 Le i ; j�c. PHONE: 800 - `� YL — U1-t'0�y '` CONTACT PERSON: Pc' J' �5ec.M r 1 MOBILE/PAGER: Co Z - 2-)ci - (r�() 7 MAILING ADDRESS: t 2-61Z4-1 t - Sf. kcice r CITY: m/j ZIP: 30i STATE LICENSE: # ARCHITECT/ENGINEER:6 YL.“/1t d uk 1; 1 f S Zig PHONE: g60 - Z, - (t 0 9 MAILING ADDRESS: Sc Q CITY: ZIP: NAME: `; E? REGISTRATION# TYPE OF WORK: New Addii Move Remodel/All _ 9 PROPOSED WORK(describe in detail): cunt t`w` '14 e_cf c+r J � Cu.rlS cv, t,e Ioettil Zc 41 STORIES: / SQ.FEET OF E (p 2_ -3,4 ) S � gL q] NO. OF BEDROOMS: GARAG: ESTIMATED CONSTRUCTION VALUATI i' IIS Oz.) I hereby apply for a building permit and I acknc ,tte and accurate; that the work will be in conformance Ld with the State Building Code; that I understand this is not a p.rmit and work is not to start without a permit; and that the work will be i accord. ith the approved plan. Pr . APPLICANT'S SIGNAT ' . i ,�,,;�� DATE: 111 C G, NOTE! Parade of Homes events require separate , rmit approval by Police Department and City Council 60 days prior to the event. Non permitted events will not be allowed. 5 w ' Sec.13.04 RIGHTS OF SUBJECTS OF DATA Subd. 1. Type of data. The rights of individual on whom the data is stored or to be stored shall be as set forth in this section. Subd.2. Information required to be given individual. An individual asked to supply private or confidential data concerning himself shall be informed of: (a)the purpose and intended use of the requested data within the collecting state agency,political subdivision,or statewide system;(b)whether he may refuse or is legally required to supply the requested data;(c)any known consequence arising from his supplying or refusing to supply private or confidential data;and(d)the identity of other persons or entities authorized by state or federal law to receive the data. This requirement shall not apply when an individual is asked to supply investigative data, pursuant to section 13.82, subdivision 5, to a law enforcement officer. The commissioner of revenue may place the notice required under this subdivision in the individual income tax or property tax refund instructions instead of on those forms. Subd. 3. Access to data by individual. Upon request to a responsible authority,an individual shall be informed whether he is the subject of stored data on individuals,and whether it is classified as public,private or confidential. Upon his further request,an individual who is the subject of stored private or public data on individuals shall be shown the data without any charge to him and,if he desires,shall be informed of the content and meaning of that data. After an individual has been shown the private data and informed of its meaning,the data need not be disclosed to him for six months thereafter unless a dispute or action pursuant to this section is pending or additional data on the individual has been collected or created. The responsible authority shall provide copies of the private or public data upon request by the individual subject of the data. The responsible authority may require the requesting person to pay the actual costs of making,certifying,and compiling the copies. The responsible authority shall comply immediately,if possible,with any request made pursuant to this subdivision,or within five days of the date of the request,excluding Saturdays,Sundays and legal holidays,if immediate compliance is not possible. If he cannot comply with the request within that time, he shall so inform the individual,and may have an additional five days within which to comply with the request, excluding