Loading...
HomeMy WebLinkAbout2014-01448 - pool CITY OF ORONO * 2014 - 01449 * 2750 KELLEY PARKWAY DATE ISSUED: 03/02/2015 ORONO,MN 55356- 952 249-4600 FAX: 952 249-4616 ADDRESS 2490 OLD BEACH RD PIN : 21-117-23-22-0005 LEGAL DESC SHORE HILLS : LOT 004 BLOCK 000 PERMIT TYPE ACCESSORY STRUCTURE PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : POOL-IN GROUND ACTIVITY : 329-STRUCTURES OTHER THAN BUILDINGS VALUATION : $ 34,000.00 APPLICANT PERMIT FEE SCHEDULE 509.75 PLAN REVIEW 331.34 KALIFORNIA POOL AND SPA STATE SURCHARGE(VALUATION) 17.00 9132 ANNAPOLIS LANE N P.O.BOX 1469 TOTAL 858.09 MAPLE GROVE,MN 55369- Payment(s) CHECK 3398 858.09 OWNER MCINTEE,SHAWN&JACQUELINE 2490 OLD BEACH RD WAYZATA,MN 55391- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 1 days at any time after work has commenced. The applicant is re onsi a or assuring all required inspections are requested in co th the State Building Code.This permit may be revoked at ti e f d e cause. s Weaht itee Signature Date Issued y Signature Date City of Orono CC" Building Permit Application for New Structures or Additions Mailing Address: Permit number: C go/7 — 6 l j PO Box 66 No Crystal Bay, MN 55323-0066 Date received: 1 Street Address:' Received by: 7 i a 2750 Kelley Parkway Plan review fee: Orono, MN 55356 �FsiiE Main: 952-259.4600 Total Fee: Fax: 952-249-4616 www.ci.orono.mn.0 This application form must be completed in full and all required information must be submittecV,, �j F 01? Incompiete applications will be retumed. (Please print) c� b GENERAL INFORMATION: /� Job Site Address: C7`I°1 O Ol� iG0 Will this be a Parade of Homes, Remodelers Showcase Home or other Display Home? Yes El No if yes, a special event permit is required with Police Department and City Council approval 60 days prior to the event. Shuttle bus service will be required unless applicant demonstrates sufficient on-site parking is available. Non-permitted events will not be allowed. CONTRACTOR/APPLICANT INFORMATION: Name: Al,'c.Y_ �t2r�t Pfd �7 0��, f Ili 71 } State License# A-. Expiration Date: Phone: cell s r775' R01551 (office '7 b 3 Mailing Address: Po Ro v r.al Cit a,Jjk GLrrek ZIP: SS3) Contact Person: r Applicant is: C / Homeowner (circieone) Email and/or Fax: ,'04 foCo PROPERTY OWNER INFORMATION: Name: Phone(day): (01J — 00?— T Address: aY90 Ob 4tael lZvil City: 0(0,10 ZIP: $! ✓�j/ Email and/or Fax ARCHITECT/ENGINEER INFORMATION: Name: Phone(day): Address: City: ZIP: Email and/or Fax: PROJECT INFORMATION: Description of project: _ 1.Type of Project 2.Proposed Use 3.Structure Type 4.Sewage Disposal& Water Supply New Construction ❑Single Family with ❑Residence Addition attached garage ❑Garage/Accessory Bldg. ❑ Public Sewer ❑Accessory Building ❑ Single Family with ❑ Deck ❑ Relocationdetached garage ElOffice/Commercial ElPrivate Sewer Other:(specify) OOCL ❑ Multiple Family/Condo ❑Warehouse ❑ Public ❑Storage ❑ Public Water —Any earth movement may require ❑Commercial Other(specify) MCWD review&permits. ❑ Industrial ❑ Private Well Minnehaha Creek Watershed District(MCWD) ❑Other: (specify) Q[J 18202 Minnetonka Blvd Deephaven,MN 55391 Phone: 952-471-0590 Fax: 952-471-0682 _=,rninnehahggreek.2M Estimated Construction Valuation (excluding land) $ �3 L O�4 Packet Last Updated: 04/1912013 Page 22 of 23 I PLAN REVIEW CW.ECKLIST F®R NEVV STRUCT'IU.RES l ADDITIONS AddreseMermit Number: Description of work: Septic review by Date Approaisd: Zoning review by. Date Ap�lrovetl: Building ireview-by: -Date Approved Gtding review by: Date Approv�ti; Zoning District: Zoning File#: : Reso# Reso Date:_ Zoni :Lot Area; SPI AC = Width---^-�--, " Lot Coverage SF % Survey bmitted M Yes O No Data of Survey: Revised date. Pro ed baclfs: " Front(Lake) Rear.{Street) ( N S, W ) N Other Bui�dings We band Side ,i•� °i Defined Heigh#: Pea 's -(► et= , IFacis#irg C190tour), Vj Perimeter (linear feet) k? Q YDS: AOR A BtJILDiNG tftf1TH A BASEMENT OR C :The distance J C7 - FOL�iDATION START WITH Proposed floor(of\ _ space)and the higl, The distance between the top ofslab end If Yow lca�e a:. v the,hiliodntof ft too. If you have a... �,�- • GABLE OR M • GABLE O[�HIPPED ROOF((nq windows) So windows): $401reot half the C& distance.be between the highest poird of the roof: of the roof to the to the Iqw pint o�the(orresportding SWBTRACfiION corresptlnding g g8bte or hipped roof ' ($ABED Obi ROOF . GABLE OR,HIPR_ - CrASLE ORHjPPED ROOF( �l T hwindowe), Subtra ® windows btract haif the distance; distance"t*tween between a of the highest bast window and p window and the highest paint of the point of the roof - roof • All OTHERROOF T1lPES(tlaS • ALL OTHER ROOF mansard;etc:No subtle mansard"etc):No su ADDITION Add the distance k�etweetl.flee tqp of slab SUBTRACTION Subtra(t the distends be h,_ (BASED OH: and the.ktighest.existing grails adjacent to (BASED pN EXISTING rrierrt/crawl s air and the BUSTING the foundatlon GRADES), pighest existing-g edecent to 0 GRADES', toundadon OR 1 (whichever is,l�s)• UALS r>Bftned building heigl>t t4i7A15 Qe3iruid but1 g height Shoreland Di:$trict MC1MD Permit.Receh►bri` 'Ave a Lakeshore<Set k Met? Bluff _1Q Yes © No D NIA 0 Yes C,3 Nd ® Yes D Yes,- G No Q N P.errrtit urt_ft' - Setback: %tormwatar uaiity imxilsting Proposed Overiaa Di riot Tier HaMcover Haricovex :10ariance Requiretl CUP Re fired , `Y�s ® `Nti o Yes< i� No Tye{'s) Type(s): Updated' January 201.3 i uAformstplen review cheddiet 2013.doca� r c t r #' t x x i 4 t y;- n. ,5�z �,�{ ,,s'G- 1'3 -Y t3 z.,�Ax '3Aii I. r k.4 4 Tr"! ;e,- r ti• v ws a 15 1:1re 1. ` - Y :t^r' s;-� -tea S t '� - t- d L '�'( .: 7 ✓t+iY N .0 s p $ 'Su -F y .^�t l .' y>:a ,, L h^1 _. ; $.�,1 xa Jr k> k t-.. P. #S,x ark}` '' r ri7 q h 5' x $,..i e �' S r ` e *f a t r 3f �r 3 P ,t # tai. srv" "h ,, '`' Tt� � Yrar -at Tyr„ i� �. s -' aa"R.',.xsYi r s >$4'"�''�r�r xrt t?k a J X �" ry Jt € k. f 1. ,dt f m '# ? NSA+. ATr"��i r �yr:r �,i�, ,� '-�' t` k .ud r 'xa '��r'4 x«, Ut a?`�q , c v',.m -y .r T s 1 -. v' w lx x'i"J ij .11, fl �� d - '+`Kb`-3. Y .�N afA i S.•i jlwlf52f a r i.c'q ��aiI'll I x- .. '' a;baa de t r r r �,e s r�' _ r x` ) x.�. r w '+s r7 i z, .� r. w c c r e `t"SF, r� vi r n s -t:a yrve k _ - Y {,�'y x' d sti�� f 4y tieu - sr r rK ~' * 4 ``,^l rr.- r i. w�%rt5� ,, r m```�c !°kk ;:i `, r 1,c $ + d n F rIF, ya .v 'x- "S< ,.a+` "` r yeti n x�}`.. .,�, . ><• a rk H 'tdr t` »E W r 5 e}` -a y >h f '+Y' ✓ 5 Ott R,le, - S' t vj}�k d v R t� i q; -0 J.a� s e € - 3 e x 4 " d � � YAR r s t 2,, _fa -t wcS'k" r' . C l ) 4 ,k4 �:"� Y�Is.��+,;,,�� We r -rr. 5 S' 1 ai 1{L illa�f S 7r o-+ ."� - �f s �o's`�d� � i' tia4 _r a n _ .r p `. d "# .' 4 '�j$A ti a k 9frs� ,rn r r �x ✓t r,.~ ,J31 r t S YaK t I-: 1 .M4'� >:2•Lt £v � 5+a.-, «s% �; r } +V a qr t: a P't s,r?" z . k r"',t_ ,� `'s "s SFr r '�'� S }'k't 1=.€,,x" °a x5a""+5� r.t''` 5 ' k i a ���`a 4 vs �crrn r ,�"x t Y s' r .X t �,* !f: yy zr r r ,,t t �..a q 3 s4 9 �. - 't e s _ : '# w t :r€ 1 t '�+t qE r ,, iu [ .� Y - r r ° Ci X±`�P r' r b µ S _ "ten a r,s { _� A. F n F d ,�I 11 .}�11-1 P, - a- i re 2 3�< n d �- �`k ` 3 i + } _u r xy < 4 t -�' e r F ,,"„ �j @ r €+�$t.•�'M �. r .} x -;�I ' , r•m.. t�r r �moi, r�:- u : O7 "� dsr i,� Pd4 � � IA1rii, t 1 x3'" r .� t.x i" i Yid R t '' sL, r - - 't r , b Y'3- a $, £.,.,Y y;.e �'�n, E,S•'►"�iER7rt- A`� r >< 5 Y4 r rL,q„pb '� P,r, : �P 4 f i f ; {Yrntd E� N #X: E W q ,4 xX $ ¢_ 1, `,' -4r ypi AT;y+ x'i rs '' h a v ;y4a,' 3 s a � " t ^ r ills x? ; E_'r ,t,moi.'� q m'r r r F r f r� - a - - ' ' �. u _ _ t ^.,s 2� k x k .t ++s ,a. r'9'✓ s �` �'? r ,! y y r > * c" �'IF*� { d �' i' m .�,rr- 3 4 ,>k A m. r. a rr3 n - a? 9 8� a 7"b k � t F i yy{[T xti @ r 1 Q - i �' ^T. 1 1 E. d.^ % M�"Alnn �m f.£, e2- � �li, � i(� �h. `. W+t'�, .�y j'�'IX 4� SS' i5FI - 41111;111.ii 14 q r`.1 I > 13 zIm ^,d'.1 t[ C A �7� „sy r.c Kh -�ra^v zit° +� b-' `" q 4- n ry a "�� Y *'e 51. y rt a x' k � � 5�' r ro , C '£ �� +r i�t r 3 ri $ s i ,. ;+4 li. r,° a.. �,u+; 1:1 !71il ,�.� ,� r , _ " ,�t ds ,+�, s s x, �� c K ` i li pv rt �Y !mss "* t J { �� �-, vS11 '; ?" k�p5 -r a'4 , ,;f, 1 #Y§ _. kF `S. ''!• Jy-ry {{ y T •�-"r} I _4 fa �{ ''(y k,T, �'R'" 11 ..a f.+ If. :a"\ �{�7`" Nk l111 y k'. io� &� }��ft ^ Y, ' 4 F. ) S - A; I- :,y'4-f ,P SPY C,. �*' � s ? � �. r �,''-1 ? 4x` . �' .f d r�r +rc5 {_ t"+ ¢ { .' '` ` n �5 : a i 'x :a .enc` j 1� "i t t17,� - !k ig ` `., Sra '.r.-"',v, _ 1 �.i L ��- �`t ,rY`av' � jiw,, ��,�d •'-xr'' f "�'�`{ e 1A� Y J { '1�t �"#rk ' m) ywr l✓x.`3t {. * `` t. -• r a h .r p q a - ? v sT'f, 4 j, J t y o_ •f 'i -'t ..� , g a .' ,� a."kr5 �'a. �i r .a+ xry` sr 'F �� r3 f�' it3'�',�+ `il—Iil—I �`s M. �`P: c k-" [3 TP t, ` `.E' a, r'"{ ,.'^:�� s" '', t. '.xx. y ``{, 1 a fit},__,,4;_,'�"$ ''�• V- . ,Sr a• xk.,, 'A ?..- r i ' Ml1.�v I t7�� tom. r_ d r 'sem{ i r�k ,y�.h�f .as '_' ��;k e`"a z., 1 - q��` ii a ,a�, ;x'."ni t, 4"'�R` )-'�."-. c .,p n ."F t^ct,r 1� 4: "r` F Y ,y 1 t -swirsb Ci t s `'r,^f t 5�3 -` .'�j e.. .t 45 § '- x .a x ;Y ti i -q r a^n E q �. t b.ur a .,,+ v, _ � �►" 6 a 1 r 1 k * . 1 h t s , '" x ;� )fa ' �YPi t f✓ - k y- r i� '"t }`c s`3 F •a.,'� x _c � s ' -:,r r S._ x,** - a S s`W S. i k ` s Ct t a5 :t >. '' 3 .liFF.� =l.qS- , '�J ..i1` A '�ysi 71 2d �' .. ,F'y ,-L .r3, "v` y"�,r !I tip. g"x' .,,�fy'.,�N iE. i .� r - t o r s- v w -R Y w! € y� ,` r .� q s ds. x e "� kr" z, s - ' `^ �'� i '! y -L� k4' <sr ../. #,v I RS{ /p4' f i" is t t. ' ° d ><, .y, "r �9 q ^.ae' c. °r . 117� 'semi. *'s' .3`., :, 1 dX s n� .K ,v,l W li tra r 1 - P¢ t; ?Y q;x ,.. s .-# u '}"ter vl�r t+' +� ,;t �. r A �` .*, 5 i t 3 `7Y 5` -x rtl�l i:^ . z`- a s t t ` ." }��r•„,. " +' x qr t- a".r a $ linEr^ moi. } i ^, �e a- _ t 3� N '%r,? t-. r ' _ Y 11 ,fit '"g t rq�.� h„� ,.,c a rya#.ax'' ,3 Y z _rq ii , t { x.' F ; 7r _ !t a1. - 7 a ss s s a s 1'�. 4 K r s '--,- , x 5 �? L x58 .� r � '" ,r r & x 2 tpn t .'°' s..� �.''31�R,,h.� '�y'�FS -s , d r x ,� r i t K "r r `� ' ate' �. - s ,+., 7 :. 5 , , R�r , "� a xr"1 `'.1. ''"t it v� rr w.e+1ne�e.r a..d .w��+nxi + '"'a'.,d a*.' x 9 x t w - -��♦{ ,,,,,mac' : y a"'i't __n x ���}+ r s a,r.,-% : ,+',I ry , Q[..l+J1iLC'r �1 f{ �. 3 & {' .F T" 1 4llCrt if^" ' 4 'S w r��s„� .k- fr x k 7 '� �' - FM,,Z`nn d” ,� r,. ,,,_f ii .r z d ' ��`}'�i '` r 4 1 S s l..",}� J ;T��,', — -y'�iy� 'E• ;:i,:tl��],,j�`, s�.- 'w'?rk- x,a 4e 'x. � 74",>' '.MY q 4` C }P s I� 77" I #1,7 T '`���1�fi „ t y�re's 'X A 4. 4 y E d�`iP'� iR t°}1 tl �.[ �R$�5s, d� .F4", Ssi, 'f h { h"- 1 f 'J r `1 2; S t' $t ✓.c. c .ry fit. I a r -t .,' , t a t x r 1 - -r �'- r r -y F r < :.<1 5r r c p+ x ) d 1 `_ r 3 * � r i �, -Y x „4x 1 T v d § ;. r - { 4L r n ' #' '� ' 1 F x ' r T9' - -;,4 r )y 4 6 - 3 R�-`v o f l`sf a a ...�`" 41, �1 �.. e - F : „e t '"t aI 11: ,t K. tr -a nY�l `ii i xrE vcy )C t3.. !w i, $ *��,35+eY"t 3+d`t{ k 3 .�, tc L .na.�ir sie- '°�rit ,- -: x �.{es Y i & wsFi f T''� # 1};.i. " -t f i4, f Ursa ;ix"}f y'e't �ti:.