Loading...
HomeMy WebLinkAbout2017-01456 - in-building sprinkler system CITY OF ORONO I* 2 I 0 1 7i 111 [- 0 1 151 'I *I f 2750 KELLEY PARKWAY DATE ISSUED: 11116/2017 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS : 797 BRIDGEWATER DR PIN : 33-118-23-12-0021 LEGAL DESC : STONEBAY FOURTH ADDITION : LOT 010 BLOCK 001 PERMIT TYPE : FIRE SYSTEMS PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : SPRINKLER SYSTEM-IN BUILDING NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. FIRE SPRINKLER ENTER THE VALUTATION 4100 APPLICANT FIRE SPRINKLER-RESIDENTIAL 51.25 STATE SURCHARGE VAL OTHER 2.05 LIFESAVER FIRE PROTECTION,INC. MAIL-1N FEE 2.00 1000 BOONE AVE N#700 GOLDEN VALLEY,MN 55427- TOTAL 55.30 (612)930-7828 Payment(s) Minnesota State License#:BUIL-0060 CHECK 7448 55.30 OWNER Wooddale Builders 6117 BLUE CIRCLE DRIVE MINNETONKA, MN 55343- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. C / .�.4 1.), ! /( / I (p / I) Applicant Permitee Signature Date /Issued By Signature V 7/ 4 Date ' ac I RECEIVED , dof7 vjtts,,. !11 CITY OF ORONO ✓` i New I I Addition ❑ Remodel I I Replace Backflow Device: n AVB n PVB � Site Address: � C --.1 (md(N- I )) ir)� , �k ) Owner: Li-f_ L %! - -' . � Mailing Address: -9---- U€-,Ci'C ' ' City s ia,'--Qin) Zip: Home Phone: cic)A. Cj-OC 17-) Alternate Phone: tea, Contractor/App.: LI - ( (--',-'{___(2 Contact Person: ."c. 5 L_ Address: 1L C' t� �_(1 � State License#: C,05 City: 6(; AQAm\JP) ZipC� Expiration Date: —( —< <.� Phone: 7 3-.1.5-46-).)N— --D,:-1------r)- — Alternate Phone: a'w, '/ ¥ a ' a s r6 ..,.,. ":� €< :. I nmmercial—Fire Sprinkler Residential—Fire Sprinkler Fire Systems Permit Fire Systems Permit _ * Base Price=Contract Price: $�( 1 x.0125 =$ 3 �� (Minimum$50.00) * Surcharge=Contract Price: $ x.0005 =$ (-11:F.) * Mail-In Fee(Only On Mail In Applications) =$ 2.00 * Total Cost of Permit: =$ C 7 j The undersigned herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees that all systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25, Minnesota State Building Code, Minnesota State Fire Code and Standards, and certifies that all statements made on this application are complete,true and correct.na 1 ,,V Applicant /) Date ONLY City of©rano Date Bacrtved d_ Petard k f ?" . 0 \ P.Q.Box66 too= S Cryo Keflet'Parkway Crystal Bay,MN 55323 prwtd �, AiRy. 611— ¢ •- (952)249-4600 \ 6 k smog-- • m ntceomeraly R oval Ocala CITY OF ORONO—AUTOMATIC FIRE SPRINKLER/GENERAL PERMIT (All permits rust be approved by the Fire Muskat]and/or Building Official) 1. Permits are required for all fire sprinkler installation and repair. All work shall be done by a licensed fire sprinkler contractor. Two sets of plans,specification data sheets,fire flow tests and hydraulic calculation sheets shall be submitted to the Orono Fire Marshal a minimum of 7 •:ys before start of work. 2. Permits can be applied for by mail at PO box 66,Orono,MN,55323 or in person at, 2750 Kelly Parkway;Phone:(952)249-4600. Permits are also available online at: www.ci.orono.mn.us 3. All systems shall be designed,installed and maintained to N.F.P.A.-13,N.F.P.A:25,Minnesota State Building Code,Minnesota State Fire Code and Standards. All attic systems are to be spaced at maximum 130 square foot coverage. Plastic pipe will not be allowed at any time in attic spaces. 4. All equipment installed shall be U.L.or F.M.approved for fire protection service.Water flow test shall be completed on all new systems.Water flow test reports shall be submitted to the Orono Fire Marshal along with plan submittal. 5. Yard or wall post indicator valves are required. All indicating and control values installed shall be provided with tamper protection.On dry systems,the control valve to service the pressure switch(air) shall be supervised. 6. Inspectors test valve shall be installed on each floor level or zone of system.All systems shall have main drain and inspectors test valves piped to the outside. 7. No water is to be introduced into the sprinkler system until main has been thoroughly flushed.200# air test and flushing shall be witnessed by the City of Orono Water Department. 8. An approved audible/visual device wired to main flow switch shall be installed above F.D. connection and in areas normally occupied by tenants. 9. EXISTING SYSTEMS: If any changes in the hydraulically roost demanding area,change in occupancy classification or an addition of20 or more heads,hydraulic calculations and flow test will be required. 10. The Orono Fire Marshal shall witness all final flow or trip tests. Appointments can be made by calling the Fire Marshall at(952)473-9701,8.00-4:00 p.m.Monday-Friday. 24-hours notice is requested. 1 I. When requited,(30 foot building height)stairwell standpipe's shall have 2 V2 gate valves installed with 2 t/2 x 1 rh caps. Z d0 Z.L3324S V* Lill Iii kHl I k N ^!J.JJJ 111 I 3J 0 1 I i i d 6 0 13 ow z� • 1 I' s It'"s ( j ids ' If car r _.__ Ji-1(' '� ',mac. _ ; l 111 iii ^..� 0. _T. T f d ..... ii I I `d d dL �OL'iw:� , d./A 1 r —J '4 a l'• \ 1 1ii, I iF I/ i;i2 � pi gyp{ I 0.01 " ' i j1 3T L } L A L a n <, ��iig U {Eilu! I IPI . (OM ,H11 1911 I! 1 _!IN r iil ii IritIII Old!!! yr 22-4., If 1 il ii Ppl 11 Nal 6i II -2 l 40 1 13;INS ! iv lip ! EMI Idi pi 111 1 1 \ ,, 4:;?____al PKI, I 4119: I 1 \I-• - 11 L -- d I 7 . " lit! ! 1 [r :3'.' n I 1 — 1 i • - t - ,.5 'M us . ;elf- :. ' i - Z , sr--_ __1 •A ler II i I ! tit 1 hili . t a 11 0-,ti It il . . I ` LI ----.4- .--1 --..'Z.:J. i..! •.Z.....jr, — ._...-4. I . ......... rm. 1 i .. 1 I ni'I hf ; d il . rt: t,,,! _ , , ,, _ A . - . . . . , , 1 4: 82 .. _ _1 i, 1 40:Ibl'11111 Nth r Ai . I '1 ___ 111 i .- . W - I :4+;1.:1 'N it il&li\I, I., .t. - •.- .