Loading...
HomeMy WebLinkAbout2015-01240 - fire alarm system 111111111111 iiia 111111111111111111111 • , CITY OF ORONO * 2 0416 0 1 2 4 0 2750 KELLEY PARKWAY DAT ED: 09/24/2015 ORONO,MN 55356- A (952)249-4600 FAX: (952)249-4616 �4b ADDRESS : 450 OLD CRYSTAL BAY RD N PIN : 33-118-23-13-0020 LEGAL DESC : CRYSTAL BAY BUSINESS CENTER 2ND ADD : LOT 001 BLOCK 001 PERMIT TYPE : FIRE SYSTEMS PROPERTY TYPE : COMMERCIAL-BUSINESS CONSTRUCTION TYPE : ALARM SYSTEM NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. FIRE ALARM ENTER CONTRACT PRICE 1900 ENTER THE VALUTATION 1900 APPLICANT FIRE ALARM 73.99 STATE SURCHARGE VAL OTHER 0.95 GENERAL SECURITY SERVICES CORP TOTAL 74.94 9110 MEADOWVIEW ROAD Payment(s) BLOOMINGTON,MN 55425- CHECK 9103 74.94 (952)858-5000 Minnesota State License#: cont-TS000276 OWNER Jem Technical 450 OLD CRYSTAL BAY RD N LONG LAKE,MN 55356- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This •• it may be revoked at any ti for due cause. /sApp70?I/. / (7/-5— Applicant licant Permitee Signature Date Issued By Si nature Date t ,440 �T City of Orono FOR CITY USE ONLY P.O.Box 66 ti �� �OiVDate Received: Permit#C7tit Cir , 2750 Kelley Parkway Crystal Bay,MN 55323 Amount: $1—V—+V (952)249-4600 Approved By: 0 Charge Plan Review ce't4ki"s H o�� Recommends: Approval 0 Denial 0 CITY OF ORONO—FIRE ALARM OR KITCHEN EXTINGUISHER/GENERAL PERMIT (All permits must be approved by the Fire Marshall and/or Building Official) 1. All fire alarm systems,voluntary or required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association(NFPA)72 and 72E, 1996 edition,National Electrical Code and manufacturers requirements. 2. Permits are required for all fire alarm system installations. Permits can be obtained from the City of Orono-Building Official at,2750 Kelly Parkway Orono,MN or via phone(952)249-4600. Permits are also available online at: www.ci.orono.mn.us 3. Two sets of plans and specification sheets shall be submitted to the Orono Fire Marshal for approval at least 7 working days before start of installation and shall include: a. Specification data sheets on all components of system. b. Floor plans indicating locations of devices,fire alarm control panel,sub-panels,transponders, enunciator, interconnecting wiring and zoning. c. Power connections including source and branch circuit data. d. Type of back up power system. e. Fire alarm control panel shall be compatible with all devices. f. All components of the system shall be UL or FM listed for their applications. Smoke detectors shall be listed for commercial/industrial use. 4. All systems shall be addressable. Smoke detectors shall be photo-electric.No combination burglar/fire alarm systems are allowed unless approved by the Orono Fire Marshal. 5. Power supply for the system shall include battery back-up with a UL listed fire alarm panel. Alarm verification is required for all systems using smoke detectors. 6. The alarm system shall be audible above the ambient noise level in all areas of the building. Audio/visual signaling devices are required. 7. When central station notification is required or provided it must be through a UL or FM listed communicator or control panel. 8. If a smoke detecting system installed in the tenant space of a building is directly connected to the building fire alarm panel,then a. A zone on the alarm panel must identify the tenant space or zone of the building that the system is located(i.e.,second floor,west wing). b. A visual annunciation light shall be installed on the corridor side of the main door of the tenants space and activate when the detection system in the tenants space activates. 9. The system shall be tested in the presence of the Orono Fire Marshal for final approval. Appointments can be made by calling the Fire Marshall at(952)473-9701, 24-hours notice is requested. The test will include: a. Random testing of system devices. b. Random testing for system trouble and ground fault trouble. c. Correct operation of back-up power system. i `Pass Sr'e`�.�^y }• �'-�y���' l' C a ass A ❑ New ❑ Addition II Remodel ❑ Replace b Site Address: 450 Old Crystal Bay Road Owner: JEM TECHNICAL Mailing Address:450 Old Crystal Bay Road City: Orono Zip: 55323 Home Phone: 952-473-5012 Alternate Phone: .t6 7 443A0116-': 1 164MY®�sma ado i s u#'�g,..