Saturdays,Sundays and legal holidays. Subd.4. Procedure when data is not accurate or complete. An individual may contest the accuracy or completeness of public or private data concerning himself. To exercise this right,an individual shall notify in writing the responsible authority describing the nature of the disagreement. The responsible authority shall within 30 days either: (a)correct the data found to be inaccurate or incomplete and attempt to notify past recipients of inaccurate or incomplete data,including recipients named by the individual;or(b)notify the individual that he believes the data to be correct. Data in dispute shall be disclosed only if the individual's statement of disagreement is included with the disclosed data. The determination of the responsible authority may be appealed pursuant to the provisions of the administrative procedure act relating to contested cases. DATA PRIVACY ADVISORY In accordance with M.S. 13.04, Subd. 2, "Rights of subjects of data", we would like to inform you that your request for a permit or license from the City of Orono or any of its departments may require you to furnish certain private or confidential information. You are notified that: 1. The information you furnish will be used to determine your qualification for the permit or license requested. 2. You may refuse to supply data, but refusal may require that the City deny the permit or license. 3. The information may be shared with other local, state or federal agencies to the extent necessary to process the permit or license. 4. If your requested permit or license requires Council action to approve, some information may become public. 5. You have certain rights under M.S. 13.04(available upon request) to review private data on yourself. 6. Your full name is required to process this application or permit. II - t Oil 5 4 faifrvl s r First Middle Last V ec5 s vie_ Address City State Zip Phone I understand m ights as stated v . Signature 6 a CHECK OFF LIST FOR ISSUANCE OF PERMITS FOR OFFICE USE ONLY ADDRESS OR LEGAL: 0 b 0(✓.) C 2-Ai 51744- ALf (2- PID: , DESCRIPTION OF WORK: ( .,te es s, s;wr•,� Ark. <7.10.4./ ,Sater") ZONING REVIEW BY: I DATE APPROVED: R . L7- 63 BUILDING REVIEW BY: �_Ri/ DATE APPROVED: g -27 -°3 FEES TO BE CHARGED: Misc. Fees Calculated By: PERMIT Yes ✓ No PLAN REVIEW Yes No SEWER CONNECTION STATE SURCHARGE Yes ,/ No WA I'ER CONNECTION INVESTIGATION FEE Yes No PARK FEE SAC Yes No SITEINSPECTION Number of SAC Units OTHER (specify) ZONING CHECK LIST Zoning District: Fire Department: Post Office: School District: Lot Area: Sq.ft. Acres Width Depth Survey Submitted: Yes t( No Date of Survey: (o.t -01 Proposed Setbacks: Front(Lake): 7 0° f' Right Side: 2b 4* Rear(Street): 4,0 • " Left Side: 3 0 0' Adjacent Structures: 35 Wetland: N /i4 Building Height: Def. Hgt. es,t4- Peak Hgt. Lot Coverage: pf �f. Grading: Staff Approval Date: By: Council Approval Date: Septic: Staff Approval Date: By: Zoning File: # — Resolution: # Resolution Date: Shoreland District: ", Avg. Setback: Bluff Setback: Lot Coverage: Existing Proposed Hardcover: 0-75' 75-250' 250-500' 500-1000' Hardcover Variance Required: Yes No Date of Council Approval: REMARKS(in house): 7 • BUILDING REVIEW CHECK LIST UBC: S-f M CONSTRUCTION TYPE: AMMO. '4 N Sq Footage $Per Sq Ftg Basement x = 1st Floor x = 2nd Floor x Garage x x = TOTAL Estimated Construction Value: $ 19. 537) °Q Inspections Required: Work Requiring Separate Permits: Site Plumbing Fire Hardcover Removal Mechanical Water Connection pc Footing Septic Sewer Connection oc Framing Fireplace Lawn Irrigation Insulation (Masonry) Other Wall Board (Mfg.) Well(State Permit) nc Final Grading/Filling ,C Electrical (State Permit) Other REMARKS(IN HOUSE): • REVIEW BY OTHERS: DATE: Access: Existing New Access Approval: Date By: REMARKS (TO BE NOTED ON PERMIT): M. 8 Structural Buildings Inc. January 28, 2003 12924 1st Street, Becker MN 55308 Quote Good for 30 Days Orono ball field#2 <Customers Number> �j'"d'fltA� ��_ed <Customers'Address> ORONU ' <Customers City, ST Zip> Customer's Fax Number <Customers Fax> 1 - -ti c I(I, Building Design 54 ft z 38 ft x 9 ft 0 to Deluxe Trim Package 1i9 ft o.c 401 Live Load Trusses 40k'Engineered Purlins Ceiling Loaded Trusses 2x4 On Edge 9 ft o,c Side Columns 2-1/2 EZ Seal Nails in Roof 5 ft Column Embedment Metal to Wood Wall Screws I 4.00/12 Pitch (Sides) 6x6 SYP S4S .60 Poured Footings 2x8 Grade Board (Enda) 6z6 SYP S4S .60 2x6 Side Glrta Accessories and options to the above building design. O I 29ga Standard Roof Panel Pabral Alu-Tuff O 1 29ga Standard Side Panel Pabral Alu-Tiff O 2 Boxed Eave(s) Size per Side--> 12' Boxed Eave 12' Boxed Eave • 2 Boxed Gable(s) Size per End--> 12" Boxed Gable 12' Boxed Gable • 4 Walls of Wainscot 2 Side(s) 2 End(s) 4 3 Ovrhd Frameout(a) 9x7 O 3 Header(s) 8 Ventilation Package 38 If Plyco Continuous Vent O I Service Dr(s) 6100 White 3' O 1 Service Dr(s) Standard Door Knob O 1 Service Dr(s) Latch Guard Kit O 3 P.9x7 Uninsulated Overheads Material,Tax,Delivery,&Constructed Winter Const O Warranties: 4 60 years on partial treated glued laminated columns against rot, Insect attack,or delamination S. 40 years on treated squares(6x6 S4S SYP)against rot or insect attack 4, 25 years on paint system against fading or chalking--30 years on paint system's film integrity v 6 years on roof leakage due to workrnal1d1lip or materials failure O 1 year on all other materials and workmanship Thank you for considering Structural Buildings Inc. for your construction needs. Sales Representative Toll Free: 800-382-0409 }Ionic Phone: 0 Fax: 763-261-5434 Cell Phone: 0 r m_�� 1 94-7 ,. v..) C., W L Quote CITY OF ORONO Id1432;nd* 1/2812003 BUILDING P.,. i IJ7LAN REVIEW INSPECTOR ? . (�iGw.__ DATE._ i '2-7- / _PERMIT No.___,____ 'APFF OVt_D A J SUisMiT T E+D El APPROVED\•,I 1!,co,ii?ECT:ONS AS NOTh,D ❑ NOT APPROVED••-CC iREC T&RESiJE..!!T 'These comments are for your inlornal!an. A!! work that L3 done In!t::. :'tr. Gonne kith a:! , i.::.i1ng and zonir.o coda Requi r penis inc'uding itams not specifically noted in this review, _.. ICC:L'O TUIC DI AM GFT ARI GITF AT Al I TIaICe O i Warranty - ALUTUFF ALUTUFF .,,sliolls,,,,,, • 30 Year Warranty Film Integrity for Walls and Roofs • 25 Year Non-Prorated Paint Warranty Paint System • 25 Year Warranty against Fade and Chalk for Walls and Roofs •.10 Year Edge Rust Warranty against Acid Rain TOP COAT P ( RIMER COAT PanelSpecifications ZINC PRE-TREATMENT G90 GALVANIZED • High Quality Prime Metal • Anti-siphon groove for optimum weather tightness BARE STEEL • UL 2218 Class 4 Hail Impact Resistance • UL 790 Class A Fire Resistance Rating • G90 Zinc coating '` • 29 Gauge Steel Manufactured By: < K BACKER COAT • Panel net coverage 36 inch-panels overlap FABRAL PRIMER COAT Available in: ZINC PRE-TREATMENT - 17-Colors G90 GALVANIZED Gable/Rake Ridge/Peal AG-1,4 SRD-002/AR-2 Flashings /Trim Parts Zee 0 SDA-410/AZ-2 G ^ 4 Eave SET 103/AE-1 Outside I -- -"uu", �1' Corner II SOC-101/AC-1 -- U ` I Sliding Door IL IA Inside Track Covers Base Guard i Corner STC-504/AH-3,5 SBG-202/ABG-1 SIC-102/AC-2 Drip Cap Endwall SDC-203/AD-1 