=-• . b a 1 I 1 1 .1.11 I q - --, I "" 11 v Ii 4 1.2 14 -,..... 1 ii-.9 N • .-I1104-0 II ,.,Z I I to i - 1 --. 1 • 1 1 e I I 4'471 ----1b VP.riT, 1 I I .-b,_2147„ i• , , IL........ il 1 'ite-Eltii...1 _ : tii-7 1 1 ,k31 Ai....f • .1 11" g 6-Ai,,,,,, r , t i .- ,..L ':, 1 i 'I 1...1.10j/ j Pt r ii I • II 1. t4.,..., - , I; • ‘t s,-,-,-. ---,-, _ _ 1 , - -r4,. r i . ' a . • . L .•-• 'k..., --1 4-'4";•• : ' 1 • I 1 ••• I I' II.Z`•.- 1 1' I / I I I I 1 r I I Il '11 i. 6.r, -'- I I I II 1 :1!.. IsiALII 11 I 13 --,..: P ' I ii .; 1 I 111 1 t frA..= _11, : Trr 1 i -, _ ______ ,-• .=-1.-11 1 t 11 1 111111 11 •-n- i I im iii 1113, POI i 711 1 / /Man mnarill .... : I , \ i ; IVA Mall 1, id liEbiii I f_. 11111 mil• gll' i • 1 i 81 • tt-./,, i i i il i= qi 1II LI ' , d J ' ! 19! 1, , I- , i 9 1 E 1= ...ma EMI II _I 1? ti El dl `, 11 IPI IIIII II 1. 1 11 Page 1 of 5 N11(1NG® FREEDOMS RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcsgvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom®Residential Pendent Sprinkler VK468 is a small, thermosensitive,glass- bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements.The Electroless Nickel PTFE(ENT)coating has been i a investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corro- li a sion resistant as indicated in the Approval Chart.The orifice design,with a K-Factor of 4.9 (70.6 metrict),allows efficient use of available water supplies for the hydraulically designed • fire-protection system.The glass bulb operating element and special deflector characteris- tics meet the challenges of residential sprinkler standards. C ; 2. LISTINGS AND APPROVALS w � ut 's UL Listed(C-UL-US-EU):Category VKKW I iZOP EU [yds VdS Approved NYC Approved: MEA 89-92-E,Volume 35 UL Classified to:NSF/ANSI Standard 61, Drinking Water System Components(MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi(12 bar). Factory tested hydrostatically to 500 psi(34.5 bar). Thread size: 1/2"(15 mm)NPT Nominal K-Factor:4.9 U.S.(70.6 metrict) tMetric K-factor measurement shown is in Bar.When pressure is measured In kPa,civide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65°F(-55°C) Overall Length:2-1/4"(58 mm) Material Standards: Frame Casting:Brass UNS-C84400 or OM Brass Deflector: Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass UNS-C26000 Bulb:Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy,coated on both sides with Polytetrafluoroethylene(PTFE)Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw:Brass UNS-C36000 For ENT coated sprinklers: Belleville spring-Exposed,Screw and Pipcao-ENT plated. Ordering Information:(Also refer to the current Viking price list.) Sprinkler:Base Part No. 13637 Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome=F,White Polyester=M-/W, Black Polyester=M-/B, and ENT=JN Temperature Suffix: 155°F(68°C)=8, 175°F(79°C)=D For example,sprinkler VK468 with a Brass finish and a 155°F(68°C)temperature rating= Part No. 13637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories:(Also refer to the Viking website.) Sprinkler Wrenches: A.Standard Wrench: Part No. 21475M/B(available since 2017) B.Wrench for recessed sprinklers: Part No. 13577W/B*(available since 2006) C.Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool**Part No. 15915(available since 2010.) *AW ratchet Is required(not available from Viking). *'Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool.Ideal for sprinkler cabinets.Refer to Bulletin F_051808. Form No.F_012706 17.10.05 Rev 17.1 Replaces Form No.F_012706 Rev 14.2 (Replaced wrench 10896W/B with 21475M/B) • Page 2 of 5 N1K1NG. FREEDOM®RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler Cabinets: A.Six-head capacity: Part No.01724A(available since 1971) B.Twelve-head capacity:Part No.01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty,refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175°F(79°C) 150°F(65°C) Yellow Sprinkler Finishes:Brass,Chrome,White Polyester, Black Polyester,and ENT Corrosion Resistant Coatings':ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on lire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific Installation standards. 'The corrosion resistant coatings have passed the standard corrosion test required by the approving agendes indicated in the Approval Chart These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment For ENT coated sprinklers,the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Wrench Flats , Protective inil�i, Protective rP�,: .i1, � • QiL=�:, Sprinkler FM OSprinkler Gap Shield w `• 21475 m� Figure 1: Standard Sprinkler Wrench 21475M1B Form No.F_012706 17.10.05 Rev 17.1 Page 3 of 5 NIKim® FREEDOM®RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468(K4.9) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Overall Length Part Number' Inches mm U.S. metric2 Working Pressure Inches mm 13637 VK468 1/2 15 4.9 70.8 175 psi(12 bar) 2-1/4 58 Ordinary Temp Intermediate Temp Listings Max. Rating (155°F/68°C) Rating(175°Ff79°C) Deflector and Approvals Minimum Flow' Pressure' Flow' Pressure` to Installation Spacing Ft.X Ft Type C-UL- Ft. (m X m) GPM PSI GPM PSI Ceiling US- VdS NYC' NSF" (m) (L/min) (bar) (L/min) (bar) EU' 12 X 12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) Standard sur- face-mounted 14 X 14 13 7.0 13 7.0 escutcheons,the (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) Microfasb5 Model F-1 Adjustable See See See See 16 X 16 13 7.0 13 7.0 1-1/8 to Escutcheon,or Foot- Foot- notes notes (4.9 X 4.9) (49.2) (0.48) Foot- Foot- 8 (492) (0.48) 2 inch recessed with 7 and 7 and note note (2A) the Mkxomatke 10. 10. 7' 7. 