�..,� <uti. 4.�,�:�� f .. < .ttca:.�l- rF� ��_: vi.a Contractor/App.: General Security Services Corp. Contact Person: Ash Siyani Address: 9110 Meadowview Road State License#: TS000276 City: Bloomington Zip: 55425 Expiration Date: 07/31/2016 Phone: 952-858-5000 Alternate Phone: 952-858-5063 [t, R,KIMETP-Ettal: ❑X Commercial—Fire Alarm ❑ Commercial—Fire Extinguisher Fire S stems Permit Fire S stems Permit * PWy: ) * W () *Contract Price: $ 1900.00 *Contract Price: $ ❑ Residential—Fire Alarm Fire S stems Permit *Contract Price: $ eea k,� l°•,L da �x`i '.�. .�� .�0_- s I herby apply for a Fire Alarm/Extinguisher Permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the Ordinances and Codes required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association (NFPA) 72 and 72E, 1996 edition, National Electrical Code and manufacturers requirements;that I understand this is not a permit and work is not to start without a permit; and that the work will be in accordance with the approved plan. 09/22/2015 Applicant Date FIRE ALARM ACCESSORY );� SILENT fi 410 5104B Fire Control , KNIGHT Communicator - by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines—eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard—the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-328-0103. Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a 60 seconds, it will automatically " _� ,' six-zone fire control communicator switch to the other to report the 0 • s • a • providing digital fire reporting over failure. I • . ordinary telephone lines, The communicator will signal eliminating the need for costly activation, restoration and trouble leased lines. It's UL 864 and NFPA conditions on any of six inputs. If " 0 ;:.::seu 72 approved for monitoring local an application requires a different . WI evacuation controls. input configuration, the individual l As a stand-alone unit, it can be input styles may be changed by t' used to monitor: using a Model 7181 Fire Zone Model 5104B • Sprinkler systems for waterflow, Converter Module.The 7181 also supervisory, and gate valve allows use of two-wire type smoke Dual phone line interface Automatic tamper conditions. detectors, instead of the normal self tests every 24 hours with report four-wire contact type, for sent to central station. • Automatic fire detection systems automatic fire detection • Reports in SIA and most major for structures that are not applications. communications formats. required to have a fire alarm system but want property Features • 60 hours of standby power. protection (e.g. to call the fire • UL 864 Listed as an NFPA 72 • Operates on loop start phone lines department after hours). Central Station or Remote Station ahead of the building PBX system. • Monitors drycontact alarms, protected premise unit. • A single, programmable output is provided for alarm or dialer failed • FM approved.trouble and supervisory outputs,ry • Can be used as a stand-alone or as conditions(cannot be used for then transmits a separate code a add-on DACT. evacuation purposes). for each. The Model 5104B is fully • Six fully supervised inputs:one Class A(Style D)input,and five supervised. Its microprocessor Class B(Style A)inputs. constantly runs programs to • Downloadable for remote monitor AC, standby battery, zone programming. inputs and telephone line • Fuseless overload protection with connections. If a fault condition is automatic reset circuitry and fault detected, it sounds a local trouble indicators—eliminates the cause of audible and reports the condition to most field calls. cop FIRE ALARM ACCESSORY 51046 Fire Control Communicator Specifications Mechanical: Electrical Dimensions: 12.25"W x 14.5"H x 3.0"D Add-on Applications-UL Listed (31.1cm W x 36.8 cm H x 7.6cm D) Input: 120 VAC 60 Hz 40 watts Weight: 15 lbs.