�„rr.. „St ,�Z� syu "�Yy� 'S `- "';�t Y d`s+.,'+,4 i%z � yTn,x'R'i.•" •v l "` ? a i 1"'`.�vyi }�", s„' 8, `��< c 'S,, '� �:i 3d' ,f %�' 'i r ! c , x `.f 'a x J '' }_ r `, ff'- a4'v �3y � Y.w'r !�t ,'�'x xu” x. i s i., `�y r� -••t' �u' '}Y,i '"✓v.?i� -1 '} q - r �i�' 4 '+c, '$ w 7 �,-fi 1 Y- `` E 11 )N A .:7`M'{rih4 `. k t a, wi_ L ars;moi VArm"5+ir,t `` a: 4.i Z�,1 g"'-�r'� r z rf'� -11 .y'`'� b c p. � �'� erg �,. t w >: q-- 5 �� b "* > e 4i ,M F '�tt e �.5 t `a ti Y rnt a E +-'`yFa <k 'v,+.:` 3 u raFt c r a. �,. r ' ss ms's t .,., r, , ✓"✓t aY` r t ^v. a� �u uxx .gy`Y:h� ��'( ,. t a ar r -�t-L Y� ,k s 3�- i rsEi rF -i s. { .r xt, �k t'r,;'Sf dw 1a�tan C. C►. i�tO t�1Cj .-nh.�l s STRUCTURE INFORMATION: 1.Structure Dimensions 1.Structure Dimensions(continued) 2 Type of Constriction a.Length(ft.)-- 01011 1011 Number of bedrooms= ❑Wood/Frame b.Width(fL)= 0-70 a r P Number of garage stalls: ❑Masonry J� Areas In square feet Attached= Metal ❑Pole Bldg. c.Basement= Detached= ❑ICF d. 1 s<Story = ❑On-alta Prefab e.2nd Story= ❑Off-site Prefab f. 'A Story = ❑Other(please spe ify}: g.Total Area= REQUIRED SUBMITTALS: All of the information must be submitted in order for your application to be processed: Not Enclosed Applicable ❑ ❑ Permit Application ❑ ❑ Proposed Building Plans O ❑ MN State Energy Code Calculations and Mechanical Code Requirements Form ❑ ❑ Survey meetin all uirements ❑ ❑ Stormwater Pollution Prevention Plan ❑ ❑ Hardcover Calculation s ❑ ❑ Septic System Site Evaluation Report ❑ ❑ Access Permit ❑ ❑ Wetland Buffer Improvement Plan ❑ ❑ Engineered Plans for Retaining Walls 4 feet or above ❑ ❑ Minnehaha Creek Watershed District Perm-8) ❑ ❑ Plan Review Fee ❑ ❑ Other. APPLICANT/OWNER ACKNOWLEDGEMENT: • Agrees to provide all information required or requested by the Building Department; • Agrees to pay the City of Orono for engineering consultant review ants In excess of$M; • Certifies that the information supplied is true and correct to the best of his/her knowledge. The applicant recognizes that they are solely responsible for submitting a complete application being aware that upon failure to do so,the staff has no altsmative but to reject it until It Is complete; • Acknowledges the Escrow Agreement is completed and signed; • Understands some or all of the Information that you are asked to provide on this application is classified by State law as either private or confidential. Private data is information which generally cannot be given to the public but can be given to the subject of the data. Confidential data Is information which generally cannot be given to either the public or the subject of the data. Our purpose and intended use of this information is to annually update our records and records of other governmental agencies required by law. If you refuse to supply the Information,the application may not be issued. • Agrees that In the event that weather or other conditions prevent the-completion of an-as-bunt survey at the time the Cerocats of Occupancy is requested,a temporary Cer6fli:ate of Occupancy Wray ba Issued upon.receipt of a-$10,000 escrow to ensure completon of the as survey and all site Improvemmnfs. Applicant's Signature: Date: Owner's Signature: Date: Packet Last UpdateaF. 0411 MO13 Page 23 of 23 OL 0 W IL EL Z 1ST EDITION - STERLING POOLS 0 MAIi rn v I—z—o" () . COPING ;r' a M 0 IMF CO TURNBUCKLE DEADMAN 4j PLATE STEEL POOL PANEL-- VINYL LINER I i� ONE PIECE FORMED ANGLE BRACE ~` CONCRETE FOOTER D6" DEPTH MINIMUM M tJ CONCRETE POOL BASE—N` _ STAKES' TYPICAL SECTION AT THE POOL WALL SYSTEM PANEL BRACES 4 NO SCALE 4-10-00 Installations to be in accordance Meets Depth and Shape minimum with Manufacturer recommendations standard of IRC 2000 and ANSI/NSP15 ICBO Report #3432 THIS BROCHURE 1S FOR ILLUSTRATIVE PURPOSES ONLY The manufacturer makes only those representations which are stated in Its written warranty. Any other representations, WARNINGI statements, or contracts made by the dealer and/or the contractor to the customer regarding any materials produced SWIMMING POOLS ARE DANGEROUS WHEN USED IMPROPERLY. by the manufacturer are attributable to the dealer and/or the CONSULT YOUR DEALER FOR SAFETY INFORMATION ❑N THE contractor only. The dealer or contractor who sells or Installs your pool is the Independent contractor and not agent or SAFE USE OF SWIMMING PO❑LS, IT IS THE RESPONSIBILITY employee of the manufacturer. Thme construction methods OF TOWN OFFICIALS, BUILDERS AND HOMEOWNERS TO FOLLOW illustrated ore suggestions and apply only to normal ground ALL SAFETY RECOMMENDATIONS OF N.S.P.I., ALL LOCAL conditions. There may be additional precautions and/or ORDINANCES AND EQUIPMENT MANUFACTURERS, methods of constructions. The responsib"Ity Is the contractors. — — — ALL ITEMS FOUND ON THIS PAGE APPLY TO ALL POOLS CONTAINED IN THIS BOOK — — IN ACCORDANCE WITH ANSI/APSP/ICC-5 2011,THE INSTALLER IS RESPONSIBLE FOR PLACING ONE SKIMMER FOR EVERY 800 SQUARE FEET OF SURFACE AREA AND ONE 8' 8' RETURN FOR EVERY 300 SQUARE FEET OF SURFACE AREA. SKIMMER 61 8' 81 RETURN 2'LA R H16H1 r i 4' !)1 •� ------------------7' wA ) �+ Is f � + ) i r Jur: 20 12' i � i sAFeTr Dace 4, i LIGHT t I i A%b I.OAT Oa / 1 1 1 j + ' ---------------.---A. -�- ! 