18 X 18 17 12.0 17 12.0 Model E-1, (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) E-2,or E-3 Recessed 20 X 20 20 16.7 20 16.7 Escutcheon (6.1 X 6.1) (75.7) (1.15) (75.7) (1.15) Footnotes 'Part number shown Is the base part number. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure Is measured in Bar. When pressure Is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 'For areas of coverage smaller than shown,use the"Flow"and'Pressure'for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum'Flow"and"Pressure"used. 5 Listed by Underwriter's Laboratories,Inc.for use in the U.S.,Canada,and European Union. 'Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.35. 'Approved Finishes are:Brass,Chrome,White Polyester,and Black Polyester° °UL Classified to:NSF/ANSI Standard 61,Drinking Water System Components(MH48034). a Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. t0 Approved finish is Electroless Nickel PTFE(ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. Form No.F_012706 17.10.05 Rev 17.1 Page 4 of 5 • NIKING® FREEDOM®RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9601 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com It , r . I ;l/ Ilii- iriI'. 1 r2.r l�k�Irllr�\Il Ma II MEIJI] I/. , Sprinkler Wrench7-116° 13577W/Bww must be a used for installing Step 1: Carefully slide recessed Sprinkler . the wrench sideways + around the deflector i--___- r and protective shield. l Step 2: Carefully press (Note the orientation of the wrench upward and the shield fn the wrench.) turn slightly to ensure *xi; 1/2' ratchet Is required engagement with the (not available from Viking). sprinkler wrench flats. Figure 2: Wrench 13577W!B for Recessed Sprinkler Installed with a Microfast Model F-1 1/2' _ AdJustafole Escutcheon (15 mm)�� - :::: ......... j1eii NPT f � Ewa w■w � /liter lj11 .�:.�::: ti16=,\I_, 2-1/4' fl.I ' 1 3/4' �_� 'i.t:?t:....... 1-1/2' IT (58 ctrl) ''`_�, C44.5 mm) sa>_ IF,,=l.,Fri •�::::(38.1 mm) �)♦� j It1M1nu mm) Maximum I, I 1-1/8_ I Installed with a —_._... standard 1/8' (3,1 mm) (28.7 mm) surface-mounted escutcheon Sprinkler VK468 Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Form No.F_012706 17.10.05 Rev 17.1 Page 5 of 5 N11(ING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Ceiling Opening Size' 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum lief -� i� IE..1� , .. ifi- � I ( 1 f h tu 1-3/4' 11TO ! � 1-1/8' 028,6 mm) 2' '��p 1-1/8' (28.6 mm) C44.5 mm) ■ Minimum (50.8 mm) ■/ Minum Maximum —._._.. 1 Maximum Tf Installed with a Mlcromatic Installed with a threaded Micromatic Model E-1 Recessed Escutcheon Mode( E-2 Recessed Escutcheon Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons UL Listing Reauirernents(C-UL-US-EUI: When using Viking Residential Pendent Sprinkler VI(468 for systems designed to NFPA 130 or NFPA 13R,apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13;The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: •The flow rates given in the Approval Chart for NFPA 13D and NFPAI3R applications for each listed area of coverage,gr •Calculated based on a minimum discharge of 0.1 gpmisq.ft.over the'design area'in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. •Minimum distance between residential sprinklers:8 ft.(2.4 m). IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.Also refer to Form No.F_080614, F_080415 and F_080190 for general care,installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA,VdS,and any other similar Authorities Having Jurisdiction,and also with the provisions of governmental codes,ordinances,and standards,whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Form No.F_)12706 17.10.05 Rev 17.1 Replaces Form No.F_012706 Rev 14.2 (Replaced wrench 10896WB with 21475M/B) Page 1 of 5 NIKING® FREEDOM®RESIDENTIAL TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK484(K4.2) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-6464 Fax:269-818-1680 Email:techsvcsavikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom® Residential Horizontal Sidewall Sprinkler VK484 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated ,f in the Approval Chart. The sprinkler orifice design, with a K-factor of 4.2, allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector =' w characteristics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS cows cULus Listed:Category VKKW Refer to the Approval Chart and Design Criteria for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2011. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi(12 bar). Factory tested hydrostatically to 500 psi(34.5 bar). Thread size: 1/2"(15 mm)NPT Nominal K-Factor:4.2 U.S.(57 metrict) t Metric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65"F(-55"C) Overall Length:3"(76 mm) Material Standards: Frame Casting:QM Brass Deflector. Brass UNS-C23000 Bulb:Glass,nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy,coated on both sides with Polytetrafluoroethylene(PTFE) Compression Screw:Brass UNS-C36000 Pip Cap and Insert Assembly:Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring-Exposed,Screw and Piocao-ENT plated. Ordering Information:(Also refer to the current Viking price list.) Sprinkler:Base Part No. 16240 Order Sprinkler VK484 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass=A,Chrome=F,White Polyester=M-/W, Black Polyester=M-/B,and ENT=JN Temperature Suffix:155°F(68°C)=B, 175°F(79°C)=D For example,sprinkler VK484 with a Brass finish and a 155°F(68°C)temperature rating=Part No. 16240AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories:(Also refer to the Viking website.) Sprinkler Wrenches: A.Standard Wrench: Part No.21475M/B(available since 2017) B.Wrench for recessed sprinklers: Part No. 13655W/Btt(available since 2006) ttA W ratchet is required(not available from Viking). Sprinkler Cabinets: A.Six-head capacity: Part No.01724A(available since 1971) B.Twelve-head capacity: Part No.01725A(available since 1971) Form No.F_050310 17.XX.XX Rev 17.1 Replaces Form No. F_050310 Rev 16.1 (Replaced wrench 10896WB with 21475M/B) Page 2 of 5 NIKJNGO FREEDOM®RESIDENTIAL TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK484(K4.2) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK484 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175°F(79°C) 150°F(65°C) Yellow Sprinkler Finishes: Brass,Chrome,White Polyester,Black Polyester, and ENT Corrosion Resistant Coatings': ENT Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment.For ENT coated sprinklers,the waterway is coated.Note that the spring is exposed on sprinklers with ENT coating. Protective Wrench Sprinkler Flat _ Shield 'I,1 '. =11 — --=.