Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2018-00131 (mechanical- heating systems)
CITY OF ORONO 1 111 11 I I 0 1 8 - 00 I1I I I I I I I I III I� 2750 KELLEY PARKWAY DATE ISSUED: 02/07/2018 ORONO,MN 55356- (952)249-4600 FAX: (952) 249-4616 ADDRESS : 3155 CASCO CIR PIN : 20-117-23-43-0027 LEGAL DESC : SPRING PARK : LOT 038 BLOCK 000 PERMIT TYPE : MECHANICAL PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : HEATING SYSTEMS VALUATION : $ 6,000.00 NOTE: ALL TESTING REPORTS SHALL BE ON SITE AT FINAL INSPECTION. (1)TRANE HEATING SYSTEM (1)TRANE A/C UNIT APPLICANT MECHANICAL 75.00 STATE SURCHARGE MECH(VALUATION) 3.00 PRACTICAL SYSTEMS MAIL-IN FEE 2.00 4342B SHADY OAK RD HOPKINS,MN 55343 TOTAL 80.00 (952)933-1868 Payment(s) Minnesota State License#:mech-M B003 5 10 CREDIT CARD 0097 80.00 OWNER KRETSCH,KEVIN&PATRICIA 3155 CASCO CIR WAYZATA,MN 55391- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. L6Akikitd) fir I i Ail l l • Date Applicant Permitee Signature Date Issued By Sia ature Feb. 7. 2018 9: 31AM PRACTICAL SYSTEMS No. 4088 P. 2 R ETY USE ONLY City of Orono �/ 7/o!1 ‘v....0.4",, P.O.Box 66 Dale Receival• `R Permit ii / 2750 Kelley Parkway �j/� Crystal Bay,MN 55323 Approved By: Amount S: O/0't Phone(952)249-1600 Fax(952)2494616 1 E tt,t0s►l0-� CITY OF ORONO—MECRANICAL PERMIT (All Commercial permits must be approved by the building Official or Inspector and/or Eire bfanhall) GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a pennit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs—Complete calculations,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT (Check All That Apply) Residential []Commercial(Approval Required) [Backflow Device:❑AVB ❑PVB] 14New I]Additional ❑Repairs 0 Replace Job Site/Owner Information: Site Address: 3 p SC.y 1 r' Owner:16in Krei-sdr) Mailing Address: I %I5 City; Pig mbu , Zip: 554L7 Home Phone: Alternate Phone: 950~ 59i) 503 ) Contractor Information: CS I d Kane. Ct f? VBA Pra.d+t,a..l ` Contractor: tica Contact Person: V th ro'C e" Address: 3W 0130 r yi1L .+fi State Bond#: pb351 0 City: 51' letiNs Pukz.p95AgfExpiration Date: 9/1-7))8 Phone: -'i5131 V(4,5' Alternate Phone: ❑ Insurance--Current: l_4 e.5 1 Feb. 7, 2018 9: 31AM PRACTICAL SYSTEMS No, 4088 P. 3 -`5i4 Note:All Geothermal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? ❑Yes PINo HEATING SYSTEMS Quantity: Make: Model: 5a1VA15o4C1 — pSpcA Fuel: 1l1 Flue Size: Input BTUs: Lk, OtZ Output BTUs: 3 ,ti00 _ CFM: COOLING SYSTEMS Quantity: Make: TrQ{ 1 — Model: 411X6301gi 1 OW Tons: 1. 5 H.Power FIREPLACES ❑ Gas Factory Fireplace Brand Name: [] Wood Burning Fireplace ❑ Wood Stove Model No.: ❑ Wood Stove with Flue/Masonry VENTILATION ❑. No. Kitchen Exhaust duct recirculating cfin ❑ No. Bath Exhaust(must have duct outside) cfin ❑ No. Other Fans: Locations cfin FUEL STORAGE (Mat be approved by Fire Marshall if proposing to abandon lank in place.) ❑ Installation ❑ Removal Fuel Oil: gallons 0 Underground 0 Inside ❑Outside LP Gas: gallons Other: GAS LINE ONLY O Outdoor Grill ❑ Other/List What&Where: 2 Feb. 7. 