4' i 1 41 G♦ 1 81 81 8' 81 8' RETURN SKIMMER 3'-10'1 ------------------------------------*1------------ -- ------------------------ 3'-10" 6"wATERLI 8'-6" ----------------------------------- >--- -f 41-8" 'cc y 4' �-w--- 9' 1 14' 13' - 40' CERT#ESR-2782 OMEGA StwlRECTANGLE 20-0 x 40 I>.S:CNt w OR FaUtiIPR1E'Nf tit+RLr ItE CUSTOMER SRPr(v11NNEAPOLlS i.':�r'"�" � tTFStGNeI')Fr�R ',:1f,11,1L�JC At)(:f3,S AN:) 1/ tfate(4f:WS',+Lll:U IN AC;GORUANC.0 :,1111 !HC UI`11MG+SLIUIhIf E(1UWbst'N! JOB NAME KALIFORNIA 48" STEEL PANELS PERIMETER: 120'-0- VOLUME(USGillj 29300 rjnNa,r„s:TulteclSSNEr..rtlCtiTlot)s DWGS: SURFACE(JF) 800 VOLUME(Lilers): 110900 ” F'l{;WI l:U!•713IA UFC:UIdINi,�;i)lU1tN: � LENJIP!dE':!ltltNUFfd:Tl11JL12 f(iii 2014-SPL-45262 LINER(IJlj 800 DATE 121412014 DsR 144 : T)!l:IrtsFF.cIFICA lrgNs TIFFt! 81156196 KIT#. CUSTOMKIT COVER(8°): 024 SCALE' 1i8"=1'-0" ST,tNW F±U�N7)kkPSRN:�-i 7.07 i RECTANGLE SHEET' t OF 2 7 m N N r r N U`f •S -r N N ^i` C•'Y N�C TS �t a •C) 11 N 67 N LU Z J U •7 V:Q �. `S Q cc op op CV !i ice.LO N '7.-_ N c^:7 LL) LJ W = � u Y O t a � z U tri�,•,►-- `v-? ti U ]G W U C) Z a J � SCJ CV CSO ib M�ice-CS i m N --7 L°u- 0 W C7 Y r` N • ;.,�N v =1 CO ZO ca ZD Q• N rII th U 0.' m � 'Y �^ X X XAw qXq N G O t"i 0••-=d r 4 C O O p O<3 c?ED z- A • Nin ei °�CO t4 v CV Q C/) S O 0005Ly �j � Nto V- .5 ov Ll. 2 d •-CV t'J-'r ts'7-14;; IJ N V7 ;; Q CO to i i I N I a rr a f o f N I C -_--------_.-._- -_.---_.-•___-------__-. I 1 ,t �'►10 t r 1 , t , It 7 i If { � r I 1 , It t 1 1 1 , I t x t I � t•7 t _ Q I t O I O cli1 -j t 1 i C9 I ' Z Q LLJ 7 ! v N 1 1 ' to I O d O O 1 1 { co o`, cry co. In . aC)M c�cgccot? ¢ Ca -tr�1'_• O O�S G�7 [V ice-:-CO CQ nO. :IL:" C3 %0cn ,T Lo! in at at 0 0 0 o o-, a Qz (nZ�N�".Z✓ rNCV 04 t'1 r7 - rim. " !' s -M ••tS1. i ss , i a w. 3 0 Q > 0 -o 0 L_ T _ L d O D Y L m � O k O O N r i d � O G O q � L W H O 0 V1 O C r `O W o o W a_ Z Y Q � V O T r � d Q wp 'C W O O- �x 0 a > w I C O d r O � O C a o E o W O = � � R N � T � T f o a L c i V s a C:) Q > z � o O d ` � dw> 1--• Q d c �k tti i' i 1 r i 1" r i _ ,.. .. KEEP OUT THE DIRT AND LEAVES. KEEP IN r WATER, HEAT AND POOL CHEMICALS. y i Like a lid on a jar, the Coverluxe system prevents leaves and dirt from getting into your pool while keeping the good things like heat,water and _ chemicals,from going out. Spend more time enjoying your pool and less time worrying about maintenance,upkeep, chemicals,heat,and safety. Most of the maintenance and cost of pool ownership can be dramatically reduced by covering your pool when its not in use. Coverluxe pool cover systems provide up to: �e +� 8-10 degrees warmer water 90% reduction in evaporation 70% reduction in heating bills 70% reduction in chemicals* 'US Department of Energy-AESPEC Program a - m a.s a ■ � � t ,� PEACE OF MIND. ' Concerned about pool safety? Every pool owner should be.Fortunately,the Coverluxe system is a UL®approved safety cover and also meets all ASTM'' powered safety cover requirements. It's an additional layer of protection that gives you the kind of peace of mind you need to enjoy your swimming s pool for years to come. sii,1� ��I- dk rte, LJI ULi JJ LJLI ■�'` "{ -� -4r-. Ar 4P 1 The American Society of Testing and Materials has created i a standard for powered safety covers.Coverluxe is classified >y V� � and tested by Underwriters Laboratories to exceed this F1346-91 safety standard.In addition,(oveduxeisULlisted to meet all electrical and safety standards. y - - n , w ismtended that people ... 1— wouldwalk onthe pool mve. .�.� ' �,�. - onlyinanemergency- ALb y TOPGUIDE SYSTEMS -For freeform pools The Coverluxe pool cover glides through two aluminum guides that are recessed in the deck during pool construction(Recessed Horizontal System)or if preferred,low profile cover guides can be mounted to the surface of the pool deck after it is finished(Standard Topguide System). 5 Standard Topguide System .s 41 t, 10 3 Recessed Horizontal System(optional Flush T rr �' _ 'u.. f`Ri ♦ 72tiai+ /•y U System shown) , .1- r' w' 'h�' i i. ,A: * t� •Y f Ali- UNDERGUIDE SYSTEMS For a clean,integrated look,the cover guides are _ encapsulated into the pool walls(Rectangular pools only)under the pool coping,allowing them to ` ' • remain virtually unnoticed. w, Underguide Systnrn COVER GUIDE OPTIONS Standard Topguide Standard Topguide (Moomed to top of deck surface) Recessed Horizontal Guide Mstanednushwimdedcsurface) Encapsulated Underguide FABRIC COLORS* — Recessed Horizontal . Encapsulated Underguide Navy a Royal Blue Light Blue Forest Green Tan LID STYLES Standard Aluminum Lid Standard Aluminum Lid Flat Lid Flush Deck Lid Brown Flat Lid "s^ 44 - Gray ' .. •Flush Deck Lid Otarcoal Black *Cover colors printed above and fabric • / samples will varybyprinting and batch. - - Coveduxeisa"wtwlesaleanly"manufacturer. No reseller is an employee,agent,or a s, representativeofCoverluxe.Specifications, ' descriptions,and diustrative materials contained herein are as accurate as known POOL CORNER OPTIONS at the time of printing.Coveduce reserves Square Corner 6"Radius Corner,2'Radius Available Underguide Encapsulation three tight to discontinue models or change Square Corners Rounded Clip-on Co in Formed Concrete Coping ei rinting,m without he information in me -Inclined Clip-on Coping P P 9 P g ofreprinhrg,sameottheintormationinthis 6"or 2'Radius Corners brochure may have been updated.Ask your �' dealer for details.Copyright 02107 Coverluxe. •3"Chopped Corner /' This brochure may not be reproduced wholly A or in part without written permission of Coveduxe.The Coverfine name and logo are _ registered trademarks.ASTM International ,!. 'a-y,- is a registered trademark ofthe American Society of testing and Materials in the United States and other countries.UL is a registered trademark of Underwriters Laboratories,Inc. in the United States and other countries.APSP is a registered trademark of the Association of + Pool and Spa Professionals. COPING STYLES •Reusable Concrete Forming System (Por VurylLmermGunite Pools) - Inclined I Cantilever • I � r� i rr Aluminum(lip-on Coping For Vurylliner Pooh On,y) / --,—'' Rounded IL °y Inclined ;- +C Cantilever i I, v`• '' Rounded Bullnose Inclined Aluminum 1-Piece Coping (for VinyttnerPools Only) Bullnose Inclined Formed Concrete Coping Aluminum Clip-on Coping Aluminum 1-Piece Coping ForVinyl LinerorGunite Pools ForVinyl Liner Pools Only For Vinyl Liner Pools Only COVERLUXE`RELIABILITY BY DESIGN All Coverluxe components are extremely tough and dependable. Only the highest quality materials are to used to ensure the maximum life of all system components in the harsh pool environment. Ask your pool builder for details on how you can incorporate the Coverluxe automatic pool cover into your pool design. I Coverluxe distributors and dealers are independent companies that search the industry for the most reliable products for your pool.These distributors and dealers are the most experienced in the industry and are ready to serve you and support your Coverluxe system. Member of Coverluxe 7v 1795 West 200 North 1 PSP The Association of Lindon,UT 84042 Pool&Spa Professionals- 1-800-418-4850 I I I I IIIIIII I II III'I III www.coverluxe.biz L9746 ©2005 Coverstar LLC Ver 3.0 Jan 2010 HAYWARRY Super Pumpo MEDIUM HEAD PUMP SERIES Efficient, Dependable, Proven . The Hayward°Super Pump series medium head pumps set the standard f for excellence and value. Designed for in-ground pools and spas of all types and sizes, Super Pump features a large see-through strainer cover, super-size debris basket and exclusive service-ease design for extra convenience. Super Pump combines proven performance with quiet, efficient and dependable operation. %iamb, � war a See-Through Strainer Cover lets you see when basket needs cleaning and eliminates guesswork.Special self- Heat-Resistant,Industrial- adjusting seal ensures dependable sealing. Size Ceramic Seal Exclusive,Swing- is long-wearing and drip proof. Away Hand Knobs make strainer cover removal easy.No tools required... no loose parts...no clamps. — Heavy-Duty,High- Performance Motor Super-Size Housing / with air-flow ventilation for and diffuser ensure quieter,cooler operation. rapid priming .-•• ••"'' _ - Mounting Base provides stable,stress free support,plus versatility for any Corrosion-Proof Impeller installation requirement.Adapts 48- has smooth,wide openings to and 56 frame motors. prevent fouling or clogging. Service Ease Design Self-Priming gives simple access to all internal parts.Motor and entire drive (suction lift up to 10' group assembly can be removed,without disturbing pipe or above water level) mounting connections,by disengaging just four bolts. PowerHorse Size OVERALL DIMENSIONS MODEL Total HP Service inches inches mm r FactorHP r' Energy Efficient Full-Rated Single Speed S2607EE 0.99 1a 1.32 114 15 381 q . SpeedStandard Ffficient Max-Rated Single SP2600X5 0.60 1� 1.20 i 114 131/4 A337 .p.. -- ._. Si0.75 'A1.00 114 13% SP2607X10 1.10 1 1.10 1 h 14% 362EL 10-7/8" 08 mm SP261OX15 1.50 114 1.00 131 153/6 391 7-3/41) SP2615X20 2.00 2 1.00 2 15% 403 Si 2.50 214 1.00 2 is als Super-Size 110-Cubic- i�(2si mmi �isemm a-5re^ Standard Efficient Max-Rated, ••d Inch Basket (L79 mm sP2607x102S 1.00 1 1.00 2 13 330 has extra leaf-holding capacity SP2610X152S 1.50 1111.00 2 133/4 349 and extends time between SP2615X2025 2.00 2 1.00 2 141/4 362 cleanings. Rigid construction with load-extender ribbing SUPER PUMP ensures free-flowing operation FLOW VS.TOTAL HEAD 10000 for heavy debris loads. 90.00 w 80.00 3 70.00 O 60.00 O 50.00 Super Pump Series Pumps are listed by: 40.00 3e.99 6P2421x26 sP2616X20 10.00 sP2410%15 SP240n 10 0.00eP2st 0x1623 w fiP2606X7 P2607 9a 20.0 4m eon Bao 11" 12W 14x0 FLOW(GPM) To take a closer look at Super Pumps or other Hayward products,go to www.haywardpool.com orcal11-888-HAYWARD o�Haof��d��esstries���� 101HAYWARlY 620 Division Street I Elizabeth,NJ 07201 HAYWARKY Universal H -Series POOL AND SPA HEATERS Right for so many reasons. Perfect for so many applications. o, s *° ii Hayward' Universal H-Series Heaters: Energy efficient and universal fit for added convenience . Hayward is always looking for ways to make pool and spa ownership z) z as affordable and effortless as possible. Our Universal H-Series pool r and spa heaters combine advanced technology with universal-fit flexibility, Ids *9 making them a smart choice for virtually any new installation or system upgrade. They deliver state-of-the-industry performance, save up to 18% on energy costs, have extremely low NOx emission levels and a legendary reputation for durability. They're offered in 150,000, 200,000, 250,000, 300,000, 350,000 and 400,000 BTU/hr. models. Easy installation, simple operation. A choice of left-side or right-side electric, low-profile appearance and front-panel gas and water connections gives Universal only access required for both installation H-Series heaters unprecedented installation and service - ensures compatibility with flexibility. This enhanced adaptability- virtually