- /: 2_____,), _ : 21475 ( ) Figure 1: Standard Sprinkler Wrench 2147SMiB Form No.F_050310 17.XX.XX Rev 17.1 Page 3 of 5 NiliaNG® FREEDOM®RESIDENTIAL TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK484(K4.2) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com NPT Thread Size Nominal K-Factor Overall Length Sprinkler Base Pa SIN Maximus Water Working Number' Pressure Inches mm U.S. metric 2 Inches mm 16240 VK484 1/2 15 4.2 57 175 psi(12 bar) 3 76 Ordinary Temp Rating Intermediate Temp • Listings and Approvals Max.ACoaoverage Max (155*F168*C) Rating(175'F!79'C) To of Minimum i Spacing P Installation Spacing Width X Length Deflector Ft.X Ft. Ft Flow' Pressure' Flow' Pressure' to Ceiling Type Ft. (m X m) (m) GPM PSI GPM PSI cULus' NYC (mi (Umin) (bar) (1../min) (bar) 12 X 12(3.7 X 3.7) 12(3.7) 13(49.2) 9.6(0.66) 13(49.2) 9.6(0.66) Standard 14 X 14(4.3 X 4.3) 14(4.3) 14(53.0) 11.1 (0.77) 15(56.8) 12.8(0.88) surface- 16 X 16(4.9 X 4.9) 16(4.9) 16(60.6) 14.5(1.00) 17(64.4) 16.4(1.13) 4 to 6 mounted inches escutcheons or 16 X 18(4.9 X 5.5) 16(4.9) 19(71.9) 20.5(1.41) 19(71.9) 20.5(1.41) the Microfast® Model F-1 16 X 20(4.9 X 6.1) 16(4.9) 22(83.3) 27.4(1.89) 22(83.3) 27.4(1.89) Adjustable See See 8 Escutcheon, Footnotes 7 Footnote 6 (2.4) 12 X 12(3.7 X 3.7) 12(3.7) 14(53.0) 11.1 (0.77) 14(53.0) 11.1 (0.77) or recessed and 9. 14 X 14(4.3 X 4.3) 14(4.3) 16(60.6) 14.5(1.00) 16(60.6) 14.5(1.00) the Microwit matic® 6 to E-1, 16 X 16(4.9 X 4.9) 16(4.9) 18(68.1) 18.4(1.27) 18(68.1) 18.4(1.27) chees E-2,s E2El-3,3, incor 16 X 18(4.9 X 5.5) 16(4.9) 20(75.7) 22.7(1.56) 20(75.7) 22.7(1.56) G-1 Recessed Escutcheon 16 X 20(4.9 X 6.1) 16(4.9) 25(94.6) 35.4(2.44) 25(94.6) 35.4(2.44) Footnotes Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 'For areas of coverage smaller than shown,use the"Flow'and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter's Laboratories,Inc.for use in the U.S.and Canada. Meets New York City requirements,effective July 1,2008. 'Approved Finishes are:Brass,Chrome,White Polyester,and Black Polyester° 8Other paint colors are available on request with the same cULus listings as the standard finish colors. °Approved finish is Electroless Nickel PTFE(ENT).ENT is cULus Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. Form No.F_050310 17.XX.XX Rev 17.1 Page 4 of 5 ® FREEDOMS RESIDENTIAL TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK484(K4.2) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com cULus Listing Reauirements: When using Viking Residential Sprinkler VK484 for systems designed to NFPA 13D or NFPA 13R,apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems desianed to NFPA 13:The number of design sprinklers Is to be the four contiguous most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the following: •The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage,or •A minimum discharge of 0.1 gpm/sq.ft.over the"design area'consisting of the four contiguous most hydraulically demanding sprinklers for the coverage areas being protected by the four sprinklers.NOTE:The As=Sx L method must be used to determine the sprinkler protection area of coverage per NFPA 13. • Minimum distance between residential sprinklers:8 ft.(2.4 m). • The VK484 horizontal sidewall sprinkler deflector shall be located a minimum of 1-3/4•(44.5 mm)and a maximum of 6'(152 mm)from the wall on which it is installed. DEFLECTOR POSITION: Install Viking Residential Horizontal Sidewall Sprinkler VK484 with the leading edge of the deflector oriented parallel with the ceiling and the sprinkler frame arms oriented perpendicular to the ceiling.Refer to the Approval Chart for the required distance between the top of the deflector and the ceiling. IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.Also refer to Form No.F_080614 for general care,Installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes,ordinances, and standards,whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler Wrench Part No. 13655W/Box for Recessed Horizontal Sidewall Sprinklers Protective Fit the wrench over the sprinkler Sprinkler and protective shield as shown, Shield rr FI r r i r ri r -- )191ENOte A 1/2' ratchet is required (not available from Viking), Figure 2: Wrench 13655W/9 for Recessed Sprinkler VK484 Form No.F_050310 17.XX.XX Rev 17.1 Page 5 of 5 NEKINGS FREEDOM®RESIDENTIAL TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK484(K4.2) The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcsgi vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Wall Opening Size. 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum 2-9/16' • 2-5/16' 3' (65 mm) ir,°l (58.7 mm) I It 1 Minimum - „t,.