(6.75 kg) Current: Color: Red Standby 50 mA Alarm 135 mA Optional Accessories: Stand Alone Applications 5230 Remote Annunciator/Programmer Input: 120 VAC 60 Hz 40 watts 5561 Download Package Standby: 12 volt 7 amp hour rechargeable battery 7181 Fire Zone Converter Module 5230 Remote Annunciator(three maximum per system) 7860 Telephone Connecting Cord for RJ31X Jack(2 required) 6712 12 volt,7AH rechargeable battery Load: 60 mA standby 120 mA alarm Communication Formats: SIA,SK 3/1,Sescoa 3/1,Contact ID, Indicator Lights(LEDs): SK 4/2,Radionics BFSK Power On(Green) Approvals: Trouble Silenced(Yellow) UL Listed-UL864/NFPA 72 Central and Remote Supervising Until Trouble is Cleared/Flashing=Supervisory Station Fire Alarm System Service. Dialer Failure(Yellow) FM Approved Telephone Line Fault(2 Red) CSFM Approved Inside Cabinet at L1 and L2 Inputs MEA Telephone Requirements: FCC Registration#:AC698R-17462-AL-E RINGER EQUIVALENCE 0.0B Type of Jack:RJ31X(2 required) Model 5230 Remote The Model 5560 SKSS Alphanumeric Annunciator Downloading Package The 5104B can be programmed Allows for remote programming through the use of the optional and status checking of the 5104. • Model 5230 Remote Alphanumeric Includes a 3 1/2-inch disk and y �_ ,,� Annunciator. Programming options Silent Knight proprietary modem. u.� T if include:telephone numbers, Allows the installing company to i FIRE ALARM=== ANNUNCIATOR reporting format, account number, view the default programming, — — loop response times (electronic modify it, and if necessary, retard), test time, output activation, troubleshoot the system. Designed ® e®®®®® ""'-"" user and installer codes. System to be used on an IBM or programming is stored in a non- compatible PC. The downloading volatile EEPROM chip which is software also contains programs for reprogrammable hundreds of times. other Silent Knight downloadable Model 5230 The 51048 accommodates up to products. 5 1/4-inch disks available three remote annunciators via a upon request. four-wire connection.A quick- connect plug allows temporary connection of the annunciator for programming. FIRE ALARM ACCESSORY 5104B Fire Control -Apt, Communicator 120VAC 60 Hz UL-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Silent Knight Model(optional)5230 Remote Annunciator Alarm Contact (3 max per system) (N.O. Typical) 1 Trouble Contact Tel. Line#1 To RJ31X (N.C. Typical) Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Add-On DACT Application SILENT KNIGHT MODEL 5104B 120VAC 60 Hz 6 Channel Silent Knight Class A Input Communicator Model 5230 (supervised) (optional) Max 5 waterflow devices as per NFPA 72 Remote Annunciator (3 max per system) irt 0 Class B Inputs Wheelock (supervised) MB-G10-12-R Gate valve tamper or PIV supervisor-must connect O Tel. Line#1 To RJ31X normally open O Model 6712 12VDC 7 AN 06- Tel. Tel.Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Waterflow Application FIRE ALARM ACCESSORY 5104B Fire Control Communicator SILENT KNIGHT MODEL 5104B 120VAC 60 Hz Silent Knight 6 Channel Model 5230 Class A Input O Communicator (optional) (supervised) Remote Annunciator (3 max per system) — 0 0 Class B Inputs Wheelock (supervised) MB-G10-12-R Heat detectors,manual 8Tel. Line#1 ` (optional) pull stations and To RJ31X contact type - Model 6712 smoke detectors 12VDC 7 AH . Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries.The secondary approved digital communicator to telephone line(number)at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. central station over the remaining The communicator shall be able to The digital communicator shall provide phone line.A signal shall also be transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format(Security Industry Association). six supervised detection circuits.One phone service.The The alarm signals transmitted to the shall be Class A(Style D)and five shall control/communicator shall be able to g be Class B (Style A).The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches,gate valve supervisory failed first.If both lines fail,a local zones are in trouble. Restore!from switches,thermal detectors and signal shall sound. alarm or trouble shall be capable of contact-type smoke detectors communicating to Silent Knight, and intermixed as desired and permitted by The control/communicator shall have other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours.The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines,seize the phone line setting a program within the panel. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA `j KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are PN 350349,Rev Cl by Honeywell subject to change without notice.For more Information,contact Silent Knight ©2010 Honeywell International Inc. 12 Clintonville Road,Northford,CT 06472-1610.Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com Fire Alarm Systems I D285 Series Photoelectric Smoke Detector Heads (12/24 VDC) BOSk., Invented for Ii D285 Series Photoelectric Smoke Detector Heads (12/24 VDC) ► Commercial or residential applications MINA 111111.1111111 1 �, ► Two-wire or four-wire application,depending on base ► Chamber Check rapid-flash LED sends contaminated chamber reports I I ► Flashing LED power indicator ► Steady-On LED alarm indicator hi ► Modular design The D285 and D285TH detector heads detect the large • D298M 24 V Four-wire Addressable(POPIT) Master smoke particles which typically result from wood, paper, Detector Base (6 in. [15.2 cm] diameter) and fabric combustion.The D285TH smoke detector also • D298S 24 V Four wire Addressable (POPIT) Slave has a+135°F (+57°C) fixed temperature heat sensor. Use Detector Base (6 in. [15.2 cm] diameter) in areas where the ambient temperature does not exceed +100°F (+38°C).These detectors are compatible with two- wire or four-wire,12 VDC or 24 VDC circuits.Also Functions available are addressable bases for use on the POPEX Detection chamber operation bus. The D285 and D285TH smoke detectors use an infrared These detectors have two components: the detector base (IR) LED light source and a silicon photodiode to measure and the detector head.The base is permanently attached light in a chamber. In normal conditions the light Is and wired to a back box.The Interchangeable heads absorbed in the chamber.The presence of a significant quickly detach for replacement and cleaning without number of particulates allows the light to reflect to the affecting circuit wiring.The D285 and D285TH detector photodiode.After three consecutive measurements heads attach to the following detector bases: exceeding the threshold level, the unit signals an alarm • D278S 12 V Four-wire Addressable (POPIT) Detector condition.The detector can be reset from the control Base (6 in. [15.2 cm] diameter) panel,after an alarm condition is cleared, by interrupting • D287 Two-wire Detector Base (5.5 in. [14 cm] power. diameter) The detection chamber, designed for reliable smoke entry • D288 Two wire Detector Base ([6 in. [15.2 cm] characteristics, is protected by a micro-fine insect screen diameter) • D292 Four-wire Detector Base (6 in. [15.2 cm] to reduce dust accumulation and insect penetration and diameter) minimize nuisance alarms. • D293A Four-wire Detector Base (6 in. [15.2 cm] diameter) with Form C Relay • D293E Power Supervision Detector Base (6 in. [15.2 cm] diameter) with Auxiliary Form A Relay • D293S Four-wire Detector Base (6 in. [15.2 cm] diameter) with Sounder www.boschsecurity.com 2 I D285 Series Photoelectric Smoke Detector Heads (12/24 VDC) Chamber Check Feature Mounting To further reduce nuisance alarms,the D285 and D285TH The D285 smoke detector head and D285TH smoke and heads check their calibration.This Chamber Check feature heat detector head are parts of a compound device.The is automatic. If the head is out of calibration for a period detector base installs over a back box and contains all the exceeding 24 hours,the Trouble-Alarm LED flashes once wiring.The detector head attaches to the base by aligning per second, three times the normal rate. the head with the base and turning it clockwise. No tools Testing are required for installation other than the hex key used to Internal diagnostic test tighten the optional tamper screw. These heads have moisture-proof reed switches that react Wiring to an external magnet for testing. The magnet test The terminal block accepts up to 12 AWG (2.3 mm) wire. simulates a 4% to 6%smoke obscuration that places the detector in an alarm condition. This test results in specific LED and alarm circuit responses to indicate: Technical Specifications • Detector within calibration standards Environmental Considerations • Detector settings outside sensitivity standards • Detector not operational Radio Frequency No alarm or setup on critical frequencies in This test is especially useful in environmentally unstable Interference(RFI) the range from 26 MHz to 950 MHz at field or unclean areas. Immunity_ -- strengths less than 50V/m Sensitivity voltage test -Relative Humidity: Up to 93%,non_condensing_ These detector heads have a socket that accepts the Temperature(operating): +32°F to+100°F(0°C to+38°C) D1005 Test Cable.The D1005 connects to the detector Mechanical Properties head and allows a voltmeter to read the sensitivity of the device. Color: Bone white -- – — LEDs Dimensions(diameter x D): 4 in.x 1.25 in.(10.2 cm x3.2 cm) The D285 and D285TH have a built-in LED that flashes to Power Requirements indicate the device is powered.The LED latches on steady Current Two wire:depends on control panel that must limit the in an alarm condition. (alarm): alarm current to 100 mA maximum Four-wire:depends on detector base;refer to pertinent base specifications _ Certifications and Approvals Current Two-wire:0.08 mA at 12 VDC;0.09 mA at 24 VDC (standby): Four-wire(D293E):4 mA at 12 VDC or 24 VDC RegionCertification RMS Ripple 25%of DC input - i (maximum): USA UL UROX:Smoke-Automatic Fire Detectors Voltage(in Two-wire:8.5 VDC to 33 VDC (UL268 and A),UROX7:Smoke- put): Four-wire:10 VDC to 30 VDC Automatic Fire Detectors Certified for Canada(cULus) CSFM 7272-1615:0134 SMOKE DETECTOR- SYSTEM TYPE-PHOTOELECTRIC NYC-MEA 274-93-E,Vol.VII MSFM Hong Kong HKFSD Installation/Configuration Notes Note Smoke detectors are intended for detection circuits that protect people. Heat detectors are appropriate for circuits that protect property. • 1)285 Series Photoelectric Smoke D,,fec for Iie,ld, (12%24 VL)'') 13 Ordering Information D285 Photoelectric Smoke Head D285 Photoelectric smoke detector head;requires base. D285TH Photoelectric Smoke Head with D285TH Fixed-Temperature(135°F[57°C])Heat Sensor Photoelectric smoke detector head with heat sensor;requires base. Accessories D1005 Test Cable D1005 Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range DT-2 Detector Removal Tool DT-2 Use the DT-2 to remove,replace,or test the detector head D275 Power Supervision Module D275 Line supervision device for four-wire fire de- tection circuits www.boschsecurity.com SYSTEM . �$ SENSOR" • F R Indoor Selectable- E y E Output Horns, Strobes, and F Horn Strobes fort•; •,R:1 Wall Applications e - SpeckAlert@ Advance audible visible notification products s p Ecmcmert are rich with features guaranteed to cut installation times &any a IN c and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela • Field-selectable candela settings on wall units: 15, 15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, strobes,and horn strobes include a variety of features that increase 30,75,95, 110, 115,135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING `b) ® MEA1',<� / LISTED APP® approved 7 .1653 (intloor bobee) 7125125-1653166166(horn strosbes, 51011(chimes,horn strobes,horns) 3023572 MEA152-05-E clime strobes) 55512(strobes) 7135-1653:169(horns,chimes) SpectrAlert Advance Specifications Architect/EnineerS ecifications' r, t` 9� p '.�' aid:,. ??. �:.. :�� �; General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1718-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110, 115,135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UI;Max.Strobe Current Draw(m:F1 S r?06, ,•}'.• 'a 44 Max,'Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 :411-Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 163 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 4.7" ► 2.5''=. laRPOW ® ,. 5.6" 111 Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. 'High cd"refers to strobes that include 135,150,177,and 185 candela settings. T .SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 02014 System Sensor. .$ SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 Pr000cl•pecr¢ahyos subject lo change without name sit sys$erraenmccom for currant godret nIncludingtoatioIncludingthe latest version dills dela sheet. www.systemsensor.com AVDS10201.1/14 FIRE ALARM INITIATING DEVICE • SILENT Die Cast Metal 4110 KNIGHT Manual Pull Stations Silent Knight die cast metal manual pull by Honeywell 9 stations put quality and peace of mind in easy reach A manual pull station doesn't have to be fancy just tough, reliable and extremely easy to operate. Silent Knight's die cast metal pull stations are all three.they're the high-quality choice for fast, sure initiation of a fire alarm signal. Our manual pull stations feature rugged, die cast metal construction that lasts and lasts. they're available in sin- gle or dual action models.And the Silent Knight PS-SATK and PS-DATK pull stations are UL-Listed, CSFM Approved, and MEA(BSA)Approved. For outdoor use, a weatherproof model is also available. On your next job, make the high-quality choice—Silent Knight manual pull stations. For more information, or additional information on our complete fire products line, call Silent Knight at 1-800-328-0103. Description Operation -. The PS-DATK and PS-SATK manu- The single action pull stations are FRE FIRE al pull stations feature high-quality, operated by simply pulling the han- I die cast metal construction.They dle on the front of the Station as far are available in either single or dual down as it will go, at which point action configurations with SPST the handle locks into place and is switch, and terminal strip connec- easily visible from up to 50 feet.A tions.The normally open contact, scored acrylic break rod is also which closes when the pull station supplied with each unit for applica- is activated, is rated for 1 amp, at tions where it is necessary.the 125 VAC or 30 VDC.The contacts handle is reset by opening the sta- are gold-plated to avoid risk of cor- tion with a key, placing the handle rosion.All models in the series in the normal upright position and have been tested by UL for compli- relocking the station. SILENT KNIGHT ance to the latest requirements of On the dual action models, pushing the Americans with Disabilities Act the PUSH bar causes it to rotate (ADA). inward, allowing the PULL handle PS-SATK Features to be grasped in a one-handed Single Action Pull Station motion. The dual action models are • UL listed also supplied with break rods. Dual • CSFM approved action models are reset in the FIRE IRE • MEA(BSA)approved same way as a single action model. • ADA compliant • Weatherproof model approved The weatherproof version of the PUSH pull stations is provided with a gas- for outdoor use ket and die cast metal backbox I 1 • Single or dual action tapped on one end for 1/2"conduit, PU LL • Terminal connections for surface mounting. --- • Reset using the same keys as Silent Knight enclosures • Surface mount backboxes avail- – able (SILENT KNIGHT • High-gloss red enamel finish on die cast metal • Corrosion-resistant gold-plated PS-DATK contacts Dual Action Pull Station FIRE ALARM INITIATING DEVICE ti, PS-DATK and PS-SATK Die Cast Metal Manual Pull Stations Engineering Specification The PS-SATK and PS-DATK manual pull stations are die cast metal construction painted with red enamel.The pull stations contain the word FIRE in two locations on the front of the units as well as the Silent Knight company logo.Operating instruc- tion are clearly visible on the front of the units.These manual stations contain a key operated reset lock,using a lock plate actuator.The reset key and lock shall be the same as used on the FACP. These manual stations shall contain two terminals for connection to the conventional fire detection loops. Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. Specifications Ordering Information Switch Rating: 1 amp at 125 VAC,or 30 VDC. Model Description Pull Station PS-SATK Pull Station, Single Action,Terminal Dimensions: 4-3/4"H x 3-1/4"W x 1-1/8"D Connection, Key Reset Surface Mount PS-DATK Pull Station, Dual Action,Terminal Backbox Connection, Key Reset Dimensions: 4-3/4"H x 3-1/4"W x 2-1/4"D PS-SATK-WP Pull Station, Single Action,Terminal (cast and sheet metal). Connection, Key Reset,Weatherproof Box Color: Red with raised white letters,white PS-WPB Weatherproof Box PULL bar with raised red letters. Accessories: All models are supplied with one PS-BB Back Box scored acrylic break-rod and a key. PS-GR-12 Box of 12 Scored Acrylic Break Rods Wring Diagram - Terminal Pull Screw / 'Terminals To Fire O e Alarm To Next �*im Control Device or ELR Panel SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product Information up-to-date and accurate.We cannot cover all NI KNIGHT specific applications or anticipate all requirements.All specifications are sub- P/N 350792 Rev.C v. ject to change without notice.For more information,contact Silent Knight p 2014 Honeywell International Inc. by Honeywell 12 Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,please call 800-446-6444. www.silentknight.com DATE, , TIME. CITY OF ORONO CALLED INd- , �h. INSPECTION NOTICE SCHEDULED PERMIT NO. 2 /J ' 0/Xtee COMPLETED ''..Z-._it kt . , ADDRESS `1517 V I eS ( r7,J( . I-.Lz ' "``� OWNER fe"- i A TELEPHOIIE NO. CONTRACTOR G cam- S c-c=`..-i 4 y —Cc,-tet y 3..- DESCRIPTION /4l:�r-'--- LU ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL Q ❑ POURED WALL 0 PLUMBING RI ❑ EXCAV/GRADING/FILLING Q0 FOUNDATION WATERPROOF 0 PLUMBING FINAL El TREE REMOVAL ❑ RADON SLAB 0 MECHANICAL RI 0 SITE INSPECTION C 0 FRAMING 0 MECHANICAL FINAL 0 PROGRESS 1, ❑ INSULATION ❑ WOOD BURNER/FIREPLACE 0 COMPLAINT J %FINAL 0 WATER HOOK-UP 0 FOLLOW-UP W ❑ AS BUILT-SURVEY 0 SEWER HOOK-UP 0 HARD COVER REMOVAL v ❑ DEMO-SITE 0 SEPTIC INSTALL 0 FOUNDATION/REMOVAL Z OWNER/CONTRACTOR TO MEET YOU:4k YES_NO te)• COMMENTS: cc cc 8 4..._ si--,), .. ok ,(V,jj) ) CC 1),, ,.h sI,,,, ,_ 6___ K cy, W ,,.,j,,s___ \ .„. Q 1 2 W Z • W CC j d L kVORK SATISFACTORY:PROCEED .,PROJECT COMPLETE W 0 CORRECT WORK&PROCEED Li ISSUE CERTIFICATE OF OCCUPANCY O ElCORRECT WORK,CALL FOR REINSPECTION TEMPORARY u BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN 0 STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED 0 INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: , 6 SiCC„ Inspector. ,CA-''`'` ✓x.-._ e White Copy/Inspector's File Canary Copy/Site Notice 12 {i,.2_, 5-b/107 . . . Ma aRr§ i . • IIII �Z° ® E . MODERN OW •:.N': ZCs�G /I. 12� \ 1 -` SEMINS PIA LONinINNG : ° I ° 1•?/4. - d for Code -c -- . Review o o o o 1 Aye .rev c.7Ah of Orono , 22Rn2n rinnomwn 1 1 -1 fl >3 Compliance C►�1 EnNOTNOLRNI,N1 NrOma .OEt.GL : I—GA.r4j !W GA=L--�T_�.4� . l .•r`'p a Date �_ �_ 1 J TT_ I I - (I-...,..F `7 1 ,rn, WA ER I � SYS l °�� . i ! o ..o Reviewer III l I� ' 1 rµ SHIPPIN--• TA . =II= DEBURRING B TT.;❑ pm' /STAGING ms's— ❑ ❑ �.x 1JRR �'ti 0 • 1! ®dill I Tm I '^' a Imam VIISSIGIMI'O*OY SW q r.ww WAWA 1�� O '''..1N IO..O.,.MS IAM OF Of . MA,ISSM MI TM.I AL MAMA ME. AN 1111 I E 3 WWIc.n X6710 ". I frik AI I 3 M 1 . =11= . • ❑, .- �• GENERAL MECHANICAL NOTES =II= =Q— =0= L MALI VIM.'N. NNlCT9RST000i.Mtr, riL momNaTlwnwcaTpNswrtNnuwlmAwOInww.NFa.a oaTNanwL.EaPDORM HON 0.3PLU M. ..--- �., a nsxsNuo.NTw.rrWLAYIN UMSASMO. COORCI L/E N ■ FRREN.naTluw .NN o ELECIA A.NIO mw,NOOMNACTONi ii, a OFNNEREO13'OK CI 103•233.M...111.m00100010 CT 000W. ICM: ❑ ❑ TN,TM. Na cNatE6wf N[OWEO Mt,TENANT 1 LASIMUCETNE NV.TONE OWIm.SLISOWN auTcww. _II =II= ,Si--..� a rwwMAN NucN.ww.wLOOMMCoNOE.wn _0_ =0= in MI I I IWS I CJS 5 GAS—GAS—GAS—GAS yG GAS—GAS—GAS—GAS—GAS—GAS—GAS—GAS—GAS—GAS—W7-rf ,= DAM Na "cv6lars I, r L-f �� Z ti. II— I ' . _.] SPECC HVAC NOTES00. L III II1IurIuulT i •`AT—w `AT—GAs-` General Security Services Corp. o M,vaL 1 — r_I FLB54556 Lrr 1 "�'� Location: f_I 1I o Ir_� I =o. =0= 1 Riser Room FACP: SK5104 a �1 ■■ ■I � ,.T ,T r t e– — ° '�• Electrical: IJ' / L North West House Panel 1. o }�,, i —'��.,,.: __ �–_-_ •f/' 9 j�CDdrl l s�j^�J e Branch Circuit#21. r o o ('e 1 r. r_ r_. -- Imo. :� I �"o Vic♦ , i r l , . � ��=� a I.M.AM. MANUNI 1 , ZONES: ,_ u Z _ ffm J) ie z ani i. �► �v> id �J/C�c�Q, rQ�ILN� 1 WATERFLOW 3 fro F_-�ti • �ii � '7.$� k■ � ■���■ � ■ ��,---CP � �^ 2 GATEVALVES a � • II " GI I y l vr� F, c 3 FACP SMOKE DETECTOR "o ME MEW= ��:.,_ _ _ �,. ` - ._ _ 4 FACP PULL STATION o o 5 RTU 1 &2 E° 6 RTU3 &4 .Ke.nek I 726286