My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
above ground piping info
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0450 Old Crystal Bay Road North - 33-118-23-13-0020
>
Misc
>
above ground piping info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:44 PM
Creation date
3/8/2018 1:25:04 PM
Metadata
Fields
Template:
x Address Old
House Number
450
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
450 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823130020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A Pae 1 of 3 <br /> Contractor's Material and Test Certificate for Aboveground Piping <br /> PROCEDURE <br /> Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by an owner's <br /> representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. <br /> A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners,and <br /> contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, <br /> poor workmanship,or failure to comply with approving authority's requirements or local ordinances. <br /> PROPERTY NAME JEM TECHNICAL DATE -Lc{ <br /> PROPERTY ADDRESS 450 OLD CRYSTAL BAY RD <br /> ACCEPTED BY APPROVING AUTHORITIES(NAMES) CITY OF ORONO <br /> ADDRESS <br /> PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS ®YES ❑ NO <br /> EQUIPMENT USED IS APPROVED ®YES ❑ NO <br /> IF NO,EXPLAIN <br /> DEVIATIONS: <br /> HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN ®YES ❑ NO <br /> INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND <br /> CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? <br /> IF NO, <br /> EXPLAIN: <br /> INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES? ®YES ❑ NO <br /> 1. SYSTEM COMPONENTS INSTRUCTIONS ®YES ❑ NO <br /> 2. CARE AND MAINTENANCE INSTRUCTIONS ®YES ❑ NO <br /> 3. NFPA 25 ®YES ❑ NO <br /> LOCATION SUPPLIES BUILDINGS: <br /> OF SYSTEM <br /> YEAR OF ORIFICE UANTITY TEMPERATURE <br /> MAKE MODEL MANUFACTURE SIZE QRATING <br /> TYCO EC-25 2015 V. 225 214 <br /> SPRINKLERS TYCO FRB 2015 3/4 4 286 <br /> TYCO FRB 2015 1/2 35 155 <br /> PIPE AND TYPE OF PIPE: STEEL SCH 07-GROOVED XL-THREADED <br /> FITTINGS TYPE OF FITTINGS: VICTUALIC <br /> MAXIMUM TIME TO OPERATE <br /> ALARM VALVE ALARM DEVICE THROUGH TEST CONNECTION <br /> OR FLOW TYPEMAKE MODEL MIN SEC <br /> INDICATOR <br /> VANE POTTER VFR <br /> DRY VALVE Q.O. D. <br /> MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. <br /> DRY PIPE TIME TO TRIP TIME WATER ALARM <br /> OPERATING THROUGH TEST WATER AIR TRIP POINT REACHED TEST OPERATED <br /> TEST CONNECTION' PRESSURE PRESSURE AIR PRESSURE OUTLET' PROPERLY <br /> without <br /> Q.O.D. <br /> with <br /> Q.O.D. <br /> N/A IF NO,EXPLAIN: <br /> 'MEASURED FROM TIME INSPECTOR'S TEST CONNECTION IS OPENED. <br /> 1996 Edition <br />
The URL can be used to link to this page
Your browser does not support the video tag.