Loading...
HomeMy WebLinkAboutseptic info 11:64 AM Elmer J. Peterson Co. 11/14/07 Customer History November 14, 2007 Customer Gallons Start Date Job Description Doboszenski and Sons:11/8/06-425 Old Crystal Bay Rd.j, 2000 11/812008 Pumped 2 tanks thru manholes,40'hose,smashing tanks,demo house Pane 1 SEPTIC SYSTEM INVENTOR Y Address: 425 Old Crystal Bay Rd. N. PID: 33-118-23 24 0003 Building Typeresidence BRs Install'd for: 3 In Musa: Yes Permit#: 5255 Date of Permit: 7/24/78 Installer: Jerry Johnson System Type: standard trench Performance: no Tank Filter: SYSTEM CONDITION Conformity: 3 Tank Condition: 5 DF condition: 8 Failure Pot: medium SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Setback to Bldg: 12 Cesspool: unknown DRAINFIELD Length of Lines: 200 # Lines: 2 Trench Width: 3 Treatment Area: 600 Type of Filter: rock Soil Boring: yes Tile Size: 4 Under Tile: 12 Perc Rate: Setback DF-Bldg: 30 DF Ht above Wt: 0 Soil Type: loam, clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File yes Pump Type: subm. Depth: 159 Diameter: 4 Method: drilled INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 7/25/78 new tanks (600, 600 gal.) c 6/29/78 300 8/6/81 no surfacing 1 10/1/86 2000 8/18/86 no surfacing 1 11/1/91 2000 8/8/88 no surfacing 1 12/18/98 2000 10/9/91 no surfacing 1 110;21- 0y aoec 5/5/93 no surfacing 1 8/8/97 non-compliant-repair by 12/31/2007 3 10/25/99 non-compliant, repair by 12/31/2007 3 8/22/01 non-compliant,replace by 12/31/2010 3 9/5/03 non-compliant,replace by 12/31/2010 non-compliant ' `- O` i*' I% y�odC�e6l �yPd, !l, , g l; m4 G/o 3q6 Aga 40'b 6�0 � 01 Municipal Offices CF�P Y of ORONO Y y Stmt Dress: ._ Mailing Address: 2750 Kelley Parkway P.O. Box 66 Orono, MN 553b6 Cgstal Bay, MN 55323- 66 To Curfailit fir: Addres�: �a S old (1-1s-ml R cA,, . Rd- Al, City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been ins and appears to fall into the categories checked below. SYSTEM'CONFORMITY 0-3): 1 "CODE SYSTEM"An ISTS which meets all the location,design and co ction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locatii design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot req ' ment for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located:istribution in a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of theOrono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the device and the limiting soil characteristics. TANK CONDITION(5-7): 6 Tank inspection indicates: 5 Pumpout not needed at this time. 66 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years; v Tank was last pumped 1 a.-1t1 A ). Make sure septic tanks are pumped through manhole and not thrq h white inspection pipes This allows for the prover cleaning. Keep water softner and iron filter discharge out of septic svkem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION($-10): Q ® Drainfield is dry,no surfacing evident 9 Some evidence of surfacing,not critical yet 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: 0\ 01> Date of Inspection Bolteiman- Septic System Inspector Note:In the event thatthisinspection report is used to satisfy the requirements for a mortgage o other transfer of property,be advised that this report does nc or certfy�ma syr will continue to function properly,but is merely an opinion of a adequacy ofthe system undercurrent conditions t am die avails Telephone(952)2494600 - Faz 952)249-4616 www."ronomn u o Oma;, O CI Yof ORONOP r ti 12 � Municipal Offices Street Address: '� �i�• g� :ed Mailing Address: . •2150 KP.O. Bax 66 Orono, Crystal Bay, MN 55323-0066 Owner: '� F 5 Nf o n, P-c : '�i u Sr Address: yds City Ordinance 199 requires that each existing on-site sewage tream in Orono be inspected every two years. The on-site sewage treatment system at the above address has beeand appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM° An MTS which meets 4 the location,design and constructon standards ofthe current Oroiio Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,4esisa and construction standards of the eurre t Orono Municipal 3QCode but does meet the three fact separation requirement'and which is not or an h—hent threat to public health or saC.:ty. 'NON-COMPLIANT SYSTEM" Apcohffiited ISTS;as ISTS located a designated 100 year flood plain,any isTS which may or may not meet all the location,design,or construction standards of the current o Municipal Code and which is far any ISTS with less than three feet of unsaturated soil or sand between the dista'b tion device and the limiting failing 'reason;and tutg;orT characteristics TANK CONDITION(5-10): Tank inspection indicates: 5 Puinpout not needed at this time. © Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pump:eliminate out as soon as possible. 8 S)stare is discharging to the surface. Tanks must be pumped out within 48 hours l surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection rises(4"dib pipe)must be installed in each tank at nest pumpout if tanks have not been pumped out within the last three years,they should be pumped out now. 10 Inspection pipe is located directly over tank baffle(does not give accuratemeasureteat of solids accumulation). If tanks have not been pumped out within the list three years,they should be pumped out now. DRAINFMLD CONDITION 11-14 : \\ 11 -Drsinfield is dry,no surfacing evident. 12 Some evidence of surfacing,not cdticsl yet 13plteld is saturated within,90 days.ted and visibly d�schar eomamplglag untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be 14 Drainfield estent and condition unknown. COMMENTS: S 51- S1; av to Iac'lC OF 3 �oofi Sc craN:o-\ a < C 4 okto a�- 13�- �t'c.Cl.es lgct b )a.-3�,a-DID Date of Inspection septic System ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or er transfer of property,be advised that this report does not guarantee or catl15,that an esistirtg system will continue to fitaetion properly,but is merely an opinion of r adequary information of the system Hader cum conditions based an the available . yam 0 CITY OF ORONO O O Municipal Offices Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT r� INSPECTION REPORT �9kEsuo Owner: �j Address: Z 01—/) Permit #'s: Z Dates: /off% C ntractora: City ordinance number 100 requires that each on-site sewage trea ment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has n inspected and appears to fall into the category checked below. (This iSX an existing system l I new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, desi n, and construction standards of the current City Codes, and which is operating satisfactorily by treati g and disposing of the entire current sewage input without discharging any pollutants into ground or surf ce waters. 