�: 1-11/32' + -- 2-1/B' e' ' — I��11� (34.5 mm) iI�,�I (54 mm) i I171.11-7— � ��I� , r . �_. (15 mm) NPT a;,- HSW Sprinkleril;k { 2-13/16' 16240 (VK484) (71.4 mm) Installed with a Maximum standard 1/8' (3.1 mm) Installed with a Mlcrofast surface-mounted escutcheon Model F-i Adjustable Escutcheon IN Note. at maximum, adaptor is exposed 1/2' <12.7 rim) from face of wall Figure 3: Sprinkler VK484 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon For use with sloped ceilings, Wall Opening Size, 2-5/16' (58.7 rim) minimum Wall Opening Size 2-1/2' (63.5 rim) maximum 2-5/8' (66 mm) minimum 'i,11;1 1-15/16• 2' 3-3/4' (95 mm) maximum (373 mm) €iI f (50.8 mm) I ilMinimum ;::;hill Minimum i . . f---alragow Alimiw, 2-1/8' �S 2-1/8 �S 2-5/8' (54 mm) ' 'vi �k46. _I (54 mm) i Ili' j1i (66 mm) , sr L . ,,,,,, , ,,,., .ti., , . . 1 if 2-9/16' l 2-3/4' `1,�I,' �. (65 mm) (70 mm) Maximum Maximum Maximum Recess: 1/2' (12.7 mm) I' Installed with a Micromatic Installed with a Model E-2 Installed with a Model G-1 Model E-1 Recessed Escutcheon Thread-on Recessed Escutcheon Recessed Escutcheon Figure 4: Sprinkler VK484 Dimensions with Model E-1,E-2,and G-1 Recessed Escutcheons Form No.F_050310 17.XX.XX Rev 17.1 Replaces Form No.F_050310 Rev 16.1 (Replaced wrench 10896W/B with 21475MB) Pagel of8 N11(1Nis® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp,com 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are : '' F:11111mC designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. IIL1 illi Viking Quick Response Dry HSW Sprinklers are available in various finishes ;,,' and temperature ratings to meet design requirements.The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE:When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an Indi- cation of corrosion and should not be treated as such.All sprinklers installed For Light Hazard Occupancies Only in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS ®u' cULus Listed:Category VNIV FM Approved:Classes 2013 and 2015 -C> NYC Approved:MEA 89-92-E,Volume 15 — Refer to Approval Chart 1 and Design Criteria on page 106c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 106d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1993. Minimum Operating Pressure:7 psi(0.5 bar) Maximum Working Pressure: 175 psi(12 bar). Factory tested pneumatically to 100 psi(6.89 bar) Thread size: 1°NPT or 25 mm BSP Nominal K-Factor:5.6 U.S. (80.6 metric`)for all listed and approved lengths. *Metric K-factor measurement shown is when pressure is measured In Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65°F(-55°C) Covered by the following U.S.Patent numbers:8,636,075 and 8,376,060 Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Frame Casting: Brass UNS-C84400 http:/lwww.vikinggroupinc.com Deflector:Phosphor Bronze UNS-C51000 The Web site may Include a more recent Bulb:Glass, nominal 3 mm diameter edition of this Technical Data Page. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-031400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice:Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support(Internal):Stainless Steel UNS-S30400 Barrel:Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads:QM Brass Sleeve(for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons:Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons:Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish,the appropriate suffix for the temperature rating, and then the suffix for the length("A"dimension)to sprinkler base part number.Order in a specific length noted as the"A"dimension.The "A°dimension is the distance from the face of the fitting(tee)to the desired finished surface of the wall in which it is to be installed. Form No. F_031993 Rev 15.1 Page 2 of 8 NIKING® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com These sprinklers are listed and approved in lengths from 1-1/2'to 45-1/2"(38.1 mm to 1,156 mm)for the adjustable standard style,3"to 47"(76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2'(82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order'basis:Recessed Dry HSW up to 65- 1/2"(1,664 mm).Adjustable Standard Dry HSW up to 63-1/2"(1,613 mm).Plain Barrel Dry HSW up to 65"(1,651 mm).Contact the manufacturer for more information. Finish Suffix:Brass=A,Chrome=F,White Polyester=M-/W, and ENT=JN Temperature Suffix: 155°F(68°C)= B, 175°F(79°C)=D,200°F(93°C)=E,286°F(141 °C)=G Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 Escutcheon(no suffix needed for the Model E-1 Escutcheon). NOTE; Sprinkler is turned sideways For example, sprinkler VK182 with 1'NPT Threads,a Chrome finish,a 155 for clarity. (Refer to Figures 2-7 °F(68°C)temperature rating,the Model G-1 Escutcheon,and"A"length for correct deflector orientation.) of 10"=Part No.08386UFBY10. Protective Available Finishes And Temperature Ratings:Refer to Table 1. , Sprinkler Accessories:(Also refer to the"Sprinkler Accessories"section.) Shield Sprinkler Wrenches: '4/41111 1 e • A. Standard Wrench: Part No.07297W/B(available since 1991) �yri1 hi I B.Wrench for recessed sprinklers:Part No.07565W/B"(available since 1991) , A'/z ratchet is required(not available from Viking). Il���i!■ � i Dry Sprinkler Protective Cover: Part No. 15610 ,:' A - � Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon:Base Part No.08086F Wrench B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A Flat 4. INSTALLATION / \ Refer to appropriate NFPA Installation Standards. _ 5. OPERATION ! VIKING During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter,releasing the internal parts to open the water- way.Water flowing through the sprinkler orifice strikes the sprinkler deflector, Figure 1: forming a uniform spray pattern to extinguish or control the fire. Standard Sprinkler Wrench 07297W/8 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Horizontal Sidewafl Sprinkler is available through a network of domestic and international distribu- tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordina 155°F 68°C 100°F 38°C Red Intermediate 175°F 79°C 150°F 65°C Yellow Intermediate 200°F 93°C 150°F 65°C Green Hi.h 286°F 141 °C 225°F 107°C Blue Sprinkler Finishes: Brass,Chrome,White Polyester,and ENT Corrosion-Resistant Coating':White Polyester and ENT in all temperature ratings Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- cated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note:These coatings are NOT corrosion proof.