2018 9: 31AM PRACTICAL SYSTEMS No. 4088 F. 4 1. CONTRACT PRICE *is 1.25%of contract price with a(Minimum Fee�otf$50.00) tUOQ. Ctt x.0125$ I S•bp (contract price) (minimum S50,00) 2. STATE SURCHARGE (ab x 0005 $ . 3.QO (contract pnce) 3. POSTAGE&HANDLING(Only on Mail-In Applications) S 2.00 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ '(Da ■ * CONTRACT PRICE or JOE COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done. If any material,equipment,labor or installations are furnished by the owner, tenant or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. r i v o i . . G ?�E� �t_ 8�����t; P����1 1 ,''NroAr_�__�!:J�`AO,��.�}�tii'�'h�„�.`.��'�—� The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota,and certifies that all statements made on this application are complete,true and correct, Applicant's Signature: '..+ -lid„A, eil.f.thfJ1 nate. 1 1 15 3 V. \\_Th, .v\\ DATE TIME CITY OF ORONO CALLED IN �,/ INSPECTION NOTICE SCHEDULED 02-07 -/2r /OV PERMIT NO.G20/ ' 00 fp �j COMPLETED ADDRESS 3/53- 1..i r OWNER TELEPHONE NO –? 7 ; C —I CONTRACTOR f ziCY'._ - - c ��> DESCRIPTION j/� /1— lu LU ❑ FOOTING ❑ DEMO-FINAL 0 SEPTIC FINAL ❑ Q POURED WALL 0 PLUMBING RI ❑ EXCAV/GRADING/FILLING ❑ FOUNDATION DRAIN TILE ❑ PLUMBING FINAL ❑ TREE REMOVAL CI Z ❑ LATHE iiitZECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL 0 RATED WALLS • ❑ INSULATION ❑ WOOD BURNER/FIREPLACE 0 COMPLAINT Q 0 FINAL ❑ WATER HOOK-UP 0 FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL v ❑ DEMO-SITE ❑ SEPTIC INSTALL Q OWNER/CONTRACTOR TO MEET YOU: YES NO <--- % 2 COMMENTS: Co",e•� 7d /foes - YaK e 14'7 Fv ct y a / 3 L, . N.. — 5u l'r's ✓',e,�w,•�s - d X - ,6444 4•1s -0K 4. - k '�• , a - a A' are' Se4it.!), 4,est✓eseeb ftc-tecka) CC _ / art Vwb G , . 4,✓ elerraricd✓ycv a at - Cgs-A,&iacifa W 0 WORK SATISFACTORY:PROC D % 0 PROJECT COMPLETE � $Fitei3fiWORK 8 PROCEE p 4'UV 103 'G ❑ ISSUE CERTIFICATE OF OCCUPANCY O CI CORRECT WORK,CALL FOR INSP .st imi.i TEMPORARY OU BEFORE COVERING 641 49 C/,'t $ti—PERMANENT LI CORRECT UNSAFE CONDITION WITHIN HOURS. j PHOTO TAKEN INSPECTOR WILL RETURN O STOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: c Inspector / i•-•°' White Copy/Inspector's File Canary Copy/Site Notice • E Certificate of Completion Dud Sealing Performed For 350 Kretsch, M'Ahs 3155 Casco Cirde \\........... Orono, MV 55391 300 250 Overall Sealing Results 200 U When vte arrived, YOUR DUCTS HAD: 27 150 • 337.1 CFM of Leakage, equivalent to a LI 100 63.7 Square Inch Hole This equals XV 3tefric, -etas full ofair loss every ha,: 50 After we finished, YOUR DUCTS HAVE: 0 26.7 CFM of 0 5 10 15 20 25 Leakage, equivalent to a Sealing Time in Minutes 5.0 Square Inch Hole This corresponds to a 92.1%Reduction in Technician Mark D Duct Leakage. Aeroseal Case ID 4178 Date of Seal 2/26/2018 Note: Duct Leakage results are calculated in Cubic Feet per Mnute(CFM) measured at a standard System Description Kretsch House OPERATING PRESSURE of 25 Pa. Seal Description Main St.pply Hardware Hor neSeal AERDSEAL® Dud Sealing Performed By: IDuct Sealing From The Inside Practical Systerrs 3230 Gorham Ave St. Louis Park, MV 55426 Phone: 952-933-1868 X Certificate of Completion Duct Sealing Performed For: 500 Kretsch, Mr Mrs 3155 Casco Cirde Orono, MV 55391 400 Overall Sealing Results 300 a Wien we arrived, U YOUR DUCTS HAD: y 200 400.3 CFM of Leakage, equivalent to a 75.6 Square Inch Hole 100 This ag,caIs 240.2 ie Ggerators full ofalrloss every hr After we finished, YOUR DUCTS HAVE: 0 5 10 15 20 25 29.6 CFM of Leakage, equivalent to a Sealing Time in Minutes 5.6 Square Inch Hole This corresponds to a 92.6%Reduction in Mrs Technician Mark D Duct Leakage. Aeroseal Case IC 4178 Date of Seal 2/26/2018 Note: Duct Leakage results are calculated in Cubic System Description Kretsch House Feet per Minute(CFM) measured at a standard OPERATING PRESSURE of 25 Pa. Seal Description Basement apply Hardware HorreSeal AEROSEAL® Dud Sealing Performed By: [Duct Sealing From The Inside Practical Systems x.-. 3230 Gorham Ave St. Louis Park, MN 55426 Phone: 952-933-1868 Certificate of Completion Duct Sealing Performed For. 300 Kretsch, Mn-Mrs 3155 Casco Circle Orono, IV1V 55391 250 .2 .201] Overall Sealing Results N When vte arrived, 150 U YOUR DUCTS HAD: 283.0 CFM of Leakage, equivalent to a " 100 53.5 Square Inch Hole This equals 16?98refrigerators full of air loss every hou: 50 After we finished, YOUR DUCTS HAVE 0 D 5 10 15 20 25 31.1 CFM of Leakage, equivalent to a Baling Time in Minutes 5.9 Square Inch Hole This corresponds to a 89.0%Reduction in Aeroseal Technician Mark D Duct Leakage. Aeroseal Case 1 C 4178 Date of Seal 2/26/2018 Note: Duct Leakage results are calculated in Cubic System Description Kretsch House Feet per Minute(CFM) measured at a standard OPERATING PRESSURE of 25 Pa. Seal Description Main Basement Return Har iv ere HomeSeal A L R J SEAL. Duct Sealing Performed By: [Duct Sealing From The Inside Practical Systems 3230 Gorham Ave —41411111011116*. St. Louis Park, MN 55426 Phone: 952-933-1868 Certificate of Completion Duct Sealing Performed For: 800 Kretsch, Mr Mrs 3155 Casco Cirde Orono, MN 55391 600 C- Overall Sealing Results 0 When we arrived, �0U YOUR DUCTS HAD: 758.9 CFM of Leakage, equivalent to a 143.4 Square Inch Hole 200 This equals 455..3refngeatas full of air lass every hour After we finished, YOUR DUCTS HAVE: C' G 5 10 15 20 25 23.3 CFM of Leakage, equivalent to a Sealing Time in Minutes 4.4 Square Inch Hole This corresponds to a 96.9%Reduction in Aercseal Technician Mark D Duct Leakage. Aeroseal Case IC 4178 Date of Seal 2/23/2018 Note: Duct Leakage results are calculated in Cubic System Description Kretsch House Feet per Minute(CFM) measured at a standard OPERATING PRESSURE of 25 Pa. Seal Description upstairs Supply Hardware HomeSeal A EROSEAL® Duct Sealing Performed By: (Duct Sealing From The Inside Practical Systems —4441111111111.1." , 3230 Gorham Ave St. Louis Park, MN 55426 Phone: 952-933-1868 SmartSeal(4.2.1.41)CaselD 4178 Residential-[Smart Seal] PI File View Just the Facts Maintenance Help Wireless Cretsch residence at 3155 Casco Circle System Sealing Event Sealing Process 0:20:37 The system is idle. 800 I Click[Start] or press [F2]to start sealing. Click[Next] or press [F9]to go to the postseal test screer 600 • c' 406 200 v11, 0 1 2 66V 1 10 09V 5 10 15 20 25 30 12 62V Se0 24 . 4.5 Time in Minutes o oiDA 3 36V 3 36V 4.5 Duct Leakage(Square Inches) I 64.9 Inlet Temp(°F) -Heaters _ 19°C 20°C 24 Duct Leakage(CFM ©Operating Pressure) I 141.5 Wand Temp(°F) E1.68 v 00% ! 2.0 Duct Leakage(%Sys CFM) I 102.1 Cylinder Temp(°F) 143 Duct Flow(Fan CFM) I 44.2% Inlet Humidity(%) Sealing Elapsed 10:20:37 500.1 Duct Pressure(Pa) SealantWater Pump I -15.2 Fanbox Pressure(Pa) Fluid Left OFF Hr:Min Fluid Level *11011111.11111 T Fan Pump Setting I OFF CUM J 58._0 sealing - Help 1 ! Inlet Gate livj Number of Fin:. 11 ij Best Setting I ON V I 4.63 EMS '.1,,1, 111-:,; I Fan Speed 11,D507: Auto Control Slower I Faster 1 1111111111111111 Seal 'Start r -17 C fp 64 11!DS AM p,-; 0:1) _- , ' 2/23t2018 Lic Certificate of Completion Dud Sealing Performed For: 250 Kretsch, Nir Mrs 3155 Casco Circle Orono, MN 55391 200 , Overall Sealing Results N 150 a Wien we arrived, YOUR DUCTS HAD: 100 239.6 CFM of Leakage, equivalent to a 45.3 Square Inch Hole 50 77rs ecuals 1438 n3frigeratas fill of air loss ewry/xrr. After we finished, YOUR DUCTS HAVE: 0 0 5 10 15 20 25 28.9 CFM of Leakage, equivalent to a Scaling Time it Miracs 5.5 Square Inch Hole This corresponds to a 87.9%Reduction in Aercseal Technician Mark D Duct Leakage. Perused Cagf.ID 4178 Date of Seal 2/23/2018 Note: Duct Leakage results are calculated in Cubic System Description KnAsch House Feet per Mnute(CFM) measured at a standard OPERATING PRESSURE of 25 Pa. Seal Description Upstairs Return Hardware HomeSeal A ERIJSEAL. Dud Sealing Performed By: (Duct Sealing From The Inside Practical Systems 3230 Gorham Ave St. Louis Park, MN 55426 Phone: 952-933-1868 SmartSeal(9.?_.1.41)CaseID 41/8 Residential-[Smart Seal] Mai • File View Just the Facts Maintenance Help Wireless Gretsch residence at 3155 Casco Circle ircl System retsch base Seams U stairs tl rn Sealing Process $4 Clem is idle. r. hin 250 Cart]or pressf � art flusg. IP'''. %T :' prs to the postseal test sn12 200 o 100 0 _..........................._. _, LT_ 50 o G, V(m}:. c , r 12 83V 5 10 15 2C 25 30 j 1p46v ctt4 SealingTimeir Mirt.tes t p( V # 33W 3 38V 51 Duct Leakage(Squat`s Inches } 65.9 Inlet Temp(°F) Heaters. . 2, � 27 Duct Leakage(CFM Operating Pressure) I 185.# 4VandTemp 1.98 �; 2.3 Duct Leakage(%Sys` FM) 105.5 Cylinder Temp °F) 156 Duct Flow(Fan CFM$, 37.3% Inlet Humidity(%) � .SIIIIIIIIIIIIIIIIIII eakng lad ,r-- 5 :18:46 464.4 Duct Pressure(Pa) Sealar)tl4 tel' -18.2 Fanbox Pressure(Pa) Fluid Wit) Hr..Min Fluid Level F r Fan Pump Setting oFF CC/M � 58.0 + Number of Fans 1 tt BeSt Setting` OW V 4.63 flushing Help Inlet Gate J StartjF2] Pa;-use {stop[F3]� Fan Speed 100° Auto Control Slower Faster } MEI iiii, I gINI s..l MEM ,,v5;teett ..('‘,.'s7-7 ,i