all new or existing systems and coupled with a lightweight design, a modern equipment pad configurations. Exclusive to Universal 1030, 1 11 H-Series � o WW STANDARD Cupro Superior Hydraulic State-of-the-Art Finn Dual Voltage Heaters Nickel Heat Exchanger Performance Plate Heat Exchanger Installation is simplified Totally Managed Flow Industry-leading hydraulic State-of-the-industry Finn with voltage that adapts provides exceptional performance saves Plate heat exchanger with to either 110V or 220V. corrosion resistance and energy by reducing special V-groove design erosion protection.Ideal for circulation pump run time. for faster heating and today's salt-based electronic longer life. chlorination systems. Q s � y Al R H150FD Universal Wiring Hot-Surface Silicon Digital LED Control Panel Insulated FireTile® Low NOx Emissions Junction Boxes Nitride Ignition System Electronic control Combustion Chamber Environmentally High and low voltage Exclusive silicon nitride display maintains water Unlike older forms of responsible;complies connections are easy and ignition system for temperature;monitors insulation,FireTile securely with all current California convenient with left and dependable lighting and heater performance with traps the heat,delivering and Texas air quality right side junction boxes. reliable operation. self-diagnostic capability. the most performance emission standards. from each BTU. M � Selecting the correct size Specifications and H-Series heater: Dimensions: For Your Swimming Pool Universal H-Series Heater Determine your pool's surface area in square feet: H400FD H350FO0 D H200FD 400,000 350,000 300,000 250,000 200,000 150,000 A B L " 36" 33„ 30" 28" 25" 21" L R W 2911" 2911" 29Y2" 2911" 29Y4" 29Y2" 24„ 24" 24„ 24„ 24" 24" Area=(A+B)x L x.45 Area=R x R x 3.14 Area=LxW 2"x214" 2"x211" 2"x2Y2" 2"x211" 2"x212" 2"x211" Cupro Cupro Cupro Cupro Cupro Cupro Nickel Nickel Nickel Nickel Nickel Nickel In this table,locate the surface area that is equal to,or just greater than,the pool's ", .' 8" 8" 8" H4O0 1,200 surface area.To the left of this number is the H35O 1,050160 158 145 134 123 110 appropriate H-Series model that will fit the H3OO 900 selected area. ' ' 3/4„ 3/4„ 3/4„ 3/4„ 3/ 3� H25O 750 For indoor pool installations,divide the pool's H2OO 600 surface area by 3. H15O 450 Table is based on a30'Ftemperature rise,334mph average Millivolt Heaters wind velocity and elevation of up to 2,000 feet above sea level. H250 H200H150 250,000 200,000 150,000 For Your Spa or Hot Tub 127" 2411" 2114" 1.6 2731" 2714" 27Y2" Determine your spa capacity in gallons(surface area x average depth x 7Y2). 2811" 2831" 2811" The reference table lists the time required in minutes to raise the temperature of the spa/hot tub by 3O`F.In the table below,locate the column with the spa/tub size in gallons 1 Y1"x 2" 1 Yd,"x 2" 1 Yd,"x 2" that is closest to yours.Select the desired time to raise the spa/hot tub temperature 30°F, �' Cupro Nickel Cupro Nickel Cupro Nickel read to the left and select the appropriate H-Series model. off 7" 7" 6" This guide can be adjusted for other temperature rises.For example,if you desire a 15'F 17Ya" 15Y4 14" increase in temperature,simply divide the time for 30°F rise by the ratio of 30/15,or 2. 144 141 131 Note:Heat lost and/or heat absorbed by spa walls or other objects will add to the time 3/" V" Y4 it takes the spa to heat up. Spa sizing is based on an insulated and covered spa.Always cover your spa or hot tub H-Series heaters are available in a comprehensive range of BTU sizes for natural or propane when not in use to minimize heat loss and evaporation. gas.All units are certified by the Canadian Standards Association and carry the exclusive Hayward®warranty. SPAfTUB SIZE IN GALLONS 200 300 400 500 600 700 8W) 900 1.000 ODr r H400 9 14 19 23 28 33 37 42 47 H350 11 16 21 27 32 37 43 48 54 .1 H300 12 19 25 31 37 44 50 56 62 H250 15 22 30 37 45 52 60 67 75 H2O0 19 28 37 47 56 66 75 84 94 H150 25 37 50 62 75 87 100 112 125 Performance. Innovation. ® Efficiency. Whether you want to extend your swimming season or swim year-round,Universal H-Series gives you comfort with efficiency.It's the perfect addition to your Totally Hayward®System. To take a closer look at Universal H-Series Heaters or other Hayward products,go to www.haywardpool.com or call 1-888-HAYWARD Q HAYWARKY 620 Division Street I Elizabeth, NJ 07201 Hayward,Hayward Energy Solutions,Totally Hayward and A FireTte are registered trademarks of Hayward Industries,Inc. 02011 Hayward Industries,Inc. L rHS11 -- HAYWARKY Pro Series TOP-MOUNT SAND FILTERS Hayward Pro Series high-rate sand filters offer the very latest in pool filter technology with smooth, efficient flow and totally balanced backwashing. Pro Series sand filters feature unitized construction of corrosion-proof, polymeric material and self-cleaning 3600 slotted laterals.A versatile seven- position control valve offers both easy operation and maximum efficiency. For crystal clear, sparkling water with minimum care, Pro Series filters set a new standard for performance, value and dependability. R z op Integral Top Diffuser ensures even distribution of water f, Flange Clamp Design over the top of the sand media bed. allows 360°rotation of valve Full-size internal piping gives smooth, to simplify plumbing. free-flowing performance. Efficient,Multilateral Unitized, Corrosion-Proof Filter Tank Underdrain