HomeMy WebLinkAboutabove ground piping info A Pae 1 of 3 Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners,and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship,or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME JEM TECHNICAL DATE -Lc{ PROPERTY ADDRESS 450 OLD CRYSTAL BAY RD ACCEPTED BY APPROVING AUTHORITIES(NAMES) CITY OF ORONO ADDRESS PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS ®YES ❑ NO EQUIPMENT USED IS APPROVED ®YES ❑ NO IF NO,EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN ®YES ❑ NO INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES? ®YES ❑ NO 1. SYSTEM COMPONENTS INSTRUCTIONS ®YES ❑ NO 2. CARE AND MAINTENANCE INSTRUCTIONS ®YES ❑ NO 3. NFPA 25 ®YES ❑ NO LOCATION SUPPLIES BUILDINGS: OF SYSTEM YEAR OF ORIFICE UANTITY TEMPERATURE MAKE MODEL MANUFACTURE SIZE QRATING TYCO EC-25 2015 V. 225 214 SPRINKLERS TYCO FRB 2015 3/4 4 286 TYCO FRB 2015 1/2 35 155 PIPE AND TYPE OF PIPE: STEEL SCH 07-GROOVED XL-THREADED FITTINGS TYPE OF FITTINGS: VICTUALIC MAXIMUM TIME TO OPERATE ALARM VALVE ALARM DEVICE THROUGH TEST CONNECTION OR FLOW TYPEMAKE MODEL MIN SEC INDICATOR VANE POTTER VFR DRY VALVE Q.O. D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE TIME TO TRIP TIME WATER ALARM OPERATING THROUGH TEST WATER AIR TRIP POINT REACHED TEST OPERATED TEST CONNECTION' PRESSURE PRESSURE AIR PRESSURE OUTLET' PROPERLY without Q.O.D. with Q.O.D. N/A IF NO,EXPLAIN: 'MEASURED FROM TIME INSPECTOR'S TEST CONNECTION IS OPENED. 1996 Edition OPERATIONPae 2 of 3 ❑ PNEUMATIC [:1 ELECTRIC El HYDRAULIC PIPING SUPERVISED ❑ YES ❑ NO DETECTING MEDIA ❑ YES ❑ NO SUPERVISED DOES VALVE OPERATE FROM THE MANUAL TRIP, REMOTE,OR BOTH CONTROL STATIONS? ❑ YES ❑ NO DELUGE AND IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUI;FOR= PRERATIONTESTING?VALVES ❑ YES ❑ NO DOES EACH CIRCUIT OPERATEDOES EACH CIRCUIT MAXIMUM TIME TO MAKE MODEL SUPERVISON LOSS ALARM? OPERATE VALVE RELEASE? OPERATE RELEASE N/A YES NO YES NO MIN SEC PRESSURE LOCATION MAKE SETTING RESIDUAL PRESSURE FLOW RATE &FLOOR &MODEL STATIC PRESSURE REDUCING (FLOWING) VALVE TEST INLET OUTLET INLET OUTLET FLOW RATE PSI PSI PSI PSI N/A HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi(13.6 bars)for 2 hours or 50 psi(3.4 bars) above static pressure in excess if 150 psi(10.2 bars)for 2 hours. Differential dry-pipe valve clappers shall be left TEST open during the test to prevent damage. All aboveground piping leakage shall be stopped. DESCRIPTION PNEUMATIC: Establish 40 psi(2.7 bars)air pressure and measure drop,which shall not exceed 1'/ psi(0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop,which shall not exceed 1 Yz psi(0.1 bars)in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT: 200 PSI ( BARS ) FOR 2 HOURS IF NO,STATE REASON: DRY PIPING PNEUMATICALLY TESTED ❑ YES ® NO WET SYSTEM EQUIPMENT OPERATES PROPERLY ® YES ❑ NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE,BRINE,OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? ®YES ❑ NO TESTS READING OF GAUGE LOCATED NEAR RESIDUAL PRESSURE WITH VALVE IN TEST DRAIN WATER SUPPLY TEST CONNECTION: CONNECTION OPEN WIDE: TEST PSI ( BARS ) PSI ( BARS ) UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING VERIFIED BY COPY OF THE U FORM NO.858 ❑ YES ❑ NO OTHER, EXPLAIN: FLUSHED BY INSTALLER OF UNDERGROUND ® YES ❑ NO SPRINKLER PIPING BLANK NUMBER USED LOCATIONS NUMBER REMOVED TESTING GASKETS WELDED PIPING ® YES ❑ NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING ® El COMPLY WITH THE REQUIREMENTS OF AT LEAST YES NO AWS D10.9,LEVEL AR-3? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS ® ❑ QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST YES NO AWS D10.9,LEVEL AR-3? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO ® El THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE YES NO SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO Y YES E](DISCS) ENSURE THAT ALL CUTOUTS(DISCS)ARE RETRIEVED? NO 1996 Edition Page 3 of 3 HYDRAULIC NAMEPLATE PROVIDED IF NO, EXPLAIN: DATA NAMEPLATE ® YES ❑ NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS NAME OF SPRINKLER CONTRACTOR: ESCAPE FIRE PROTECTION TESTS WITNESSED BY SIGNATURES OPERT OW D) TITLE DATE SPRINKLER CONTRACTOR(SIGNED) TITLE DATE ADDITIONAL EXPLANATION AND NOTES: 1996 Edition