Loading...
HomeMy WebLinkAboutRe: soils testing �Q�Np E N T T�S,, 20 � �y� 337 31ST AVENUE SOUTH • PO BOX 325 • WAITE PARK, MN 56387 . OFFICE: 320-253-4338• FAX: 320-253-4547 ��cyNo��t'''��� � May 18, 2006 Mr. Jerry Nelson M A B Homes 2525 Nevada Avenue Minneapolis, MN 55447 RE: 06-158 Report of Soils Observation & Recommendation for Foundation Drain Design Single Family Residence 3619 North Shore Drive, Orono, Minnesota Dear Mr. Nelson: As requested by you, Independent Testing Technologies has recently conducted a visual observation of the house being constructed in Orono, Minnesota. The purpose of our observation was to assist you in evaluating the potential impact of groundwater on the below grade foundation and provide recommendations to preclude basement water problems. DESIGN INFORMATION The proposed single family residence to be constructed is a two story home with poured foundation and an attached garage. The house dimensions are 50' x 30'. The lowest floor slab is at assumed elevation 100. We have assumed a 2,000 pound bearing capacity for this structure. SERVICES PERFORMED Our observation was conducted on May 17, 2006. At that time test pits were excavated in the area that the house will occupy. These test pits were approximately 3 feet below the existing grade. These test pits encountered 8 inches of soft, grey lean clay (CL) underlain with 2 1/2 feet of brown, medium dense, mottled, silty clayey sand (CL-ML). These silty soils were underlain with a grey, wet poorly graded sand (SP), and poorly graded sand with silt. Hand auger probes revealed these water bearing sands down to a termination depth of 5 feet below existing grade. Estimates of soils density were based on the resistance of the hand auger probes. Soil classifications were determined in accordance with the American Society for Testing and Materials (ASTM) procedures by examining the hand auger probe cuttings. An assessment of the site grading and drainage was made. The building site appears to be poorly drained. The lot appears flat. Grading work will be needed to provide positive drainage away from the building. Water was encountered at a depth of 2 1/2 feet below existing grade. We understand there will be a minimum of 3 feet elevation difference between the lowest floor and groundwater level. We recommend that the soils below the footings and column pads be excavated one foot below footing grade and replaced with free drainage course stabilizing aggregate (3/4 inch to 1 1/2 inches rock) Based on the results of our visual observation, it appears that the groundwater may have an impact on below grade walls on the site. However, we recommend that an exterior perimeter foundation drain be installed. The foundation drain should consist of a 4 inch diameter perforated flexible "sock-type" p.v.c. pipe surrounded by rock and wrapped in filter fabric. We recommend that the drain discharge by gravity at a maximum of 5% slope from the house to daylight. An interior sump pump could also be used to discharge water from the foundation drain. Roof downspouts should be extended to outfall past the backfill. In addition, the below grade walls should be damp proofed with bituminous material, 6-mil poly, or approved damp-proofing material from the top of the footings to the ground level. A minimum of 4 inches of clean, washed sand should be placed beneath the floor slab to prevent capillary rise of moisture. The finished exterior wall backfill should be placed so that any surface water will drain away from the house at a slope of 5%. SUMMARY Based upon the result of our observation, it appears that groundwater may have an impact on below grade walls on this site. However, site grading, damp proofing, and exterior foundation drains are required to alleviate any potential problems. It should be noted that standard penetration test borings with power equipment were not taken to evaluate the soils at depth. However, visible soils and the results of the hand auger probes indicate that the risk of detrimental settlement due to unsupportive soils at depth is minimal. In our opinion, it is reasonable that this risk be assumed by the owner. It should also be noted that fluctuations in the level of the groundwater can occur due to Report of Observation L T.T.Project #06-158 May 18,2006 Page 2 variations in rainfall, temperature, spring thaw, and other factors not evident at the time of our investigation. Mr. Nelson, it is our pleasure to work with you on this project. Please feel free to contact us if you have any questions or need additional services. Sincerely, ��/.i:��G/ (� (/l Mitchell A. Lycnh, Patrick A. Jo son, P.E., Project Manager Geotechnical Division Manager 06158m1(drain) Report of Observation l.T.T. Project #06-158 May 18, 2006 Page 3