2 "CONFORMING SYSTEM"-A system which does not meet all th location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing f the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system ocated within a designated 100-year floodplain; any system which may or may not meet all the location, d sign, and construction standards of the current City Codes and which is failing for any reason; and any sy tem with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil haracteristics. (The limiting soil characteristichas or l I has n t been identified at this time. If the limiting soil characteristic has not been ids fied, this classific tion may be subject to revision.) TANK CONDITION (5-10): pection indicates: 5 umpout not needed at this time. Solids accumulation in tanks indicates they should be pumpedut this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks s ould be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped o t within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Ins ction risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped o t within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does n t give accurate measurement of solids accumulation). If tanks have not been Pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): f to inspection indicates: 11 ainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated a fluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): _--+ POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): 14 CPMMENTS 2 J ° , ']� 2CW, Date of Inspecti n is System Inspector Note: In the event that this inspection report is used to satisfyTherequirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certiat an existing system will continue to function properlyi but is merely an optnton of the adequacy of the sysder current conditions based on the available information. This report must be kept on the premises with them location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner Y- O CITY OF ORONO O O Municipal Offices Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT INSPECTION REPORT � Gtiti. k VS LO Owner: Ton) Address: 01C_Y)g�/ 0 Iv, -Tp iryv_abdLon Permit #'s: Dates: 2:2Y ntractors: City ordinance number 100 requires that each on-site sewage tree ment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has n inspected and appears to fall into the category checked below. (This is [.A an existing system [ ] new construction) SYSTEM CONFORMITY 1-3 1 "CODE SYSTEM"-A system which meets all the location, desi n, and construction standards of the current City Codes, and which is operating satisfactorily by treati g and disposing of the entire current sewage input without discharging any pollutants into ground or surf ce waters. 2 "CONFORMING SYSTEM"-A system which does not meet all th Location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing f the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system Located within a designated 100-year floodplain; any system which may or may not meet all the location, d ign, and construction standards of the current City Codes and which is failing for any reason; and any Sy tem with less than 3 feet of unsaturated soil or sand between the distribution device and the Limiting soil haracteristics. (The limiting soil characteristic ( ) has orhas n t been identified at this time. If the Limiting soil characteristic has not been identified, this c s sific tion may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped t this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks s ould be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped o t within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Ins ction risers (4" dia. pipe) must be installed to each tank at next pumpout. If tanks have not been pumped t within the last three years, they should be pumped out now. Inspection pipe is Located directly over tank baffle (does n t give accurate measurement of solids accumulation). If tanks have not been pumped out within the Last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D12 nfield inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated a fluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): COMMENTS: Date of Inspection S-peic System Inspector Note: Inthe event that this inspection report is used to satisfy he requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certif that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the �ystem location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the Nortb Sbore of Lake Minnetonka ON-SITE SEWAGE TREATMENTCIT INSPECTION REPORT OF POST OFFICE BOX 66 _ONO 1335 S. Brown Rd. Crystal Bay,MN 55323 473-7357 m OWNER 0, o L (�'�'� `'►")r�r� A DRESS 7�5 I a 4114Imo" PERMIT NO.'S. DATES CONTRACTORS T-4 City Ordinance No.210 requires that each onsite sewage treatment iystern in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is 9 an existing system ❑ new construction) 1 Meets or exceeds current City standards in all respects rel ting to design,construction,and location.Appears to be operating properly. 2 Does not meet all current City standards for new constr ction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with pre ious codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects re ating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. rl4 System may or may not meet current City standards for esign,construction or location,but is failing to properly treat and dispose of the current input,and is endangering a water s pply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public uisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is ne ry,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump• have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Dram laid inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the lest three years,they should be pumped out now. Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil tvp4 s,water Future Expansion ❑ Soil table,and system co dition) As 11 High water table Low air ❑ Lot size Medium Poor ❑ Lake,wetland,or stream High ❑ Inadequate ❑ Drainage ❑System is caus ng visible surf ce discha ge. COMMENTS: 0 l %ate ® r D Date of Inspection fSeptic System Inspector Note: In the event that this inspection report is used to satisfy the require ants for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will contin a to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with stem location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner