HomeMy WebLinkAboutseptic info CITY®f ORONO
Municipal Offices
Street Address: Mailing Address:
2110 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
TO Current Owner: Address:- 315 00 cf �,"l OJT - IV
City Ordinance 199 requires that each existing on-site sewa a treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address hs been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY_(1-3): 1.
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not met all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement o�two foot requirement for systems installed 1996 or earlier,and which is not failing or
30"N
imminent threat to public health or safety.
"NON-COMPLIANT SYSTEM" A prohibited ISTS;�ISTS located within a designated 100-year good plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sar{d between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7):
Tank inspection indicates:
`J Pumpout not needed at this timex
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic sstem.
7 Inspection risers missing-tanks could not be inspeed. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last thr a years,they should be pumped out now.
DRAINFIELD CONDITION(8-10):
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untr ated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 9 days.
COMMENTS: tj c 0 e.a \-��r �� �..11�— �� �� 1F,L
y„r v—.J�L,. 1 PUS'S• 'Z�f.5 �
Date of Inspection Matt Bolterman - Septic System Inspector
Note:In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system undercurrent conditions based on the available
information.
Telephone(952)2 9-4600 • Fax(952)249-4616
O.- O
ITY of ORONO
Municipal Offices
t;ii;ug� Street Add' ss: Mailing Address:
E880 2150 Ke ley Parkway P.O. Box 66
Orono, N 55356 Crystal Bay, MN 55323-0066
Owner. 0.c� �'n e c,�• Address:_3 I s d Cr Is-t�l Qg
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been;inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3):—�-
1 "CODE SYSTEM" An IsTS which meets all the location,design and!construction standards of the current Orono brunichW Cod,-
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement,and which is n ot failing or an imminent threat to public health or sa:cty.
"NON-COMPLIANTSYSTEM" AprohibItedISTS,aaISTS located within designated 100 yearflaodplaia,anyISTs whichmay
or may not meet all the location,design,or construction standards of the current Omno brunieipal Code and which is far7iag for any reason;and
any ISTS with less than three feet of unsaattuated soil or sand between thle distribution device and the limiting Bail characteristics.
TANK CONDITION(5-10): . ' .
Tank inspection indicates:
5 Puiapout not needed at this time. /
UTank must be pumped out this year (city code requires tanks to be Pumpt,I out every 3 years. Tank was last pumped
7 Solids accumulation in tanks is at a critical a critical level. Tanks should It pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 4 3 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected Inspection risers(4*dia.pipe)must be installed in each tank at nest pumpout if tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate)measurement of solids accumulation). If tanks have not been pumped
out within the Litt three years,they should be pumped out now.
DRATNFIELD CONDITION 11-14 . 1
11 Dminfi ld is dry,no surfacing evident
1 Some evidence of surfacing,not critical ygL
13 Dmiafield is stunted and visibly discharging untreated effluent to the su Contact the Ci ectar immediately.R
eompteted within 90 days, t3`� y epairs must be
14 Drainfield extent and condition unknoKa
CONSENTS: 5 S Lz S rho n- Co ve -ro 1 ot ch, 3 �—oo-r
be.N pro d SQ-aS o nA\ V--qr,")roM6 ,
qC,d 6a o a c�cl cis
Date of laspecdon
Septic system Inspector
Note: ra the event that this inspection report is used to satisfy the requirements fora rtgage or other transfer of property,be advised diad this report does nat guarantee
or certify that an eeisting system will continue to function properly,but is merely an inion of the adequacy of the system under eunvA conditions based as the available
B&Gmtstion.
CITY OF ORONO
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
ti
l9kE H0
Owner: 10 1Y11t�j Address: 315- 6L0 C..r,1AiLd&y 9 r /Y l 5530
Permit #'s: 6916,6 Dates: 12-6-71 Contractors: hVlV �p"D$,
City ordinance number 100 requires that each on-site sewag treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above addres has been inspected and appears to fall into the category
checked below.
(This is10<an existing system I ) new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM'I-A system which meets all the locationdesign, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and dis sing of the entire current sewage input without discharging
My pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a s stem located within a designated 100-year floodplain; any
system which may or may not meet all the localion, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the timitini soil characteristics.
(The limiting soil characteristic has or [ has not been identified at this time. If the limiting soil
characteristic has not been Iden ifi , this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be weed out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
System is discharging to the surface. Tanks must be Fumped out within 48 hours to eliminate surface discharge.
Inspection risers missing-tanks could not be inspect . Inspection risers (4" dia. pipe) must be installed to each
tank at next pumpout. If tanks have not been rumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the Last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
D field inspection indicates:
0T
Drainfield is dry, no surfacing evident.