SES-301/ASW-1 J-Channel Sidewall SJT 204/AJ-3 SES-301/ASW-1 ALUTUFF II Paint System Warranty - ALUTUFF II TOP COAT • 25 Year Non-Prorated Paint Warranty PRIMER COAT • 25 Year Warranty Film Integrity for Walls and Roofs ZINC PRE-TREATMENT • 25 Year Warranty against Fade and Chalk for Walls and Roofs G60 GALVANIZED Panel Specifications BARE STEEL ( • Quality Prime Metal \\ • Anti-siphon groove for optimum weather lightnessic • UL 2218 Class 4 Hail Impact Resistance r '� BACKER COAT • UL 790 Class A Fire Resistance Rating ` PRIMER COAT • G60 Zinc coating • 29 Gauge Steel ZINC PRE-TREATMENT • Panel net coverage 36 inch-panels overlap G60 GALVANIZED Lancaster Plant: Marshfield Plant: Gridley Plant: 3449 Hempland Rd. 1820 East 26th St. Route 24 West FABRAL Lancaster,PA 17601 Marshfield,WI 54449 Gridley,IL 61744 Phone: (800)477-2741 Phone: (800)528-0878 Phone: (800)451-3974 Fax: (800) 283-4289 Fax: (715) 387-2424 Fax: (800)289-3383 Printed in the U.S.A. AMX-102©2000 FABRAL 12/00 a i !Euramax company (9835648) Structural Buildings Inc. January 28, 2003 12924 1st Street, Becker MN 55308 Quote Good for 30 Days Orono ball field#3 Customer's Number <Customers Number> CCOI'i CPr75(t,1/N <Customers Address> - 0 4 001/WI CQV'- <Customers City, ST Zip> Customer's Fax Number <Customers Fax> Building Design 12 ft x LE.6 ft x 8 ft 0 in Deluxe Trim Package ORONO COPY 7.5 ft o.c 40k Live Load Trusses 400'Engineered Purllns 7.5 ft o.c Side Columns 2-1/2 EZ Seal Nails in Roof Ceiling Loaded Trusses 2x4 On Edge Std Column Embedment Metal to Wood Wall Screws 4.00/12 Pitch (Sides)6x6 SYP S4S .60 Poured Footings 2x8 Grade Board (Ends) 6x6 SYP S4S .60 2x6 Side Girt' Accessories and options to the above building design. • 1 29sa Standard Roof Panel Fabral Mu-Tuff 4 1 29ga Standard Side Panel Fabrai Mu-Tuff 4 2 Boxed Bave(s) Size per Side--> 12"Boxed Rave 48" Boxed Pave • 2 Boxed Gable(s) Size per End--> 12" Boxed Gable 12" Boxed Gable • 4 Walls of Wainscot 2 Side(e) 2 Bnd(s) 4 1 huff face in roof • 3k serving windows 4 1 eyebrow 4 Ventilation Package 25 If Plyco Continuous Vent • 1 Service Dr(s) 6100 White 4' • I Service Dr(s) Standard Door Knob • I Service Dr(a) Latch Guard Kit - Material,Tax,Delivery,&Constructed Winter Const 4 Warranties: • 60 years on partial treated glued laminated columns against rot, Insect attack,or delamination • 40 years on treated squares(6x8 S4S SYP)against rot or insect attack • 25 years on paint system against fading or chalking--30 years on paint system's film Integrity • 6 years on roof leakage due to workmanship or materials failure • 1 year on all other materials and workmanship Thank you for considering Structural Buildings Inc.for your construction needs. Sales Representative Toll Free: 800-382-0409 Home Phone: 0 Fax: 763-261-5434 Cell Phone: 0 )t A6 ? LA 0 s4 I' 51 M , lis A Quota Id 14321n0002 1/2S/2003 m (5 ) 7 91:21., 0 3 TIME CITY OF ORONO CALLED I � 1-C ��QQT�I INSPECTION ,ICE SCHEDULED! _ PERMIT NO. f IJ 040(P COMPLETED ADDRESS CPDD d1/ ✓ C/"ys74 -1 5- 1Qc/ OWNER CONTR. -:a•r.iA7,, ►=',ali+p..1__A TELEPHONE NO. 3 2 b- 2(aO - 260 4 X(icI 747nelucel,., • SCRIPTION Foo T i n C5 OOTING 11 MECHANICAL D 18 EXCAV/GRADING/FILLING Q : FRAMING 13 MECHANICAL FINAL 19 LAKESHORENVETLANDS Cl) 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP LW 09 PLUMBING RI 23 SEPTIC FI AL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL Z OWNERICONTRACTOR TO MEET YOU:_YES_NO oy COMMENTS: cc cc Li, II ea f ou cr,()- c.r. ase)\--e -cOCA 1IQI_Eft CIC, !CZ10 AS.)cc0 u. Lu cc Q W Z W cc d W ❑ RK SATISFACTORY:PROCEED ❑PROJECT