About
2017-01610 - new structure
CITY OF ORONO III I I I III * IIIIII * 2750 KELLEY PARKWAY DATE ISSUED: 01/19/2018 ORONO,MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS : 765 LAKEVIEW PKWY PIN : 06-117-23-34-0010 LEGAL DESC : LAKEVIEW OF ORONO : LOT 1 BLOCK 2 PERMIT TYPE : NEW STRUCTURE PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : SINGLE FAMILY ACTIVITY : 101-SINGLE FAMILY HOUSES,DETACHED VALUATION : $ 529,000.00 NOTE: SEPARATE PERMITS REQUIRED:PLUMBING,MECHANICAL,SEPTIC,FIREPLACE, WELL(STATE),ELECTRICAL(STATE) NOTE:PLEASE SEE AND INITIAL NEW BUILDER ACKNOWLEDGEMENT FORM NOTE: SOILS VERIFICATION WILL BE REQUIRED BEFORE SEPTIC MOUND CAN BE INSTALLED. INITIAL: N APPLICANT PERMIT FEE SCHEDULE 3,782.17 PLAN REVIEW 692.74 YEA HOMES STATE SURCHARGE(VALUATION) 264.50 1000 BOONE BOONE AVE N#400 GOLDEN VALLEY,MN 55427- TOTAL 4,739.41 (612)741-9069 Payment(s) Minnesota State License#: BUIL-2459 CHECK 16959 4,739.41 OWNER Gonyea Homes 1000 BOONE AVE N GOLDEN VALLEY,MN 55427- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested ip conformance with the State Building Code.Th. rmit may be revoked at any time f due cause. / / Applicant Perm ee Signature Date Issued By Signature Date Builder Acknowledgement Form Permit #2017-01610 / 765 Lakeview Parkway Builder Representative Name: M. ' n. \-)\--- Permit Conditions: Initials **NOTE CHANGE** Before scheduling an exterior insulation and/or drain tile inspection, a foundation as-built survey must be submitted and approved by the City or a Stop Work order will be issued. Schedule a minimum of one hour for the framing inspection. M Erosion control mechanisms must be installed and inspected by the City prior to any land disturbing activities. The contractor must provide a minimum of a 24 hour notice prior to n( J\ inspection. • \ Erosion control shall be installed and maintained throughout the entire project and must A' remain until vegetation has been established. " A haul route shall be submitted to the City Engineer for approval and inspection prior to commencement of hauling from the site.The property owner shall be responsible for cleaning N ,f'v and repair of roadways for any adverse impacts. Soils verification will be required before septic mound can be installed. n I� No underground sewer within 20 feet of well. Prior to the issuance of a Certificate of Occupancy an as-built survey and hardcover calculations must be submitted and approved. N'- In the event of winter or other extended unfavorable weather conditions(which prevent the completion of the exterior improvements and/or as-built survey) a Temporary Certificate of f\//‘#\Occupancy(TCO) may be necessary. A TCO requires a $10,000 escrow. Advisory Comments Any changes to the exterior/landscaping improvements, i.e. patios,grading, sidewalks, retaining walls, etc. not currently shown on the approved survey and landscaping plan will require a separate Zoning Permit application to be submitted and approved prior to the work commencing. Any retaining walls that are over 4-feet in height or tiered walls not separated by twice of the height of the lower wall require engineered plans and a building permit to be submitted and approved prior to construction. w:\street files\lakeview parkway\765\builder acknowledgement form 2017-01610.docx . City of Orono Building Permit Application , 1 for New Structures or Additions 73 I' �� Mailing Address: Permit number: �J/7 - 0/(a/0 sLQAr PO Box 66 W Crystal Bay, MN 55323-0066 _�/t , Date received: /e-8'17 Street Address:' /�J`,'\�- Received by: t 2750 Kelley Parkway S elan review fee: $ / 7( S (G7 '�ESHo� Main: on 249-46006 \�'\,w tJ a0/17" c,/10129 Total Fe Fax: 952-249-4616 www.ci.orono.mnis p /`]-(J/(p// L`SCrvyt/ This application form must be completed in full and all required information must be submitted. Incomplete applications will be returned. (Please print) GENERAL INFORMATION: Job Site Address: 36 s 1, -e.ev.., r(\tzkw' , Will this be a Parade of Homes, Remodelers Showcase Home or other Display Home? ❑ Yes ❑ No If yes, a special event permit is required with Police Department and City Council approval 60 days prior to the event. Shuttle bus service will be required unless applicant demonstrates sufficient on-site parking is available. Non-permitted events will not be allowed. CONTRACTOR/APPLICANT INFORMATION: Name: (s*A,,.1 t A I4M State License# l ( 002,4S1 Expiration Date: , Phone: (cell) I Z 146 6 0 4 (office) '}z 5 i 37 45 a Mailing Address: t POO 8Pditif Jerve 1J.J City: S ZIP: 'c'`t 7.7 Contact Person: /vim � i rt_1�� Applicant is: Co rac r / Homeowner (Circle One) Email and/or Fax: tU M 1 dt i:1� CSG ut E A- ,,y1 is C6 ty PROPERTY OWNER INFORMATION: Name: o N`.1 CA, 4.„,14. n Phone (day): 5e: ,jRcvc J 5 n Address: City: ZIP: Email and/or Fax ARC IIECT/ENGINEER INFORMATION: Name. �"? t.'ki y t.4 l t^. Phone (day): S 4y,it IWO Yf Address: City: ZIP: Email and/or Fax: ARCHITECT I ENINER INFORMATION: Name: �`�� nI- ASeLlATI Phone (day): CC 1 6 fvOl 41 r-- -÷-z I Address: 'i- -3 1\11Lui > r—D 104t'- City: t*t&At%) ZIP: SC -- Email and/or Fax: PROJECT INFORMATION: Description of project: 1.Type of Project 2. Proposed Use 3. Structure Type 4. Sewage Disposal& Water Supply Ri New Construction 2 Single Family with 0 Accessory Bldg./Garage Addition attached garage 0 Deck Building ❑ Public Sewer ❑Accessory 0Single Family with 0Office/Commercial ❑ Relocation detached garage 0 Residence E Septic ❑ Other: (specify) 0 Multiple Family/Condo 0 Retaining Wall(s) (Compliance certificate 0 Public 4-feet or greater may be required) `*Any earth movement may require 0 Commercial 0 Storage MCWD review&permits. 0 Industrial 0 Warehouse 0 Public Water Minnehaha Creek Watershed District(MCWD) 0 Other: (specify) 0 Other(specify) 15320 Minnetonka Blvd;Minnetonka,MN 55345 r3 Private Well Phone: 952-471-0590 / Fax: 952-471-0682 www.minnehahacreek.orq Estimated Construction Valuation (excluding land) $ 35c. co 0 Packet Last Updated: January 2016 Page 21 STRUCTURE INFORMATION: 1. Structure Dimensions 1. Structure Dimensions(continued) a. Length (ft.)= ,S b Number of bedrooms= 2. Occupancy: ." ( b.Width(ft.)= Number of garage stalls: 3. Occupant Load: Areas in square feet Attached = S c. Basement= IIT) Detached= 4. Type of Construcion: � d. 1st Story = I 1- e. e.2nd Story= (f••;C 5. Code Edition: =—tel )� f. 'Y Story = g.Total Area= 4 D i- REQUIRED SUBMITTALS: All of the information must be submitted in order for your application to be processed: Not Enclosed Applicable ❑ 0 Building Permit Escrow Agreement and Fees ❑ ❑ Plan Review Fee ❑ 0 Completed Application Form ❑ 0 Proposed Building Plans—2 full size sets,to scale and 1 reduced 11 x 17 or 81/2 x 11 set ❑ ❑ Minnesota State Energy Code Calculations and Mechanical Code Requirements ❑ 0 Survey—2 full size,to scale(meeting ALL survey requirements) ❑ 0 Hardcover Calculations ❑ 0 Septic System Certification ❑ 0 Minnehaha Creek Watershed District(MCWD)Permit or Documentation from MCWD stating no permit is required ❑ 0 Landscape Walls and/or Retaining Wall Plans ❑ 0 Landscape Plan ❑ 0 Stormwater Pollution Prevention Plan(SWPPP) ❑ 0 Access Permit ❑ 0 Data Privacy Advisory Form APPLICANT/OWNER ACKNOWLEDGEMENT: • Agrees to provide all information required or requested by the Building Department; • Agrees to pay the City of Orono for engineering consultant review costs in excess of$500; • Certifies that the information supplied is true and correct to the best of his/her knowledge. The applicant recognizes that they are solely responsible for submitting a complete application being aware that upon failure to do so,the staff has no alternative but to reject it until it is complete; • Acknowledges the Escrow Agreement is completed and signed; • Understands some or all of the information that you are asked to provide on this application is classified by State law as either private or confidential. Private data is information which generally cannot be given to the public but can be given to the subject of the data. Confidential data is information which generally cannot be given to either the public or the subject of the data. Our purpose and intended use of this information is to annually update our records and records of other governmental agencies required by law. If you refuse to supply the information,the application may not be issued. • Agrees that in the event that weather or other conditions prevent the completion of an as-built survey at the time the Certificate of Occupancy is requested, a temporary Certificate of Occupancy may be issued upon receipt of a$10,000 escrow to ensure completion of the as-built survey and all site improvements. Applicant's Signature: �� Date: J ' Owner's Signature: � Date: / Packet Last Updated: January 2016 Page 22 PLAN REVIEW CHECKLIST FOR NEW STRUCTURES / ADDITIONS-7 Address: I LaKeVV4H' PaltWa ( Permit No.: 201-7 - Ot WO Description of work: NQ,tn1 Safi limit ( l^1 -) Date Rec'd: IL-'10-1 7 Septic review by: % ge Date Approved: 1/ ..-7//19. Zoning review by: 1 f Date Approved: ( I • 17 ' l 0 Building review by: C/ /vJ - %'`� Date Approved: 1/ 1/ (J `;- �. +lP Grading review by: I iJ1m Goadtilpf41 Date Approved: 12-1(17 Zoning District: 0.--lB Zoning File#: Resolution? Yes Reso#: Reso Date: Signed: Yes No Resolution / NA Zoning: Lot Area: 101 !qui 0 AC Width: Structural Coverage: l A SF % Survey Submitted: es ❑ No Date of Survey: t L Y 'l 1 Revised date('?): Landscape plan submitted? ❑ Yes Landscaper: 44 b4(/i QIV1.- ❑ No/ None proposed Proposed Setbacks: t Front(L e) Rear(Str t) ( N S Lt.)W ) ( N S E ) Other Buildings Wetland- Side Side (ice, Jj p. eµw 14(0' 1 (.9 ' 1ECo ' 12-7 ' 32.cp Noe-. Building Height Analysis: Distance Between First Floor and defined Top of Roof* (See "building height" (a) 25.definition): First Floor Elevation (from building plans): (b) Q 52.4 Highest Existing ground level (per survey) or 10' above lowest ground level, (c) WOO whichever is lower: 77 DD Difference between (b) and (c)*: (d) '4 Lf. DEFINED HEIGHT If (e) -1q If highest existing adjacent grade is below FFE-Height is(a) + Average Lakeshore Setback Shoreland District MCWD Permit BluffMet? Yes ❑ No Permit Number: ❑ Yes ❑ No I/A ❑ Yes ❑ N/A-see attached / Setback: Stormwater Quality Existing Proposed A. Overlay District Tier Hardcover Hardcover Variance Required CUP Required (circle one) (% and sf) (% and sf) S f ❑ Yeso ❑ Yes "No 1 @ 3 4 5 (0.350ta Type(s): Type(s): Updated: June 2017 z:\forms\plan review checklist 06-2017.docx Fees to be Charged ` . . • •` :YES- .. •NO Petnigxk V im§ qti^'*��. , Plan Review '° C . Investigation Fee Other(specify) 1.---' Square Footage $ per Square Footage /�,, Basement i- cr-/Ci. //_`c9f— O/ X /O 77 = $ Lei � � etto ,v,„-7 , , ,,,, 4‘,,, / 0 q X 7. (1-- -, = _$ i . 78) 52nd Floor )171-18 `t1" 7/ 6-6-- X /0 j,q7, = $ Z- 81. 7--,, f60 Garage 4,0( /02,54 't 3', 7'4 - $ `'0 If-2(P- Estimated Construction Value: $ v 9 00 ' Orono Inspections Required Work Requiring Separate Permits Footing 0 Site Plumbing 0 Grading/Filling 1- Poured Wall 0 Silt Fence/Erosion Control 4 Mechanical 0 Fire A Foundation Survey 0 Hardcover Removal / Fireplace 0 Water Connection 0 Framing 0 Other(specify) 0 Masonry 0 Sewer Connection s,01. Waterproofing/Drain tile DMfg. 0 Lawn Irrigation .cl Foundation Waterproofing 0 Other(specify) 0 Landscaping . .. X Framing 0 Septic Insulation As-Built Survey Final j2rLathe Required State Permits 0 Other(specify) 22(Well X Electrical REMARKS (in-house): OFFICIAL REMARKS -TO BE NOTED ON PERMIT AND INITIALLED: ee Builder Acknowledgement Form 0O Prior to release of escrow mon y an as-built survey and hardcover calculations must be submitted and approved. SO/& v' /'/Sr-- cei-dmr tX,,-. /( S ie • ui 4e,ci, he7C. /e SPS T c Uicv can ,4,.,2 r v 5 S (l ,/ Updated: June 2017 z:\forms\plan review checklist 06-2017.docx Jon Connolly From: Melanie Curtis <MCurtis@ci.orono.mn.us> Sent: Wednesday, August 23, 2017 12:44 PM To: 'Bryan Volt' Subject: height 5,4E(c,.1 -- 7 Le 5 L AA1L v%E ?"9....te,viiirl Current numbers inserted in Red. Building Height Analysis: Distance Between First Floor and defined Top of Roof* (See"building height" definition): (a) 2.5./9 First Floor Elevation (from building plans): (b) gs2.4-- Highest Existing ground level (per survey)or 10'above lowest ground level,whichever (c) 48 is lower: 1 Difference between(b)and (c)*: (d) .4— DEFINED HEIGHT *If highest existing adjacent grade is above FFE-Height is(a)-(d): (e) 30.0 *If highest existing adjacent grade is below FFE-Height is(a)+(d) Definition: Building height means the vertical distance between the highest existing ground level or ten feet above the lowest ground level, whichever is lower, and the top of the cornice of a flat roof, or the deck line of a mansard roof, or the uppermost point on a round or other arch-type roof, or the median height of the highest gable of a pitched or hipped roof. Topographic changes which elevate the adjoining ground level above the existing terrain shall not be considered in determining building height. For a pitched or hipped roof situation, regardless whether the highest living space in a building is a half-story or full story, if the highest living space contains windows (excluding skylights) the upper measuring point for defining building height shall be the median height of the top of the highest window and the highest peak of the roof. Melanie Curtis, Planner Direct 952.249.4627 Planning &Zoning Office 952.249.4620 2750 Kelley Parkway, Orono, MN 55356 Email: mcurtisci.orono.mn.us Website: www.ci.orono.mn.us SUMMER HOURS (May 22 through Labor Day) Monday through Thursday 7:30 AM to 5 PM; Fridays 7:30 to 11:30 AM 1 City of Orono „cAtcr,); , Hardcover Calculation Worksheet V/6- Property Address: 765 Lakeview Parkway,Orono,MN,55391 '�krstio‘. - Prepared By: Sathre-Bergquist Date: 11/8/2017 SB Job Number: 31202-432 Prepared By: BRV Stormwater Quality Overlay District Tier:(Circle One) Tier 1 Tier 2 Ti Tier 4 Tier 5 Step 1:PROPOSED HARDCOVER In the following table,identify all items of proposed hardcover on the property,keyed by letter to Certificate of Survey(survey must accompany this form).Include all existing hardcover items that are intended to remain,as well as all proposed hardcover items that will be added. Use as many lines as necessary to accurately depict proposed hardcover status of the property.For Tier 1 properties,identify any features by letter which are split at the 75'setback line and calculate hardcover square footage separately for each portion. Key to Survey Hardcover Item(Describe) Length x Width Total(Square Feet) (Example) (Garage) (24'x 30') (720 S.F.) A House Misc. 2934 S.F. B Stoop Misc. 178 S.F. C Sidewalk Misc. 52 S.F. D Driveway Misc. 3238 S.F. E Deck Misc. 342 S.F. F Brick Patio Misc. 114 S.F. G S.F. H S.F. I S.F. J S.F. K S.F. L S.F. M S.F. N S.F. O S.F. P S.F. Q S.F. R S.F. S S.F. T S.F. U S.F. ✓ S.F. W S.F. X S.F. Y S.F. Z S.F. (1)Total Proposed Hardcover 6858 S.F. Excludable Hardcover(See City Code Sec 78-1684): S.F. S.F. S.F. S.F. S.F. (2)Total Excludable Hardcover 0 S.F. (3)Net Proposed Hardcover[Subtract line(2)from line(1)] 6858 S.F. (4)Total Lot Area 107,929 S.F. Proposed Hardcover Percentage[(3)+(4)] 6.35% % This is an information packet regarding Hardcover.Every effort has been made to insure the accuracy of the information contrained herein;however,if any information is not consistent with City Code,the Code provisions will prevail. City of Orono �nNp Hardcover Calculation Worksheet Property Address: 765 Lakeview Parkway,Orono,Minnesota,55364 oaf"jO�t'`\ Prepared By: Sathre-Bergquist Date: 11/8/2017 SB Job Number: 31202-432 Prepared by: BRV Stormwater Quality Overlay District Tier:(Circle One) Tier 1 Tier 2 Tier 3 Tier 4 Tier 5 Step 1:EXISTING HARDCOVER In the following table,identify all items of existing hardcover on the property,keyed by letter to Certificate of Survey(survey must accompany this form).Use as many lines as necessary to accurately depict existing hardcover status of the property.For Tier 1 properties,Identify any features by letter which are split at the 75'setback line and calculate hardcover square footage separately for each portion. Key to Survey Hardcover Item(Describe) Length x Width Total(Square Feet) (Example) (24'x 30') (720 S.F.) A S.F. B S.F. C S.F. D S.F. E S.F. F S.F. S.F. H S.F. S.F. S.F. K S.F. L S.F. M S.F. N S.F. O S.F. P S.F. Q S.F. R S.F. S cr T S.F. U S.F. _ ✓ S.F. W S.F. _ X S.F. y S.F. Z S.F. (1)Total Existing Hardcover 0 S.F. Excludable Hardcover(See City Code Sec 78-1684): S.F. S.F. S.F. S.F. S.F. (2)Total Excludable Hardcover 0 S.F. (3)Net Existing Hardcover(Subtract line(2)from line(1)] 0 S.F. (4)Total Lot Area 107,929 S.F. Existing Hardcover Percentage[(3)+(4)] 0.00% % (Proposed Hardcover next page) This is an information packet regarding Hardcover.Every effort has been made to insure the accuracy of the information con trained herein;however,if any information is not consistent with City Code,the Code provisions will prevail. Christine Mattson From: Adam Edwards Sent: Monday, December 18, 2017 8:03 AM To: Christine Mattson Cc: Roger Peitso Subject: RE: 765 Lakeview Parkway/#2017-01610 Chris, I've reviewed the subject Grading Plan and stamped it approved. 