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.Polyester and ENT coatings are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 'When installed In some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an Indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Form No. F_031993 Rev 15.1 Page 3 of 8 "KI ® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vIkIngcorp.com vlkingcorp.com <:-':':' x*Notes A 1/2' ratchet Is required. Sprinkler Wrench Part (Not available from Viking). No. 07565W/Dxs for installing recessed - dry sprinklers. - - _I ---_ _I �___ ---■ iI r I = _ M 4_ " -_1!• II ii. i-----' I - , 1 f se lel `'.._ I I 1�1.--------- ---� Step 1. Carefully slide the Step 2: Press the wrench onto wrench sideways around the the sprinkler wrench flats and deflector and protective turn slightly to ensure engage- shield as shown. merit with the wrench flats. Figure 2: Wrench 07565WB for Adjustable Recessed Dry Horizontal Sidewall Sprinklers For 'A' Dimension. . I, Determine the distance from the face of1, -IIIIIIIIIIIIIIn1I11111111Ii,IIIIIIIIIl1IENOTE. the the to the finished face of the wall Deflector at To locate the deflector a Round to the nearest 1/2'(12.7 mm) between Finished Ceiling Distance at the minimum distance 1-1/2' (38.1 mm) and 45-112' (1,156 mm). from the wall, with no Finished Wall adjustment available, L NOTE. The deflector will extend approximatelyorder the standard dr 4-1/8' (104.8 mm) from the wall with 2' +/- 4' <102 mm) Minimum �-, horizontal sidewall sprink- 1' (25,4 mm) horizontal adjustment avakable. 6' <152 mm) Maximum* Or ler 1' <25.4 mm) shorter /� (79,4 ) than the 'A' Dimension ����\�\�� I"'1 Deflector at NDTEI `! 3-1/16' Maximum Distance To locate the deflector e I (772 mm) From Wall at the maximum distance , I IIIA I from the wall, with no .,, ..,....•;.1.. ■ l= ad,justmeat nvnllnble, / a.'-� hrder the standard dry S/8.059 pea r,= horizontal slderall sprink- Mlnimum wall opening I 1 ler I.' (25.4 mn) longer po 5-1/: than the 'A' Dimension. diameter. 1-3/4' (44.5 mm). I -Sleeve diameter' (1302 mm) Maximum wall opening 1-1/2' (38.1 mm). diameter, 2-1/4' <57 mm), 13/16' Sleeve finish matches a May be allowed up to 18' (457 mm) for certain (eab rim) finish of escutcheon FM installations. Refer to the appropriate Installation standards, Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler Slot Deflector — — 1 Push and Rotate Slot IAMBI . '�•_ I�I� 'i i�� 'a!► I! 'al !I1 Sleeve V �� STEP 1. Align the slot in STEP 2i Push the rounded STEP 3'Pull the escutcheon STEP 4,Push and rotate STEP g Ti, minimize the escutcheon with the end of the slot against the away from the near edge the escutcheon onto the visibility of the slot horizontal surface of near edge of the deflector, of the deflector. Move the sleeve. In the escutcheon, the deflector as shown. Push the far side of the near side of the escut- position the slot escutcheon past the deflec- cheon over the deflector. at the topof the tor, toward the sleeve. sprinkler eeve. Figure 4: Adjustable Standard Escutcheon installation Form No. F_031993 Rev 15.1 Page 4 of 8 NIMICING® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS • The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com • • Sprinkler Base Thread Size Nominal Order Length Listings and Approvals4 Part No) SIN Style K-Factor° increment (Refer also to DesignCriteria on page 106e.) NPT BSP ® metric' Inches ® cULus5 NYC° VdS LPCB Egg la 08384U VK178 Adjustable 1° — 5.6 80.6 1/2" ® Al,A5 Al 0 -- 11.111111 16458U Standard — 25 mm ME 80.6 1/2" ® Al A5 — — as 08386U VK182 Adjustable 1" -- 80,6 1/4' 6.35 B2, B6 B2 1111 -- ©MI 16454U Recessed -- 25 mm 80.6 1/4" 6.35 B2,B6 -- a -- 111.111.111 0838816456U VK174 Plain Barrel 1" — 5.6 80.6 112" 12.7 A3 A4 _ �� 16456U -- 25 mm 0 80.6 1/2" ® A3 Approved Finishes and"A"Dimensions 1* -Chrome, or White Polyester'sprinkler with a Chrome, Brass, or White Polyester Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2'(38.1 mm to 1,156 mm) Approved Temperature Ratings 2 -Chrome, or White Polyester'with "A"dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 A-155°F(68°C), 175"F(79"C),200°F 3-Chrome,Brass,White Polyester',or ENT'with'A"dimensions 3"to 47"(76.2 mm to 1,194 mm) (93°C),and 286°F(141 °C) 4-Chrome or Brass with"A'dimensions 3"to 47"(76.2 mm to 1,194 mm) B-155 °F (68 °C), 175°F (79°C), and 5-ENT' 200°F(93°C) sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) 'Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes 'Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S-and Canada for Light Hazard occupancies only. 6 Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.15. 'cULus Listed as corrosion resistant. NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nlbco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Reauirements: Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- tion of NFPA 13 for standard spray sprinklers. • Limited to Light Hazard occupancies only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft.(1.8 m). • Deflector must be positioned between 4"and 6"(102 mm and 152 mm)below the ceiling.Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shalt be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. •The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed In accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards,whenever applicable. Form No. F_031993 Rev 15.1 • • Page 5 of 8 ® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Sprinkler Base SIN S le Thread Size Nominal K-Factor2 Order Length Increment FM Approvals* Part No.' tyle NPT BSP U.S. metric' Inches mm (Refer also to Design criteria glow.) 08384U — 5.6 80.6 1/2" 12.7 Al VK178 Adjustable Standard 16458U a 25 mm — 80.6 1/2" 12.7 Al 08386U5.6 80.6 1/4" 6.35 B2 VK182 Adjustable Recessed 16454U 25 mm 80.6 1/4" 6.35 B2 08388U - 5.6 80.6 1/2" 12.7 A3 16456U VK174 Plain Barrel a 25 mm — 80.6 1/2" 12.7 A3 Approved Finishes and"A"Dimensions 1`-Bright Brass,Chrome,White Polyester,or ENT'with"A"dimensions 1-1/2"to 45-1/2"(38.1 Approved Temperature Ratings mm to 1,156 mm) A-155°F(68°C),175°F(79°C),200°F(93°C),and 2*-Bright Brass,Chrome,Me Polyester,or ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 2mm to 1,207 mm) 86°F(141 °C) B-155°F(68°C},175°F(79°C),and 200°F(93°C) 3-Brass,Bright Brass,Chrome,While Polyester,or ENT'"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) 'Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the FM Approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. 5FM approved as corrosion resistant. NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nlbeo Model 5012.5-81 tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements; The Dry HSW Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide.For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including 2-0)and Technical Advisory Bulletins.FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to,but not limited to:minimum water supply requirements,hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflec- tor distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care,installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA,FM Global,LPCB,APSAD,VdS or other simi- lar organizations,and also with the provisions of governmental codes,ordinances,and standards,whenever applicable. Form No. F_031993 Rev 15.1 Page 6 of 8 NI I Kil NG" QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS • The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com For 'A' Dimension 1. Determine the distance from the face of the tee to the face of the finished wall. '.' .IlllllllllllluIlll 2. Round to the nearest 1/4' (6.35 mm) I between 3-1/4' C83 mm) and 47-1/2' (1,207 run/ Ceiling run/ NOTE The sprinkler will be recessed approximately Wall 5/16' (7.9 mm) with 5/8' (16 rim) horizontal °: adjustment available. 4' (102 mm) Minimum A _. 6' (152 mm) Maximums I il��� \ Few `('` 11 ,'IN�i I • 5/8' (16 mm) I�1,��,,,,,,, � J .. yli I w 3-1/16' r I 4 l. (77,8 nm) . .1 1 :I 11 Minimum wall opening: C " .- 2-1/8' (54 mm) diameter, r,.:I Maximum wall opening ` 2-1/2' (63.5 rim) diameter. Available Adjustment I-23/32' (43.7 mm> Minimum s May be allowed up to 18' (457 rim) for certain 2-11/32' (59.5 mm) Maximum FM Installations. Refer to the appropriate installation 5/16' (7.9 mm) Outward Adjustment standards, including NEPA 13 and/or FM Loss Prevention Data Sheet 2-0, 5/16' (7.9 mm) Inward Adjustment Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model E-1 Escutcheon Side outlet of—� �,,,e,w` Tee turned to 1-' 1 req'd angle for `{ �t Ma For 'A' Dimension slope of telling 1,111 / 1�► 1. Measure B Dimension from centerline of the `ly face of the tee to the horizontal centerline 1'°•- /'/ of the wall opening. Adjustable -4i4 / a Measure C Dimension from the centerline of AdgRmy er 1,► �/ the Face of the tee to the finished wall w R a Calculate 'A' Dimension using; A= tJBE+C 2 NOTE.A f Dimension eh provbe Approximately 1/4' w adjustment In either direction. Depth; I-I/16' <27 M) ir Adjus table 432 mn) /// CeKing ---I N Outer cup i////� T— Ii,t Deflector distance e-5/e' 4-6' (102 to 152 nn) �' IN( below the ceiling)* (66�") c1a2"^) Minimum wall opening. - When measuring for L 2-5/8' (66 mm) diameter. the 'A' Dimension, Maximum wall opening the exact deflector 3-3/4' (95 mm) diameter. C..Wall distance below the ceiling must be known C r May be allowed up to 18' (457 mm) I-1/16.1 for certain FM installations. Refer to (27 me) the appropriate Installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 6: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model G-1 Escutcheon Form No. F_031993 Rev 15.1 Page 7 of 8 N1K1NG® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-94.5-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcsl@vikingcorp.com For 'A' Dimension. 1ll111I11I1I111111111 1. Determine the distance from the face of the tee to the base of the sprinkler. Ceiling 2. Round to next highest 1/2' (12.7 mm) increment, between 3' (76.2 mm) and Wall 47' (1,194 mm). 4' (102 mm) Minimum 6' (152 mm) Maxlmumw A 2-3/16' - 1 (51 mm; ) N. ■1111011 5/8' (16 mm) Outside diameter: 1-5/16' (33.4 mm), (Same as 1' Do not exceed 6' (152 mm). (25 mm) Schedule 40 pipe. Do not recess wrench boss. w May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 7: Quick Response Plain Barrel Dry Horizontal Sidewall Sprinkler Top View-Dry HSW Sprinkler Side View-Sprinkler Cover 15610 NOTE:Shown with an Adjustable Standard Dry HSW Sprinkler.The protective cover may also be used with the Adjustable Recessed �f I Press the cover together or Plain Barrel style Dry HSW Sprinkler. until it snaps dosed. Ir0 W 1111h,, r — ii• J/f --- - After the sprinkler is installed, ♦ / carefully place the cover over J the dry sprinkler as shown. NOTE:Remove the sprinkler clip and cover before placing the system in service! Figure 8: Dry Horizontal