Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
septic info
O O CITYof ORONO +� Ia , Municipal Offices Street Address: 95a—a49-460 O Mailing Address: 2750 Kelley Parkway P.O:-Box 66 �— Orono, MN 55356 Crystal Bay, M 55323.0066 To Current Owner: Address: Say N6 ni, S'Sf", City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. 'STEM CONFORMITY (1-3): 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prolu'bited ISTS;an ISIS located within a designated 100-year flood plain,any ISIS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): =pection indicates: pout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped 10—N-04 ). Make sure septic tanks are pumped through manhole and not through white inspection Pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated eluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. Date ofsnspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. CITXof ORONO ' NfunicipalOflices Street Address: Malting Address: SI3 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.006E 95a-44q-4600 To Current Owner: Address: 5-9 I 1V0 r+1,,. sy n m �Roq j City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1® "CODE SYSTEM"An ISIS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an Imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100 year flood plain,any ISIS which may or may not meet all the location,design.or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limitina soil characteristics. TANK CONDITION(f-:7): Tank inspection indicates: Pumpout not needed at this time. �-� Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped -1q-O® ), Male sure septic tanks are pumped through manhole and not through white Inspection pipes This allows for the proper cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CONDITION(8-10): Drainfield is dry,no surfacing evident. Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CONSIENTS: c.\ ck�� +grAl�& TOOK- OIC P.e�lsCe if\s Ct-or, Date of Inspection Matt Boltennan- Septic System ystera Inspector Note:in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer ofproperty.be advised that this report does n0tgu2r3.'+tr orcertilj that an existing system will continue to function properly,but is merely an opinion o f the adequacy o f the system under current conditions 6ised on the avail W infomtation. CITY of ORONO * 'rlNfuniclpal Offices Street Address: Mallin A 2150 KelleyParkway S ddress. y P.O. Box 66 Orono, ct 55356• Crystal Bay, MN 55323-0066 • 95d-�4q-y600 To Current Owner: Address: I No C 4, STc tq r. R� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 -CODE SYSTEM"An ISIS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Cade but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or .an Imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISIS located within a designated 100-year flood plain,any ISIS which may or may not meet all the location,design,or construction standards of tine current Orono Municipal Code and which Is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-.7): Tank inspection indicates: OPumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped O%A-O%-o O )_ Make sure set)tic tanks are pumped through manhole and not through white inspection nines This allotivs for the proper cleaninL. 7 Inspection risen missinj tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. D INFIELD CONDITION -fQ : 8 Drainfreld is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 DrainfieId is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CONSENTS: :'-Q C' Sed 3 C -Vo'c�(s OoIL O� ck 2�A —0 Date of Inspection Matt Bolterman- septic system ep y Inspector Note:In the event that this inspection report is used to satisfy threquicements for a mortgage or other transfer ofproperry,be advised that this report does not guarantee orcerd y that an existing system will continue to function proper,,but Is merely an opinion ofthe adequacy of the system undercurrent conditions 6ksed an the available information. , O O I CITY of ORONO • Municipal Offices Street Address: Mailing Address: l ri ` E+gg04' 2150 Kelley Parkway PA.Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 A July 5, 2000 Bruce& Caroline Carlson 591 North Stream Road Wayzata, Mn 55391 Dear Mr. &Mrs. Carlson: An inspection of your septic system was conducted on June 29, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year(last pumpout date 6/9/97). The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built drawing is enclosed showing the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 2494600. R pest y, s Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or othertransfer of property, be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)2494600 • Fax(952)249-4616 www ci.orono.mmus 0 . 0 0 N.N CITY of ORONO Municipal Offices G Street Address: Mallin Address: g ss. ` gg0 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: �, �Yn 1 Address: 591 North Stream Rd. Permit Vs: 9092 Dates: 7/2/87 Contractors: Quickway Ego. (This is [Y] an existing system [ ] new construction) . ` STEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [X] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) K CONDITION (5-9) : 5 5 Pumpout not needed at this time.. Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are EX or are not [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed 'to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 (11 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is93.5 feet and the system is compliant. _�L Date "of AW n p�n Sep iY s p s S stem 2 ct- . ___ '&4 -ro Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 9 FAX 473-0510 CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT INSPECTION REPORT ��kEsH0�� Owner: ELLL Cal "r,, Address: I 6? � �f�lY1'\ ''�, Permit #'s: —Dates:_ _ 2 � Contractors: 1/l�,l61�.C�ll LJI�i. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �k an existing system I ) new construction) SYSTEM CONFORMITY (1-3): "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM1'-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system Located within a designated 100-year floodplain; any system which may or may not meet all the Location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristichas or ( ) has not been identified at this time. If the limiting soil characteristic has not been identil& this classification may be subject to revision.) TANK CONDITION (5-10): Tai c inspection indicates: ��/J Pum .Pout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharlje. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (411 dia. pipe) must be installed to each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directlyover tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Denfield inspection indicates: MY Drainfietd is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs mast be completed within 90 days. 14 Drainfietd extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): COMMENTS: Date of Inspection SeFptiqf System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 Dy ON-SITE SEWAGE TREATMENT . INSPECTION REPORT ti �G 9kES 0 Owner:_ ���� 091'7 Address: / 1//JV__9 Permit #'s: Dates: /���7 Contractors:Q",- -1, Ekr. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is M an existing system [ I new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the Location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM.1-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the Location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with Less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic L has or [ ) has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 11) Pumpout not needed at this time. s cumulation m tsnks�ndicates they hould be out this ear o help pr en+ f��*urg ���hl 7 Solids ac—- c1tton to tend sat a crT e s s ou out as soon as posst . 8 System is discharging to the surface. Tanks must be pumped out within 48- ours to eliminate surface discharige. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (41, dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr field inspection indicates: Drainfield is dry, no surfacing evident. V2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): lldnc POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): COMMENTS: Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner 01124/2008 01:30 7634975011 SPTESTINGINC PAGE 02107 7 d"h ®p TESTING, INC. Steven B. Schirmers e MICA Cert.No. 627 951 Katydid Lane NE • St. Michael, MN 553F� (766 63) 497-5011 State License#394 Janauary 14, 2003 Sandy Jaeger 591 North Stream Rd. Orono, Henn. Co., MN A compliance Inspection was completed for the existing onsite sewage treatment system located on this properly. The system consists of 2-1000 gallon septic tanks &4 trenches 87' long each = 3481in.ft., 1044sq.fk, Soil boring#1 found mottled soil at elev.87.2. Soil borings Into the system found the bottom of the rock on the lowest trench at elev.90.4 which leaves a 3.2' separation from the bottom of the trench & saturated'soil. Boring #2 found no mottled soil to elev.86.0 &the bottom of the rock was found at elev. 89.0 which leaves a 3 separation from the bottom of the trench & mottled soil. This system meets the required 3' separation from the bottom of°tfe ` trenches & redox features & is classified as in compliance with Minnesota Ch 01r' 7080 rules. The tanks were pumped by Sullival Utility Service which found the tanks to be water tight. Nothing other than gray water(laundry, showers, etc.) human waste &toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended, due to adding more solids &fine solids passing through to the system. Recommend to divert iron filters out of the system, recommend to divert the water softner also,if diverting the iron filter. Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower cleaners used every shower&chlorine agents may kill the bbria needed to treat septic effluent. Additives are not recommended. Recommefid'lo pump & clean your tanks through the manhole by a certified pumper every 2 years:-?Check with your pumper to set up a schedule_ 'T'dt This Certificate of Compliance is no guarantee that this system will continue°ta unction indefinitely. Steven B. Schirmers 1 01/24/2008 01:30 7631975011 SPTESTINGINC PAGE 03/07 2/2./02 ' Water/Wastewater-I5T54.31 C6,M111.1 nce,lnspectflon (Forge for B�&Ung XC clivi %W sewage Treatment Systems l`+lino7epota Pml➢u'don =�a,s +CoIntrol Agency Comp/anon of 11718 foml fu117/1s pie Minimal mqufmments nfMhln.Stah 9 ii5.55(2001)•and Minnesota R.ch, 7080„(/999). (Tease refer to local ordlna cos for,diher re ui efndnis rarinform tion es eolall f r:oo (lance re uiremente Jor bedroom additions. General Datr+d of Inspecdton: 14.-v • (Reason foe Inspectiont - Property ownerrs) Sri\4s•4 i :Iwo i'6't A. 2 Telephone, Person regoesting•lnispection lSfAti.R�i Telephone( ) Site Address S10) 1 Citg/, Zip Code FW8 No./ parcel No. � Coln'nty.,1�Gn!)4*4 SAO Townshlp Legai Description Local itegalatoryAuthority G� �'� D� �9!-�0 Date system constructed' 9 at_3_-SS 7Syst4m in Shbreland! rams no System in illfellhead Protection,Area., yes rio System 15®rvlamcq a MPH licensed facility; yes ri1 Laft[Vermit#(if any) Sys:Wrns built prioi.to April 1, 1906 and not located in Systems'located In-Shomland{or Wellhdad.Pralection Shoreland or Wellhead Prbtectlon•Area eir Serving a'pood, Areas ur Serfing,a Food;Beverage.or•Lodging j' Beverage or Lodging bushinent' • EstabOhment,or evs!Zms Quilt afteir March 3141-996 Is the systlem an•ill mbitn9:ilhm- A do i-ublic henith mr Isthe astern.an 101iv>t�nent threat t® 601116 health safe a' ansi�ver Is ar7ITm�51� t@M � Yom' J••• dr'saifetva•(�'y�sans`warlsanl�PHssysramJ -Discharge of Sewage to tlie,gMund suArce? YES NO -DI.Sdaargo ofsewage to the ground surfage7 ),)!S_ O -Discharge df sewage to drdifitlle or surface wet=? YES Np •-pisctorgs of sewage to•draintlle or surface wattrs?Yt,s - Se back Into dwelling? ••YES NO -5ewagehadcup Into dW®Idng? ,YES -SltuaUvn WM the potantlal to Immedlat- ly and -SlUtion with the potential to immediately and adversely impact•or threaten public belalth•or adversely impact or Ali wtegn public hrraltta:or . safely? YES NO• 6fety? YFS CO) Ts • , mss oslem-falling? (a j as anspIF.a fa/Iltlgsys em) Is tte s�ste i l aL(a yes.answer'Ps`a falling system) Less thah Trot!&feet of vero al,separiltl, n be en, -Less khan•."lt�l�feel:oF•ver.tical••separallop•bei�Veeii,:,�, systhm-bottom••aha'vWrated soil ur:kt•diock? ' - •'Y�s '•NO .6m.M boltdm d6d; Wik ted sol)or bedrock? YES (l -A seepage tilt,cesspool,drywell,or-teaching pt? YES,'No -A seepage pit cesspool,drywall,or leaching Olt? ' ' YEs t N� �t to s rstern non�c� p➢iant.B �s'�ln�s9vsterla thou-ciatRe liant? :dv - ,is the s)ystom reguleted'urider a moilto'ring plan or Is ihe' _4pt9l'1'1•regulated under a.monital7ng plan or operating permit? (ff no,.go to page 2) YES NO opecsting permit?'01nv,go(a pag e•2) -YES If yes, If yes, -Was the required monitorinj token p�aoe7 YES. NO -Has the required motiltoring taken pld6il NO •lff no, the system is norp•complylgg) I (if no,Yhe•eYetem bnon'�cftplyfng) is , '•Does.tho monitorih indloate al t - 9 ha th�aysfeni inebta Doegtft manitoiing inc11c;i*thd(1hv system meat&- porf rmdtice a eotatfdhil :. I, :; ;. 'R'�., ,• � p ; , .,1�© f6txiia[�gq,epectatii ,e4 , a ate' No (If no, ;1Fi sy�fririi fd-n?n-rbralplying) (Ifnv, the system Is nun-aomplyfn91 I • ,.y, i .' .' , .„ , . ;f lis Parc 1 0f 2 . vvq-wwists4.31 "r` 01/24/2008 01:30 7634975011 SPTESTINGINC PAGE 04/07 Property owners) 5A,,a®�1 �1 - Fire No./ parcet No. stm' Cgr�nonern9!; (Please descr%be the systEem aolrlponenty dnd attach Jfte slceit*showing system/owtfon): N- eg f ' ms'. , 11_k13t rnetliod yv i sed t®irvaake-'AAjX=Irta ens fur the comnllenGS-insnectlon?