1. Perimeter sediment control measures should be installed by the Contractor and inspected by the City prior to any work, including demolition. Contractor must provide minimum 24 hour notice prior to inspection. Adam From: Christine Mattson Sent:Thursday, December 14, 2017 11:14 AM To:Adam Edwards<aedwards@ci.orono.mn.us> Cc: Roger Peitso<rpeitso@ci.orono.mn.us> Subject:765 Lakeview Parkway/#2017-01610 Adam, We received a building permit application for a new single family home. My comments are: • Survey shows stairs from deck, but building plans do not. • Building plans show a 'future' porch. Need to ask for clarification. • MCWD permit • Landscape plan Please review and provide comments. Thank you! Christine Mattson Planning Assistant City of Orono 2750 Kelley Parkway I Orono I MN 155356 (physical address) PO Box 66 ( Crystal Bay MN 55323-0066 (mailing address) 9? 952.249.4620 8 952.249.4616 f9 cmattson@ci.orono.mn.us ! www.ci.orono.mn.us Office Hours: Monday- Friday 8 am to 4:30 pm OUR OFFICE WILL BE CLOSED: Friday, December 22, 2017 Monday, December 25,2017 Monday,January 1,2018 Monday,January, 15, 2018 1 76 LW-Q' '' -- Su rml *06 JfcCuc, M MrbMo d ah--I- - IpuPOral- novo 0V _Q. is flittfrui, — W'L'!D .xis � -- C'l G ' .r -- i -r!er, ctre_q, / ./� 7 -�z f / 16 (.. Svc % L Ir -C Nal itao cm to i p? -- Nhk- cjoltvc 11)1 Ve. tyu ty2,aatlak_.A1,, 2e.a tL c&QJ °f- silo :.YOY - sut 2 m in r) c‘i H 0 I 0 0 0 N CJ 00 I O N • • I U I H HHH (Y O d' O H I N •• N I" n W0 C U O o II H 4J •R U pipsolli co : N ,Q H U Q, .. =AO ox H o 1-1 W ro U 0 H I I Qw i „ 0 •a U U (J) U u. •• w w . •R N tn O Tk< # +JSa U U) z 0 U I . W E1 40101/. a b0- 1 0- 3 m ci Ll Q 0 Ll # x N a) W W W W W y >G U) U) N (I) U) V CO LL Q, Q, QI Q, x Lt N 0 0 0 0 0 I� H N 0 0 0 0 0 y` "l 021 O O o Lo in CC' asHN h d H0 i- H .. W .. z ' X . WWx > ro m w x a E1 U •,-1 U •R ) I- A Wd� N a 0 a n U) Ql a H _ x c W z UUUU ft 14410 E1 E1 a 0.1 4 ?< .c ((1) 0 0 E1 r7c � x 4J X J NJ x A o_c, jr W� 1 d x I!! 0(11 U- I III X CO III III III 111 11' x >< OA °, Y?1 ).< d0- x Hd I g c) 1-1 x •>••C 1 x _ 1 Z H u X W Z ?< _ U Z Z a 0 w g Z ,, wXu0 Z 0 Cf) a i 0 vi (/j W ti b CL W r J zm X op Zn app w YO °( QZ .. A Qm 1J 1 V2 1 ZW m 1--2¢ �W ~ ��� -. _ W 1=(I) t° UjY Q� SOU OmZ� W VUi� cim¢�c o XU u)C) U(n d,w �_,ow Q 11`a- °=Jww t2Ami 5 1 � ~ W Q w D- OJ > JW O cnp /�/ / Z Q ! iii H Wu) 2 CeH JW ZQ° H�Z� (3 �3¢ ; 0 ♦ W U I-D U ILW QJ Q>I- C0W6 Z =�z ' z O ,Y Z QW UO ccO� OHO �a��o t n h� J W W Q O n. Z J Q >,,`-Ei_q "` �,' ' m ZOZ W =J U(nQ 2Q�i 2H ¢Z ��. Q>ZY� 5 m:ci... � y 4 0-Z LL HQ WtnU �Zp (AZU- \� CoQ-.-,o d C o ww W< Z 0cEO °ro pOz_W \�� ,c5,0 -.-,° .,_ , W U Z fn z i-J U LL Y Awes,.- ��y ~ u) 0 p (n W 0 , (=j , Q„U .c° wmz .111.J Q /,�`\` 0.,„ L1p/ Z III Q COJ(n Q �> pQ Uw =H>m Aa /�� �W�NE cxl U D Z w r~m I- L7 � a�fJ Z ~ C� W co 0 Z 0 Z O W Z W r 2 t Z � m ww w a1111 5 o z ,�1-cc o zW LLz opJo oZ°�a OQ~ — O� c9W =-- O _ Z 711i �Qm..a i W 0Uu- mWJzN ~�Q Z�JH; �--'WO W W Zp0 W - dW3H• W m ,® tiQ [p . N 2 In(n WZW rYd' YH F" ZZWfnv a¢J cn (nom W- O � www ZWz� �ZFU- . � w� Z o ..(:-I 0-� WOI- J OW =0� 2,0), 200-0 `tea \ moo Q N •- ~l~i JrW Q =Q UNpO 2,0), QO ~<WW /J,� / 2 - N MO 45J �n CO2 N.:1-z 06 1-50 arnawm /, Nvi v� at 4la 12:16,r`W m N CO CJ H l0 I 0 0.5‹ O O h C zO O I a . O l` . I U I H H H H a O U >.< O O H O I N N N '• , a i 17e- I' lq l0 C U O O II H sa 4 •-I N i OD H U Q „ � " O H O a c ro cn I) • H I I Q, w (9 ,. U U Cl) G U W - ro ro r51 # Sc " a N w CI . .H N O 1 U m co Q�d co Q 0 U rt H D a0t 3 10 Q Q O Q io ujz W mz1 1-,5( owa LL 0- O a0a7, z 00 t"R. m> W , 00. H uj W W W 4W 4-I Q, Q+ Q, Q. 04 O O O O 0 H �-. H 0000 0 '< r7 W u x - O O O LO if) n. ° a O H n H ,. iii_ a H. ';i i r LL W N T� x k Ja W W x ro ro I a H U •H N -H (1) ill N a Qaa Q a Q x I � m Hi " W Z UUUU ro a W U H H W illx fii! U Cl) 0 i i -x U) Q Q H ii ii, W !!�< . n n! : ii' n! x i5°i If W !!x Iii! p'I o !i Iii o Ir u ( Ilii ,. ii' ux f5 - ii u. 1ii. u i' H ii nx CL H. W li CI iiX CC iii 10 O Al o w i,�' /,,, • /, ,► /, H. / ,1 // / . ; /," W HI1 H 4 H "i1 /% H ri lA /4 W Z A. U X %' 4 % z z 4 0 , \ W X U) 0 ` Z 5 g LISL 1112 zccw0N co O m Oen HD �m w gwo 2 mo L'-1- W Q� xv _- C� * K!. W p ZZ �� zm pC7 J zu pi F E7, R. i w Yp = O� 00 OQ H zz Q oA F aN r— 15 z Hai H zW m H2< WQ F- \-' + �w�Z J 2 .. IP O - .Y < woo .2mZw Q �i�,\ um¢ c �, p xQ �U O� mu-LT m�Ocn \�� �v Jww W W2 T F.�� J W 2Q� O� D /�,/ / iL�¢N J a ". 4 m ♦ I, U HD 0 LL W UD <>> U��M Z /• — '.' cc W _ `'-(1`1'6I='E, 0 0J pi- Z am ZHZ Qd22 zUpd'im U N /A H W ZQUr W OH� 2WO W<H �HJH ,,v-,T_q z m H g aZz , HZ wcoO „w0 Dz;� W �� 2>z,,, Ill uwi p �H� �} p�� H 00W Y \I,s� wA ,zw lt W' R p Q 2 J. < S> 06 U O THIO m Q /,/,/ / z U'6�i Intl O0 H U W 2 Z J W Z O W > H m LLU • W ak vi LL awce,9Z H LLH� _O z� �LLz p0�0 Z a,a a�w H w OULL m m� pZw OP YoE�Ep p00 w m� a=W 2�}}� Q Z�2 I W Z W 2 2'x YHR F-NI-Z L7YY cn ww HH0 p pg °am zwzw 2zu, y) N4?t m www �mm a 'mowLLma' m,/ / <- c�i ai 0 v g_i Lci co� r;H Z 61-50 O)Q W= N X I-, * ,11W II11r. f El E Voigt & Associates, Inc. Lllib STRUCTURAL ENGINEERING SERVICES COP/ 4635 NICOLS RD. SUITE 204 EAGAN,MN 55122 PH.(651)686-7727 FAX.(651)686-8444 Michael Karn October 14, 2017 Gonyea Homes 6102 Olson Memorial Highway Golden Valley,MN 55422 763-432-4511 michael@gonyeacompanies.com RE: Sneen Residence at 765 Lakeview Parkway,Orono,MN 55391 Dear Mr. Karn: Per your request, I examined the main level garage wall(front elevation)of the address above for compliance with the 2015 Minnesota State Building Code(2012 IRC w/Minnesota amendments)bracing requirements. Your plan notes that you will be sheathing the entire exterior of the building with OSB permitting the use of Table R602.10.4 Continuous Sheathing Methods,CS-WSP and PFH. The braced wall line that includes the garage doors was analyzed as a gypsum board braced wall(method GB). Please note IRC Figures R602.10.8(1)and R602.10.8(2)Braced Wall Panel ...to Floor/Ceiling Framing connection requirements for the continuous method(attached). The attached sheet,C-1,provides detail on the braced wall assessment. The attached sheet,BP-1, indicates the locations of braced wall segments for the front elevation/garage entry on the main level of this house and the location of braced wall segments and portal frames. See Details Si and S2. You also asked that I review the tall wall at the sport court.Frame the exterior walls of the sport court indicated on your Lower Floor Plan as walkout foundation walls with(2)2X6s#2 SPF @ 12"centers,the exterior walls indicated over foundation Look Out walls with(1)2X6#2 SPF @ 12"centers and over the foundation walls indicated as Full Height frame with(1)2X6#2 SPF @ 16"centers. You asked me to comment on the tall wall framing at the exterior wall of the stair well. See Detail T1. A basic assumption of IRC bracing is that the rest of the structure is properly constructed and connected per the appropriate section of the code. The information and opinions contained herein are based upon the limited investigation described at the beginning of this report.No warranties are expressed or implied regarding the existence of other unknown conditions not specifically addressed.Our work is in accordance with generally accepted engineering standards and is not intended to be relied upon or transferred to individuals other than the addressee. Should information or conditions become known which differ from the discussion herein,they may alter the opinions or conclusions of the undersigned. Please call if you have any questions. Sincerely, P0L Wv OA:et I Hereby Certify That This Plan,Specification,Or Report Was Prepared By Me Or Under My Direct Supervision And That I Am A Duly Licensed Engineer Under The Laws Of The State Of Minnesota. Paul W.Voigt Date 10/14/17 License Number 20705 Page 1 of 1 Sneen Residence Voigt&Associates, Inc. SheetC-1 1 765 Lakeview Parkway, Orono, MN 55391 Structural Engineering Services j 4635 Nicols Road, Suite 204 1 Eagan, MN 55122 Method CS-WSP I Wind speed 90 { Exposure B I r p GB 1 1- BWL 11 Spacing-ft 241 r ; Level 2 I Length req'd-ft 15.2' per Table R602.10.3(1) i I — Adjustments: I Exposure 1 Eave to ridge Height 1.151 Wall Height 0.95 I #of BWL 1 4"Gyp WB w.block joint: 1.45 f 1 EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANEL) 1111 J 1 1 1 MINIMUM 2 PLY 2x12(3 -' X 11-1/4') HEADER PER PLAN N 'L FASTEN SHEATHING TO HEADER WITH Bd COMMON NAILS IN 3' GRID C PATTERN AS SHOWN AND 3'O.C. IN ALL FRAMING (STUDS AND SILLS) HEADER TO JACK STUD STRAP ON BOTH SIDES OF OPENING OPPOSITE SIDE OF SHEATHING-USE SIMPSON MSTC2B OR EQUAL - JC W Q MINIMUM DOUBLE 2x4 FRAMING COVERED W/MIN. - 3/8' THICK WOOD STRUCTURAL PANEL SHEATHING W/ - _1 s = c 4' MII& 8d COMMON OR GALVANIZED BOX NAILS AT 3" O.C. IN 14' MIN[ a00 4o iI ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. , ./ c.5 •I TYPICAL PORTAL - LTJ '- g FRAME IF NEEDED. PANEL SPLICE EDGES SHALL OCCUR OVER AND - 1- CONSTRUCTION ) BE NAILED TO COMMON BLOCKING WITHIN MIDDLE 24' OF - a ~ WALL MID-HEIGHT. ONE ROW OF 3' 0.C. NAIIJNG IS m REQUIRED IN EACH PANEL EDGE -� 16' +/- FINISHED WIDTH OF OPENING FOR DOUBLE PORTALS ( . i ( MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS(EMBEDDED INTO I H I CONCRETE AND NAILED INTO FRAMING) USE SIMPSON HDU4 OR EQUAL 1 Q j 1` \ \ :41' . C.I.P: .d:•. .. .. (2) #4 INTO C.I.P. .- %%/%/±/ CMU: (2) CORES FILLED W/#4 EA. 3 MIN (1) 5/8"f ANCHOR BOL CORE STD. HOOK INSTALLED W/2'x2'x3 16' / PL�TE WASHERZOTH IDES • , t • ! I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the OUTSIDE ELEVATION State of Minnesota. ODOUBLE ENDED PORTAL FRAME AT 16' GARAGE DOOR — SEE PLANP / ! • NO SCALE /C74AL -w1I/' (y/ Signature PAUL W. VOIGT 10/14/2017 20705 Date Registration Number Voigt & Associates, Inc. SNEEN RESIDENCE / GONYEA HOMES STRUCTURAL ENGINEERING SERVICES 4635 NICOLS RD. SUITE 204 765 LAKEVIEW PARKWAY,ORONO,MN 55391 1 OF 2 EAGAN.MN 55122 PROJ.#: 2017.XXX REVISIONS: PI-I.(651)686-7727 FAX.(651)686-8444 DRAWN BY: RNS DATE: 1 O/14/17 EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS) / / 9 IIII! (11111 \- -"' MINIMUM 2 PLY 2x12(3' X 11-1/4") HEADER - PER PLAN • y - 1 u ua - \ FASTEN SHEATHING TO HEADER WITH 13d COMMON NAILS IN 3' GRID C PATTERN AS SHOWN AND 3" O.C. IN ALL FRAMING(STUDS AND SILLS) (TYP.) - HEADER TO JACK STUD STRAP ON BOTH SIDES OF OPENING - OPPOSITE SIDE OF SHEATHING-USE SIMPSON MSTC28 OR EQUAL .- K X W Q - ( MINIMUM DOUBLE 2x4 FRAMING COVERED W/MIN. 1 - 3/B' THICK WOOD STRUCTURAL PANEL SHEATHING W/ 1 m x o -24' MIN 13,1 COMMON OR GALVANIZED BOX NAILS AT 3' O.C. IN 44' MIN[ a0 W I v' ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. _/ 01 O `11 b , TYPICAL PORTAL = ~' FRAME IF NEEDED, PANEL SPLICE EDGES SHALL OCCUR OVER AND - O CONSTRUCTION ) BE NAILED TO COMMON BLOCKING WITHIN MIDDLE 24' OF a ~ WALL MID-HEIGHT. ONE ROW OF 3" O.C. NAILING IS REQUIRED IN EACH PANEL EDGE _ - 16' +/- FINISHED WIDTH OF OPENING FOR DOUBLE PORTALS • • -MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO I1j I CONCRETE AND NAILED INTO FRAMING) USE SIMPSON HDU4 OR EQUAL 1 111 S `t. \ \ i.: •a' .. ' • ' • •. C.I.P: a::. .. (2) #4 INTO C.I.P. ' .. / � COR: 3 (2) CORES FILLED W/#4 EA. MIN (1) 5/8'0 ANCHOR BOLT CORE STD. HOOK INSTALLED W/2'x2'x3/16' /PL�TE WASHERPOTH S.DES ' d:'• -a :� /` . % f I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed OUTSIDE ELEVATION Professional Engineer under the laws of the State of Minnesota. 0 DOUBLE ENDED PORTAL FRAME AT 16' GARAGE DOOR - SEE PLAN IAL 41/' NO SCALE iiii Signature PAUL W. VOIGT 10/14/2017 20705 Date Registration Number Voigt & Associates, Inc. SNEEN RESIDENCE / GONYEA HOMES S1 ESTRUCTURAL ENGINEERING SERVICES 4635 NICOLS RD. SUITE 204 765 LAKEVIEW PARKWAY,ORONO,MN 55391 1 OF 2 EAGAN,MN 55122 PROJ.4: 2017.XXX REVISIONS: PH.(651)686-7727 FAX.(651)686-8444 DRAWN BY: RNS DATE: 10/14/17 EXTENT OF HEADER WITH SINGLE PORTAL FRAMES (ONE BRACED WALL PANEL) / / U 1 i f I -•••• 2 PLY 2X12 MINIMUM (3" X 11-1/4") HEADER - PER PLAN /' NI FASTEN SHEATHING TO HEADER WITH 8d COMMON NAILS IN 3" GRID PATTERN AS SHOWN AND 3" O.C. IN ALL FRAMING (STUDS AND SIL.S) FASTEN TOP PLATE 16 HEADER (TYP.)HEADER TO JACK SND STRAP ON BOTH SIDES OF OPENING - WITH TWO ROWS OF 16D SINKER OPPOSITE SIDE OF SHEATHING-USE SIMPSON LSTA24 OR EQUAL NAILS AT 3" O.C. TYP. -- < MINIMUM DOUBLE 2x4 FRAMING COVERED W/MIN. 3/8" THICK WOOD STRUCTURAL PANEL SHEATHING W/8d COMMON OR GALVANIZED BOX NAILS AT 3" O.C. IN ALL • z a MINIMUM 3/8" FRAMING(STUDS, BLOCKING, AND SILLS) TYP. c < o • 6" MIH 9' +/- FINISHED WIDTH OF OPENING FOR SINGLE PORTAL 'alo 3 6 9I SHEATHINGAL PANEL s I I o p= iv IFG CURD OPANEL BEL EDGES SHALL = 1 OCCUR OVERNAILED AND BE NAILED TOO COMMM ON1- 1 BLOCKING WITHIN MIDDLE 24" OF WALL < o MID—HEIGHT. ONE ROW OF 3" O.C. NAILING I- IS REQUIRED IN EACH PANEL EDGE IIK MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETE AND NAILED INTO FRAMING) USE SIMPSON HDU4 OR EQUAL C.I.P: i I1.1 1, \ \ (2) #4 INTO C.I.P. �. ir•• CMU: r l• "° . .. (2) CORES FILLED W/#4 EA. CORE STD. HOOK '♦ ♦ . °. - • •�, 1\\_ 1000#HOLD DOWN DEVICE TO CONNECT W000Abv I MIN 1) 5/"0 ANCHOR BOLT TO FOUNDATION I I. A WA W R "x2" /16" SEE FOUNDATION WALL_ II MI.. .. OUTSIDE ELEVATION I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed 0 PORTAL FRAME AT 9' GARAGE DOOR Professional Engineer under the laws of the NO SCALE State of Minnesota. P W• v • Signature PAUL W. VOIGT 10/14/2017 20705 Date Registration Number Voigt & Associates, Inc. SNEEN RESIDENCE / GONYEA HOMES S2 STRUCTURAL ENGINEERING SERVICES 4635 NICOLS RD. SUITE 204 765 LAKEVIEW PARKWAY,ORONO,MN 55391 2 OF 2 PAGAN,MN 55122 PROJ.#: 2017.XXX REVISIONS: PH.(651)686-7727 FAX.(651)686-8444 DRAWN BY: RNS DATE: 1 0/14/17 ROOF TRUSSES \ Sie NI" SJI, .4it' SIL° Nle 14 — NOTE: TALL WALL HAS NOT BEEN DESIGNED TO ACCOMODATE GIRDER TRUSS BEARING `o m Lo , c4 c 0 O m�O o N 3 N '''- -5.2= Q L_ V E E— " s Z < ) r 3 U m O ' 't. E OL LLI c 6 LL ry , 2 Em la co 013 O IX E c O " D ova o a II .-- 0-01:" 0 >,T a c c O " ` p W c n C m m c o i o v " O C N O m O 3 Q 0; p 0 7 Y L d j O OO O O) _ "a N N .-0 LL 0 I- HEADER - SEE 1 PLAN CD LU (3) 2X6 KING STUDS (1) 2x6 TRIMMER POUGI- OPENING = 38" ` 2X6 STUDS W 12" OC (2) 2x6 SILLS \ SIMPSON A35 C� FRAMING ANGLES AS SHOWN Q INFILL STUDS LA SHOWN TO DEPICT LA DESIGN CONCEPT ONLY. NUMBER MAY L I VARY. 0 TALL WALL AT SIGHT EL-VAT O\ STAIRWELL NO SCALE Voigt & Associates, Inc. SNEEN RES /GONYEA HOMES T1 ISTRUCTURAL ENGINEERING SERVICES 4635 NICOLS RD. SUITE 204 765 LAKEVIEW PKWY,ORONO,MN 55391 1 OF 1 - EAGAN,MN 55122 PROJ.#: 2017.xxxREVISIONS: PH.(651)686-7727 FAX.(651)686-8444 DRAWN BY: RNS 1 DATE: 10/1 47 1 7 WALL CONSTRUCTION CON`INUOUS RIM FULL HEIGHT BLOCKING I / OR BAND JOIST CONTINUOUS ALONG LENGTH/ :Z';i OF BRACED WALL PANEL. // PEPPFN(71C:i1IAR FRAMING .r .. -•3C L6"0 C.ALONG i BCd"U •C ALONG GRACED WALL PANEL ys�.�. BRACED WAI I PANEL i ,.. BRACED'WALL PANEL BRACED WAI t_PANEL 3161 g`16"0 G ALONG 1 , 3.16d @' 16"0.0 ALONG BRACED WALL PANEL ' BRACED WAI 1 PANEL , 4 KIS PERPENDICULAR I-NAM ING \ —CON IINUOUS RIMA I ULL HEIGHT BLOCKING-. OR BAND JOIST CONTINUOUS ALONG LENGTH OF BRACED WALL PANEL For SI: I ends-23 4 mm. FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PLRPLNUICULAR TO FLOORICEILING FRAMING ADDITIONAL FRAMING r 1-CONTINUOUS RIM CR Md r-FULL HEIGHT BLOCKING ! f EMBER DIRECTLY ABOVE / 1G'o C ALONG END JOIST / BRA';;ED WALL PANEL BRACED WALL PANEL I# r1 ( 'i. I . illni . 8d(c a-O C ALONG -101 NAIL -Ed -80 0 6"O C ALONG BRACED WALL PANEL NAILAFACH S BRACED WALL PANEL BLOCKING IfEMBER - moi'' - l-; +�BRACED WALL PANEL r+a—BRACED WAI 1 PANEL .+ - GRACED WALL PANEL I 3-16d&ler 0 C AL ONCE ..--3-1 6d e. 16"O C ALONG .-.1.1{;d AT EACH I/�BRACED WALL PANEL. I // LIRAIGLU'WALL PANEL �` BLOCK.NG MEMBER. 111 - 2-16d NAILS I!, /frt. EACH i.[7F CONTINUOUS It;l:1 v-ACiDITIONAi_FRAMING J1.,L HEIGHT OR END JOIST MEMBER C:RECTLY LLCLOW BCGGIwItJ(i to iti'U'.:. BRACED WALL PANEL ALONG BRACED WAIL Ent-SI: I ilidl-2 S 4 min. FIGURL R602.10-8(2) BRACED WALL PANLL CONNECTION WHEN PARALLEL TO FLOORICEILING FRAMING 2012 INTERNATIONAL RFSIDFNTIAL CODE' 1aS • 4>TYP.a BEAMING FAUX BEAM ' y/ •E ) • W:SR OPE"IING FAUx BEAM FAVJI NLAM • m. Yl:SR OPENING 1D SR OPE NING 1O 4'.0• ., 18'•0' 1 • 0 - '._- SN TRAP( 16. II x1VR WALL W!RNUNI3 i CASED OPG. ._._._ r 4 b b b { I 164>'.1r-0• m 4 I 38'n8a'42 • • b �: A �_ : , DECK L `° BARN DOOR O.S.B. ENTIRE 0 CEDAR DECIONG 'FUTURE RF-E N j 3'45- 9 . G O N Y E A EXTERIOR OF HOUSE HOMES 1 � S B]$. _ . . 6102 OLSON MEMORIAL HWY. 1qa" 6'0' ,o rs ]c o ,In` B.Ta y-,r tGOLDEN VALLEY,MN 55422 9R OPENING : • 'sa OPENING' r ' SIT OPEN NG ••-- I 2s-8• _�, low• OFFICE:763.432-4500 -.._ FAX:783.132.1501 i 11'-8' ,31Ir- IN.," ,. OFOYER/DIN. BEAM FOYER BEAM STAIR BEAM _ KITCHEN IL R"�E"SE�2`59 �•JFLR. 30P0 T s� i'•T 4 SCALE: 1/4"=1'-0" 4 SCALE: 1/4"=1'-0" 4 SCALE: 1/4"=1'-0" I {t}) FAUX OPENING 2A to LSL 2412'LSL S.DGAS LINE , @ BARN DR. J�f r- REVISION RECORD 3020 T 16'•ta'ASV.:'.• OW2'f3090.1 9'xB PATIO DR b �- r I 4--1 W-=-1-0--- 1 8-25.17 .... a2>t,D 6-0 HEAD NGT. - - 2 9-28-17 O/ (' �. o-GJE_z"eE Iwo ,n - 2-24 'Am 0 JAMBS TYP.- / , Iwo-5 1r-0" 1T-2 Iii g M DROP PLO.Hi 1.6 OFFICE DI E o g d 'i C•,,CARPET HGT, - 9'-1 1I C O,�1GT. § r • Z b ,,,,�}•• ../ ' SPOST--, CI gz __ I7 L I .1016 AWN'""' 4018AWNT "8.'%11 40�6� ,�� ! n ¢ ,,(YP. a _ _WALL A90v[.- <-:. - - WALL ABOve '='r-- ��I...�"f.,.I' 1 ---'+�r r` I '° TALL WALL: " F 5 1.1x6 SPF STUD CPT & Ur LSL 8'-0•HEAD NGT. Y 4 310' ¢- a'E O.c. ) di LW O • L.-_ SR DPG SPORT COURT BELOW $ i '"' "i;l •i• h N r_2 A f °' Ii ' (r. 184'X 164" •DROP PLT HT.,'$-•' .• `te a J°'!: -- SR 8.-4.. ,7.4r ) eM r H �,/ ,g GREATROOMM ,$ 0 �N IY-,i/6 GLG,HST, „ q 4 DINING ROOM BEAM KITCHEN S.R.O., n ? Red dashed lines indicate Gypsum �Q,� SCALE: 1,4-.1,T SCALE: V4•=1'-0' i EI b WB Braced Wall Panels installed 1 Ro N, TV %N •�' tv 7 a interior spaced 7' ( C' at d �' • N is Hcki N ,7r 1 1 perimeter # g 6, 2 THVEsxRI'D. e '•-0• ) and �Cr1_3.f'�ef 1(�Cat#t` I'#S. I Ix _... , 4 I i t.8 SOL1D,:'OOC , I 1 , m TLS. ,._.i '2'TLE I' u, 66 ' M � i FALSE-WALL _ t -§' �I ,�Y. e•SR B:R.1P-OUT 111 .:x NI o I h ABv.1,'NT. ^a- --_ Lam._ le' d ' cu vrA O ., 6" iE i o ;; 4 BASE CABINET �, 'a, Te`_. ' CABNE .;! .- •. .. i W1 � -J �e �v I �7' '�x i `(P (SIM.DPP.SIDE; I4Y I § - I ' . an r i CANT 2088 PKT 'N NI 7 ••'.4- W 6,�.� .. ?{•"e, 24 DEEPCAe. 3 • ' ,., t Wim; PANTRY Del- 36 REF : yr .. -re! �r•10 a-0 ------,-----t4:�.-y Xx AU _._.._ I... ) 60LO C 4T •'.1C' ; ' 3-2 10 _--WOOD OVEN 4.RECESS " UPPER a' 9R __ WFSR C_ § _ = ' " #(:Mf --'S��• vrn a • - Ti 6�-Lam__-}`� ---I III W • -- SPORT COURT PATE NGT.DROPPED ' '- ^c x..74' ;'.01 .3 I/O' ).0 0' Yd,7 ••O" '•8-FROIA PLATE HOT, I 'y4' ry 11 GARAGE TE IEIOHT DROPPED ' 20 MIN FRE RATED ` b' I ,Il '�"'� 77 ®GREAT ROOM FP G.R. F.P. SHEENS. ,a MAINPLArEHGT. II \___.1 STEEL y :ate p:-..ii ' Foy L Y Q 4 STANDARD LUMBER STEPS I 9•i i1B"CLO,HOT, )1( SCALE: 1/4"0 V-0" SCALE: 1/4"■V-0" b, 1 AREATED WOOD oncotic. LL h W Y �II� Lib t,w'x,r•0' 9'•4 6•-8' Jr:. 4. ,.-. - ''• it' 'I to DINING ROOM (2)1 t MY LSL r 46. T___ .w _._.__ _ fI is TY % WooD 4 �/ (2)2x0 (11x0 I I _ ___ 14'.0. __�___ .�}J; [{� ^� 9'-11;8'CLG .T. b I Q Ll. __ b: !6 + Yi 9R WRAP p i t. 1 CI C1t) .. 6fn _ ca m pCM•ql1 Ny )1) i .d r C)I j P•t014 .N& I I B N $HC.HT. Y L CI(I D REDO. .• •.18(°t �.._-.4.0'__. }... � �I I 1.91n-�'I b''I \� in $ Y 114• I i ' \ I r1 .Q ABEAM^ d >. \,• --_--_--_ .1.0-. ,s W L I*4E. 1 .J b `• R • • .'. - 4w. T.tO'HG7. 2-2x10 Cf) ^/ �l/ b- ,0'i, E"• A '4a. \ -„- '* .LEDGE - _YMIII"1=11=0�� . . - V/ 1:: • . 1 .' o \ -----.i0 7•,iHTER ;, ,•- `----- 4 1 HOL0 TO HDR •2.2x10 SH 2660 3112660 SH 2E60 SR OPENING .'. ,.. __• 2 •, , , `s Sxs- BElow LANo64G m '0• '1' g BEAM /HEADER DET, 0 SH2040 I m - • Oil' 1 '4 " ,isci ./asps ° •\ �- . \ _ 2-2•2•nozgzOTe COVERED o (GREAT ROOM WINDOWS NOTES. \ j �• FULL IGHT r T6G CEG. 0°1 DFF CENTEa POST INSULATE 6 SHEETROCN GARAGE WADS 6 GG_ \e, ,` / 4 I I FFG.- �' �•', ,. ••tn- 10-1' 2 11,J z 4 SCALE: 1/4"..1'-0" t I ALL INTERIOR&EXTERN}R r1111" / Q 3 CAR GARAGE g % rAFI a STONE I SEE DETAA ,.-FAUX x BEAU HEADERS TO B£1.1x10 ]t?CONI.FLOOR �g"� ..««'' ' ` �i C_ C! •••g(m+T•�•irr sL' 'I ' L (�,Ap�� j :Y'SR OPENING 1:NLFSS OTHERVASE NOPCD SLOPE TO DOOR •. .' 4N• f; .v�' h i i iv!" - -_,In- w/ �` _ �/� L,L. -'/ '�`P BEAMING 'O 2.;STAIR TREAD Citi \ • DROP PC HT.1-0'•• , Y K. 1�9 •A • 2.8,rJ"LS .,, •(f-�`' C//•�' 1N�J / • : SHOWN •0'•T a'4•kw( J ,i ,1C.� �;. OFF CENTE''POST 4.10, _ 'i V/ 0iii Z ' O i 3,1 ALL ANGLED WK:.S A. - f i4 _y4, , , OFF CENTER POST STONE BASE: uTf ESS OTHERWIS "CO III"• i <• a„ OG �� r -. 9'-0' TAPERED 4.1 ALL EXTERIOR cd _ . 3 ,6¢ 3•,4' 4•,n• PROJECT 4. STONE PER DIMENSIONS T �,�• V/ ' 0 ss 4$ 8.6 APETRO COST (p OUTSIDE OF SHEA"HINu 0; 1 �1T'�.y\„ `•+, _ .. r DQ� ♦ • C 1 TRTD POET _ b , n• J AL% , LP hi -`' FOUNDATION 1406 • .I MAIN UPPER W1NODM.'�i ;P, G 1,0 ,. .,, 'II IOP A BOTTOM, l''''•• BASEMENT 1179 s«. , } 0 5 NGT(TT/ANSO'AS MIME', 99:4CF1418 0 'JR SS OTHERWISE NO'EO , I, r' . -:2' _._.._ , a ,` ' '60- ,16 ,a• 1A•. ' 2,0', SECOND 1490 VEIARAGE'WALL2.n r f,4.�p •• `. .II► , J FIRST ^1 7j TRUSS 6 FLOOR JOIST MANU'ACTuft(R y�C'•' �''1.\. abr' `� ,� '•�... -_ _.__ `v SPORT COURT 450 --- - 'O VERIFY SIZE 6 SPACING Cr JSTS. •�•}`,4 t " t y.. ` -**-.,4 m ,0',•'.9 14'4' 1'-0- ,' A TRUSSES ,'.��� L. \, `'- - �" , `FFD.STONE O TOTAL 4537 SR OPENING j "gyp \� • ��, 8.14 1.'RETURNS ON ALL DOORS - !P' J� UNLESS OTHERWISE NorLD lra ` 1. U PROD, NO. 1 G.R./KITCHEN BEAM OPG/ P,ROOM DIMENSIONS FOR F#as,EUROOMS 99 ••, o MAIN FLOOR PLAN 4; �- GH0807 SCALE: 1/4'=1'-0" ARC APPROxidATE AND USED FOR .\ /- {. SCALE: 1/4"=1-0" GENERAL PLANNING EXACT ROOLI 1. ' �r DIMENSION WILL VAR,' --- '/ "^*,!� t-) tt '7 /�I SHEET , otitiNij CUR New Construction Energy Code Compliance Certificate �! ,,r,�l l Date Certificate Posted N 5/ Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel. 10/11/17 NI Mailing Address of the Dwelling or Dwelling Unit 765 765 Lakeview Parkway Name of Residential Contractor MN License Number • Gonyea Homes 2459 City Plan ID Orono GH0807 [THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply X Passive(No Fan) 0 6 1 E> o. F ") ti Active(With fan and monometer or To c _ -o a°, 2other system monitoring device) > Q — tj E _Li c Location(or future Location)of Fan:a,C• t.•_, .0 YU so s, o aa ° UO, wWx o Insulation Location a ' oE 74, - d- ° d . E- c z w w w° 2 R R Other Please Describe Here Below Entire Slab X Foundation Wall R-10 X exterior Perimeter of Slab on Grade X Rim Joist(1st Floor) R-20 X Interior Rim Joist(2nd Floor) R-20 X Interior Wall R-20 X Ceiling,flat R-49 X Ceiling,vaulted R-30 X Bay Windows or cantilevered areas R-30 X Floors over unconditioned areas R-38 'X Describe other insulated areas _ Building Envelope air Tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: .27-.3I .Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): .25-.29 R-8 R-value MECHANICAL SYSTEMS I Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code Fuel Type NAT GAS NAT GAS R-410A Passive Manufacturer Bryant Rheem Bryant Powered Interlocked with exhaust device. Model 912SB480100S21 PROG5042NRH67PV BA13NA048 Describe: Input in 100000 Capacity in 50 Output in 4 Other,describe: Rating or Size BTUS: Gallons: Tons: AFUE or 92% SEER or 13 Location of duct or system: Efficiency HSPF% EER HEAT LOSS HEAT GAIN COOLING LOAD RESIDENTIAL LOAD CALL 69582 38925 44464 Cfin's I ' -round duct UK Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace Not required per mech.code Select Type X Passive Heat Recover Ventilator(HRV) Capacity in cfms: _Low: High: Other,describe: Energy Recover Ventilator(ERV)Capacity in cfms:liX Low: 40°/n=124 High: 70%=217 Location of duct or system: Balanced Ventilation Capcity in CFMS: furnace room Locations of Fans,describe: Cfm's Capacity continuous ventilation rate in cfms: 95 5 "round duct OR Total ventilation(intermittent+continuous)rate in cfms: 195 "metal duct 765 Lakeview Parkway Orono HVAC Load Calculations for Gonyea Homes Prepared By: Josh Gray Sabre Heating And NC 15535 Medina Road Plymouth, Mn 55447 763-473-2267 Wednesday, October 11, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Sabre Plumbing&Heating 1765 Lakeview Parkway Orono Plymouth,MN 55447 Page 2 I Project Report General Project Information Project Title: 765 Lakeview Parkway Orono Designed By: Josh Gray Project Date: Wednesday, October 11, 2017 Client Name: Gonyea Homes Company Name: Sabre Heating And A/C Company Representative: Josh Gray Company Address: 15535 Medina Road Company City: Plymouth, Mn 55447 Company Phone: 763-473-2267 Company Fax: 763-473-8565 Company E-Mail Address: josh.gray@sabreheating.com Design Data Reference City: Minneapolis, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 n/a 30% 72 29.40 Summer: 88 73 50% 50% 75 35 Check Figures Total Building Supply CFM: 1,772 CFM Per Square ft.: 0.371 Square ft. of Room Area: 4,776 Square ft. Per Ton: 1,289 Volume (ft') of Cond. Space: 46,444 Building Loads Total Heating Required Including Ventilation Air: 69,582 Btuh 69.582 MBH Total Sensible Gain: 38,925 Btuh 88 % Total Latent Gain: 5,540 Btuh 12 % Total Cooling Required Including Ventilation Air: 44,464 Btuh 3.71 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Sabre Plumbing&Heating • 765 Lakeview Parkway Orono Plymouth,MN 55447 Page 3 Load Preview Report Net ft. Sen Lat Net Sen HtSys Cl Sys Act Duct Scope Ton /Ton Area Gain Gain Gain Loss g g Size CFM CFM CFM'. Building 3.71 1,289 4,776 38,925 5,540 44,464 69,582 833 1,772 1,772 System 1 3.71 1,289 4,776 38,925 5,540 44,464 69,582 833 1,772 1,772 18x18 Ventilation 1,054 4,409 5,463 7,057 Supply Duct Latent 91 91 Return Duct 45 40 85 300 Humidification 7,052 Zone 1 4,776 37,826 1,000 38,826 55,173 833 1,772 1,772 18x18 1-Lower Level 1,418 7,651 0 7,651 15,334 231 358 358 4--6 2-Sport Court 450 1,920 0 1,920 8,750 132 90 90 1--6 3-Main Level 1,418 18,985 1,000 19,985 17,541 265 889 889 9--6 4-Upper Level 1,490 9,270 0 9,270 13,548 205 434 434 4--6 M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Sabre Plumbing&Heating I. 765 Lakeview Parkway Orono Plymouth,MN 55447 Page 4 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain LOW EE: Glazing-Builder Grade Low E Windows& 523.5 14,573 0 16,330 16,330 Sliding Door.32 U value .30 SHGC, u-value 0.32, SHGC 0.3 11J: Door-Metal - Fiberglass Core 40 2,088 0 576 576 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 1467 5,823 0 130 130 foam board to floor, no framing, no interior finish, filled core, 8'floor depth 15A-10sffc-4: Wall-Basement, concrete block wall, R-10 20 87 0 0 0 foam board to floor, no framing, no interior finish, filled core, 4'floor depth R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 3525.5 20,242 0 3,094 3,094 siding finish, wood studs RJ R20 Closed Cell: Wall-Frame, Custom, Spray Foam R- 510 2,220 0 392 392 20 R49- 16B-49: Roof/Ceiling-Under Attic with Insulation on 1940 3,881 0 2,142 2,142 Attic Floor(also use for Knee Walls and Partition Ceilings), Custom, R49 Blown Insulation-vented attic, asphalt shingles 21A-20-c: Floor-Basement, Concrete slab, any thickness, 1868 4,388 0 0 0 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 20'wide 20P-30: Floor-Over open crawl space or garage, Passive, 182 554 0 51 51 R-30 blanket insulation, any cover Subtotals for structure: 53,856 0 22,715 22,715 People: 5 1,000 1,150 2,150 Equipment: 0 4,116 4,116 Lighting: 1250 4,263 4,263 Ductwork: 1,617 131 331 462 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 190, Summer CFM: 190 7,057 4,409 1,054 5,463 Humidification (Winter) 19.23 gal/day : 7,052 0 0 0 AED Excursion: 0 0 5,296 5,296 Total Building Load Totals: 69,582 5,540 38,925 44,464 Check Figures Total Building Supply CFM: 1,772 CFM Per Square ft.: 0.371 Square ft. of Room Area: 4,776 Square ft. Per Ton: 1,289 Volume (ft')of Cond. Space: 46,444 Building Loads Total Heating Required Including Ventilation Air: 69,582 Btuh 69.582 MBH Total Sensible Gain: 38,925 Btuh 88 % Total Latent Gain: 5,540 Btuh 12 % Total Cooling Required Including Ventilation Air: 44,464 Btuh 3.71 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method(cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 _11,500 17,250 8,625 24,150 12,075 1.The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2.This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. Site address 765 Lakeview Parkway Date 10-11-17 Contractor Sabe Heating And A/C Completed By Josh G. Section A Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation 11-1) Square feet(Conditioned area including 4776 Total required ventilation 190 Basement-finished or unfinished) - 5 Continuous ventilation ^ Number of bedrooms C� Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1. The table and equation are below Table R403.5.2 Total and Continuous Ventilation Rates(in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/ so.ft.) continuous continuous ,continuous continuous continuous continuous 1000-1500 60/40 _75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 _120/60 135/68 150/75 165/83 3001-3500 100/50 _115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 _125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 _150/75 165/83 18190 195/98 4501-5000 130/65 _145/73 160/80 175/88 (190/95) 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake,or both,for defrost or other equipment cycling. Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided, on a continuous rate average for each one-hour period.The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. Section B Ventilation Method (Choose either balanced or exhaust only) Balanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recovery Exhaust only ✓ Ventilator)—cfm of unit in low must not exceed continuous Continuous fan rating in cfm ventilation rating by more than 100%. _ Low cfm: ^ ^ High cfm: ^Z Continuous fan rating in cfm(capacity must not exceed I '+ I continuous ventilation rating by more than 100%) Directions-Choose the method of ventilation,balanced or exhaust only.Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts.Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Schedule Description _ Location Continuous Intermittent Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it is used for continuous or intermittent ventilation.The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls (Describe operation and control of the continuous and intermittent ventilation) ERV has wall control set to 40%=124 CFM ERV has wall control set to 70%=217 CFM Directions-Describe the operation of the ventilation system.There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance.Related trades also need adequate detail for placement of controls and proper operation of the building ventilation.If exhaust fans are used for building ventilation,describe the operation and location of any controls,indicators and legends.If an ERV or HRV is to be installed,describe how it will be installed.If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures' installation instructions.If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation,such interconnection shall be made and described. Directions-In order to determine the makeup air,Table 501.4.1 must be filled out(see below).For most new installations,column A will be appropriate,however,if atmospherically vented appliances or solid fuel appliances are installed,use the appropriate column. Please note,if the makeup air quantity is negative,no additional makeup air will be required for ventilation,if the value is positive refer to Table 501.4.2 and size the opening.Transfer the cfm,size of opening and type(round,rectangular,flex or rigid)to the last line of section D. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical- vent or direct vent ap-pliances assisted appliances and power gas or oil appliance or one solid ly vented gas or oil appliances or no combus-tion appliances vent or direct vent appliances fuel appliance or solid fuel appliances Column D Column A Column B Column C 1. 0.15 0.09 0.06 0.03 a)pressure factor (cfm/sf) b)conditioned floor area(sf)(including 4776 unfinished basements) Estimated House Infiltration(cfm):(la 716 x lb] 2.Exhaust Capacity a)continuous exhaust-only ventilation system ERV = 0 (cfm);(not applicable to ba-lanced ventilation systems such as HRV) b)clothes dryer(cfm) 135 135 135 135 c)80%of largest exhaust rating(cfm); Kitchen hood typically 240 (not applicable if recirculating system or if powered makeup air is electrically interlocked d)80%of next largest exhaust rating Not (cfm);bath fan typically Applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked Total Exhaust Capacity(cfm); 375 [2a+2b+2c+2d] 3.Makeup Air Quantity(cfm) 375 a)total exhaust capacity(from above) b)estimated house infiltration(from 716 above) Makeup Air Quantity(cfm); [3a-3b] -341 (if value is negative,no makeup air is needed) 4.For makeup Air Opening Sizing,refer to Table 501.4.2 NOT REQ A.Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent appliances may be used.) B.Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may also be included.) C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fule appliances. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units One or multiple power One or multiple fan- One atmospherically vented Multiple atmospherically Duct di- vent,direct vent ap- assisted appliances and gas or oil ap- vented gas or oil ap- ameter pliances,or no combus- power vent or direct vent pliance or one solid fuel pliances or solid fuel tion appliances appliances Column B appliance appliances Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37—66 23—41 16—28 10—17 4 Passive opening 67—109 42—66 29—46 18—28 5 Passive opening 110-163 67—100 47—69 29—42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233—317 144—195 100—135 62—83 8 Passive opening 318-419 196-258 136-179 84-110 9 w/motorized damper Passive opening 420—539 259—332 180—230 111—142 10 w/motorized damper Passive opening 540—679 333—419 231—290 143—179 11 w/motorized damper Powered makeup air >679 >419 >290 >179 NA Notes: A.An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. B.If flexible duct is used,increase the duct diameter by one inch.Flexible duct shall be stretched with minimal sags.Compressed duct shall not be accepted. C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D.Powered makeup air shall be electrically interlocked with the largest exhaust system. Combustion air Not required per mechanical code(No atmospheric or power vented appliances) ✓ Passive(see IFGC Appendix E,Worksheet E-1) Size and type 4"rigid 5"flex Other,describe: Explanation-If no atmospheric or power vented appliances are installed,check the appropriate box,not required.If a power vented or atmospherically vented appliance installed,use IFGC Appendix E,Worksheet E-1(see below).Please enter size and type.Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. • Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace,Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance information. Furnace/Boiler: 1 00000 raft Hood Flan Assisted / direct Vent Input: Btu/hr or Power Vent Water Heater: 40000 raft Hood Z Fan Assisted []Direct Vent Input: Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. 1 080 The CAS includes all spaces connected to one another by code compliant openings. CAS volume:_ ft3 LxWxH nLnW[1H Step 3:Determine Air Changes per Hour(ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) 4a.Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft3 Volume(TRV) If CAS Volume(from Step 2)15 greater than TRV then no outdoor openings are needed. If CAS Volume(from Step 2)is less than TRV then go to STEP 5. 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: 40000 Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3000 ft3 Required Volume Fan Assisted(RVFA) Total Btu/hr input of all Natural draft appliances Input: 0 Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: 0 ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= 3000 + 0 3000 TRV ft3 Step 5:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio= 1080 / 3000 = 0.36 Step 6:Calculate Reduction Factor(RF). RF=1 mi n us Ratio RF=1- 0.36 = 0.64 Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000 Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area(CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA= 40000 /3000 Btu/hr per in2= 13.33 in2 Step 8:Calculate Minimum CAOA. .I Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 1 3.33 x 0.64 = 8.53 in2 Step 9:Calculate Combustion Air Opening Diameter(CAOD) CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 3.30 in.diameter go up one inch in size if using flex duct 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method(cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,2504,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 _4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1.The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2.This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. 'a1FORTE iiii 7110 765 Lakeview Parkway, Orono, MN.4te cop_ 01:Upper Level Member Name Results Current Solution Comments Bedroom#2 Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Laundry Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Master Bedroom Window Passed 2 Piece(s)1 3/4"x 9 1/2"1.55E TimberStrand®LSL Bedroom#2 Right Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 02:Main Level Member Name Results Current Solution Comments Office Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Dinette Patio Door Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Great Room Window Passed 2 Piece(s)1 3/4"x 9 1/2"1.55E TimberStrand®LSL Dining Room Dropped Beam Passed 2 Piece(s)1 3/4"x 11 7/8"1.55E TimberStrand®LSL Foyer Dropped Beam Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Front Door Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Dining Room Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Porch East Dropped Beam(V) Passed 2 Piece(s)1 3/4"x 7 1/4"1.55E TimberStrand®LSL Porch Dropped Beam(H) Passed 2 Piece(s)1 3/4"x 7 1/4"1.55E TimberStrand®LSL Flush Beam Over Front Door Passed 2 Piece(s)1 3/4"x 9 1/2"1.55E TimberStrand®LSL Stairs Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Stairs Flush Beam Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Ref.Recess Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Pantry Header Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 Mudroom Door Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Garage 16'OHD Passed 2 Piece(s)1 3/4"x 11 7/8"1.55E TimberStrand®LSL Garage 9'OHD Passed 2 Piece(s)1 3/4"x 11 7/8"1.55E TimberStrand®LSL Garage Back Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No. 1/No.2 03;Lower Level Member Name Results Current Solution Comments Game Room Patio Door Passed 2 Piece(s)1 3/4"x 9 1/2"1.55E TimberStrand®LSL Rec Room Window Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Dropped Beam Bearing Wall Passed 2 Piece(s)2 x 10 Spruce-Pine-Fir No.1/No.2 Flush Beam Exercise Passed 3 Piece(s)1 3/4"x 20"2.0E Microllam®LVL 04:Girders(Sized for point loads only) Member Name Results Current Solution Comments Roof Girder Over Dinette Passed 4 Piece(s)1 3/4"x 24"2.0E Microllam®LVL Garage FLR Girder Passed 2 Piece(s)1 3/4"x 9 1/2"1.55E TimberStrand®LSL 05:Tall Wall Member Name Results Current Solution Comments Stud Passed 1 Piece(s)2 x 6 M-12 Framer Series"'Lumber - West Window Passed 1 Piece(s)3 1/2"x 5 1/2"1.3E TimberStrand®LSL(Plank) East Window Passed 1 Piece(s)3 1/2"x 5 1/2"1.3E TimberStrand®LSL(Plank) Window Columns Passed 2 Piece(s)2 x 6 M-12 Framer Series""Lumber ., . OTIIJNO l'A -t Forte Software Operator Job Notes 10/12/2017 1:48:07 PM Alex Schoenbauer.EWP Specialist Gonyea Homes GH0807 Forte v5.3, Design Engine:V7.0.0.5 Lyman Lumber Company Sneer Residence 765 Lakeview Parkway. Orono. MN.4te (9521 470-4803 765 Lakeview Parkway.Orono.MN alexschoenbauer@lymanlumber.coin 10111/2017 Job#22376 Page 1 of 35 Q,^ •,7�5� 1.6£99 NW `ONO2JO 8 °' 88 `. N • • V/ 3i ^ 1 g v _vvv a CV) AVM>I2�`dd M3IA3N�d1 99L c o }� ZNN M�I/ 2NV1 - ZN3018 - 101 oZo Cr) 0 Z 3 � Q � d, og l ` I- join W • • °_ 3 g t N 2ON3QISJ J N23NS a § s a S3WOH VBANOJ LI-OZ si ,, $ r ZS o 0 Om O p 1,'•78 hA 4 8g ,110.7100, '1m1T11la • 1no-wool 'Lfs1T1w g i <g 2 21E 2 z=II g .> 1ffq ',<< Pt. $A IF ; �Oqf , Iii Ii i ot 18 g • 4ppS L iqWO Qi*,ieg ;ji —�-� --- .~11:§1 08§ 1R a W Lan A • o®�Ior 1 , U b i t 1 _ �� • Il l Iu'so1 �' I oir� 4' i-- 6 '- I-I. 4 �� I gZ3� . 1 I on g9- 4 < �� $s1 bd iQa ■ $s9- 3 1 I. ao .A 1 1b _ 15 t',. 1k .8 % . , ._ =It---- 1 = • -----I , 1 t §it 1 $ A 13 f t:b..i 1 O ;ik b br CA# '• Y �� , • 2 z dos/ it 31 •� 30g 1 $s s� ik 1 ;1 � ' Q sN 15 2 CL •IVi -.jN JU<XIW �4 gg -I _ `, (j i I O $� b i N s3ssnalaooTiAa # 3 I 1 t u�l 1 $+1 $c I°�1 �,I ' �"'s LL '1 I� po i' v� giii):. It b i i 1 c0 1 0 low 1 nvn ze $. $s ) q 0144 '12--011!-Z-.4' i,v-j b > u, I L—— i L. , �' I '1"1".'9" tl Nj.'•.,4 e3 2. ,_ • ..���•• 1 Ill •O c§ 4 g I lr-`I " it'4 v3S fl L i111b11ow1 et,1- I, .o r '1111 'Itii-1-,;., .-f! — m1. - 1 i w ( s3ssreu>romi� J, I 0 m `Y'� 1 �3:} E a � _. - .vs \� 0 ® ,^9 WALL 9014 J4L IF wmC/vtle'vmw g 11—L1—I—t I 1-' A. ,-13- — � "r I 1 I br• h I I M I W b I�. L 7_I 11 1 1 1� . 14. - ■i : rnr 1. ilg ik1� � $ �S l \ V/ , , 1 "I "'.9 ..Lowmi-am.o-a -I" MIR . ,!r ,alp 4E8 IP -S. '�--...---- --+- 5N - +---- -.r-'-__..__.-- .00 .9-r, � I Ig 0\\ s3ssna b0019 At I '.' TI 1I ; W Fi \ \\\ / i,. L h L i A 0/4-z _ 4', $.n .9-111 a3o \ '1-9--1T� rT-rT-rT -ri-r '''I I .a 81",. t A;�\ V I I I I I I I I I Ili, 1 ` - i t. •j) F F 30 1 tom• 7• \`\ \ y\, \\\ CO9-" el m 81 g g a� 1 � o / \\ ¢\\\. - Q 8 g 1 €8 8 I ` 0 3 0 �R \ ab�- o Z 11‘i , 1 ./ \ / fI O 1 / 6 1 ''® W . . . , � •6l. '� \\� � •tib.4�`\ f '10H T117d ED W � \ �� �/ (� A-sz .3lPA / \ \ yv �. OW .9-.01 - $a �� � a. , \N At•A Q • \\\ �,; '9-r A r-----1 cs,, , II M W $1' $� O 11, IMI W c \ At-.9 s-.tlz-.4z-.`r A-9- f I 2ui � Q 1 $s ,� Q 11 II` e; vi >Qj CD If, j to-.d .A1•s - 4 CO w V ! jdi J { 1 !1 l8 < a N to 11.1 - :iv 311$1 C� fA i kill ---.]: I LI >CO AAOQrillirli 1WLi - 7 Foo a o U) U.. 0 \ czn . oN II 1r 11 01, ., oN/ ,I 1I ,L.L ._. _- W ? N v y LL 'v < Qb LL _ L1- a`Ml.-7 0di I _ Qa Wa 0 . d• a i W a \ 1Z' of 0 of A's 1, Eg o OC y Moi T ...a 1 -.-_--.Ai.A -- 1.e•1 $1 - - • • WY"SEA86"4"° FAUXR BOPEN W/SEAM ING e G 1e WI OPENING1e AV/SR OPAUX@ IBMs 6 rr 2.-0. • • ��r - -�� Tamer W 2Tamen \ S'p and Lager' \ SN TRACK ./1. ' :,iiill'il ''',.."-, ,..". •••Unless Woe ppembe"• IGEE WALL 22I EN.11/111MTL;1111 RALNOI CASED OPG. k 11 k I? BARN DOOR O.S.B. ENTI 'iI CEDAR DECKING 3.4. GONYEA II EXTERIOR • :� SE IFUTURE SCREEN ° g gI PORCH LOCATION t HOME S _„107,9, 0�, SR OPENING -1' ` 74. i.SROPENING r SRrAo• �'.p ea'r 8GO DEN VALLEY. MN 422 } i ' OPENING 1B4• ------ , 2rr , 20'.0* ,-- ___ RCEA7e3132N-0300 501 FOYER/DIN. BEAM z FOYER BEAM 3111/5IZ" "'r 12.413. : � r4' 11BUILDER U EASE Y2459 O O (5- STAIR BEAM �ol.� KITCHEN 3Y7 51+ rr rr ar r-r 4 SCALE: 1/4"=1'-0" 4 SCALE: 114"=1'-0" 4 SCALE: 1/4"=1'-0" p�,Ln•... ' 'I ' W/ FAUX MMNG 4SYMINIeL ta•OiiJAL LOG.T4..GAs L I 1 Q@ BARN DR. REVISION RECORD )0 18'-17 ABV.SPORT•e - •T SN 3080.1 VW PATO OR. � ,I `, .ice—iii, I; ,�-- = 1M 1 0 i 8-25-17 � I�—�— 3020 ' .LEDG 17 . 2.2 0134r HEAD NGT. �. `2-1t/10 lii 41 l��1�3iB� sTUDSO . ,r-0'x,7.7 13'-r.1ra'dl y 2 9-28-17 (c�QF DROPPLT.HT1'T �p �I DlNkllk p 4 • wood °° s-111r aG.NGT. s-1 1/e•CLO.KT. �` i,- i 2 blie • 0 I R " -. 4058 PICT IOSe�ICT 14DBe PICT Iy — oZ 4016 ANN IO18 WN /018 AMM le 5 o�- �::--_` nuA9z'vt`—_' , `Its'-n c a...� .,r� .NE.w 4 11 - 1•O I OI I W° b 1iL- i SPORT COURT BELOW > ` `, RI I : ' l 15-0 ur11,61E� `DROPFLT.HT.I'4"' 7t )..P. 1 V,/��7 rr :zo"i d s i E'+ R T OOM ►+ T-1 1 SR OPENING 1 a 1 3 E I r,7 I 5,0,.....i - g I1!',,,Y-14 r-1 11r CEG.MGT. �` 4O4 DINING ROOM BEAM KITCHEN S.R.O., p . g I �I_. SCALE: V4"=1'-0" OSCALE: 1/4'=1'-0' a 0--�� --�+�� f�t�" MO I'h.] b V��`Y "'� _e.NI gn 1�1r3:i k3FI.' IOTAEE, 4,S P g '1~• J �Y I t. 'i! pi 1 t3� d g TI. Imr•* I I x1r o. T'1-7r _® ..m Al - 19 ___.- I ,2' _____. ‘a \ A WD 1 7-7 7r -e'-_ FALSEMNI � !.1 SLf� qL� BASAsvN"BI �.- - W- '; reh--_.�- - I ` ABOVE CARNET gl MI WALL - I ~rdi I I i .. (SIM. PP.SIDE) 74tvi 0 CIA. �� _ 1e'd. _ ' 14'OEEP CAB. �MI I .�. �, `�' 2 Ir: c tr - � $ �., II wooD ® to ' r r-17 e'r 4 I' 4 II ' ' ® 20B■PKTii Fri1WIh r_ -'IL- �-.1 { �a � � 1 1 1 ��� •�� =PORT COURT PLATE NOT.DROPPED 'I ■ 1 T EII - �1 - ,,' Voi• ofI zr W 7'41? y'41 74113 iI.47 7.0* I 1,0.FROM ANS TE HOT. U ) z-Trir sr e4• uvL 2.1,4,1“o 1rr 7-0" ' } _ Lt ,I E11. n T r4"iwr I� Q GARAGE PLATE HEIGHT DROPPED 20 MN FIIE MTE. :4_ 9ER ABV 1 . GREAT ROOM FP oG.R. F.P. SHEENS ,•r FROM MANPLATE HGT. 11 STEEL DOOR �2pw ! IIF _ — Li Z Y \A/SCALE: 1/4•=1'-0" SCALE: 1/4"=1'-0" N -1 : ..: y, • �a lig r-,1w NGr. b Ii 1,'4'.1zr D �/ 4s r4• s•4• 1�1 r4• - I �� ii. oDININGROOM o-a W Y (2)117Ar LSL M 5 /: Fi^C�-.�. ,,.. rF WOOD 13 �8 (2)2x8-, (1)1.8 .\ .I _ F;- 11'r �' um T,�IL3�^� 3Y iM - ; ` ^ Q Cie }- 'E�,_ \ / r-11:CEG.HGP. Lel ' :,. SR WRAP �• �` ;/ LL .. /' C�1— ( m g 1 o� II LI D ' � - (n ") lw'. 1H �IO.�. $LOCKING AS REoo. 6. -r-rY i ■�!_�— 'L- in AM !s ,wI i .L ,� III \• I." L�ia ¢ ,� �' Y 11 , `, u in _ m m lo.� DIIII \" _ w 7movE r e b 80 LEDGE I z9I IA AL ! ��.I� co 0 W Z �,q" HOLD TO HDR T' su sN moo SN28%(1 O �, 1_-SR OPENING /, d� ®� ,' `\ �'�� I�IfWIl,�lil®CC LLOW LANDING I Z'Z.r IO .q� r W 1 > G J 9 BEAM/HEADER DET! :/ 1�5 ,roc \ x\ Ba'7, \4p �� %al :�._ .� o CovEREo} " 2 Z —mi W -~ �- \A/10=1,v S./ ` 0�{/ s\\ ``\ �� \ D ¢�'' '.r -�r.iE�e.' •° � w - Ill I O jAs; 4'. II�1fi \\\ ``\ / ,, `, / CONC •p F Le a GREAT ROOM WINDOWS NOTES: / / Ili / 4111 'i?' a ONE I � Ti-7 171' J W r Z ' ,1, ^INSULATE 8 SHEETROCK GARAGE W S A CEG" , / \,T, I OFF 'POST 4O SCALE: 114'=1'-0" 1.ALL NTEwoa% I _.�E __ ,^ EXTERIOR I 3 CAR GARAGE ,�" D.ST ■ 4 2-7 lJc a.N, N SEE' T FAUX BEAM HEADERS TO BE 2,2.10, VIII J 1/I CONC.FLOOR \ d'S / i ,; 1 '� 4r•� [3 111 'I -,... g v, , A{/ W/SR OPENING UNLESS OTHERWISE NOTED SLOPE To DDDR //g.AY �`� I IS �#UyIIC■ �_i I t+■• —— — b til Ir�41 I W O (Q r�TYP.o BEAMING b Z.)STM TREAD GUT V I "DROP PLT.HT.1'4••• '� LL Q •I ,,.1 / I 1 :d; ,1t�* 1L..1, //�� L� --� SHOWN 17-73/4'MAX RIs Q �/ OFF CENTE-PoST >- C// —I N. O Ya m 3.)UNLANGED WALLSE TT40*4TED �IIIIII1 \ {I'�P E/..•40..-- 1. �'ale.." ` �`+6�?A \•� /�0.: �/ SE eETAII :TI} I OFF CENTER POST 5 TAP°EREO ¢' �I y • IrvAS �' d • ¢/ ��111 iii STONE PIER. O PROJECT s.)ALL EXTERIOR ti' IIII ^. `\ '` •/ 6/>S -� SQUARE COLUMN'DMENS/ONS1 `Y' 6se TRTD.POST //� 1111 � OUT SHEATHINGIII'^�•\�°�v. 3. /� , ' `p ` ` / I �� T.� _ .` I- V FOUNDATION 1406 LL- SJ MM AND UPPER WINDOWS A - '•. \, ,?1 /� ,�_(. ``� ` \ // / iL , ' . . �— T 8130TTolA. BASEMENT 1179 UNLESSOOTHER NOTED Ilk. OFpr�� �� �.F 1rr 141$ Y. "� /1;11 , trr .. 1r FIRST %.)GARAGE WALL zxg � C`? �, 411 p O SPORT 1490 i 7.)TRUSS S FLOOR JOIST MANUFACTURER sib I'\,�.'7(P may.(\•1(r' \\ ''LIII ��ll�Alll �+• N SPORT COURT 4� TO VERIFY SIZE 8 SPACNG OF JSTS. /' yi0- ,9" u'r `I.r •L aTRussEs 1�� E.; •\ ////v ''� �'/ STONE O TOTAL 4537 1 1 ti _..1 SR OPENING %.)4 1Ir RETURNS ON ALL DOORS 0't ` o X UNLESS OTHERWISE NOTED '''11,4410,0011111,41',,,IT ' � \ MAIN FLOOR PLAN / U PROD.NO. 3 G.R./KITCHEN BEAM OPG. 8.)ROOM DIMENSIONS FOR FINISHED ROOMS \. '`► ® ¢/ Hes..SP.� G H 0807 SCALE 1/4"=1'-0" ARE APPROXIMATE AND USED FOR ( s 2/ Up to rlr•tTrwnmar Heeder Sp.,e: SCALE: 1/4"=1'-0" GENERAL PLANNING.EXACT ROOM II ` .:i W V end tsiger•z Pawner DIMENSION WILL VARY. II,• �` / ww4 Ir.1Taem. •_uMese Nmes1anervae- 'I ''914111/11. � 1 ?7IIAN.lE d4A0 LAW Mam'.ee0"n •SHEET 411011. 'P7 • `tv • O F 7 I iCA urs i 2g y7 p � 'L W AFsm I8 g9= 15 Ng ; II; O� girl * gU O a SIA O,D i� 1 �1§ t 1 TES itr. gR t 16 11' g El ii ' °g g, 1 4011 ,, i X• Hi) M o0 Om , ON < < m _ 32 2 ,,, , N. 0 h _, J� ,, . 0 , i -r), , „,..‘ _T .. 1; 0, m ,„,, 11196.a.-77-.7D' -A r . . m m a o 1n u , ` w 4 T1 I1 r m v I -6 \ 1 M Z 9 r-O 1y I 0.o i O J O li 1 I Om0 , O 01 'IIL ,,,\\_c 13 `nnaEw 33 fir+ Z i1 `p1,`1 - N.I fl `�, ' w F / \ - 1 , I- gill I - r. ;�'� eoa -1- .____+__ gg --_. . --- IR-tr� I aiga$op4 IS I �y-77�y / ,gimp.,.-- I I g 1 1µt6.1..L...-T,.,, ozj371 1 Ft1ii:iL 9N�T 1 il ::4 f _- I € AAFG.ROOF TRUSSES \ 3006 h1 6 li ?f0' T. V'_ ill \ _— li: Iii © 2017 GONYEA HOMES N m ° y y fi SNEEN RESIDENCE m ° I0 ' • yTTS< m Xf]�L�' 00 N p m�z J =O Z o -1 O N N 2 m aw m 7L �nn C LOT 1 - BLOCK 2 - LAKEVIEW 4 ; 2 ��<rg V, 0 O A Z o m bNzp m o A 765 LAKEVIEW PARKWAY o ��Y� Nm • • -, J W A°�" $ ORONO, MN 55391 p �N D d Sa9ly( t/V t"-FI CQ 10 N Joseph Olson D.B.A. Rusty Olson's--Soil and Percolation Testing Joseph J. Olson--MPCA License#810 11481 Riverview Rd. NE, Hanover, MN 55341 (763) 498-8779 Fax (763) 498-8290 November 20:2017 — Gonyea Homes 765 Lakeview Parkway Orono. Hennepin County This on-site Sewage Treatment System is designed for a Type 1, five-bedroom home in accordance ‘N ith the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. The periodically saturated soils were located at 20-24 inches(mottled soil). Due to the periodically saturated soils,a pressurized mound system with 6 inches of rock will need to be installed to treat the septic effluent. The bottom of the treatment area must be located at least 3' above the saturated soils.This system is designed with 6 inches of rock. The absorption areas of the two systems do not overlap. The soils at a depth of 12"have a percolation rate averaging 9.1 MN. A 2250-gallon septic tank is designed for this site.All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs must be installed on the end of the laterals for maintenance. Use 7/32 inch perforations on the laterals. A Darwin 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and switches must be located outside the manhole and pumping chamber in a weatherproof enclosure.A warning device must be installed with light and sound devices;this is in case of a pump failure. A flow measurement device must be installed. Including but not limited to a water meter. event counter, running time clocks or electronically controlled dosing. Keep all heavy equipment off of the proposed treatment areas before,during and after construction. The area around both sites must be fenced off by the contractor before any construction begins. With proper installation and maintenance,this system should have no problem in treating septic effluent effectively. Nothing other than gray water,(laundry, showers.etc.)Human water and toilet tissue should be disposed of into the septic tanks.Garbage disposals are not recommended. Iron filters cannot go into this system. Additives must not be used they may cause harmful damage to your septic system. It is recommended that you pump the septic tanks every two years. Sincere Joseph J.Olson ‘ \ SZ'601 3„9£,ro0,,c9N 3,,I?, ''g0.69s ,-•••-,- ....' , • _. . . .-__ - ....... U s '-•,-7 , — .... \ .,- I \ , !,, — _, ------...,,, 1•__ -.... , (..,,,, :s..4.. \\17_\ e'..:::"/\,'.7 7‘:Zc., -IN i I''' ..- .7....---..7 7: ' ! • ---...,_ . .,-..-..\ tt••••••*5' .. ,•,...: 7,.. ,•• \ '‘.. ' ,,•,,,' ,_._„ / \\ Fs ;... .7--, ,. N., — .,../ \' .7-,'......" 1 101 t: N.)() I U , ----„, ----, \•"- ____ , ,* 44-- , , 7.0' • 03,-. . • , .;., \ Or-- r• - t. '''''' -. ‘. t: . \ 1 x . - .-. '''-;"•-• 4111,),... - .. i A -- •-•\- .----lei N . ("Th 1 ' t ' A t •", \ ; t , I 1....„3' ' et. ' giowr• '.. -,-- \ ; " i IP .451A/5'.\,, - • tof' 11, \ \ i.... , \ \ C.:1, 4 / *411114\ ' , \ \, 1 . , ., .c:n --......___ . \ • ''... \ /' '''''N,1, N., -------"------ --......... . "e/,,e:0 ' / -9/ 5 ,,C'N, ......_____ / ---.,,,,. ka, 1)•'G6 s , ' I . I , , *..,..„.... , ,„, S., k ‘. ''.....,., ''''.., N .t• --- ).__. t LN 1 111 ...N.,NN ..,, ";., • .., N ,.. . -..N _ / ‘N. ' ,.. ' • ,. ...'- . .: .. . . N 1. T '''•, --„, 0..,.. • -.) _, / .., "eob0.. •, dp -.:7v.- .N\N.' I N .'•• '6' , ,NI , 1XL-3 pesht4tD `/�.? Mil %zoiLs I IL. 1164- - -• • mat it tit- " ,t(c.) amitillb-10111-Mal 111111111 ' lIltjglig r 35.E 7.......�... . .. - _.✓ - - - - i � f 7 � . a - - Aillellbb.„3±-16- 9390 C<ac OiugutrFY A0 97 . a.R7 i }AV maiE L41A So Yra+r s+ie+t ora*& c _e,s aa,rk 1,4i4• tm.s aAis j g3'. - . ' SII. BOEING ELEVATIONS E MOUND SYSTEM DESIGN t'jt {? 9 0 Mitt EL.-4`090 Type 1 _._31_Bedroom,Average percolation rate `7 IN,AACKa TKO EL-a / 7.sv gal/day _ G 3o sq.ft.of treatment area Gov (/10 ft_ width= /a ft.length of bed area Y#all -'froniProPertY fines - 'SEl"-,,,1°0 Side slope run -' to 1 x! .. height= _ft.x8°ft_Lawn area_ .i.s...Ova Was. 1Yeilosat insben Moue -..; tiattauss Clean rock needed us to•»-•- ' plus 20%�,�cu_yds.Coarse washed sand()cu.Yds.Average sand depth /.8: Tosabitent welt as two pioresty MeV Sandyloam /96Imp was cu.yds.,Topsoil 6 cu.yds.plus 50%a cu.Yds_ 0.1 bunbk dom • Number of tanks / ,f tank 1.2_gam,2"a tank____gals.,Pump chamber capacity L30v 1. gab 1100 lineal feet of "dia_Supply pipe,lineal feet needed f=": G� �' - •! ..j' LAILS. /6 -- - oat.�A t . /...„...;;; 't,. . Distribution pipe__"dia. ' .. lineal feet, 7'�s dia.Perforations `c "apart Float set at gals., times per day Pump curve j__/min. ''-->feet head pressure. __ . Date:L J , Ph. 763-4984779 Rudy Olsartsp rAnd PeroolatIon Te$ling • 2011 purple code Mound Design www.SepticResource.com (vers 15.2) Property Owner: Gonyea Homes Date: 11/20/2017 Site Address: 765 Lakeview Parkway PID: 0611723340010 Comments: instructions: =enter data =adjust if desired = computer calculated - DO NOT CHANGE! 5 bedroom Type I Residential System 750 GPD design flow Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks 4 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) Tank options: none 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed 6, 10.0 ft rockbed width 63.0 ft rockbed length 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) end feed manifold connection s) 3 laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total (1/2 a perf means the first perf starts at the middle feed manifold) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation for this perf size & spacing, & pipe size on line 12, max perfs/lateral = 30 , line#8 must be less --> OK i()i 4.0 doses per day (4 minimum) 1 i) 188 gallons per dose (treatment volume) 2.00 5x 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement 2.00 3x ;) 97 feet of 2.0 inch supply line leads to 16 gallons of drainback volume (Tip: "top feed" manifold to control the drainback) 14 204 gallons TOTAL pump out volume (treatment+ drainback) l;) 17 feet vertical lift from pump to mound laterals, leads to a: lei 36 GPM @ 27 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) 17 750 gat Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi leads to a is) 8.0 inch swing on Demand float, or timed dosing of 5.7 min ON (confirm pump rate with drawdown (this delivers Average flow, =70%of Peak design flow) 9 hrs OFF test and adjust as necessary) 1g) 12 inches from bottom of tank to"Pump OFF"float 2u 20 inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed :l) 23 inches from bottom of tank to"Hi Level"float, or 33 inches to"Hi Level"float if time dosed 22) 714 gallons reserve capacity (after High Level Alarm is activated) 23) 0.45 gpd/ft2 Absorption area Soil Loading Rate, which gives a mound ratio of 2.7 (minimum) (this must match the soil boring log) desired mound ratio 2.7 34, 12 percent site slope (0-20% range) 12 (%downslope site slope, if different than upslope) 22 inches, or 1.8 ft. to Redox or other limiting condition (need at least 12" to be a Type I) Treatment zone contains 0 inches of 0%soil credit, and 0 inches of 50%soil credit. Giving a: ,,,, 14 inch, or 1.2 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONS!!! 27 27.0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:) 2s, 0.0 ft. upslope and sideslope 17.0 ft. Downslope Individual slope ratios give BERM widths (topsoil beyond rockbed) of: ,,,) 4:1 upslope ratio 9 ft. upslope berm 301 3:1 sideslope 13 ft. sideslope berms 31) 3:1 downslope 27 ft. downslope berm 32) Overall Dimensions: 10.0 ft. wide by 63.0 ft. long Rock bed 46 ft. wide by 89 ft. long Mound footprint 4" inspection pipe 18" cover on top <Upslope berm 9 } Downslope berm 27 12" cover on sides (6"loamy cap&6"topsoil) 1.2 Clean sand lift [ 1.8 , Depth to Limiting; Limiting Condition ___. _—_.._ -__._-- _ Absorption Width Note: For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. 33, Rock Bed: 10.0 ft. by 63.0 ft. by 6 inches under pipe, plus 20%gives 21 yd'or*1.4= 29 ton 14, Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) 19.0 up + 81.7 downslope + 12.6 ends + 41.2 under rock = 235 yd'or*1.4= 329 ton plus 20% 35 Loamy Cap: 42 ft. by 85 ft. 6"deep, plus 20%gives 88 yd'or*1.4= 123 ton 301 Topsoil: 46 ft. by 89 ft. 6"deep, plus 20%gives 91 yd'or*1.4= 127 ton I hereby certify that I have completed this work in accordance with all applicable ordinances, rules and laws. Rusty Olson"s Soil Ft Pert 810 11/20/2017 signer Signature Company License Date Installer Summary 2250 gallon Septic tank (minimum) Tank options: none Dub carser LafK WW1 rnuuipce comp/LanKS 1300 gallon Dose tank (minimum) at 25.49 gpi 36 GPM® 27 ft. of head, Pump required 8.0 inch swing on Demand float which translates to roughly 5.0 inches of float tether length if time dosing is required --> 5.7 minutes ON time Et 9 hours OFF time 20 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float 23 inches from bottom of tank to"Hi Level Alarm"or 33 inches to"Hi level alarm" if time dosed 97 ft. of 2.0 inch supply line with end feed manifold connection (Tip: "top feed"manifold to control drainback) 14 inch, or 1.2 ft. Sand Lift Mound 10.0 ft. wide by 63.0 ft. tong Rock bed 3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing 7/32 inch perfs 3.0 ft. perforation spacing No Effluent filter 8 alarm 3 clean out&valve box assemblies 27.0 ft.Total sand ABSORPTION width (minimum) 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) 17.0 ft. Downslope (sand beyond rockbed, minimum) Specific slope ratios give BERM widths (topsoil beyond rockbed) of: 4:1 upslope ratio 9 ft. upslope berm 3:1 sideslope 13 ft. sideslope berms 3:1 downslope 27 ft. downslope berm 4" inspection pipe 18" cover on top Upslope berm 9 Downslope berm 27 } 12" cover on sides 5---+ — (6"loamy cap&6"topsoil) 1.2 Clean sand lift 1.8 Depth to Limiting Limiting Condition -- --, _ __-_ ._ Absorption Width ( 27.0 1— — —- — Note: For 0 to 1%slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. Rock Bed: 21.0 yd3 or*1.4= 29 ton 6 inches under pipe Mound Sand: 235 yd3 or*1.4= 329 ton calculation based on 3:1/4:1 slope from top of rockbei Loamy Cap: 88 yd3 or*1.4= 123 ton 6"deep Topsoil: 91 yd3 or*1.4= 127 ton 6"deep INSPECTOR CHECKLIST - mound /65 Lakeview parkway V%H.1. setbacks: 20'to pressure tested sewer line (5 psi for 15 min) 50'to everything 100'to dispersal area with shallow well PRUPI:R I Y LINES setback: 10'to everything Riad setback: platted: 10'prop line. Metes a bounds: out of road easement, or outer ditch. 1..1Kl. 131 1'I P setback: 20'for bluff. Lakes: GD_, RD , NE_ Protected wetland_. Building setbacks: 10'for everything, 20'for dispersal area. N A11,R LINT:under pressure st.10'to bed,tank Et sewer line. (else sewer line > 12"below) nSewer line a baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') (no depth req's, clean out every 100', Sch 40 pipe) riSeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) mfg 2250 gallons none Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. _ No effluent filter a alarm Dose tank risers and piping (water tight, insulated, proper depth, drainback) mfg 1300 gallons n dose pump 36 gpm 27 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF C float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length 204.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected LABEL pump requirements and drawdown on riser or panel Cam lock reachable from grade - 30"max. J-hook weep hole. Supply line access (no hard 90's) 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. splice box / control panel / electrical connections flow measurement: CT, ETM, time dosed, home water meter mound absorption area rough up mound rock dimensions 10.0 X 63.0 Sand lift depth 14 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) nAbsorption Sand beyond rock 0.0 upslope 17.0 downslope Bermed topsoil beyond rockbed 9 upslope 13 sideslope 27 downslope cover depth of 12-18"+ VERIFY 3 laterals (1-2'from edge of rock) 2.00 inch pipe size (Sch40 pipe a fittings) 3.0 ft lateral spacing 7/32 inch perforations 3.0 ft perforation spacing Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY clean outs (no hard 90's) 4"inspection pipe to bottom of rock, anchored VERIFY Abandon existing system - if necessary Re-use existing tank certification monitoring plan and type well abandonment form - if necessary i System Elevations v 1.4/4-,--,1,- ,.‘04.1.t.,%. 1 benchmark - SHWT Mound r (Grade elevations are existing. If a loamy cap different final grade is desired it should lateral be shown and described here.) bottom rock grade (at upslope rock bed) SHWT (at upslope rock bed) 1 / 1 / ���A�ALu4AWN1.4,40 .141 A,�►AA 4MWA •oNtA NLIN VALtAitAV1eA,A411" 01,44AVllAsi JA' i1.4.irtlJ µ„ �l•�It,4Ad.