COMPLETE CCW CORRECT WORK&PROCEED CI ISSUE CERTIFICATE OF OCCUPANCY C) 0 CORRECT WORK,CALL FOR REINSPECTION TEMPORARY 0 BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN 0 STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlContra site: Inspector. f 0,1 White Copy/Inspector's File Canary Copy/Site Notice . . - . it • N, 9 7-. f \ 2 i> 4. Plyco Vent t Cap w/2" t Down peak purlin :8" Boxed Eave / I , 12 ! n 2 fl.i , Btr SPE Purlins 1 i _ .i I.5---. --—-- ---- cl : c , _ . ), 2x1 on edge covering multi Sr)pans / \ • •L.:... • i 2 2 / l 0 i i' ..---- E ! i'l • 2 1 z lir ' 2 1 i • -ft' Conttuatam Ridge Vent 0..if i ,S1 68 11111111111111111111.11:____---------------‘ - - ' 411111111111111111111110,._ 68 --%3 , 0' ...111111111111111111 / tiL /K lc I Loading 1011-5 Truss -5 . 4c le, i i, ......- __,--., 3a,c• \ --- 4 __---- ker I i . i ; 12" Boxed Eave I ' 1 r ; , _, T-1 1/2" 2x6 :T3ide C..nrt,,-, - i o., 0 I I 0- Floor Plan _ C•1 Transition Trim `14) 36"---------- i IP \ ) i i 31" Wainscot - __ tit 1 i Cent-moats 12.dge Vent f ---- II -0- I ( 8 \ ii C•1 -------'---,,_______..._ See Detail i------1 I' 4' Egebrem _ II : ; --_ \ \ ----- \ All - ; I . 6x6 -.60 Trtd. 51S SIP Columns-- > ;Cr 1 32" oo See DetailAi----L * A il Ili IT Boxed Gable , . . - L ; •1,!-..,7,:-T!) -- CITYOF ORONO ______ wiLDNtlopE1 LAN REVIEW 2 'A — — ---7 T`'' -27 it:, ,PEPtal.NO. /1--- --:i\ ili lEtILIPI/E!,C1;;Panr;78tOVE )AS SL:,.. 1-TED 41:3-1P:i.T.C;VEri cliTH GCRREOPONS AS NOTED E Th,.-,,,cctvirr:nt 3 t:.: ,::.for ynt.tr infomtalli.t!rt. Ali +,t/oii,.st-icill he done in ''.1.; coinr.,::-)rice .,.•!th ;..-,r,d zoning code. Req..!,i.:7-;;!:nto 71;;;Jt.!ing itorns riot 5peo:licJiiy cloted in this review. KEEP THIS PLAN SET ON SITE AT ALL TIMES k - 1 _ • "Way 51'k , . ) — F 2'-1 1/2" 8'-II" 2.-1 1/2" 8.-11" 2.-1 1/2" 8'-H" 2'-1 1/2" t 1 i , I I % % II II 2" Boxed Eave i -----_-- 1 N : I DI I ' DI • I I •"-- •• ii 1 I 1 2 Pk - II 1/8"//LVL Header 2 Ply - II -1/3" LVL Heade9 12 Ply - II-•'-y8" LVL 1-1Z-e I = I 1 •N 1 / • / I 1 \ 1 TO 1 I (A1 1 / '/, q ) 1 ":') I I --764) •-•:.s. 1 , -.- 1 1 1 \\ 1 1 1 1I „,,/,../ 1 1 1 \\ 1 1 . I , \ 1 I , 0 .1 //, //-• 43 II \ _ i ii, ; - 7` _1 I L _J ----- , 7,- I L \ 1 \\ ._I ‹ 1 1 I 6i co I' L3 I \\ \ • \, _ / 13)I I 1 I I / / / f),1 7.."- \ \' X I 0 \\ in! • 1 /, \I ,, i / - i_7_1 7 . , . . / -. o . , i ...• ...- J--- Continuous Ridge Vent - I 01 Co I I f\I I I I I \Q.) 76 \ V" // Ho \.. I ° \\ \\ Z 77 i'„, //// I I I 13 \ 77 ,./ ' •, / / ' N ' 77 / I /, ' III . II x \ Ni 1 \\ y // 2x, Corner Braces ical 1 1 tf •\ / Windbracesorners Typical 1 Corners 1/ 1 I 0 1 1 TypLI CI I T I II II 7,,,,7 . /•/ / I 1 1 1 1 1 1 -7- \• \ // 31 1 I 1 ,,,,1•7 \ Wainscot All Around Building 1 I I 1 i N . i _ _ .,, . .. ._ //// _ELL_M-'• 4i. ! 12" Boxed Eave i 1 - - -` -10 1/2" : I i 9'-0" I 9 ,.-0" 8.-10 1/2" .? i ,t. ,f-- „‘ W '''''• 1 ‘. 1----- I i- oo-r I ' Ion .., 2 : I '. ....___--• 5c.-..?1,-f: i/ "--r-O” • ' 571-my 1,. \..94 2-e-6 "2.__ Plyco Vent t Cap w/2" t Down peak purlin 2 12 19 i • 4 I 36 42 I .Btr _SYP .or 1450 MSR Purlins 53 t;' ; Rte, • 10... 2x9 on edge covering multi Spans \ _ \ 3 8 i `i'� 10• 1 121 \,0Truss Loadng 40+2-5-5 138 See Detail H\' 155-. x''' Catwalk lax Spacing 10' ` '.a/12 Jack \ \ O 12" Boxed Gable 2x6 Side Girts , i N! _ • O O a • - i Transition Trim a 36" -\ i i 31" Wainscot _------›. i o- B n cs See Detail © - - --- - --- - - -- I i,. \ \ Lx6 -.L^ Trtd. S°F. 'X!' Columns :o 1 Continuous Ridge Vent �F; ./ "E 1'. ��, Wall Section See Detail ( � t - - — - --- — I2" Boxed Eave I� I I II I L. 11 I ;