Sidewall Sprinkler Cover Part Number 15610(shown with an Adjustable Standard Dry HSW Sprinkler) (Optional for temporary use with Viking Dry HSW Sprinklers until finish work is completed around the sprinkler.) Form No. F_031993 Rev 15.1 Page 8 of 8 NIKING® QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS • The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com 5-1m �)8' Seal the clearance space around the sprinkler barrel to avoid110 Maximum leakage of air Into the protected area and consequent formation of condensate around the sprinkler frame, which could inhibit ` operation or cause premature operation. Refer to Figure 10. • (130,230.2rrSI - If humidity and temperature „i„, � 1 NOTES To locate the differential causes condensation fill =__y 11 Deflector at deflector at the on the exposed dry sprinkler till = Maximum Distance Borrel, consider wrapping the IIII - From Vali maximum distance from PW 9 till the wall, with no exposed barrel with insulation, III! 13/16' adjustment avatable, foam insulating tape, or equivalent. IIII (20.6 mm) Ceiling order the standard IIIIdry horizontal side- Install the 1' NPT threaded Illi 4' (102 mm) Minimum wall sprinkler 1' end of the dry sidewall sprink- 6' (152 mm) Maxim/muler into the 1' NPT outlet of "I;; longer than the 'A' Sleeve finish dimension, mai a malleable iron tee fitting per 11111 \I / matches ANSI B 16.3 (Class 150) or cast _ escutcheon Iron threaded tee fitting per ?.�•i• --- k Up to 2' (50.8 mm) ANSI 16.4 (Class 125) only, frim-�_ 3-1/16' adjustment Is available. kSyII , f(77.8nm) ....,:.'N► — 5/8•J Minimum wall openings ��� i u / (15.9 mn) I 3-1/8' diameter 1-3/4'(44.5 nm) .1." L (79.4 mm) Maximum wall opening (Exposed ;;' 111 Minimum diameter' Barrel) "Il' 1-1/2'2-1/4'(57 mm). NOTES To locate the (38.1 mm) deflector at the diameter minimum distance from Exposed Barr-t" ' i• Ten mpe nture with no Ambient Temperature Surface •�- adjustmenthe t available, of Protected 40T/4'0150T/111'0160T/16tof the Watl order the standard Areae nt the Exposed 19rdR121ace Barrel 11111 Discharge End Lenpthewe Face of the wry horizontalile '- wall sprinkler 1' of the Sprinkler Tee to the Outer Deflector at shorter than the Surface of the Wnl! wry r,' Distance 'A' dimension, ,1r'.GW In.lee) In 4e1 From Wall 40'F(4'C) 0 0 0 30'F (-I'D 0 0 0 wMey be allowed up to 18' (457 mm) for certain FM POT (-7•C) 4 (100) 0 0 Installations, Refer to the appropriate installation standards, 10'r (-12'C)'e<203) 1(25.4) 0 Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0, 0'F(-I8'C) 12(305)3(76) 0 iewThe protected area refers to the area below the ceiling, -10'F<-23'014(356)4(102)1(25.4) The ambient temperature Is the temperature at the discharge end of the sprinkler. -20T (-29'014(356)6 (152) 3 (76) For protected area temperatures that occur between the -30'F (-34'C716(406)8 (20374 <102) values listed, use the next cooler temperature. -40'F(-40'C)10(457)I (203)4 (102) wwwThe minimum required barrel length is not the same as the 'A' dimension. -50T (-46'C)20(508)10(254:6(152) Refer to Figures 3, 5, and 7 for the 'A' dimension. -60T (-5re)20(508)10(254)6 (152) Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler Is Shown) t 1 Seal Seat (or equivalent ; : j method) II' ` III�I .I . L IIS II! 1 ■I o k Clearance $ j Opening k Insulated $ Insulated $ Wall Wall Dry Sprinkler Seal on the Exterior of the Wall Dry Sprinkler Seal Within the Wall Figure 10: Dry Sprinkler Seal(Adjustable Standard Dry HSW Sprinkler is Shown) Form No. F__031993 Rev 15.1 DATE TIME CITY OF ORONO CALLED IN )1/)i/0- IY✓", INSPECTION1410TICE SCHEDULED I/21/11- c:,800 PERMIT NO.40I 9- —cY 4'5(10' COMPLETED 114- i 6/gTh ADDRESS 7 1- 6r s- r OWNER tA/oo ilDLA kin TELEPHONE NO. CONTRACTOR L; �� SG J� �s rt 0.6 4e� ko— DESCRIPTION w 5 ` ^ I W ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING C 0 FOUNDATION WATERPROOF 0 PLUMBING FINAL ❑ TREE REMOVAL ❑ RADON SLAB 0 MECHANICAL RI 0 SITE INSPECTION ct 0 FRAMING 0 MECHANICAL FINAL 0 RATED WALLS 1, 0 INSULATION 0 WOOD BURNER/FIREPLACE 0 COMPLAINT Q 0 FINAL 0 WATER HOOK-UP 0 FOLLOW-UP W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP 0 FOUNDATION/REMOVAL ❑ DEMO-SITE 0 SEPTIC INSTALL OWNERICONTRACTOR TO MEET YOU:r?'.YES_NO (#)• COMMENTS: ac CC O cC OO W 2 W W Cc J X• 'WORKSATISFACTORY:PROCEED ❑PROJECT COMPLETE Ct W ❑CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY ✓ BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: Inspector. c �^^e.- V,�,. frEy l\ White Copyllnspector's File Canary Copy/Site Notice DATE TIME CITY OF ORONO CALLED IN .%L V /Oak J INSPECTION NOTICE SCHEDULED 1/21/ff I J c ' PERMIT NO. a'O i ' 011-1519 COMPLETED ADDRESS ?Z ( / OWNER G✓v+c-Ul.✓A-r-- TELEPHONE NO. C01/-1'30-73.1 ir CONTRACTOR I .56_,./✓ '.c_ P�� DESCRIPTION /�- - W ❑ FOOTING 0 DEMO-FINAL 0 SEPTIC FINAL Q ❑ POURED WALL 0 PLUMBING RI 0 EXCAV/GRADING/FILLING Q 0 FOUNDATION WATERPROOF 0 PLUMBING FINAL 0 TREE REMOVAL Z ❑ RADON SLAB 0 MECHANICAL RI 0 SITE INSPECTION Q 0 FRAMING 0 MECHANICAL FINAL ❑ RATED WALLS Is ❑ INSULATION ❑ WOOD BURNER/FIREPLACE 0 COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP 0 FOLLOW-UP ❑ AS BUILT-SURVEY 0 SEWER HOOK-UP ❑ FOUNDATION/REMOVAL ..t ❑ DEMO-SITE El SEPTIC INSTALL 2 OWNER/CONTRACTOR TO MEET YOU: YES_NO ccl COMMENTS: cc CC O CC O W Q 2 W W CC IQ0 WORK SATISFACTORY:PROCEED ,PROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY OO ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY C.1 BEFORE COVERING PERMANENT O CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR El CITATION ISSUED O INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlContractor on site: Inspector: White Copyllnspector's File Canary CopylSlte Notice