TSome evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (s Lope,setbacks.etc.): flO�
POTENTIAL FOR SYSTEM FAILURE (depends on soils water table tc. :
COMMENTS: 8 � a)1t k6 i'wx. ✓'� Y�'h`Q�
r r e 5
Date of Insp ction Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee r certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of he system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITYof ORONO
�,'� Municipal Offices
�y Street "dress: Mailing Address:
2750 alley Parkway P.O. Box 66
y� Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: ! Address: 315 Old Crystal Bay Rd. N.
Permit Vs: 2966 Dates: 12/6/71 Contrac ors: Widmer Bros.
(This is [X an existing system [ I new con truction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds currentCi y standards in all respects relating to design,
construction, and location. Appears to b operating properly.
2 Compliant System: Does not meet all cur ent City standards for new construction, but in
most respects appears to be designed, loc ted, and constructed in accordance with previous
codes and is functioning properly.
3O Non-Compliant System: System may or ma not meet current City standards for design,
construction, or location, but is failin to properly treat and dispose of the current
input; and any system with less than thre feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level 04 4 has or [ ] s not been identified at this time. If the
saturated soil level has not been identified, t s classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks -indicates the should be pumped out this year.
7 System is discharging to the surface. Ta s must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not a inspected. If tanks have not been pumped out
within three years, they should be pumped ut and risers installed now.
Inspection pipe is located over tank baffl -can not measure solids accumulation. If tanks
have not been pumped out within three year , they should be pumped o���u//t now.
(During the last septic tank Maintenance Pumpou the tanks ( ] were or L!�] were not confirmed
to be watertight by the licensed pumping cont actor. If the tanks were not confirmed to be
watertight, this classification is subject to r vision.)
INFIELD CONDITION (11-14) : li
(ly Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical y t. Repair is not required at this time.
13 Drainfield is saturated and visibly di charging untreated effluent to the surface.
Contact the City Inspector immediately. R pair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the
septic system is required by 12/31/2007.
Date of Inspection S96iic System Inspector
Note: In the event that this inspection rep rt is used to satisfy the requirements for a
transfer of property, this report does not gua antee that an existing system will continue to
function properly, but indicates the operation o the system under current conditions.
Telephone (612) 47343$7 9 FAX 473-0510
� 0
CITY OF ORONO O O
Municipal Offices
Post Office Box 66
Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT
VA INSPECTION REPORT
ti
Owner: t',�"� Q� Address:
Permit #'s: Dates: 1R4-
-7 Contractors: �ci✓ t� � �®
City ordinance number 100 requires that each on-site sewage reatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address h s been inspected and appears to fall into the category
checked below.
(This is Dt an existing system E ) new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by tr ating and disposing of the entire current sewage input
without discharging any pollutants into ground or urface waters.
"CONFORMING SYSTEM---A system which does not meet al the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the locatio , design, and construction standards of the current City
Codes and which is failing for any reason; and an system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting s it characteristics.
(The limiting soil characteristic E ) has or his not been identified at this time. If the limiting soil
characteristic has not been identified, this c ass fication may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
4Pumpout not needed at this time.
), Solids accumulation in tanks indicates they should be Oed out this year to help prevent future problems.
Solids accumulation in tanks is at a critical level. a s should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last t ree years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 d ys.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (sloae.setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils water table etc. :
COMMENTS:
Date of Inspection gief3tfic System Inbpector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or c rtify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the ystem under current conditions based on the available
information.
This report must be kept on the premises with he system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT POST OFFICE BOX 66
OF� 1335 S. Brown Rd.
NO Crystal Bay,MN 55323
473-7357
OWNER ( � , ADDRESS �� OCOd
PERMIT NO.'S. DATES ��� CONTRACTORS )/ , �
City Ordinance No.210 requires that each on-site sewage trea Brit system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is 'I� an existing system ❑ new constructio )
r1 Meets or exceeds current City standards in all rasps relating to design,construction,and location.Appears to be operating
properly,
y 2 Does not mast all current City standards for new nstruction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance wi h previous codes.System appears to be functioning properly;no major
upgrading of the system is required at this time.
Does not meet current City standards in many resp relating to design,construction,or location.Appears to be operating
3 adequately at this time,but has a relatively high pot ntial for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is i ecessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must o tain a permit before work is started.
SYSTEM CONDITION.(m Checked items may require your action)
Tank inspection indicates: 36 Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump• have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks TDral field inspection Indicates:
should be pumped out as soon as possible. Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. I ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers IV dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. I ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for Sys m Failure Site Capabilities for
❑ Slope (depends on soil pas,water Future Expansion
❑ Soil table,and syste condition) Adequate
❑ High water table Low Fair
❑ Lot size Medium ❑Poor
❑ Lake,wetland,or stream ❑High ❑ Inadequate
❑ Drainage ❑System is using visible
surface di urge.
COMMENTS:
//L
AelfNt
Date of Inspection I Septic System Inspector
Note: In the event that this inspection report is used to satisfy theregw ements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will con inue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises wit system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner