Loading...
HomeMy WebLinkAboutSeptic Compliance Inspection Minnesota Pollution Compliance Inspection Form Control Agency 520 Lafayette Road North Existing Subsurface Sewage Treatment Systems (SSTS) Si.Paul,MN 55155-4194 Doc Type:Compliance and Enforcement Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes: requirements and attached forms—additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days System Status System status on date(mm/ddlyyyy): 11/2/2017 ® Compliant— Certificate of Compliance ❑ Noncompliant— Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.) frame outlined in Local Ordinance.) Reason(s)for noncompliance(check all applicable) O Impact on Public Health(Compliance Component#1)—Imminent threat to public health and safety ❑ Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety El Tank Integrity(Compliance Component#2)—Failing to protect groundwater ❑ Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater El Soil Separation(Compliance Component#4)—Failing to protect groundwater ❑ Operating permit/monitoring plan requirements(Compliance Component#5)—Noncompliant Property Information Parcel ID#or Sec/Twp/Range: Property address: 2120 Carriage Lane,Orono Reason for inspection: Sale Property owner: Bonnie Velie Owner's phone: 612-964-7865 or Owner's representative: Representative phone: Local regulatory authority: City Regulatory authority phone: Brief system description: 2-1300 gal septic tanks& 1300.gal pump tank with a mound system Comments or recommendations: Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. Inspector name: Josh Swedlund Certification number: C1659 Business name: Sewer 4 es I• License number: 2502 Inspector signature: Phone number: 952-873-3292 Necessary or L•cally Required Attachments ® Soil boring logs ® System/As-built drawing ® Forms per local ordinance El Other information(list): www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31 • 3116/12 Page 1 of 3 • Property address. 2120 Carriage Lane Orono Inspector initials/Date: JS 111/2/2017 (mm/dd/yyyy) 1. Impact on Public Health— Compliance component#1 of 5 Compliance criteria: Verification method(s): System discharges sewage to the 0 Yes ® No ® Searched for surface outlet _ground surface. ® Searched for seeping in yard/backup in home System discharges sewage to drain 0 Yes ® No 0 Excessive ponding in soil system/D-boxes tile or surface waters. 0 Homeowner testimony (See Comments/Explanation) System causes sewage backup into ❑ Yes ® No 0 "Black soil"above soil dispersal s stem dwelling or establishment. P Y ❑ System requires"emergency" pumping Any"yes"answer above indicates the 0 Performed dye test system is an imminent threat to public health and safety. 0 Unable to verify(See Comments/Explanation) 0 Other methods not listed (See Comments/Explanation) Comments/Explanation: 2. Tank Integrity— Compliance component#2 of 5 Compliance criteria: Verification method(s): System consists of a seepage pit, 0 Yes ® No ® Probed tank(s)bottom cesspool, drywell, or leaching pit. ® Examined construction records Seepage pits meeting 7080.2550 may be compliant if allowed in local ordinance. ❑ Examined Tank Integrity Form(Attach) Sewage tank(s)leak below their 0 Yes ® No ❑ Observed liquid level below operating depth designed operating depth. ® Examined empty(pumped)tanks(s) If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for"black soil" 0 Any "yes"answer above indicates the Unable to verify(See Comments/Explanation) 0Other methods not listed (See Comments/Explanation) system is falling to protect groundwater. Comments/Explanation: 3. Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound. 0 Yes* ®No 0 Unknown b. Other issues(electrical hazards.etc.)to immediately and adversely impact public health or safety. 0 Yes* ®No p Unknown *System is an imminent threat to public health and safety. Explain: c. System is non-protective of ground water for other conditions as determined by inspector. 0 Yes* ® No *System is failing to protect groundwater. Explain: www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800.657-3864 • Available in alternative formats wq-wwists4-31 • 3/16/12 Page 2 of 3 • Property address: 2120 Carriage Lane,Orono Inspector initials/Date: JS I 11/3/2017 (mm/dd/yyyy) 4. Soil Separation —Compliance component#4 of 5 Date of installation: 10/26/1999 ❑ Unknown Verification method(s): (mm/dd/yyyy) Shoreland/Wellhead protection/Foodm/ddi beverage Soil observation does not expire. Previous soil lodging? ® Yes ❑ No observations by two independent parties are sufficient, unless site conditions have been altered or local Compliance criteria: requirements differ. For systems built prior to April 1, 1996, and 0 Yes El No ® Conducted soil observation(s) (Attach boring logs) not located in Shoreland or Wellhead Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) beverage or lodging establishment: El Not applicable(Holding tank(s),no drainfield) Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) separation distance from periodically ❑ Other(See Comments/Explanation) saturated soil or bedrock. Non-performance systems built April 1, ® Yes ❑ No Comments/Explanation: 1996, or later or for non-performance systems located in Shoreland or Wellhead Boring: Protection Areas or serving a food, 1-12" 10yr 3/3 loam beverage, or lodging establishment: 13-26"10yr 414 clay loam Drainfield has a three-foot vertical separation distance from periodically No Redox saturated soil or bedrock.* " " "Ex erimental, Other" or "Performance" P ❑ Yes ❑ No Indicate depths or elevations systems built under pre-2008 Rules; Type IV ' or V systems built under 2008 Rules(7080. A. Bottom of distribution media 12"+ 2350 or 7080.2400 (Advanced Inspector License required) B. Periodically saturated soil/bedrock ! 26"+ Drainfield meets the designed vertical C. System separation 36"+ separation distance from periodically saturated soil or bedrock. D Required compliance separation' 36 Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local failing to protect groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*— Compliance component#5 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑ Yes 0 No If"yes",A below is required Is the system required to employ a Nitrogen BMP? 0 Yes ❑ No If"yes", B below is required BMP=Best Management Practices)specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria a. Operating Permit number: Have the Operating Permit requirements been met? ❑ Yes 0 No b. Is the required nitrogen BMP in place and properly functioning? 0 Yes 0 No Any "no"answer indicates Noncompliance. Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded.replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance.If the system is failing to protect ground water,the system must be upgraded.replaced,or its use discontinued within the time required by local ordinance.If an existing system is not failing as defined in law, and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas. Wellhead Protection Areas, or those used in connection with food.beverage, and lodging establishments as defined in law. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31 • 3/16/12 Page 3 of 3 IO cgrrisp5e Lw ik' Z > • ' 7 0 4\ • .\ i Ik.,\\\64 .6\:1 UtP' 11:A4'' A ' •AN, 1.0 L-3"' J Q" A B MHt, 77. ga ' f' s „ M i1/4 qy 6 r' 90' 3" M%3 0:7' lab' 3' Pumping Report Sewer Services Inc. tic:2502 Date Serviced: (1-2. f fi Driver: _,,f/f\- Type:Residential/ Commercial Industrial Scheduled Maintenance Emergency Services: Start time: t4 i S Stop time: C C_,, Name: 1j0111 Y1 k, VCIC“,._ Phone: 6,i2.....(16,(1- Address: a I go C e YY;Aaye. {.auu City: 6{Og Did you measure the accumulatifdn of scum and sludge? Yes o pumped regardless Tank 1 Tank 2 Tank 3 Tank 4 Pretreatment Pump Tank Gallons Billed ),`304 )13°° 4-x-) Scum Sludge %full Operating Depth Access used ,n1qr// N1 f/ Depth to lid ?''C.(.. ,_ 6 /? 1 ,refuse to allow the removal of the solids and liquids through the maintenance hole.I understand that removal of solids and liquids through other access points is not considered a compliant method of solids removal and does not fulfill the solids removal requirements of Minn.R.7080.2450 and 7082.0600 Owner's Signature: Tank Type Pr ' Block - Come) Plastic - Other 4 Filter: Yes No rte --) Type of system: /Acirj Type of waste oT) mestic.' Holding - Co mercial - Industrial - Flammable waste trap Are tanks opera mg t designed depth? e)No, Did you obserrve sewage discharging onto the ground surface N4Yes, �(f � Electrical condition: rj Pump Size: Are all of the covers securely replace . es No, Safety concerns: Disposal site: LO ye C Next recommended pumping: Ali/.P') Other: Comments: Sewer Services Inc.25648 200th Street-Belle Plaine,MN 56011-952-873-3292 Septic tanks should be pumped elJery 1 to 3 years. Billint?Inlformation Many different variables determine how often Pumping(first 1000 gal.): ,,Og 11 a tank needs pumping: Additional gallons($80.00 per 1000 gal.):__/6/P-v Exposing Manholes(12"deep or less no charge): ❑ Type and age of system Excessive Distance(more than 120•): ❑ Number of people in the house Excessive Grade(more than 20'total lift): ❑ Garbage disposal Riser: o Tank history Emergency Charge: Materials: PUMP REPLACEMENTS, Labor: awl 1l1Gt11.ee- 399 INSPECTIONS & REPAIR Permit: Filing Fee: $5.00ao Payment Method: Total Due: State Certifie <d None -Cash -Check (# ) Credit Card= 25648 200th St•Belle Plaine,MN 56011 •952-873-3292 Type # Exp. . - ar Leccrn� Fl Daily SlipFlo 6opi_*my__ — Phone 612-964-7865 Bonnie & Decker Velie Alt-Phone 2120 Carriage Lane Work Orono MN 55391 Cell (612) 747-5097 System: Mound Pumping Frequency: Every 3 Years Directions: Pump Size: W0E511 PUMP FROM ROAD a-1360 Brie k lato 704 Tank:08d0-"gal precast tanks on W side of house. 1st&2nd tank manholes 4"deep. Pump tank manhole @ grade by mound. 5 hoses. Comments: Quad Hennepin County —---- ---- -------- Notes Date lime Regarding Record Manager 10/31/2017 12:57 PM Needs a compliance Kirsten Theis 5 Bedrooms Built 2000 needs to be pumped out as well CC on file email report to city and customer 6/20/2017 8:41 AM 6/21/17 Corey checked pump,pump float,cycled pump breaker never tripped. Kirsten Theis Everything is working properly-billed for servce call$175.00 inv#8508 breaker has been tripping for over a year-doesn't want to pay$85 emergency fee- havng Corey"bury the fee"for service call.-printed 6,20 6/20/2017 7:40 AM Deker LVM over night saying his breaker keeps tripping-returned his call and got his Kirsten Theis VM 3/26/2015 7:24 AM Josh pumped 3 tanks 2500 gal thru manhole,pump was running correctly when he Melissa Allen arrived,water level was normal put a new 6"new cap billed$397.50 11/20/2013 12:56 PM Labor and parts to change out warranty parts billed$150.00 Angie Salonek 10/8/2013 11:33 AM electrical company came out,he thinks that the pumped it is surgin at 32 amps settle Melissa Allen downs at 18,the electrican thinks that it is the motor in the pump? She has no idea... Please call.. 9/9/2013 8:30 AM Josh tested everuthing alarm,works perfect,electrical problem in house,told to call Melissa Allen elecrtictian billed$125.00 5/3/2012 9:01 AM Jason pumped 3 tanks 2250 gal wat thru manhole,2nd tank concrete is disintegrating Melissa Allen around manhole cover and pipe going to the pump tank,customer wants to know what to do..,billed$346.25 5/13/2011 9:47 AM Alrm going off no braker tripped.Sent Brad out to fix problem Angie Salonek 5/13/2011 8:59 AM Brad replaced bad pump. Billed 915.00 on 5/13/11 Angie Salonek 9/8/2009 10:03 AM Pete pumped 3 tanks thru manholes.Billed$335.00 9/11/09. Angie Salonek Created 10/31/2017 at 1:01 PM Page 1 of 1