Loading...
HomeMy WebLinkAboutrange hood report �� NARQIN ! FIRE EQUIPMEN�T COIVIPANY ST. PAUL, MN. 612-483-6631 • ❑�FARGO, N.D. T01 -235-4224 RANGE HOOD F� RE SUPPRESSION SYS�'EM I NSTALLATI ON / MAIIVTENANCE REPORT ❑INSTALLATION �SEMI-ANNtJAL MAINTENANCE ❑ANNiJAL MAINTENANCE Date of installation/maintenance ,1,2� '��� Time in ,��� Time out 1 . Name/phone of facility ' B -e 2. Address of facility o� �.d L�. r�` ��2� ' 3. City, state, zip Lc�a 4 . Mfg. of system ANS �_ KIDDE � RANGE GUARD OTHER S . Dry Chemical Wet Chemical � Cartridge Operated 6. Where system is located /�/�jr�-1-i p �p 7 . Model of system RF �� , .���' S Hydro date � � 8. Last maint . date;�'�_ by ��✓���`n_f �cr,� Co. 9 . Manual release(s) operable? �Y.e�� ❑ No; Automatic relea e operable? �Yes � No 10. Mechanical fuel shut-off device(s) operatior,al? �es � No ❑N/A 11 . Electrical fuel shut-off device(s) operational? ❑Yes ❑No�N/A � �r 12. Do devices in 10/11 shut-off all fuel under hoods? y�'Yes No /� �/v JL'' � 13. Fusible links, how many?�_360° ; 500° Last replaced �._.)t(yt� 14 . Nozzles checked for proper coverage and clearance? �1Ces ❑ No 15 . Nozzle quantity/types �`Duct / Plenum UP Broiler Char Broiler Regular surface Other 16. Cyl . Weight(s) � Cyl . pressure Cart . weight �6 l� p� 17. Do exhaust fans appear to operate properly? �.es [] No 18. Is hood clean? ;�Yes ❑No; Are filters clean? �Ces ❑ No 19. Is sketch of hood and appliances on back of report ith dimensions? �Ye s � No � 20. Does system meet N.F.P.A. 17 and 96 codes? ,�Yes [� No 21 . Nas system been sealed and tagged properly? ,�i�s � No 22. Does the hand portable fire ext. in kitchen meet N.F.P.A. l0A? �s (] No 23. If "no" answers appear above, is non-compliance tag attached? [] Yes ❑ No 24. Comments , Recommendations - K��.Q n�v � �n �� Installer-Inspectors Signature Customers Si�nature Printed r'ame ' � tVARDINI FIRE EQUIPMEN�T COMPANY �ST. PAUL, MN. 612-483-6631 • ❑�FARGO, N.D. T01 -235-4224 RANGE HOOD FlRE SUPPRESSION SYSTEM INSTALLATION / MAIIVTENANCE REPORT �INSTALLATION �SEMI-ANNUAL MAINTENANCE ❑ANNUAL MAINTENANCE � Date of installation/maintenance /�-- " � �� Time in �� O Time out //.x��J 1 . Name/phone of facility /�r`nne�"e;�v�� n e.✓t�.P �o� �! e lqt'-�-5 2. Address of facilityo'Zo��p /V�r�ts�inr� l,r,`J� ����w��S/� ��''2 `1r��' 7.�G/ 3. City, state, zip L�.� � 3� � 4 . Mfg. of. system ANS �_ KIDDE RANGE GUARD OTHER S . Dry Chemical Wet Chemical Cartridge Operated 6. Where system is located �G�C � O�� • 7. Model of system f ' �, � Hydro date �'� 8. Last maint . date1�u��- �'c� by ' ,� Co. 9 . Manual release(s) operable? ;�Yes ❑ No; Automatic release operable? �Yes � No 10. Mechanical fuel shut-off device(s) operatior,al? �Yes � No ❑N/A � / 11 . Electrical fuel shut-off device(s) o perational? ❑Yes ❑No„�N/A � �!� 12 . Do devices in 10/11 shut-off all fuel under hoods? �Yes ❑ No 13. Fusible links, how many?_�360° ; 500° Last replaced �c.�►�t. Q �� 14 . Nozzles checked for proper coverage and clearance? [�Yes ❑ No 15 . Nozzle quantity/types Duct Plenum UP Broiler Char Broiler o2 Regular surface Other 16. Cyl . Weight(s) �i� � ( - Cart. weight ���r2 dZ-- 17. Do exhaust fans appear to operate properly? ,�Yes � No 18. Is hood clean? �es ❑No; Are filters clean? �Yes ❑ No 19 . Is sketch of hood and appliances on back of report with dimensions? Ye s � No 20. Does system meet N.F.P.A. 17 and 96 codes? i�Yes No 21 . Has system been sealed and tagged properly? �'Yes ❑ No 2,2. Does the hand portable fire ext. in kitchen meet N.F.P.A. l0A? ,�yes � No 23. If "no" answers appear above , is non-compliance tag attached? � Yes ❑ No 24 . Comments , Recommendations /T ��5���i.� ^ ����, (''lr-1�ean�. Installer-Inspectors Signature Customers Si�nature Printed 'Name