Loading...
HomeMy WebLinkAboutfurnace specs GAS-FIRED, POWER-EXHAUSTED • 132% Thermal Efficiency • Horizontal or Vertical Venting • Field Convertible to PLQSa y%W1 Continuous Retry • Commercial or Residential Applications ``OO ptiance City of Orono, Date For applications requiring a low profile unit, Modine offers the Hot Dawg®unit heater. e o aw may be installed in residential or commercial application y� below the ceiling.The superior quality matched with the following features makes7the Ho Dt 1 choice for a variety of applications: kit 'r•82%thermal efficiency for fuel savings. • Uses natural or propane gas (field convertible from natural to propane gas). • Certified for residential, commercial and industrial use. •Lightweight,easily installs 1"from ceiling with only two angle brackets(standard on 30-75, accessory for 100-125). •Install quickly and easily with knockouts for quick access to gas and electricity. •The standard power exhauster allows the unit to be vented vertically or horizontally and is designed to use the smallest diameter vent pipe possible. MODEL •Permanently-lubricated motor for trouble-free dependability. • Full 10-year warranty on heat exchanger. •Available in both propeller fan and centrifugal blower configurations. The PDP (propeller) power vented gas-fired unit heater is a product that is inexpensive to install, L f easy to use, and offers excellent in-service economy.The PDP model series expands on the size range of the HD model series providing product that is certified for commercial and industrial applications in sizes from 150 through 400MBH. For blower model data, see page 8. ` Table 4.1 - Propeller Unit Model HD and PDP General Performance Data Model HD Sizes Model PDP Sizes 30 45 60 75 100 125 1S0 1 175 250 300 350 400 Btu/Hr Input OO 30,000 45,000 60,000 75,000 100,000 125,000 150,000 175,000 250,000 300,000 350,000 400,000 Btu/Hr Ouput O 24,600 36,900 49,200 61,500 82,000 102,500 123,000 143,500 205,000 246,000 287,000 328,000 Entering Airflow(CFM) 505 720 990 1 @ 70"F 160 1490 1980 2180 2550 3700 4460 4870 5440 MODEL • • Air Temp.Rise(°F) 44 46 45 48 50 47 51 51 50 50 53 54 Max.Mounting Height(Ft.)Q 10 10 12 14 12 16 16 17 19 21 20 19 Heat Throw(Ft.)@ Max Mtg Ht 0) 25 27 36 38 42 56 F55 59 67 74 70 69 The PTP features a stainless steel tubular heat exchanger as STANDARD on all units with a --r 10-year heat exchanger warranty, providing customers with a peace of mind.Users of the PTP will also benefit from a design that allows quick and easy installations. .-...o. Table 4.2 - Propeller Unit Model PTP General Performance Data Model PTP Sizes 150 175 200 250 300 350 400 MODEL • ► Btu/Hr Input OO 150,000 175,000 200,000 250,000 300,000 350,000 400,000 Btu/Hr Ouput i0 123,000 143,500 164,000 205,000 246,000 287,000 328,000 Entering Airflow(CFM)@ 70°F 2140 2725 2870 3995 4545 5280 5995 Air Temp.Rise(°F) 53 48 52 47 50 50 51 Max.Mounting Height(Ft.)(Z 15 14 15 18 19 18 21 Heat Throw(Ft.)(@ Max Mtg Ht) 51 50 53 62 69 65 74 O Ratings shown are for elevations up to 2,000 Ft.For elevations above 2,000 feet,ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.(In Canada see rating plate.)Reduction of ratings requires use of a high altitude kit. ®Data taken at 55°F air temperature rise.At 65°F ambient and unit fired at full-rated input.Mounting height as measured from bottom of unit,and without deflector hoods.For units equipped with deflector hoods. DO NOT LOCATE ANY GAS-FIRED UNIT IN AREAS WITH CHLORINATED, HALOGENATED, OR ACIDIC VAPORS IN ATMOSPHERE. Request Catalog 6-189 For Complete Technical Information and Specifications. Q 75-136.49 EA SCO PLUMBING& HEATING(Fq Print Date:02/05/2016 MR!, 14PA 14 Firmaces 95650 RtQht fargaa PG92SCS Up to 92.1%AFUE Single Stage 4-Way MUltipolse Condensing Gas Furnace The model P092SCS is an efficient and robust 4-way multipolse condensing furnace with features Including single-stage heating and a rugged PSC Slower Motor. The PG92SCS builds on the many Payne successes In the furnace industry and establishes a new standard for all high-efficiency gas furnaces. Standard Features • Direct-vent/sealed combustion,single-pipe venting or ventilated combustion air - PSC blower motor • 4-way multipoise furnace • Hot surface ignition • LED diagnostics and self test feature • Stores fault codes during power outages • Adjustable heating air temperature rise • Adjustable cooling airflow • Approved for Manufactured Housing/Mobile Home o applications with MH accessory kit • Approved for Twinning applications (48060 through 60120 sizes,only) !' , • Certified to leak 2%or less of nominal air conditioning •° " CFM delivered when pressurized to 1-inch water column with all present air inlets,air outlets,and condensate drain port(s) d sealed Limited Warranty* • 10-year parts and 20-year heat exchanger limited warranty to the original purchaser upon timely registration. • Limited warranty is five years parts if not registered within 90 days of installation. 'For owner occupied,residential applications PA PG92SCS30040A 37,000 920 985 PA 1l3 4 PG92SCS480608 56,000 1005 121 14.2 799.00 PA PG92SBS480808 75,000 1085 1505 1!2 5 142 1830 17.5 831.00 PA PG028CS60080C 75,000 112 5 151 17.5 1140 1960 3/4 5 844.00 PA P092SCS48100C 93,000 1475 159 21 884.00 PA PG92SCS60100C 93,000 1570 1/2 4 167 21 1640 X80 918.00 PA PG92SCS60120D 112,000 2355 1 5 167 21 942.00 B2 KGBNP50011SP Natural Gas to LP Conversion Kit 2230 1 5 184 24.5 1032.00 Furnace dimensions:35"height x 29-1/2"depth(for width,refer to"Cabinet Width"column above) 77.00 Page 5 EA SCO PLUMBING& HEATING(FF? Print Date:02/05/2018 Zre 13PA 3 Res Air Conditioning 96850 PA 13NA Air Conditioner 13 SEER with R-410A Refrigerant The model PA 13NA air conditioner is available in nominal cooling sizes Ole through 060. The unit features a copper tube,enhanced aluminum fin coil for compact,low profile appearance with vertical air discharge. Standard Features See PDS for performance ratings. • SEER 13 or more with specified indoor section • Copper tube aluminum fin coil • External brass front-seating service valve • Compressor internal pressure relief valve • Compressor internal overloads • Condenser coil grille • Heat pump style base pan • Totally enclosed PSC fen motor • Electric ground lug • Now features dense coil guard for added protection ull Limited Warranty* • Standard limited warranty: 5-year on parts,coil,and compressor • 10-year limited compressor,coil,and parts a YL warranties for timely registered original purchaser • Optional extended warranties available *For owner occupied,residential applications Qa tzart9 Vndr n 4 PA PA13NA0180G 208-230-1 3/4° 3/8" " d i PMS 3/8 24-3/16 23-1/8 23-1/8 120 PA PA13NA0240G 208-230-1 3/4" 3/8" 3/4" 3!B" 24-3/16 23-1/8 23-1/8 123 20 71100 PA PA13NA030BG 208-230-1 3/4 318'° 3/4" 318" 28-7/16 23-1/8 23-1/8 126 785.00 PA PA13NA036 GG 208-230-1 7/8" 3/8" 7/8" 3/8" 35-3/16 23-1/8 23-1/8 139 25 617.00 30 PA PA13NA0420G 208-230-1 7l8" 3/8" 7!8" 318" 31-13/16 31-3/18 31-3/16 187 897.00 PA PA13NA048OG 208-230-1 '7/8" 3/8" 7/8" 318" 38-5/8 31-3/16 31-3118 206 40 1046.00 PA PA13NA0800G 208-230-1 •7/8" 3/8" 7!8" 3/8" 40 1141.00 28-7/16 31-3/16 31-3/16 216 50 1326.00 Unit's