Assembly molded of tough,durable,colorfast with precision-engineered, polymeric material for dependable, self-cleaning 360°slotted all-weather performance with only laterals give totally balanced minimal care. flow and backwashing. Totally Corrosion-Proof Base Integral Molded Drain Plug is rugged and attractively for easy draining of tank, styled to provide strong, without the loss of sand, stable support. SPECIFICATIONS — ..O SERIES HIGH-RATE Filter Type High-Rate Sand:No.12 Silica Sand(.45 mm-.55mm) Filter Tank I Molded Polymeric Underdrain 3601 Self-Cleaning Slotted Laterals,Precision-Installed in Ball Joint Assembly Control Valve 136"or 2"7-Position,Top-Mount Vari-Flo"with Lever-Action Handle Valve Fastening Flange Clamp Design SupportBase I Injection-Molded Polymer Performance Range 30 to 120 GPM,114 to 454 LPM S180T—1812"W x 35"H(470 mm x 889 mm) S210T—2012"W x 38"H(521 mm x 965 mm) S220T—2212"W x 41"H(572 mm x 1041 mm) Dimensions S244T—2412"W x 42"H(622 mm x 1067 mm) Var.-[-10 7-Position Control Vaive S270T—27"W x 43"H(675 mm x 1075 mm) with easy-to-use lever-action handle lets S270T2—27"W x 43"H(675 mm x 1075 mm) S310T2—30 Yz"W x 48"H(775 mm x 1219 mm) you "dial"any of seven valve/filter functions. S360T2—3512"W x 53"H(895 mm x 1346 mm) PERFORMANCE DATA Patented Service-Ease Design EFFECTIVE DESIGN TURNOVER SAND with unique folding MODEL FILTRATION AREA FLOW RATE" GALLONS KILOLITERS REQUIRED NUMBER ball joint design allows m 8 hrs. 10 lateral assembly to S180T 1.75 0.163 35 132 16,800 21,000 63.59 7948 150 68 1 be easily accessed S210T 2.20 0.205 44 1 167 21,120 26,400 79.94 99.92 200 91 for simple servicing. S220T 2.64 0.246 52 197 24,960 31,200 94.47 118.09 250 1114 S244T 3.14 10.292 62 235 29,760 37,200 112.64 140.80 300 i 136 S270T ; 3.70 0.345 74 285 35,520 44,400 134.49 168.07 350 1159 S270T2 3.70 0.345 : 74 1 285 35,520 44,400 134.49 168.07 i 350 159 S31OT2 4.91 0.457 98 371 47,040 58,800 178.05 222.56 500 i 227 S360T2 7.06 i 0.660 141 535 ! 67,680 84,600 ! 256.20 320.25 1700 ' 318 1NSF, `Based upon 20 GPM per ft.2(814 LPM per m�.Maximum allowable NSF rating. To take a closer look at Hayward Filters,go to www.haywardpool.com or call 1-888-HAYWARD. 10 HAYWARD° Hayward is a registered trademark and vari-Flo 620 Division Street I Elizabeth,NJ 07201 A Is a trademark of Hayward Industries,Inc. 02011 Hayward Industries,Inc. LIPROiM1- i 1HA YWARKY r . 4WD x #� Universal ColorLogic® COLORLEDPOOL AND SPA LIGHTING l THE BEAUTY OF LED TECHNOLOGY Universal ColorLogic®LED lights are 100%brighter'than current color LED lights,and 50%brighter than the leading competitors'standard SAri light.But the real beauty is in the savings.Pool owners can upgrade from incandescent lights and save as much as 86%on energy costs.These One light... LED lights last 20 times longer,virtually eliminating service calls for burned out bulbs.There are no bulbs,filaments,color wheels or moving parts. changes everything. {. ing. `f THE SAFETY OF HAYWARD®LED TECHNOLOGY Our 2-wire low voltage light is made entirely of high impact plastic with an unbreakable lens and no exposed metal components.These are all reasons why UL lists it for safe installation in virtually any niche. THE RANGE OF HAYWARD LED TECHNOLOGY — i I Universal ColorLogic Pool and Spa lights are available for two primary means of control;they can be controlled by simply toggling your standard light switch or by '0/ rr using your remote control.Networked models are designed for advanced orchestration and control when used with our Pro Logic®controller and when using Pro Logic,it allows you to customize color shows with speed,motion and 101 colors. All lights ship with Smooth White and Silver Luster Starburst trim rings.Additional I rings to match your pool and spa are also available in White Starburst,Faux Chrome, Black,Blue,Beige and Gray. Easilyconvert your 120V lighting system to low wttaga using our transformer/J-Boz ONRCOLORLOGIc ■ s retrofit kit available for the most popular J-Boxes. uNIVERsacRrsruocic^ 9jos► If you are planning for multi-light installations,the Hayward 300 watt transformer is .......... .................................................... ,.e the cost-effective solution for these new Construction projects. TRANSFORMER/J-BOK REIROFrf Kits TRANSFORMER THE CAPABILITY OF HAYWARD LED TECHNOLOGY * t 33 These lights are UL listed for safe installation in virtually any niche,including Hayward,Pentairm,Jandy®,American®,Sta-Bite®,Puree,Pacab®,Swimqug® Q, i and CHD®niches.For additional information,please see our website. Universal ColorLogic is UL listed for wall and floor installation. For new installations,the revolutionary shallow pool niche that does clot require to be bonded or grounded,alloys you to further save costs on installation and •- iv a RArwARn oce{r.4P `7ICRFU.v THERMOCf— materials necessary to install this light. •Based o,measured nest data at lime N onnt, To take a closer took at Universal ColorLogic,CrystaLogic arother Hayward products,go to www.hayward.com or call 1-888-HAYWARO. �I HA"VARKY 620 Division Street I Elizabeth,NJ 07201 C UL ll {� nar„ve,xewe�e cn«arsdmPs cowtoa�Ecwsm a�a nokasa as A ooiz natwa�em dxesaeeo.r�r.�m�rnx.nc. p�M.N ea ne P¢eh b urea repenre atm. IywxAxm m.ye.,eaprM Mma mm•eeM�.+N+nrww niULLeN': l See the diffe' ren I one lighti e . Afterno n Skies A u.