(f(ote:No standa{d protocol exists: The rd1lcwing list is notehiarwtrve,orin sequential ordernor/iidfcates ivhlch combin#tlons'mayne ry to make a de4ormfiatlon) • a ' watertight tanlc(R) Hydraulic Functioning Vertical Separation Vl nce ❑ Probed tank bottom, ❑ Smirched for surface outlet 10 •Cdnducted soil borings ❑ Observed low liquid level ❑' .Perfolmed hydraulic test Deptli td limiting layer.7�-ll..fl ❑ C-vmined const. records 0 Searched ft-seeping In yard WQ Depth to system bottom cw Vze% "Wo • Examined empty(pumped)tanic ❑ Checked fbr bark-up.in home o bmnmined records 90'4 3'q' o Probed outside yank:.for"black sol]" it Excessive ponding In soil system/D-boxes ❑I L'GU UmilIng Layer Ver(ficatlon ❑ Pressure/vacuum check ❑ Homeowner testimony .• ❑ Other ❑ 01:11er— ❑ bxamined for surging In tank F.jW%V40n TM' •5'1%-%-1VA0 0 Vlaek•solj':above soil system )1d ❑ Other _.. Stitus.of the s st euro used an the compllance crll:rada,,the-system status Is. (dieck one.) ,❑failing'(to protect groundwater) ❑ an imminent threat tp pirbilc Itdaltil pr safety(ITPHS),'d nori=compllant'(moriltatirig issue) M cbrhpllant'(none of the 3, previous conditions). 'Therelfore,this•doautnent is a: M—CerUncete of Compliance CU'Notice of Noncompliance Ms this s'ysteirn•a'ti'EPA elass'1f EI1"ecllaan�lVel�7 i, D yes ® nM. o C�atific�tion. .. � . _-� • I.hereby certify as a state of Minnesota Iltensed•Inspector and/or Designer I or Quaafled Employee Inspector and/or Quallped Employee Designer I t6t I conducted an Inves#igadgn that accurately detetmWed tho compliance status or this syAw and that my recorded observations are accurate as of this date. Mo datermination.of future hydfaulic performance has been nor can be made due to unknown conditions during system cdnstmcllon,abuse of the system,InadegU2M m3lntenance,or future water usage. Inspector's name(print) 1'Gi 45(All w� Z_ Phone_ e)(a?, -- °-t"1') — oa...� Ucensc and/or Regi otlon Number Address 9�'1 �K1-'S�'��.7 eP� L-.14•. Smployed by i- Address ell', .t,L.6k Signature �' �-�.._._---^ Dale �Ps�de Reauir®[uentr,Ys ,(derlVedfinmM/nnesolastafules�,lt5.55) An 17PH5mustbe upgraded,replace vrlbruse dlscogt/nued lWln ten monthsofMZPJ,otof b5/s noffiv or w/thln'a shorterperloelf requfredbylecal ordinance rifre*%'Wn falls to ptovldpszWdwtgroundrva*pmtectlan,lien the system raiustbe-upymdo, replaced,orfir use d1=17ffn&MeWbla the pmts r&7U1>rd by Mfg or,the!oral ofdlnance, If an ed;Mgsystem/s not fallIng as defined/n law,and has atleasttwo feetofdeslyn loll separa#lon.Hien the system need nothd upgrades;mpslled,/eplaced,or/ts use dlsaontlnued notwlitisbna7ng anylota/am7nanae diatlsmore This does notapp/y 6 systems/n shornJand areas,We!/head pratectlon areas, or.diose uis�+d In sionnerlon MM f=4 beverage,and lodging estab/lsl'iments�s defined tri law, t, 5uaaes ed,,Attachmentj "Site siceLth cddld-gisd In6lude:well,Wall setback tp 5yiMrn,,dwelling orother bulldings,,,tank s),reserved soil treatment area, s7&t&ce wa(�r and•sofl'borl6g locations. Include as-bullt diawing If available. " z) Soil boring logs,'slicwing each'horizbn,`YAdlate ttig'texture,color,rMoAmorphic fealures dQpth•tn bedrock,st riding water,and wltetliq the material Is till. 3) A IiSL•of any.and all requlrertm®nts of theJecal ordinance thaL;Ire 410kaMt frim the slate requirements referred to on this form. '4) A homeowner survey of system performance,signed by the horneoWner as being factual. 5) Monitoring data as approorlate. 71 Page 2 of 2 01/24/2008 01:30 7634975011 SPTESTINGINC PAGE 05107 . w -P TES'TINGy .INC, Steven B. Schirmers • MPCA Cert.No. 627 951 Katydid Lane NE • St. Michael, MN 55376 • (763)497-3566 FAX • (763) 497-5011 State License 0394 all .Bn�31.AL%- Sandy Jaeger 591 North Stream Rd. Orono, Henn. Co., MN Borings completed on 12-14-07, with a hand bucket auger. ER-t- Elev.93.0 - MOTTLED SOIL AT 70 no standing water present-0 in boring. 0 - 16" Fill soil loam & clay loam 16" - 24" Original soil dark brown loam 10YR 3/3 24" - 28" Gray brown loam 10YR 5/2 28" - 38" Yellowish brown clay loam 10YR 5/4 38" - 62" Yellowish brown clay loam 10YR 5/6 62" - 70" Yellowish brown loam 10YR 5/6 70" - 78" Rusty dark brown loam 10YR 6/3- mottles 10YR 7/1,6/8 fit NUMBE��Elev.92.5 - NO MOTTLED SOIL PRESENT IN THE BORING. 0 - 10" Topsoil dark brown loam 10YR 313 10" - 18" Gray brown loam 10YR 5/2 18" - 42" Yellowish brown clay loam 10YR 5/4 42" - 48" Yellowish borwn sandy loam 10YR 5/6 48" - 72" Yellowish brown loamy medium sand 10YR 5/6 72°1 - 78" Light brown fine sand 10YR 6/4 01/24/2008 01:30 7634975811 SPTESTINGINO PAGE 06/07 ` . . , = ""a, 's ~ ,~~_v ___ __' 1�� Invoice i 01/24/2008 01:30 7634975011 SPTESTINGINC PAGE 07/07 G ' AIL d`p X4 ti M1 b � o Y \ 15 ' N 44 CL ss.. • / �r�E I 1 y N G I� 1 CA de .e P. N 5 ° C.0 s a N in lit a W P. n� Lk a r cVN m C G N Im �.