performance was rated using a 3/8"liquid and 1-1/8"vapor lineset.Please refer to the lineset sizing guide for other acceptable Iineset sizes. Page 11 L_ y Easco - Orono Parking HVAC Load Calculations for Easco-Orono Parking Prepared By: Easco-Orono Parking Tuesday, February 06,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. yc rR ( nat Liglit'{tpltlEtlir+ ai H�11C L# da 613 8o'itw8ru,tJevelsfp{ITr�nt;,lf1+�; IElhe Supply Ind ' Egad-tirarto l�srliing r aro 'e{{ct Report Project Title: Easco-Orono Parking Project Date: Tuesday, February 06,2018 Client Name: Easco-Orono Parking Company Name: Easco-Orono Parking Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb ReLliutn ReLkLuID ry Bulb Difference Winter: 0.14 -11.42 n/a n/a 70 n/a Summer: 90 73 45% 50% 72 38 o� Total Building Supply CFM: 4,517 CFM Per Square ft.: 0.588 Square ft.of Room Area: 7,680 Square ft. Per Ton: 806 YVw�o«(lu�me(ft'): 135,680 rl3F ildlr� Fr Total HeatingRequired Including Ventilation Air: 332,170 Btuh 33 q 9 2.170 MBH Total Sensible Gain: 96,424 Btuh 84 % Total Latent Gain: 17,888 Btuh 16 % Total Cooling Required Including Ventilation Air. 114,312 Btuh 9.53 Tons(Based On Sensible+Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. � Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Easco-Orono Parking.rh9 Tuesday, February 06,2018,2:56 PM vac RIc�nflal, t i�htmat�ergtal HVAC 1, ds Eli 'Sc>twarp bevQiopment�ir►a: prut�dRaong Htlt" i Load Preview Report Net ft.' Sen Lat Net Sen Hts Cis Sys Act Duct Scope Ton lion Area Gain Gain Gain Loss 9 9 Size CFM CFM CFM Building 9.53 806 7,680 96,424 17,888 114,312 332,170 4,446 4,517 4,517 System 1 8.52 796 6,784 86,213 16,053 102,266 299,193 4,005 4,039 4,039 26x26 Zone 1 6,784 86,213 16,053 102,266 299,193 4,005 4,039 4,039 26x26 1-Garage 5,888 75,781 13,541 89,322 261,804 3,504 3,550 3,550 33--6 3-Mez 896 10,432 2,512 12,944 37,389 500 489 489 5-6 System 2 1.00 893 896 10,211 1,835 12,046 32,977 441 478 478 9x11 Zone 1 896 10,211 1,835 12,046 32,977 441 478 478 9x11 2-Office 896 10,211 1,835 12,046 32,977 441 478 478 5--6 C:\...\Easco-Orono Parking.rh9 Tuesday, February 06, 2018, 2:56 PM .. /N% ..► - • - rm Form �\✓1"�® Examiner RIPER 1.01 ,��� OIATe ft • - • •. • Equipment, 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information Contractor REQUIRED ATTACHMENTS' ATTACHED Manual J1 Form(and supporting worksheets): Yes❑ No Q Mechanical License# or MJ1AE Form'(and supporting worksheets): Yes❑ No M OEM performance data(heating,cooling,blower): Yes ElNo 0 Building Plan# Sys. 1 Manual D Friction Rate Worksheet: Yes❑ No 0 Duct distribution system sketch: Yes El Nog Home Address(Street or Lot#, Block, Subdivision) HVAC LOAD CALCULATION (IRC M1401 .3) Design Conditions Ruilding construction Information Winter Design Conditions Building Outdoor temperature 0 OF Orientation(Front door faces) North Indoor temperature 70 OF North,East,West, South,Northeast,Northwest,Southeast,Southwest Btu/h Total heat loss 299193 Number of bedrooms 0 Summer Design Conditions Conditioned floor area 6784 Sq Ft Outdoor temperature go OF Number of occupants _ 0 Indoor temperature 79 OF Windows Roof Grains difference 38 L Gr @� % Rh Eave overhang depth 0 Ft Sensible heat gain 86213 Btu/h <— Internal shade Eave Latent heat gain 16053 Btu/h Blinds,drapes,etc Depth Window Total heat gain 102266 Btu/h Number of skylights 0 EQUIPMENTIHVAC • 40 Hating Equipment Data Cooling Equipment Data Blower Data Equipment type Furnace Equipment type Standard Air Conditioner Fumaoe,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc Heating CFM 4039 CFM