�Gire. Flamingo Vivid Violet Cyngd White Red I At last the light that changes everything! DAllLING LIGHT SHOWS MA ADO Voodoo Lounge ADDITIONAL LIGHT SHOWS When it's time to realty get the party going,uncork over When loregrated with Pro Laic Hayward®'s Universal ColorLogic is the first automated color changing °- 1,500 quick-changing colors for an unforgettable night. Rainbow pool light that can spectacularly illuminate nearly any existing pool or spa Enjoy every available color thanks to a radiant show roll With vibrant color.Specifically designed to deliver beautiful,rich colors I I ® Twilight through the cola spectrum. and exciting shows to pools limited by a single light,More lights?More _ Over 1,500 colors constantly change to create a relaxing brilliant,saturated color.Let your pool and spa set the theme for your and sophisticated mood for evening inti aiming, 1lik Harmony party—no matter what the holiday!Pool parties are now more fun and Tranquility Discover hew peaceful your pool can intimate evenings are more inspired. Set the mood for a relaxing evening with this serene show realty be with vivid blue/green light mix. Universal ColorLogicm with mixing calming dues and white. And now Hayward's design is UL listed to retrofit the vast majority of Pro Logic®is just too logical today's pools.They'll easily and safely ft virtually any lighting niche in combining our Universal CblorLogic with a Gemstone Custom Fade Vibrant blue,green and magenta make this show a priceless Program your own smooth fading light ust about I no matter when or where it was installed. Pro Logic control unit just makes sense these show using five fixed colas. any days.Not only do you upgrade to 101 colors choke for any pool party. 9 400 and 11 color-changing shows—all adjustable Universal ColorLogic patent pending LED lights are 100%brighter`than for speed,motion and brightness—you can , Lice an other color LED totally automate a pool,spa and backyard. Shows patriotic lot on the Fourth of Jul or me with a Custom Chase y pool light.It's optimized TIR optic casts and keeps sP Y mN Pool owners get more leisure tlme by star-spangled red,white and blue show. Program your own light sequence using more light throughout the entire pool.Now it comes standard with 10 ' five fixed colon. automating pH and sana¢atlon,filtration cycles vibrant colors and 7 programmed light shows to choose from,more and more.Using Pro Logic with EcoStar®— Mardi Gras t d inusry's most energy-efficient when used vvith Hayward Pro Logic Controls.You Can even install these the variable Kids and adults alike will love the 32 fast-changing colors speed pump—saves up to 90%on energy and carnival atmosphere created by this cheerful show. pool and spa lights as Close as 4 inches from the waterline to light even costs compared to ordinary single-speed Lights are compatible with CoArt is and Pentair®Salm' One shallowest areas.Transform your backyard into a color oasis with pumps.Pro Logic also lets pool owners controlbackyard functions like patio and yard lights, Cool Cabaret stand alone light shows,as well as ColorLogic 4.0 H ard's Universal ColorLo is LED lighting. and fire is. customized Networked Light Shows. ayw 9 9 9 Wad pumps a Hit the disco and tum your pool into a nighttime hat spot Timed an meesvmd rest data m fine of prim. with this vibrant show of over 100 colas. . e- 10 — r,' `DQE TIME CITY OF ORONO CALLED I V INSPECTION N QTICE //��+EDUt �'sem PERMIT NO. ald 14D��`� oMPLETED ADDRESS a OWNER TEL P NE NOP-1-72- -5 L5 CONTRACT `4& 1/ 60� 11/11Y DESCRIPTION ❑ FOOTING ❑ DEMO-FINAL ❑ UTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING H ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ PROGRESS ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP ? ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ HARD COVER REMOVAL v ❑ DEMO-SITE ❑ PTIC INSTALL ElFOUNDATION/REMOVAL Q OWNER/CONTRACTOR TO MEET YOU: YES_NO / o COMMENTS: / y CC W a O c r O s � W c Q 2 W W j d W ORK SATISFACTORY:PROCEED 11 PROJECT COMPLETE W_ ❑C RRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY Q ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY BEFORE COVERING PERMANENT O CORRECT UNSAFE CONDITION WITHIN HOURS. El PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 ho u in advan5 ) 249-4600 Owner/Contractor on site: Inspector. White CopylInspector's File �/ Canary CopylSite Notice /r DATE TIME CITY OF ORONO CALLED IN INSPECTION NOTICE SCHEDULED PERMIT NO. COMPLETED ADDRESS `_ / c OWNER TELEPHONE NO. CONTRACTOR DESCRIPTION /17 L,,Q12, ��21 k ❑ FOOTING ❑ DEMO-FINAL /^ (❑ SEPTIC FINAL Q E] POURED WALL ❑ PLUMBING RIIL_ r ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADO SLAB E] MECHANICALRI ❑ SITE INSPECTION _ ❑ F MING ❑ MECHANICAL FINAL ❑ RATED WALLS kSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT N A L ❑ WATER HOOK-UP ElFOLLOW-UP T ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL v ❑ DEMO-SITE ❑ SEPTIC INSTALL Z OWNER/CONTRACTOR TO MEET YOU: I YES_NO COMMENTS: CC W Q_ cc J O O LL W Q 2 W W Cr EC' ORK SATISFACTORY:PROCEED PROJECT COMPLETE W RECT WORK 8 PROCEED ]-ISSUE CERTIFICATE OF OCCUPANCY O O CORRECT WORK,CALL FOR REINSPECTION TEMPORARY U BEFORE COVERING PERMANENT D CORRECT UNSAFE CONDITION WITHIN HOURS. PHOTO TAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED D STOP ORDER POSTED.CALL INSPECTOR D INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. 49-46010 Owner/Contractor on site: Inspector. White Copy/inspector's File Canary CopylSi a Notice