�l1A�fV4N' 11.Aw1�,{��W. l � r� I I i I 1 L7 Sewer pipe exiting house Septic Tank Septic Tank Of applicable) Pump Tank Grade Grade Grade Grade Pipe inlet inlet inlet Tank bottom Tank bottom Tank bottom Soil Observation Log «ww.SepticResource.com vers 12.4 Owner Information Property Owner/project: Gonyea Homes Date 11/17/2017 Property Address PID: 765 Lakeview Parkway r Soil Survey Information ❑ refer to attached soil survey Parent matl's: E]Till Outwash `] Lacustrine ❑Alluvium [ Organic ❑ Bedrock landscape position: ❑ Summit ❑Shoulder 0 Side slope ❑ Toe slope soil survey map units: L41C2 slope 12-15 °ro direction- Linear-concav e Soil Log#1 0 Boring ❑ Pit Elevation 949.0 Depth to SHWT 22 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-12 Topsoil •-7;5 I Ovr3'1 l.nose Moderate Blocky 12-21 Loam 3; 10. r4 3 Friable Strong Iii,,,AN 11-30 Clay Loam 33 I0�r5 4 I0y4%8,1-6/IOy I viable Strong Block) loose loose oose single grain 35-50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive ----35 loose loOSe single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive Comments: ######## Soil Log#2 E Boring ❑ Pit Elevation 949.0 Depth to SHWT 24 Inches Depth(in) Texture fragment°,o matrix color redox color consistence grade shape 0-8 Topsoil I0yr3'1 Loose Moderate Blocks 8-14 Sandy Loam 3r; 10yr4/3 Friable Strong itiod, 14-24 Sandy clay Loam 35 10.r3 4 Friable Strom, isiod.� 24-30 Sandy Loam 35 10yr5 3 10y4/8,1-6/10y Friable Strong Blocky 765 Lakeview Parkway Soil Log#3 E Boring ❑ Pit Elevation 946.1 Depth to SHWT 20 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-10 Topsoil <35 10\1-3 I Loose Moderate iii,,,,.\ 10-16 Sandy Loam <35 10yr4/3 Friable Strom Block I 0-20 Sandy clay Loam 10\1.5 4 Friable Strong Blocky 20-26 Sandy clay Loam <35 I 0. 1-5 3 10y4/8.I-6/l0y Friable Strom Block\ I hereby cerli j.thisylirk was completed in accordance with MN 7080 and am'local reqs. Rusty Olson's Soil & Perc. 810 Signature Company p Y I.icen,e 765 Lakeview Parkway Soil Log#4 Boring Pit Elevation 946.1 Depth to SHW'T 22 Inches Depth(in) Texture fragment matrix color redox color consistence grade shape 0-6 Topsoil 35 I U'r3 ? Loose Moderate Blocky 6-12 Loam 35 I O'r-1 3 Friable Strong Block 12-22 Clay Loam 35 I OyrS/4 Friable Strom Blocky -30 Clay Loam '35 10yr6/4 10y4/8,1-6/l0y Friable S1ronLI iii,„,, <35 loose loose single grain 35-50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive 765 Lakeview Parkway Soil Log#5 2 Boring ❑ Pit Elevation 949.0 Depth to SHWT' 22 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape O-I' Iopsuil <35 10yr3%I Loose Moderate Block\ 12-22 I 35 IOvr4 3 Friable Strong Blockv 22-30 Cla\ Loam - 35 I O\r; 1 10y4/8.1-6//10y Friable Strong Blocky loose loose <35 single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic plate rigid strong massive <35 loose loose single grain 35-50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive I herebti cert. - tis work was completed in accordance with MN 7080 and any local reqs. Rusty Olson's Soil & Pere. 810 esigner Signature Company License Soil Observation Log wAnv.SepticResource.com vers 12.4 Owner Information Property Owner%project: Gonyea homes Date 11/17/2017 Property Address I PID: 765 Lakeview Parkway Soil Survey Information ❑ refer to attached soil survey Parent matl's: Ti]Till Outwash li Lacustrine ❑Alluvium a Organic Bedrock landscape position: ❑ Summit J Shoulder ❑ Side slope ❑Toe slope soil survey map units: L41C2 slope 12-15 % direction- Linear-concave Soil Log#6 Boring ❑ Pit Elevation 949.0 Depth to SHWT 20 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-8 Topsoil Th- I nv r-; ' Loose Moderate Blocky 8-14 Loam • 35 10. r.i 3 Friable Strong I3l,,,kv I.1-.'.0 Clay Loam 3s 10yr5/4 Friable Strom_ Ih6ti�v 20-26 Clay Loam <35 I0yr4/4 10y4/8,1-6/10y Friable Strong kh,,..k\ <35 loose loose single grain friable weak granular blocky 35 -50 >50 firm moderate prismatic plat rigid strong massive Comments: Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 1 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-12 Topsoil 10yr3/1 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:45 1:15 6" 1.7 17.6 1:22 1:52 6" 1.6 18.7 1:53 2:23 6" 1.6 18.7 AVERAGE PERC. RATE 18.3 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 2 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-8 Topsoil 10yr311 8-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:46 1:16 6" 5.5 5.4 1:21 1:52 6" 5.5 5.4 1:54 2:23 6" 5.5 5.4 AVERAGE PERC. RATE - 5.4 MPI I - — Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 3 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-10 Topsoil 10yr3/1 10-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:47 1:17 6" 5.5 5.4 1:20 1:50 6" 5.5 5.4 1:55 2:25 6" 5.5 5.4 AVERAGE PERC. RATE - 5.4 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 4 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6 Topsoil 10yr3/1 6-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches I Time Time Depth Drop in H2O Perc Rate 12:48 1:18 6" 4.2 7.1 1:19 1:49 6" 4.1 7.3 1:56 2:26 6" 4.0 7.5 AVERAGE PERC. RATE 7.3 MPI ,e)4620-ei (7/1 v vit-E Oe e/ //lQ( 7LW Joseph Olson D.B.A. Rusty Olson's--Soil and Percolation Testing Joseph J. Olson--MPCA License#810 11481 Riverview Rd. NE, Hanover, MN 55341 (763) 498-8779 Fax (763) 498-8290 November 20.2017 Gonyea Homes 765 Lakeview Parkway Orono. Hennepin County This on-site Sewage Treatment System is designed for a Type I,five-bedroom home in accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. The periodically saturated soils were located at 20-24 inches(mottled soil). Due to the periodically saturated soils,a pressurized mound system with 6 inches of rock will need to be installed to treat the septic effluent. The bottom of the treatment area must be located at least 3' above the saturated soils. This system is designed with 6 inches of rock. The absorption areas of the two systems do not overlap. The soils at a depth of 12"have a percolation rate averaging 9.1 MPI. A 2250-gallon septic tank is designed for this site. All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs must be installed on the end of the laterals for maintenance. Use 7/32 inch perforations on the laterals. A Darwin 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device must be installed with light and sound devices;this is in case of a pump failure. A flow measurement device must be installed. Including but not limited to a water meter. event counter,running time clocks or electronically controlled dosing. Keen all heavy equipment off of the proposed treatment areas before,during and after construction. The area around both sites must be fenced off by the contractor before any construction begins. With proper installation and maintenance,this system should have no problem in treating septic effluent effectively. Nothing other than gray water,(laundry, showers.etc.)Human water and toilet tissue should be disposed of into the septic tanks.Garbage disposals are not recommended. Iron filters cannot eo into this system. Additives must not be used they may cause harmful damage to your septic system. It is recommended that you pump the septic tanks every two years. Sincere Joseph J. Olson J6 / R� oa/2 86S \ / Li' = -.0 /9s Sy,0 Oq ..>., r 11 '95-0 Q!Q<Be �` _. 1 33• 00/ � "_ . I Sg Ste, \ ,IQ J r {'H \ ` ' tea; ` el Irl t ♦. :9 7 it ' :A \111/00411 b. r . 1 a.D 0 i1,\��9 Illgibe- \ -,L• '48• �',.. ,, iI F1.'4 S T iTl \ `V BLOCK ' -.- ,� - .. ` V •p \\\ c 4 f ` LOT f '' "`1 )r N a 0.4 A,s'' ' *6i / ` ..i".. f 1 1 0 0 s$9 os„N f 803q N83.04'38"E 109.25 • •; i7 •• JO 1)(1,3 ` Yb -%."),)••• MI ,% °!v Ecol Mak 'Rio !lilt - ' • • g`tr.v. ii _iropii _.,,,,., ..r7.Dt ,•1_, „, st ...I.E.L, inci _j 9 3 9 0`rte - I, ,?-1-g-5 MAW . VOW Ng sow sE LMA so • 1414 X 134,-) ? e ona rar ,es Mauch... �`'�� 6,414 E a3' . • SOIL BOSS ti G ELEVATIONS MOUND SYSTEM DESIGN ; o Type_ _•_-`�Bedroom,Average percolation rate `, e ' i` TKO - / $F :nest be: THat4 EL..2!,‘...1 7sv gal/day _ C,,3o stilt.of treatment area&3 (/10 ft. width= /a ft.length of bed area Tang -'ban p rty tines • AS EL-1/2 0 la:• 4/6 19.....2, Side slope ruri3 -- to 1 x height= ft.x8` ft.Lawn area. .L•.+ Clean rock neededplus 20% / T arm•— i cu_yds.Coarse washed sand3cu.Yds.Average sand depth /.8' ent area,a..*fres Ilicceitif all* ik Sandy loam / cu.yds.,Topsoil b" 7,: cu. s. cu.Yds. 6 as yd plus 50% As.'from Wax Number of tanks / ,1"tank;:,dtgals.,god tank gals-,Pump chamber capacity 13uv gals. PRp R F gals./100 lineal feet of 2"dia-Supply pipe,ansa!feet needed 2 . &AILS /( "� •• r- • •, Distribution pipe� "dia. (`' lineal feet, ,/.2 r dia.Perforations -31., A apace Float set at ' gals., -1 times per day Pump curve 3i0 /min_ A feet head pressure. Date:4fie.j ;- Ph. 763-498-8179 Rusti.01.01116 and Pera olatb Test Oesi i 'E .- 2011 purple code Mound Design www.SepticResource.com (vers 15.2) Property Owner: Gonyea Homes Date: 11/20/2017 Site Address: 765 Lakeview Parkway PID: 0611723340010 Comments: instructions: = enter data =adjust if desired = computer calculated - DO NOT CHANGE! 5 bedroom Type I Residential System 750 GPD design flow Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks -t) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) Tank options: none 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed 10.0 ft rockbed width 63.0 ft rockbed length 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) end feed manifold connection 81 3 laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total (1/2 a perf means the first perf starts at the middle feed manifold) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation for this perf size a spacing, a pipe size on line 12, max perfs/lateral = 30 , line#8 must be less --> OK dui 4.0 doses per day (4 minimum) i ) 188 gallons per dose (treatment volume) 2.00 5x 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement 2.00 3x l 3, 97 feet of 2.0 inch supply tine leads to 16 gallons of drainback volume (Tip: "top feed"manifold to control the drainback) 14 204 gallons TOTAL pump out volume (treatment+ drainback) 15) 17 feet vertical lift from pump to mound laterals, leads to a: 166, 36 GPM® 27 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) 17) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi leads to a 18) 8.0 inch swing on Demand float, or timed dosing of 5.7 min ON (confirm pump rate with drawdown (this delivers Average flow, =70%of Peak design flow) 9 hrs OFF test and adjust as necessary) 19 12 inches from bottom of tank to"Pump OFF"float 2uw 20 inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed 21) 23 inches from bottom of tank to"Hi Level"float, or 33 inches to"Hi Level"float if time dosed 22) 714 gallons reserve capacity (after High Level Alarm is activated) 23, 0.45 gpd/ft1 Absorption area Soil Loading Rate, which gives a mound ratio of 2.7 (minimum) (this must match the soil boring log) desired mound ratio 2.7 24, 12 percent site slope (0-20% range) 12 (%downslope site slope,pe, if different than upslope) 22 inches, or 1.8 ft. to Redox or other limiting condition (need at least 12"to be a Type I) Treatment zone contains 0 inches of 0%soil credit, and 0 inches of 50%soil credit. Giving a: 20) 14 inch, or 1.2 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONS!!! 27 27.0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:) 2s) 0.0 ft. upslope and sideslope 17.0 ft. Downslope Individual slope ratios give BERM widths (topsoil beyond rockbed)of: 29, 4:1 upslope ratio 9 ft. upslope berm 30, 3:1 sideslope 13 ft. sideslope berms 311 3:1 downslope 27 ft. downslope berm 32 Overall Dimensions: 10.0 ft. wide by 63.0 ft. long Rock bed 46 ft. wide by 89 ft. long Mound footprint 4" inspection pipe 18" cover on top <Upsiope berm 9 ) Downslope Downslope berm 27 } M 12" cover on sides (6"loamy cap&6"topsoil) 1.2 Clean sand lift _ I 1.8 I Depth to Limiting limiting Conjitlon _— -- ---- _..--n.- -- ---- ( Absorption Width 27.0 — Note: For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. 33, Rock Bed: 10.0 ft. by 63.0 ft. by 6 inches under pipe, plus 20%gives 21 yd'or*1.4= 29 ton 14 Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) 19.0 up + 81.7 downslope + 12.6 ends + 41.2 under rock = 235 yd'or*1.4= 329 ton plus 20% 5) Loamy Cap: 42 ft. by 85 ft. 6"deep, plus 20%gives 88 yd'or*1.4= 123 ton 30, Topsoil: 46 ft. by 89 ft. 6"deep, plus 20%gives 91 yd'or*1.4= 127 ton I hereby certify that I have completed this work in accordance with all applicable ordinances, rules and laws. Rusty Olson"s Soil Et Perc 810 11/20/2017 signer Signature Company License# Date Installer Summary 2250 gallon Septic tank (minimum) Tank options: none 7U7o larger Lank WIln rnulipte Lump/LaRKS 1300 gallon Dose tank (minimum) at 25.49 gpi 36 GPM® 27 ft. of head, Pump required 8.0 inch swing on Demand float which translates to roughly 5.0 inches of float tether length if time dosing is required --> 5.7 minutes ON time Ft 9 hours OFF time 20 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float 23 inches from bottom of tank to "Hi Level Alarm"or 33 inches to "Hi level alarm" if time dosed 97 ft. of 2.0 inch supply lin€ with end feed manifold connection (Tip: "top feed"manifold to control drainback) 14 inch, or 1.2 ft. Sand Lift Mound 10.0 ft. wide by 63.0 ft. tong Rock bed 3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing 7/32 inch perfs 3.0 ft. perforation spacing No Effluent filter 8 alarm 3 clean out a valve box assemblies 27.0 ft.Total sand ABSORPTION width (minimum) 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) 17.0 ft. Downslope (sand beyond rockbed, minimum) Specific slope ratios give BERM widths (topsoil beyond rockbed) of: 4:1 upslope ratio 9 ft. upslope berm 3:1 sideslope 13 ft. sideslope berms 3:1 downslope 27 ft. downslope berm 4" inspection pipe 18" cover on top {Upstope berm 9 Downslope berm 27 12" cover on sides (6"loamy cap&6"topsoil) 1.2 Clean sand lift 1.8 Depth to Limiting Lin- —w—._ ,_ rr,� ConditTun— —-_—.__.._ _, __ __ Absorption Width 127.0 1 —— _.—- Note: For 0 to 1%slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. Rock Bed: 21.0 yd3 or*1.4= 29 ton 6 inches under pipe Mound Sand: 235 yd3 or*1.4= 329 ton calculation based on 3:1/4:1 slope from top of rockbe, Loamy Cap: 88 yd3 or*1.4= 123 ton 6"deep Topsoil: 91 yd3 or*1.4= 127 ton 6"deep INSPECTOR CHECKLIST - mound /65 Lakeview Parkway VV F.1.I. setbacks: 20'to pressure tested sewer line (5 psi for 15 min) 50'to everything 100'to dispersal area with shallow well PROPER Y LINES setback: 10'to everything Road setback: platted: 10'prop line. Metes & bounds: out of road easement, or outer ditch. LAKE 131,l`FF setback: 20'for bluff. Lakes: GD_, RD , NE_. Protected wetland Building setbacks: 10'for everything, 20'for dispersal area. WA II.R LINE under pressure s.10'to bed,tank & sewer line. (else sewer line > 12" below) nSewer line & baffle connection (no 90's, 3'between 45's, slope min 1" in 8', max 2" in 8') (no depth reqs, clean out every 100', Sch 40 pipe) riSeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) mfg 2250 gallons none Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. _ No effluent filter & alarm Dose tank risers and piping (water tight, insulated, proper depth, drainback) mfg 1300 gallons n dose pump 36 gpm 27 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF n float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length 204.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected LABEL pump requirements and drawdown on riser or panel Cam lock reachable from grade - 30" max. J-hook weep hole. Supply line access (no hard 90's) 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. _ splice box / control panel / electrical connections flow measurement: CT, ETM, time dosed, home water meter mound absorption area rough up _ mound rock dimensions 10.0 X 63.0 Sand lift depth 14 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) nAbsorption Sand beyond rock 0.0 upslope 17.0 downslope Bermed topsoil beyond rockbed 9 upslope 13 sideslope 27 downslope cover depth of 12-18"+ VERIFY 3 laterals (1-2'from edge of rock) 2.00 inch pipe size (Sch40 pipe &fittings) 3.0 ft lateral spacing 7/32 inch perforations • 3.0 ft perforation spacing Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY clean outs (no hard 90's) 4"inspection pipe to bottom of rock, anchored VERIFY Abandon existing system - if necessary Re-use existing tank certification monitoring plan and type well abandonment form - if necessary 1 _ 1 v iia.v !tiar_1rA. System Elevations t t ,,,, ‘ ,}_i • benchmark I _ SHWT Mound 7 (Grade elevations are existing. If a loamy cap different final grade is desired it should lateral be shown and described here.) bottom rock grade (at upslope rock bed) SHWT (at upslope rock bed) :?;.!:____, _....14,4NAIALLANAILietNA16AWA,41u4 4 W aAJAMa..•�,yray„�yu1rMAVAbuAi tiMAA INA.th h iciok-::AA.../u mm, .... L / - f--, -I, si -1, , , i 1 1 1 7 C7 Sewer pipe 7 7 7 exiting house Septic Tank Septic Tank (►r applicable) Pump Tank Grade Grade Grade Grade Pipe inlet inlet inlet Tank bottom Tank bottom Tank bottom Soil Observation Log IA NV W.SepticResource.com vers 12.4 Owner Information Property Owner/project: Gonyea Homes Date 11/17/2017 Property Address/PID: 765 Lakeview Parkway Soil Survey Information ❑ refer to attached soil survey Parent matl's: E]Till ❑ Outwash ❑ Lacustrine ❑Alluvium ❑ Organic ❑ Bedrock landscape position: E Summit ❑ Shoulder 0 Side slope ❑ Toe slope soil survey map units: L41 C'2 slope 12-15 % direction- Linear-conca\e Soil Log#1 [' Boring ❑ Pit Elevation 949.0 Depth to SHWT 22 Inches Depth(in) Texture fragment°, matrix color redox color consistence grade shape t1-12 l opsoil 35 I(h r3 I Loose Moderate Blocky I2-22 I,oam <35 I(h r-1 : Friable Strove, Blocky 22-3() Clay Loam <35 lOcr5'4 10y4/8,I-6/I Oy Friable Stroma Blocky <35 loose loose single grain 35-50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive Comments: ######## Soil Log#2 0 Boring ❑ Pit Elevation 949.0 Depth to SHWT 24 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-8 Topsoil <35 1(1�r; I Loose Moderate Blocks S-14 Sandy Loam —; I Oa r4 I riahle Strong Blocky 14-T_4 Sandy clay Loam - _ 10 r3 4 Friable Strong I I- a Sandy Loam - I O' r5 3 10y4/8,1-6110y Friable Stroll Blocky 765 Lakeview Parkway Soil Lou #3 2 Boring ❑ Pit Elevation 946.1 Depth to SHWT 20 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-10 Topsoil <35 10yr3/1 Loose Moderate iii,,,=, Iii-I c Sandy Loam 35 10yr4/3 Friable Strong Blocky 16-20 Sandy clay Loam 35 10yr5/4 Friable Strong Blocky 20-26 Sandy clay Loam 35 10yrS 3 I0y4i8,1-6/10y Friable Strom mock\ I hereby cert/ this�}yvrk was completed in accordance with MN 7080 and any local reqs. Defl l Rusty Olson's Soil & Pere. 810 gne'rSignature Company License# 765 Lakeview Parkway Soil Log#4 Boring ❑ Pit Elevation 946.1 Depth to SHWT 22 Inches Depth(in) Texture fragment 00 matrix color redox color consistence grade shape 0-6 Topsoil 35 10y r; 2 Loose Moderate Blocky 6-12 Loam 35 I(Iv rt 3 Friable Strong Blocky 12-22 Clay Loam 35 10. r5 I Friable Strong l3I,,.. 22-30 Clay Loam 35 I0yr6/4 I 0y4/8.1-6/I Oy Friable Strong iii„c:.\ - 35 loose loose single grain friable weak granular blocky 35 -50 0 firm moderate prismatic platy rigid strong massive 765 Lakeview Parkway Soil Log#5 0 Boring E Pit Elevation 949.0 Depth to SHWT 22 Inches Depth(in) Texture fragment°ro matrix color redox color consistence grade shape n-I_' Topsoil 35 10yr3/I Loose Moderate iiI,,d:', 12-22 Loam 35 10yr4/3 Friable Strong Bl,,cl.� 22-30 Clay Loam 35 10\r5 1 10y4/8.1-6;10y Friable Strong Block> <35 loose loose single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive /hereby cert. is work was completed in accordance with MN 7080 and any local req'.r. Rusty Olson's Soil & Perc. 810 esigner Signature Company License 4 Soil Observation Log wcva.SepticRcsource.com vers 12.4 Owner Information Property Owner/project: Gonyea Homes Date 11/17/2017 Property Address/ND: 765 Lakeview Parkway Soil Survey Information L-1 refer to attached soil survey Parent matl's: Q Till J Outwash ❑ Lacustrine ❑Alluvium Organic E Bedrock landscape position: ❑ Summit ❑Shoulder 2 Side slope ❑Toe slope soil survey map units: L41C2 slope 12-15 % direction- Linear-concave Soil Log#6 Boring E Pit Elevation 949.0 Depth to SHWT 20 Inches Depth(in) Texture fragment°i° matrix color redox color consistence grade shape u-S Topsoil <35 10yr, Loose Moderate Blocky 8-14 Loam • 35 I 0yr4/3 Friable Strong Blocky I41-_o Clay Loam <35 10yr5!4 Friable Strong iii.,�:.� 20-26 Clay Loam l0yr4/4 10x4.'8,1-6/10y Friable Strong i;i,,,>, <35 loose loose single grain 35-50 friable weak granular block) >50 firm moderate prismatic plat) rigid strong massive Comments: Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 1 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-12 Topsoil 10yr3/1 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:45 1:15 6" 1.7 17.6 1:22 1:52 6" 1.6 18.7 1:53 2:23 6" 1.6 18.7 AVERAGE PERC. RATE 18.3 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 2 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-8 Topsoil 10yr3/1 8-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:46 1:16 6" 5.5 5.4 1:21 1:52 6" 5.5 5.4 1:54 2:23 6" 5.5 5.4 AVERAGE PERC. RATE 5.4 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 3 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole 6"_inches. Soil data from test hole: Depth, inches Soil texture 0-10 Topsoil 10yr3/1 10-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:47 1:17 6" 5.5 5.4 1:20 1:50 6" 5.5 5.4 1:55 2:25 6" 5.5 5.4 AVERAGE PERC. RATE - 5.4 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 12:35 P.M. On 11/18/17 Location: 765 Lakeview Parkway Hole number: 4 Date hole was prepared: 11/17/17 Depth of hole bottom_12"_inches, Diameter of hole 6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6 Topsoil 10yr3/1 6-12 Loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 11/17/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 12:48 1:18 6" 4.2 7.1 1:19 1:49 6" 4.1 7.3 1:56 2:26 6" 4.0 7.5 - AVERAGE PERC. RATE 7.3 MPI - 1- DATE TIME CITY OF ORONO CALLED IN INSPECTION NOTICE SCHEDULED I /a:00 PERMIT NO. 2C(7 C 1EY!Q -COMPLETED Pv ADDRESS 7& � iI�'�� 40 OWNER TELEPHONE N . ���_��� ���5 CONTRACTOR 7-671-y �^ � DESCRIPTION W ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL ❑ POURED WALL 0 PLUMBING RI 0 EXCAV/GRADING/FILLING • ❑ FOUNDATION DRAIN TILE 0 PLUMBING FINAL 0 TREE REMOVAL Z• ❑ LATHE 0 MECHANICAL RI ❑ SITE INSPECTION C 0 FRAMING 0 MECHANICAL FINAL 0 RATED WALLS • ❑ INSULATION 0 WOOD BURNER/FIREPLACE 0 COMPLAINT Q 0 FINAL 0 WATER HOOK-UP 0 FOLLOW-UP i 0 AS BUILT-SURVEY 0 SEWER HOOK-UP 0 FOUNDATION/REMOVAL . ❑ DEMO-SITE 0 SEPTIC INSTALL IC OWNER/CONTRACTOR TO MEET YOU:_YES_NO • COMMENTS: 7;27—;/ re-4-1 t.'dh t•5c c) /,r Set-17A ckf CC • ! a b pa4 cS gDlad t✓l Ay/Scrtr G 1 I iviS et �h ci pads pa.r 1-4 go, 4 oh Ptah► Ge4.t�'S1� cc l.✓J All (t-etj 1\I- p 1r Ge r `i t0 hop.( a/ol= a h C,Se. L ('i SP art- Ca A•e-7-" Luz z cc W %WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY ✓ BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. U PHOTO TAKEN INSPECTOR WILL RETURN El El STOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED O INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: Inspector: White Copyllnspector's File Canary CopylSite Notice DAT _ 8 TIME CITY OF ORONO CALLED IN INSPECTION NOTICE "]� SCHEDULED / - – //.'g PERMIT NO. a 0/7'a&v COMPLETED(" ADDRESS 705te0/e'" ) ,° i OWNERELEPHONE NO. "'F'� 4r5 CONTRACTOR n DESCRIPTION f L4iY?d Irl/ ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL Q/ OURED WALL 0 PLUMBING RI 0 EXCAV/GRADING/FILLING Q ❑ FOUNDATION_ DRAIN TILE 0 PLUMBING FINAL 0 TREE REMOVAL ❑ LATHE 0 MECHANICAL RI 0 SITE INSPECTION Q 0 FRAMING 0 MECHANICAL FINAL 0 RATED WALLS ❑ INSULATION 0 WOOD BURNER/FIREPLACE 0 COMPLAINT Q 0 FINAL 0 WATER HOOK-UP 0 FOLLOW-UP W ❑ AS BUILT-SURVEY 0 SEWER HOOK-UP 0 FOUNDATION/REMOVAL , ❑ DEMO-SITE 0 SEPTIC INSTALL <--- OWNER/CONTRACTOR TO MEET YOU:_YES_NO a r.) COMMENTS: e: Q. RC/140,- — foci Ge.6 ;417,, .4. 1/44,1 .._tt .z a S6r4ct<ccr,LL aK ptaK -- c f h •S k r'Q4a r 4- -s p�/iddrt— c Q W z e.E r rfc 4- O,k- -in ...._ CC a Lu ❑WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE CC W CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O 0 RECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: Inspector. <01ham. White Copy/Inspector's File Canary Copy/Site Notice DATE TIME V CITY OF ORONO CALLED IN INSPECTION NOTICE , SCHEDULED 2- 5 -/F- /:c-O PERMIT NO. �G17 --- i iL 1 �0 COMPLETED ADDRESS 76)5 L_<c.-k-Ct,'r`e-L. 0-,___,'k:3 r;-_y OWNER .NO.(/2 7y&-/ 9 CONTRACTOR £ &i7/ E A63__ DESCRIPTION le:'ZK:J'w'' t W ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL Q ❑ POURED WALL 0 PLUMBING RI 0 EXCAV/GRADING/FILLING Q ❑ FOUNDATION DRAIN TILE 0 PLUMBING FINAL 0 TREE REMOVAL ❑ LATHE 0 MECHANICAL RI 0 SITE INSPECTION Q 0 FRAMING 0 MECHANICAL FINAL 0 RATED WALLS ❑ INSULATION 0 WOOD BURNER/FIREPLACE 0 COMPLAINT Q ❑ FINAL 0 WATER HOOK-UP 0 FOLLOW-UP 41 0 AS BUILT-SURVEY 0 SEWER HOOK-UP 0 FOUNDATION/REMOVAL v ❑ DEMO-SITE 0 SEPTIC INSTALL .C.- OWNER/CONTRACTOR TO MEET YOU: YES_NO COMMENTS: ou. 4w n, s y�v� rlve�- 2 -/,-ewe, W 4A.o Par.4.f,4 0.4 harpy /46&1,c.1- wi cc d r. ,,,, &►?.e -v 4 0 Q 9froise ,A- O. sA-)e w 4eK- Ate-k4 17 .0 e4d. W Z cc GcW►f✓Cc *6 OK 16 rvr/e•i a W ❑WORK SATISFACTORY:PROCEED ❑PROJECT COMPLETE CCW _RRECT WORK&PROCEED El ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY OV BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN O STOP ORDER POSTED.CALL INSPECTOR CI CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on ,site: Inspector. 91,;, 7P White Copy/Inspector's File Canary Copy/Site Notice MINNEHAHA CREEK -'� WATERSHED DISTRICT QUALITY OF WATER QUALITY OF LIFE Pursuant to Minnesota Statutes Chapter 103D, and on the basis of statements and information contained in the permit application, correspondence, plans, maps, and all other supporting data submitted by the applicant, and made a part hereof by reference, PERMISSION IS HEREBY GRANTED to the applicant named below for use and development of land in the Minnehaha Creek Watershed District. 2O1 - O)Clof 0 Issued to: Gonyea Homes Permit No: 18-012 Location: 765 Lakeview Parkway, Orono Purpose: Erosion Control- Single family home Date of Issuance: 2/9/2018 Date of Expiration: 2/9/2019 By Order of the Board of Managers Eliza eth Showalter Permitting Technician This permit is not transferable without District approval, and is valid to the date of expiration. No activity is authorized beyond the expiration date. If the permittee requires more time to complete the project, an application for renewal of the permit must be received by the District at least 30 days before expiration. The applicant is responsible for compliance with all District Rules and for the action of their representatives, contractors, and employees. Conditions: Project to be completed as described in plans submitted to the MCWD office on February 7th, 2018 according to the provisions of this permit. • Properly install and maintain all required erosion control measures until the disturbed areas are re-stabilized • Notify MCWD in writing upon completing installation of perimeter and sedimentation controls • When the site is re-stabilized and the MCWD staff has performed a final inspection, all perimeter control must be removed (Statement concerning fees for inspections, violations, etc... on following page) We collaborate with public and private partners to protect and improve land and water for current and future generations. 15320 Minnetonka Boulevard,Minnetonka,MN 55345 • (952)471-0590 • Fax:(952)471-0682 • www.minnehahacreek.org MINNEHAHA CREEK WATERSHED DISTRICT QUALITY OF WATER QUALITY OF LIFE Inspection/Analysis/Monitoring Fees A site inspection and monitoring by District staff will be performed where the activity involves: • a commercial/industrial/multi-family residential development • a single family residential development greater than 5 acres or of any size if within the Minnehaha Creek subwatershed • any alteration of a floodplain or wetland • dredging within the beds, banks or shores of any protected water or wetland • a violation • any project which in the judgment of the District staff should be inspected due to project location, scope, or construction techniques In these cases, the applicant shall pay to the District a fee equal to the actual costs of field inspection of the work, including investigation of the area affected by the work, analysis of the work, and any subsequent monitoring of the work, which in the case of a violation shall be at least $35. Standard Fee Schedule District professional staff $ 65.51* District interns $ 40.35* District clerical staff $ 46.69* Consulting Senior Engineer $ contracted rate Consulting Engineer/Technician $ contracted rate District Counsel $ contracted rate Application fee $ 10.00 Copy costs $ .25 + actual staff time Color copy costs $ 1.00 + actual staff time * Hourly We collaborate with public and private partners to protect and improve land and water for current and future generations. 15320 Minnetonka Boulevard,Minnetonka,MN 55345 • (952)471-0590 • Fax:(952)471-0682 • www.minnehahacreek.org / ' i.'",- f • DESCRIPTION OF PROPERTY SURVEYED i SIT,�p r;�\� /r r LOT - / Lot I,Block 2,LAKEVIEW OF ORONO,according to the recorded plat thereat Hennepin County,Minnesota Oaf e� j� \ \ 1) Site Address:765 Lakeview Parkway,Onmo,Minnesota,55364 v I of \ ' x t>6.7 \N \f,�\ r r `?�. \ / / 2) Flood Zone Information:This property appears to lie in Zone X(Area determined to he outside the 0.2%annual chance / aBEI te\\ \Oils \r r "mss r t,4.V� ^ floodplain)per Flood Insurance Rate Map,Community Panel No.27053CO285F,effective date of November 4th,2016. \� &\ N \ r \\ N v &its.3 3) Parcel Area Information: Gross Area: 107,929 s.f. -2.48 acres / \ \ ` N zSt� / 4) Benchmark:Elevations are based on development Benchmark located Lots 1/2,Block 2,LAKE VIEW OF ORONO,which has '' \ N.\ \ \\ OI O)� \ m elevation of:%1.48(NGVD29). / - ` i. `\ 'v\ 9 jam_ 5) Zoning Ioformatlon:The cuneot Zoning for the subject property is LR-IA(One Family Lakeshore Residential-2 ALm)per .92 \\ \ \ YI�Cl'S ``/� BLOCK J / the Cityof Orom'a zoning map dated September 2016.The setback,height,and Door space stn reaniebons for said tuning N 1 -\' b433.7\ \ G•r' ` de ignation were obtained from the City of Orono found on thea web site m the date of October 31st,2017 and am as CoBows: rs _ 1 9u1 \\ \ \ \ \ I�)._ / 11'\1- DR, & \. \ AY Principal Structure 5etbacb-From.50 feet(Lakeview Park-any) -J/ N N �,�'UTILITY EASEMENT \ '�\ ' \ A-4} N LOT 5 side:1 o feet feet / ` `�yr+��/`.' Rear.t: 0 N\ri r i N L 9A.�) \ \\ �` 'Y� / Height:30 feet \ \ D7co '\\\ \ �• \ Hardcover.35 percent of lot area pa Tier 3 Stonnwater Quality Overlay District Map /N 1 \ e 9}19 093+3 \\ \ / ,` ST-/-\_-_SBS.1�7'Sg•E me.97 I a ask, II\' \ .. / LOT r Please note that the general restrictions foe the subject property may bare been amended through a city process.We could be I 1 1'___L__ i� unaware of such amendments if they are not in a recorded document provided to us. We recommend that a zoning letter be \\ Jy�^` \\ /�/ / , \ \ir \\ \N \ obtained from the Zoning Administrator for the current restrictions for this site. Ark E--- ac'x ( / l sn.a \ '\ A \ RO I 6) Utilities:We have shown the location of utilities on the surveyed property by observed evidence only.There may be \ 9738 1 r / \ I a ?