Model Model Cooling CFM 403A CFM Heating output capacity Btu/h Sensible cooling capacity Btu/h Heat pumps-capacity at winter design outdoor conditions Latent cooling capacity Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity Btu/h DISTRIBUTIONHVAC DUCT •1 Design airflow CFM Longest supply duct: Ft Duct Materials Used(circle) Trunk Duct: Duct board,Flex,Sheet metal, External Static Pressure(ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses(CPL) IWC Total Effective Length(TEL) Ft Branch Duct: Duct board,Flex,Sheet metal, Available Static Pressure(ASP) IWC Friction Rate: IWC Lined sheet metal, Other(specify) ASP=ESP-CPL Friction Rate=(ASP■100)+TEL I declare the load calculation, equipment selection, and duct systern design were rigorOLISly performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification. Contractor's Printed Name Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. a The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see list on page 2 of instructions. If abridged version of Manual J Is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edftlon Version 2 Elite Software Rhvec program. ,b 1.- Residential Plans Examiner Review • Form ACC" • • • . • Equipment, RIPER 1.01 Arca�sa� 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information Contractor REQUIRED ATTACHMENTS' ATTACHED Manual J1 Form(and supporting worksheets): Yes❑ No Z Mechanical License# or MJ1AE Form'(and supporting worksheets): Yes❑ No Z OEM performance data(heating,cooling,blower): Yes❑ No M Building Plan# Sys,2 Manual D Friction Rate Worksheet: Yes❑ Nog Duct distribution system sketch: Yes❑ No Z Home Address(Street or Lot#, Block, Subdivision) HVAC LOAD CALCULATION (IRC M1401 .3) Design Conditions Building Constr 1 _tion Information Winter Design Conditions Building Outdoor temperature 0 OF Orientation(Front door faces) North Indoor temperature 70 OF North,East,west, South,Northeast,Northwest,Southeast,Southwest Total heat loss 32977 Btu/h Number of bedrooms 0 Summer Design Conditions Conditioned floor area 896 Sq Ft Outdoor temperature go OF Number of occupants 2 Indoor temperature 79 OF Windows Roof Grains difference 3$ L Gr @ _9() % Rh Eave overhang depth Ft Sensible heat gain 1(2 11 Btu/h Internal shade <— Eave Latent heat gain 1835 Btu/h Blinds,drapes.etc Depth Window Total heat gain 12046 Btu/h Number of skylights EQUIPMENTHVAC •N (IRC M1401.3) Heating Equ*pmant Dat Copleng Fquipment Data Blower Data Equipment type Furnace Equipment type Standard Air Conditioner Q Furnace,Heat pump,Boller,etc. Air conditioner,Heat pump,etc Heating CFM 478 CFM Model Model Cooling CFM d78 CFM Heating output capacity Btu/h Sensible cooling capacity Btu/h Heat pumps-capacity at winter design outdoor conditions Latent cooling capacity Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity Btu/h DISTRIBUTION,HVAC DUCT •1 Design airflow CFM Longest supply duct: Ft Duct Materials Used(circle) Trunk Duct: Duct board,Flex,Sheet metal, External Static Pressure(ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses(CPL) IWC Total Effective Length(TEL) Ft Branch Duct: Duct board,Flex,Sheet metal, Available Static Pressure(ASP) IWC Friction Rate: IWC Lined sheet metal, Other(specify) ASP=ESP-CPL Friction Rate=(ASP■100)+TEL above,I declare the load calculation, equipment selection, and duct system design were rigorously performed based on the building plan listed • e on -se forms will be subjectto review and verification. Contractor's Printed Name Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. We AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.