Laserfiche WebLink
11% <br /> y1 F y1 O R A NDU M <br /> r WOLD ARCHITECTS <br /> AND ENGINEERS <br /> 305 ST. PETER STREET <br /> ST. PAUL, MN 55102 <br /> 651.227.7773 <br /> TO: Meeting Attendants FAX 651.223.5646 <br /> 25 SOUTH GROVE AVENUE <br /> FROM: Tearinie Nielsen SUITE 500 <br /> Eiciy. II. 60120 <br /> 847.608.2600 <br /> DATE: May 8, 2001 I' x 8-+7.608.2654 <br /> www wOI.UAE.COM <br /> COMM. NO: Comm.No. 01059 MAII.N W OLI)AIi.COM <br /> SUBJECT: Orono Public Schools,ISD 278-Fire Alarm Remodel <br /> High School and Intermediate/Elementary School <br /> Meeting at Orono High School and Intermediate School to discuss fire alarm system <br /> requirements. <br /> Attendants: <br /> Bill Meyer,Orono Fire Marshal <br /> John Ostlund,Coordinator of Building and Grounds—Orono Schools <br /> Vaughn Dierks, Wold Architects and Engineers <br /> Tearinie Nielsen, Wold Architects and Engineers <br /> The following items are comments and recommendations for the Fire Alarm <br /> Systems based on Bill Meyer's review: <br /> High School <br /> 1. The existing fire alarm system will be replaced with a fully addressable system <br /> including horn/strobe devices installed throughout the building per ADA. <br /> 2. One new FACP will replace the two existing panels located in the mechanical <br /> room near the gym. <br /> 3. There will be(3)remote annunciator panels installed. There will be recessed <br /> FAA's located at the Music Room entry and the"Main Entry." A surface mounted <br /> FAA will be installed in the Maintenance Office. Bill reviewed and approved <br /> locations. <br /> 4. There will be manual pull stations installed only at the Kitchen/Maintenance area <br /> door,in the basement lab office,and the Main Office. The existing pull stations <br /> will be removed. <br /> 5. The exterior fire alarm horn will be replaced with a horn/strobe device. <br /> 6. Smoke detectors will be installed in the gym mezzanine area. Smoke detectors <br /> will not be required in the gym per Bill. <br /> 7. Heat detectors are not required in sprinkled storage rooms(Per Bill Meyer). <br /> 8. The basement open storage area will have smoke detection and horn/strobes <br /> located through the center of the space only. <br /> 9. Wold to verify sprinkler system for possibility of installing additional flow <br /> switches(FS)for each floor. The existing FS near the new media center will be <br /> connected as required. <br /> 10. The existing addressable devices located in the media center will be reconnected to <br /> new FACP. Existing devices to be reprogrammed accordingly. <br />