� _� �� / underground utilities encumbering the subject properly we are unaware.Please note that we have not placed a Gopher State One I \ \ /33.4P° I �� Call for this survey.There may or may not be underground utilities in the mapped area,therefore extreme caution must be exercise before excavation takes lace on or near this site.Before digging, u are \ li I.Re _ fr \ \ \ B� r any P 88 B.Yo required by law to notify Gopher State I I 1 r �// / seat '• One Lill at least 48 hours en advance at 651/434 0002. n,,rt tar B \ ,t. _CONSFRVATI I _,�r r (1 -`7 / / \/ . I LI, V - vvrr..vt401 \p / t, _ \ EASEMENT 1-== _ jl , \ , . 1j�:�:: --M i ' ' P _7� - �� J�_\\ Proposed Elevations 1 - ,� _''S5 7 a- V 1- Proposed Garage Floor Elevation =949.9 111 11 1 \1 \ \\ ` l I `\ `.�,..,...k rti\' V.4.., \. \ I.a \\ �� �_ Proposed First Floor Elevation =952.4 1 x yg� 1' Proposed Top of Foundation Elevation a 950.2 V \ \� \ \ I\ i 1% j pas P oposed Basement Floor Elevation =941.5 1 1 \ I (- •sore to 1 \ b l i 1 1.-.4,, 1 1 1 9\�\ \\ \\ I I x .� \�1 \li `'sus/ ORsetIrons m 11 1 act 1 \\1 • '\ pn2 TE I-„-/ px A- \ 1 l S`'-J (CleratlpM are to the top of pipe) I OSFI-94'_.23 OS 42-94321 • tIt 1 1x9311.: \ \ \I \ A) \Ir,,.1 OSo4-94815 OS t,3 943.99 \ OS as-944.78 OS A6-942.99 .N 11 1 \ \l WI 'I ' `% _ - 'i �2+ 11 a °5e OS 2849!1.46 OS 97 944 96 l 1 1 \ zI 1 A 1 {�-.4t v \„ l/ 8 ^ { 3/ \ // \ Asbuilt Elevations 11 II 11 z� 1 SEP D� $I� it _I --_ A,buiN fiusge Fbx,r Ekvuu.n =V19 5r0.3-949.5lir)T FO1JREDI 1 I 11 Y t I --.ter 7 FAC[ :Staudt Top of Foundauon Elc,,mm =4 950.1 1 I ` I \ 959.5 A,buih Raacnlcm li v,r Flcs anon -941 110 33-941 9 IN0T P01.2510: 1 /I IP. \'', i - \ (,.93s.nsu �- SO 1 I '0 / o a H T. f•*,'. . I 1&1) . r - 1 � I I \ BLOCK 2 I II °- ` �0' _ • 1 ,y to ` a ^' /I!\ Zr x953x s� 9' 1 LOT I I I I x9110.4 w ; 1 \ \ 1 ><ri° �= \ c .1 I LOT 2 \ ID x I I 1320 \• ,�:=.` sm* to o, , �'aiR4115 0 ._. \ Ole I I yly{oA)4. 4'. d o ; .. n \\ \ I I (i I 'e;-- \ d'?wasy�,:; .v ere /�W \ . \\ I I I I a �''�_ 2pe�f' � N rT11� o • Ko \ __- EASEMFrNT�l(•_-I i -- ` i `r4), ..o.... ,,,as4'75 1 `\ II 1 1 .903. 'pg - 1 1 ... '� ` 1 I I 1 -\dor s:°'� C, ':.r•L4' . ) I/¢ N 1, 1 1, \ i I I \ I yL 1� 4t;° -- \ ; , I via' Ts clew r''', I a r ‘ --.' __. �6-r-( \ I I I 'err e,4 MIAS _ N i //f 'a - \ I 1 ,VIIs 940.7 x031. .y I \ I , �»-\ vis ,4 sir 30 15 0 15 30 60 OUTLOT G2.,. \ 1 I,\\ I,' I ----940--91-7 �-iv +\i`�e x 9505 \ SCALE IN FEET II I \\ \ \ \gym}'/ /^ ---s \ •Tk �`\ SURVEY LEGEND \ I` r _ -- -- -- - \ M/�to x941, (B CAST IRON MONLNENT ® A/C UNIT \\' � 1 \ ---f -.:.7_-7-7 7'04 36'W 122.29....-- \r \\ / CAT01 BASS B'3 CABLE TV PEDESTAL CABLE SETBACK UNE \ I „, Fr 1 .525.3\a, - \ a FLARED END sEction m ELECTRIC TRANSFORMER -otv- I I \ \�` rv� f \ `� PC GATE VALVE m ELECTRIC MANHOLE - \ \ �c-- I - \/ a GUY'WIRE m ELECTRIC METER 1..-, I CONCRETE CURB I --9-_ a 0150CONCRETE -_,CONSERVATION \ I \ cf_________� XF HYDRANT 0 GAS METER -No_ CONTOUR EXISTING EASEMENT \ \` \ O SAVE'MONUMENT SET t0 GAS VALVE ----1210... .--CONTOUR PROPOSED 5 \ ,, \•9 z/ s 93Aa' \ I • SURVEY MONUMENT FOUND GUARD RAE -m- 5\......",./........ ' •-•••• x93!.3 / -, \ Q SU(VEY CONTROL PONT ® HAND HOLE -Be-aEct TIME QECTRO UNDERGROUND `51st -a-a-/s 9+51 0 sea T POLE SOL BORING FENCE _-- TREE CONIFEROUS -en-FIBER OPTIC UNDERGROUND Z -7P \ run POWER POLE -aAs-GAS UNDERGROUND `�8 }d`�.7 \ ___ SAMTARY MANHOLE TREE OECIDU0115 3ef -T 60,E - N83.O4'38"E 109-Z,5/ \ 0 SAMTARY CLEANOUT TELEPHONE MANHOLE -0111-OVERHEAD UTILITY _ -"' ,Er a yGN [Ti TELEPHONE PEDESTAL 1NNiNSHTNNN RAILROAD TRACKS \-yKy---_ ,- x9$.9\ nt1(RIXNO DJ:VAnOLI ate-TRAFFIC SIGNAL =;-SANITARY SEWER �/ _ WET tar m tar ULT ® STOtaI DRAW 0 U11UTY RANKLE ER -to-TELEPHOSTORM NE UNDERGROUND -- -- '9319 V V I L.V 1 B 11¢7 *W1t \ ® STORM MANHOLE D Uf1UTY PEDESTAL -_ '1331 0 YARD UOLIT 9 WELL 1m-I7TILITY UJDERGRWNO -� -I-WATERMAIN FIELD CREW NO. BY DATE REVISION USE(INCLUDING COPYING.DLsTRmUuON.AMOR 1 hereby certify that this survey,plan or report aas prepared by the or under ray direct nymvisianad that I on a duly Licensed T WP.117-RGE.23-SEC.07 AIRS I GIN Mme rwwwnosc. i CONVEYANCE OF NFORMARON)OF THIS PRODUCT IS Land Surveyor under the laws of the Sate ofMimaon. FILE NO. STRICTLY PROHIBITED WITHOUT SATlwsBERGOUIST. ,E"s a`'AL Project°m':°r°"° CERTIFICATE O F SURVEY DRAWN s oar 7.x,11 IMMO PM Ott COMMA, INC.'.EMPRESS WRITTEN AUTHORIZATION.USE Dated t s 8th day of November,2017. =ti? Po Hennepin Coe* 37202-032 BAY WITHOUT SAID AUTHORIZATION CONSTRUTE3AN FOUNDATION ASBURT SATHRE-BERGQUIST INC. CHECKED ILLEGITIMATE USE ANO SHALL THEREBY NOEMMFY L.,..., W Jef " r9117HaE-0ERODUIST.NC.OF AU RESPONSISIUTY. PREPARED FOR: 150 SOUTH BROADWAY WAYZATA,MN.55391 (952)47643000 Lakeview DBP ' SATHRE-SERGOUIST,INC.RESERVES THE RIGHT TO _ , .' �HOLD ANY IIAEGITRMTE USER OR PARTY LEGALLY .� i" Parkway GONYEA HOMES DATE RESPONSIBLE FOR DAMAGES OR LOSSES RESULTING David D.Parabola¢PLS Minnesota License No.40344 1 052517 FROM¢LEGITMATE USE perttonon®satrecam OyF4s I, Christine Mattson From: Christine Mattson Sent: Monday, February 05, 2018 9:01 AM To: 'Nate Mitchell' Cc: Roger Peitso; Monica Fadness; Nola Dickhausen Subject: RE: 765 Lakeview Parkway/#2017-01610 Hi Nate, We have received and approved an electronic copy of the foundation as-built survey. You may keep your backfill/waterproofing inspection scheduled for this afternoon. A copy of this email authorizing you to proceed should be kept on site with the inspection card. Please note: In the future, a minimum of 24 hours is required for review the foundation as-built surveys. Also, please provide us with a full-size paper copy of the foundation as-built survey for our records. Don't hesitate to contact me if you have any questions. Christine Mattson Planning Assistant City of Orono 2750 Kelley Parkway Orono MN 55356 (physical address) PO Box 66 Crystal Bay MN 55323-0066 (mailing address) 1ir 952.249.4620 8 952.249.4616 gq(Al-Cd - Civ cmattson@ci.orono.mn.us www.ci.orono.mn.us Office Hours: Monday- Friday 8 am to 4:30 pm mum( aLuNnic, L_ OUR OFFICE WILL BE CLOSED: Monday, February 19,2018 C0i01 ► ` 5h'tQk 2 .2.2.. 0( From: Nate Mitchell [mailto:nmitchell@gonyeahomes.com] Sent: Monday, February 05, 2018 8:01 AM To:Christine Mattson<CMattson@ci.orono.mn.us> Subject: Fwd: 765 Lakeview Hello, Attached is our prevackfill as-built survey Thank you Nate Mitchell 1 Project Manager 612.940.1604 (mobile) From: Bryan Voit<Bvoit@sathre.com> Sent: Monday, February 5, 2018 7:54:44 AM To: Nate Mitchell Cc:Jon Connolly Subject: RE:765 Lakeview Nate, Attached is the PDF of the foundation asbuilt. From: Nate Mitchell [mailto:nmitchell@gonyeahomes.com] Sent:Thursday, February 01, 2018 11:43 AM To: Bryan Voit<Bvoit@sathre.com> Subject:765 Lakeview Bryan Orono requires prebackfill as built. Can you do this tomorrow and send over as soon as you can. Thanks Nate Mitchell Project Manager 612.940.1604 (mobile) 2 • / '' ,>. \ / DESCRIPTION OF PROPERTY SURVEYED / '..B.,,1 z,,,,,,-....414.z 4 " .. / Lot I,Block 2,LAKEVIE W OF ORONO,according to the recorded plat thereof,Hennepin County,Minnesota. �ys 6�' j?f\\ \ I) Site Address:765 Lakeview Parkway,Oman,Minnesota,55364 3 Q- • / ,,,..„4„9\35.2 \N `� /\: I / 2) Flood Zone Information:This Property appears to lie in Zone X(Area determined to be outside the 0.2%annual chance \ ,". L.,�, n floodplain)per Flood Insurance Rate Map,Community Panel No.27053CO285F,effective date of November 4th,2016. N 97�5.gS}(•7_N / \ \ v Q 3) Parcel Area Information: Gross Area: 107,929 s.L -2.48 acres / \ ,\ N \ \\ as ass N N N 772�,S� \ 4) BeaeYmrk:Elevations are based on development Benchmark located Lots 1/2,Block 2,LAKF.VIEW OF ORONO,which has ° \ \N \N 9rP0'p)4 \ an elevation of.961.48(NGVD29). \ N N '...*N / / i �\\--- ` / _ _ 5) Zoning Information:z:The currant Zoning for the subject property is LR-1 A(One Family Lakeshore Residential-2 Acres)per N\ 1 .73.2 \\ \ �/\ BLOCK the City of Orono's zoning nap dated September 2016.The setback,height,and floor space area restrictions for said zoning \ 1431, J]\ r designation were obtained from the City of Orono found on their web site on the date of October 31st,2017 and areas follows: /� 9as.1 \ \\ \ Gj� Principal Structure Setbacks-Front:50 feet(Lakeview Parkway) _ J N �e�\�\>UTILITYI EASE GE ENT - \ \_�\ \ A9, , LOT 8 / Side:10 feet Rear:50 feet / ��/ N , 1 .93.k \� i G- N\/ \ `933./� \ \ - 'Y� N / Height:30 feet \ \ OTco \ \ • \ l� Hardcover:35 percent of lot area per Tier 3 Stornwater Quality Overlay District Map /N\I \ .935.9 934.2 \ 1 i\\ \. \ / T--` ---S84 7'58"E les. / '�° I s \� LOT 7 Please note that the general restrictions for the subject property may have been amended through a city process.We could be 51 \ S 4 --L \ I/\ )'\`1.;'4* \ \ / unaware of such amendments if they are not in a monied document provided to us. We recommend that a zoning letterbe \ Y9 / _ \ obtained from the Zoning Administrator for the current restrictions for this site. F--- V I�a39.e \ \ ',\\ Ra , / 6) Utilities:We have shown the location of utilities on the surveyed property by observed evidence only.There may be / 9361', r' 11 9111 I„ i r/ l � G�33 8s �� underground utilities encumbering the subject property we are unaware.Please note that we have no placed a Gopher Sate One 1 1 1111 `\) \ �zZ /�L3?' + _� Call for this survey.There may or may not be underground utilities in the mapped area,therefore extreme caution must be Ili isit rENCEJ /� /\ � ej �_ exercise before any excavation takes place on or near this site.Before digging,you are required by law to notify Gopher Sate B I I �/ One Call at least 48 hours in advance at 651/454-0002. vvTivT 111 __CONSERVATI01 ____1/ It I� /T / / f9H.1 \ /�\�\ 1,1111\114.... I gVii ? a, EASEMENT 1- / f '6"1-,, B 11 1 I )-1 I /2 e / �/ 1 ) � \ 1 1 951.5•\ eu n No v \ 1 9.4 1` \ \ \ \• -] L \\ C\ .s 2.. Proposed Elevations I \ �'. � I _�s2L-� ,, Proposed Garage Floor Elevation =949.9 1 1 \` \\ \ IBS'6f I\ NI y�I m \I t�:is \ -� Proposed First Floor Elevation =952.4 \ 1 1 1 I\ \ \ N ‘6,,\. g.y,J I \ " Proposed Top of Foundation Elevation -950.2 N It I \ \\ \ \ .tl�k y^ / ` s I9so\ /.9g-0-, Proposed Basement Floor Elevation -941.5 rt N 11 I 1 1 II \\\ \\ \ k \ �t\..�T. 64/ g ` \1 \I/ .%2.a \A 963.3 1 \ *9sdt `�Se'AV 1 Offset Irons 1� \ 1 ' PROPOSED I \ / e / (elevations arc to the top of pipe) 1 I 1\ • \�SEPTC SITE \\ 0//23 �- I •-.J OS 4l=94__223 17S 42_=94 221 101 -) - 1J ++/\ 9529 OS 04=948.15 OS cr \ 34 943.99 I 1"93�.a \ \ '� \I 1 \ / JI ;� \� \ OS 05=944.75 OS x.K>=942.99 r A +�, 11 11 \1 II m IV\ ;1 \i � �o � •� I I 959.6 �9�.6 OS nk=941.46 OS 07=944.96 pll\ 1 ryyv / ' \I I`& i I1 ) g l \I1 1\ PR osED /i 9d,,f Y\ ' `\,1 \ ___ Asbuilt Elevations 1 I 1 7 9 1 SEP 1�S E I t Asbuilt Garage Floor Elevation =949.5.5.33=949.81 NOT POCREDI \ 1 I ,I 3AAAo I / \. m ® \0 / ,=\r FENCE Asbuilt Top of Foundation Elevation =950.1 I ¢T*TIB Asbuilt Basement Floor Elevation =941.2+0.33=941.5 1NOT POURED) \ 1 I 9565 - _ A a'kit," I .CPN Van��-. WETI / 1 933.2' :0421 f.�,"ao• • Ay°e s '?+o �� I 4: 1s o� _I 1.:. \ Iia± ® )li' / l N 111 ' I ! I � o '� '_ BLOCK 2 I �� 9�/ M _� _ 11 q _ ,.-19°0•°11134111r- Y� � 50. s:9' \ •9s3.z \ ? y, I' \ I‘ -o 'oo� i -' 11 LOT I I I %910.4 ` _'''• :II-.s -.so S? •+e 1 ';•,'',J0>,,-- 1 1 I I I •1.60 •\ Q! 4 \ 1 I L.OT 2 326 t AWms /0 1 .9 WET x I I I t 5) \ n�. \ 11 h�a.ae 1 9J34 I / 940O •_ N.>oa o'zOo \v r�1v,, II I �, zm :���jo�11 ---- OERvtt11��noNII I I ( I� �A ��'�0,1 . v s 'C'-'7,, A,,,_.4....a_____....7::,. +s.o- 1-'' A v EASEINT I- I a ,2 Z 31oJ' O P '^s + .4.- 1 \ - '�,�` 1 I -` rw r� ymf \S, 1 \ i \ WET I \ I p I. 0 o �� d 0I" m \�/ \ \„I 1 933.0" $ v T Kira. po:,re q> \ o N940.. e. 94.46 - I a. NO Rte 11 n l' % I / \� 1 // / \ I Crr I WO \\ I / (I 9w.J 1<I. '9.< / 30 15 0 15 30 60 rS�� L _ -�� 914.2 115 onv i L.v i B 1\\ I I 111 \ '' �9s-`9�1 i �-<`-�$- 0 94x.4 \ 1 I ` \ I I \ i - /�\ //k SCALE IN FEET 1\ I \ \ \i1 \I,/ / . ,/ m -9 ( • \\\ SURVEY LEGEND . \ WEIR \ \ "_ , _=z- _ \\ �" *9120 x913.1 • I I BITUMINOUS 9J3.A \ T 587.04'36-W 122.59/""- \ LjIa \ \ O CAST IRON MONUMENT 0 UNIT \x I 1 1 --s/()FEN E / 0 CATCH BASIN 0 CABLE TV PEDESTAL BseL BUILDING SETBACK LINE \ ' '3 .Tye ,s \ \ 4 FLARED END SECTION El ELECTRIC TRANSFORMER -CTV-CABLE TV I I \ j4352 / ->,\ !' \ `,, 00 GATE VALVE 0 ELECTRIC MANHOLE Iss / ___ - \i < GUY WIRE 0 ELECTRIC METERCONCRETE CURB 1\ I \ -- CONSERVATION,/_---_ `-=. •'aw'6I ICONDRETE \v1 s EASEMENT CC \ HYDRANT 0 GAS METER -s•o_-CONTOUR EXISTING \ I O SURVEY MONUMENT SET 0 GAS VALVE CONTOUR PROPOSED -,5 '9,3,,,,,,, 931.6. 1, / 1\ .4. \ • SURVEY MONUMENT FOUND GUARD RAIL of-DRAIN TILE 1\ \ i� 5\ -4: / 1 x9362 I -\ vA� SURVEY CONTROL POINT ® HAND HOLE do ELECTRIC UNDERGROUND \ -, \ -9454 is:k \ \9.01 0 LIGHT POLE 0, SOIL BORING -a-a-FENCE $ 1 __----/ ='�! \ 'Li+ POWER POLE TREE CONIFEROUS -rn DEER OPTIC UNDERGROUND WET -cA9 GAS UNDERGROUND 69 Qsp32] r \ -__ -_ a\ ® SANITARY MANHOLE TREE DECIDUOUS -__ 'S/ TELEPHONE MANHOLE -ma-OVERHEAD UTILITY f 6,0`34 Wp41�WE l�.xi•'• \ 0 SANITARY CLEANOUT 0 \ s SIGN CO TELEPHONE PEDESTAL 11111111111111111N RAILROAD TRACKS / WET 9J2 / '9329\ GROUND ELEVATION ®TRAFFIC SIGNAL >-SANITARY SEWER _ ® STORM DRAIN 0 UTILITY MANHOLE >-STORM SEWER _� -- -_ x933T.0 vVTi.vT ass., x \ ® Tn- TELEPHONE UNDERGROUND a33.t STORM MANHOLE 0 UTILITY PEDESTAL UTILITY UNDERGROUND 0 YARD LIGHT ® WELL --I-WATERMAIN FIELD CREW NO. BY DATE REVISION USE(INCLUDING COPYING,DISTRIBUTION,AND/OR I hereby certify that this survey,plan or report was prepared by me or under my direct supervision and that I am a duly Licensed TWP.117-RGE.23-SEC.07 FILE NO. AT,BB I aav 2/na,, rocNoo,lnn AM., CONVEYANCE OF INFORMATION)OF THIS PRODUCT IS Land Surveyor under the taws of the State of Minneswa. ERS SNCERTIFICATE O F SURVEY STRICTLY PROHIBITED WITHOUT SATHRE-BERGOUIST, sz R0 Protect City:Orono 31202-432 DRAWN INCOUTSID AUTHORIZATION CONSTITUTES USE Dmedt's 8th day o(No November,201L v SATHRE-BERGQUIST, INC. Hennepin Connly BRV WITHOUT woADTHORI:wTroN coNSTlrt]rES AN 0 a✓ NFOUNDATION ASBUILT ILLEGITIMATE USE AND SHALL THEREBY INDEMNIFY .�« CHECKED SATHRE-BERGQuISTINC.OF ALL RESPONSIBILITY. 1 \ %,,, ISO SOUTH BROADWAY WAYZATA,MN.55391(952)476.6000 Lakeview PREPARED FOR: DBP SATHRE.8ERGOUIST,INC.RESERVES THE RIGHT TO \ J VIIP HOLD NIBRLEGTTIAMAGUSER 0 LOSSES RESULTING �eA� �-�m " `gyp Parkway GONYEA HOMES DATE RESPONSIBLE FOR DAMAGES OR LOSSES RESULTING David B.Pemberton,PLS Minnesota License No.40344 c^i es2 0920/17 FROM ILLEGITIMATE USE. pembemon4sathre.com FRS PeH A.,5 Sd- II Ery TIME CITY OF ORONO CALLED IN O INSPECTION N C SCHEDULED ,'/,�� PERMIT NO. /i d/'/� MPLETED ' ADDRESS / 63- of /JL-2 L.tJ T OWNER 00/11-e,1T EPHONE O/L)-- i-572, CONTRACTOR /, - , A a DESCRIPTION �i l ,e/ / ty ❑ FOOTING 0 DEMO-FINAL SEPTIC FINAL Q ❑ POURED WALL 0 PLUMBING RI 0 EXCAV/GRADING/FILLING v) 0 FOUNDATION DRAIN TILE 0 PLUMBING FINAL 0 TREE REMOVAL Z ❑ LATHE 0 MECHANICAL RI 0 SITE INSPECTION Q 0 FRAMING 0 MECHANICAL FINAL 0 RATED WALLS Z ❑ INSULATION 0 WOOD BURNER/FIREPLACE 0 COMPLAINT Q ❑ FINAL 0 WATER HOOK-UP 0 FOLLOW-UP W 0 AS BUILT-SURVEY 0 SEWER HOOK-UP 0 FOUNDATION/REMOVAL v ❑ DEMO-SITE 0 SEPTIC INSTALL .C."- OWNER/CONTRACTOR TO MEET YOU:_YES_NO a COMMENTS: /P,GI'�/e/ 04- s-? b S L4pFac� J O l ac (7 fli- fr 'CIA p<1I 1VJ 47 'or'-d -F0 i' 0O W .,-// /�h..5vez-I-)�h� c Q Lu.... j CI W ID WORK SATISFACTORY`.PROCEED ❑PROJECT COMPLETE i�, eORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY C4 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. 0 PHOTO TAKEN INSPECTOR WILL RETURN O STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlContractor on site: Inspector: try-► Je White Copy/inspector'a File Canary Copy/Site Notice