Loading...
HomeMy WebLinkAboutplan review checklist Ry Plan Review Checklist Non-Residential Note:code references Minnesota Rules and the 2000 International Building Code The following is a partial summary of plan review for non-residential structures and should include,but not be limited to the following items: Complies Zoning: Yes No N/A Site Plan-Submitted Front Yard Set Back: Rear Set Back: Side Set Back Conditional Use Permit New Building Size Location of Additional Buildings Location of Well Location of Septic Shoreland Setback High-water Elevation Notes Construction Documents Complete Submittals MN Rules 1300.0130 Permit Application Complete 1300.0120 Construction Submittals Signed By Design Professional 1300.0130 sub 1 Special Inspection Agreement Submitted Geotech Report Energy Calculations Notes Code Overview Use& Classification Building Classification 302.1 Incidental Use 302.1.1 & Table 302.1.1, 302.1.1.1 S 1+e1-G olAty Mixed Occupancies 302.3 Separated or Non-Separated Use 302.3.2 302.3.3 Occupancy Separations Table 302.3.3 " Complies Code Overview(cont.) Yes No N/A Building Occupancy Classifications Assembly 303 I Business 304 Educational 305 Factory 306 Hazardous 307 . Mercantile 308 Residential 310 MN Rule 1305.0310 Storage 311 Utility 312 Notes General Building Reauirements Scope MN Rules 1305.0501.1 ✓ Definitions.502.1 1/ Basements 503.1.1 Basic Allowable Height &Area Table 503 ✓ Height Modifications 504.2 ,✓ Multi Story Area Increase 503.3 ✓ Area Modifications 506.1, 506.2, 506.3 ✓ Unlimited Area 507 Notes Types of Construction Minimal Requirements 602.1.1 Combustible Material Allowed In Non Combustible Construction 603 ✓ Fire Resistance Rating Table 601 w/footnotes Exterior Wall Fire Resistance Table 602 w/footnotes Notes Fire Resistive Construction Fire Area Definition 702 Fire Separation Distance Definition 702 Exterior Walls 704 �- Projections 704.2 __G Complies Fire Resistive Construction (cont.) Yes No N/A Combustible Projections 704.2.3 MN Rules 1305.0704.2.3 Fire Resistance Rating Exterior Walls 704.5 Allowable Area of Openings- Exterior Walls 704.8 Table 704.8 ✓ Allowable Area of Openings- Sprinklered Exterior Walls 704.8.1 Table 704.8 ✓ Parapets 704.11 —� Opening Protection Doors, Shutters& Exterior Walls 714.2 Table 714.2 Fire Walls (Former Area Separation Wall) 705 Definition 702 Fire Walls Fire Resistance Rating Table 705.4 ✓ Horizontal Continuity 705.5 Vertical Continuity 705.6 Opening Through Fire Walls 705.8 Table 714.2 Fire Barrier(Former Occupancy Separation) 706.1 Definition 702 Fire Barrier Fire Resistance Rating 706.3 Fire Barrier Continuity 706.4 Openings Through Fire Barrier 706.6, 714.2, 714.3 Fire Partitions Where Required 708.1 Fire Partition Fire Resistance Rating 708.3 Fire Partition Continuity 708.4 Horizontal Assemblies General 710.1 • Horizontal Assemblies Fire Resistance Rating 710.3 Horizontal Assemblies Continuity 710.4 Penetrations–Definitions 702 Penetrations 711 Opening Protective 714 Duct Openings General 715.2 Fire Dampers Fire Protection Rating Table 715.3.1 Fire Damper Actuation 715.3.1.1 Smoke Damper Rating 715.3.2 Smoke Damper Actuation 715.3.2.1 Fire Damper Smoke Damper.Where Required 715.5 Fire Blocking 716.2 Draftstopping Floors 716.3 Draftstopping Attics 716.4 Notes Complies Fire Protection Systems vu.SI b r gv w t C Yes No N/A Sprinkler Supervising Station Definition ,),,��c�✓ 902.1 901.6.1 Fire Area Definition 702.1 Sprinkler Systems Where Required 903.2 Sprinkler Systems Required @ Basements 903.2.12.1 Additional Required Suppression Systems Table 903.2.15 Sprinkler Exempt Locations 903.1.1.1 Fire Alarm &Detection System 907 MN Amendments Notes Means of Ecrress L-0 c — -1-� (, �e 2� f Occupant Load 1003.2.2 Table 1003.2.2.2 Increased Occupant Load 1003.2.2.4 Egress Width 1003.2.3, Table 1003.2.3 Ceiling Height 1003.2.4 Exit Signs Where Required 1003.2.10.1 Means of Egress Illumination 1003.2.11 Illumination Emergency Power 1003.2.11.2 Guards 1003.2.12 MN Rules 1305.1003.2.12.1 Doors 1003.3.1 Size of Doors 1003.3.1.1 Door Swing 1003.3.1.2 Landings @ Doors 1003.3.1.5 Locks&Latches.1003.3.1.8 Stairways 1003.3.3 MN Rules 1305.1003.3.3.3 Stairway Landings 1003.3.3.4 ✓ Handrails 1003.3.3.11 MN Rules 1305.1003.3.11 Handrail Height 1003.3.11.2 r/ Handrail Continuity 1003.3.11.4 Handrail Extensions 1003.3.3.11.5 MN Rule 1305.1003.3.3.11.5 Exit Access General 1004.1 Exit or Exit Access Doorway Required 1004.2.1 Table 1004.2.1 MN Rules 1305.1004.2.1 Separation of Exits or Doorways 1004.2.2.1 Egress Through Intervening Rooms or Spaces 1004.2.3 Exit Travel Distance 1004.2.4 Table 1004.2.4 Common Path of Egress Travel Definition 1002 Common Path of Egress Travel 1004.2.5 , Complies Means of Eczress (cont.) Yes No N/A Corridor—Definition MN Rules 1305.1002 Corridor Where Required Table 1004.3.2.1 Corridor Construction 1004.3.2.1 Table 1004.3.2.1 Corridor Continuity 1004.3.2.5 Notes Exits General 1005.1 Minimum Number of Exits 1005.2.1 Table 1005.2.1 Buildings With One Exit 1005.2.2 Table 1005.2.2 Vertical Exit Enclosures 1005.3.2 Exit Enclosure Definition 1002 Exit Enclosure 1005.3.2.5.1 Exit Passageway Definition 1002 Exit Passageway 1005.3.3 Horizontal Exit Definition 1002 Horizontal Exit 1005.3.5 __r_ Exit Discharge Definition 1002 Exit Discharge 1006.1 _ Notes Complies Cross Sectional Drawing(cont.) Yes No N/A Foundation Insulation Type and Thickness, MN Rules 7670 Basement or Crawl Space Ceiling Height, R305, MN Rules 1309.0305 Size of Bottom Wall Plate,R602.3.4 Size of Top Wall Plates,R602.3.2 Size and Spacing of Wall Studs, Table R602.3(5), Table R602.3(1) Size and Type of Wall Sheathing, Table R602.3(1), R602.3(3)MN rules,1309.0703.8 Type and Thickness of Wall Insulation, MN Rules 7670 Type and Thickness of Vapor Retarder, MN rules 7670 Type of Weather Resistive Sheathing Paper, R703.2, MN Rules 1309.0703.2 Type of Exterior Wall Covering,R703, MN Rule 1309.0703 Type of Interior Wall Finish,R702.1, Table R702.3.5 ( Type and Thickness of Ceiling Insulation MN Rules 7670 Type and Thickness of Ceiling Vapor Retarder MN Rules 7670 Type and Thickness of Ceiling Finish Table R702.3.5 Wind Wash Barrier at Trusses, MN Rules 7670 Roof Truss Tie Down,-R802.11 Roof Framing Trusses,R802.10 Roof Framing Rafter, Table R802.4(2), R802.5.1(1) Roof Sheathing,R803.2.2, Table R503.2.1.1 Roof Eave Protection, R905.2.7.1 Roof Underlayment,R905.2.7 Type of Roofing,R905 Roof Ventilation Requirements,R806.1 Townhouses Meets Defmition R202 Unit Separation R321.1 w/exception Parapets R321.2.2 w/exceptions Structural Independence R321.2.4 Penetration of Fire Resistive Separation R321.3