HomeMy WebLinkAboutplan review checklist S w � • � � � � • � � • ' • Note:code references Minnesota Rules and the 2000Internationa[Building Code The following is a partial summary of plan review for non-residential structures and should include,but not be limited to the following items: Complies Zonin : Yes No N/A Site Plan-Submitted ✓ Front Yard Set Back: ✓ Rear Set Back: ✓ Side Set Back `� Conditional Use Permit � New Building Size Location of Additional Buildings � ✓ Location of Well r��^' w�-�r�� Location of Septic � Shoreland Setback � High-water Elevation � Notes Construction Documents Complete Submittals MN Rules 1300.0130 ✓ , Permit Application Complete 1300.0120 � Construction Submittals Signed By Design Professiona11300.0130 sub 1 f Special Inspection Agreement Submitted Geotech Report �Energy Calculations Notes Code Overview Use & Classification ✓ Building Classification 302.1 � Incidental Use 302.1.1 & Table 302.1.1, 302.1.1.1 ✓ Mixed Occupancies 302.3 � Separated or Non-Separated Use 302.3.2 302.3.3 � Occupancy Separations Table 302.3.3 . � Complies Fire Resistive Consfruction (cont.) Yes No N/A Combustible Projections 704.2.3 / M1V Rules 1305.0704.2.3 ✓ Fire Resistance Rating Exterior Walls 704.5 ✓ Allowable Area of Openings- Exterior Walls 704.8 Table 704.8 ✓ . Allowable Area of Openings- Sprinklered Exterior Walls 704.8.1 Table 704.8 � Pazapets 704.11 ✓ Opening Protection Doors, Shutters & Exterior Walls 714.2 Table 714.2 ✓' Fire Walls (Former Area Separation Wall) 70S Definition 702 ✓ Fire Walls Fire Resistance Rating Table 705.4 r/ Horizontal Continuity 705.S ✓ Vertical Continuity 705.6 ✓ Opening Through Fire Walls 705.8 Table 714.2 ✓ Fire Barrier(Former Occupancy Sepazation) 706.1 Definition 702 � Fire Barrier Fire Resistance Rating 706.3 Fire Barrier Continuity 706.4 ✓ Openings Through Fire Bamer 706.6, 714.2, 714.3 � � Fire Partitions Where Required 708.1 � _ Fire Partition Fire Resistance Rating 708.3 � _ Fire Partition Continuity 708.4 Horizontal Assemblies General 710.1 � Horizontal Assemblies Fire Resistance Rating 710.3 � Horizontal Assemblies Continuity 710.4 ✓ Penetrations—Definitions 702 � Penetrations 711 � Opening Pmtective 714 � Duct Openings General 715.2 � Fire Dampers Fire Protection Rating Table 715.3.1 Fire Damper Actuation 715.3.1.1 � Smoke Damper Rating 715.3.2 Smoke Damper Actuation 71 S.3.2.1 � Fire Damper Smoke Damper Where Required 715.5 � Fire Blocking 716.2 � Draftstopping Floors 716.3 � Draftstopping Attics 716.4 � Notes N o� rl�'► ���e � �;�,�-�� ! i Complies Code Overview ��ont.� Yes No N/A Building Occupancy Classifications �/ Assembly 303 ✓� Business 304 � Educationa130S ✓ Factory 306 '� Hazardous 307 `� Mercantile 308 � Residentia1310 MN Rule 1305.0310 Storage 311 ✓ Utility 312 � Notes General Buildina Reauirements Scope MNRules 1305.0501.1 ✓ Definitions 502.1 ✓ Basements 503.1.1 ✓ Basic Allowable Height &Area Table S03 � Height Modifications 504.2 Multi Story Area Increase 503.3 � Area Modifications 506.1, 506.2, 506.3 —� �, Unlimited Area S07 Notes Tvpes of Constructton Minimal Requirements 602.1.1 ✓ Combustible Material Allowed ✓ In Non Combustible Construction 603 / Fire Resistance Rating Table 601 w/footnotes ✓ / Exterior Wall Fire Resistance Table 602 w/footnotes �/ Notes Fire Resistive Construction Fire Area Definition 702 ✓ Fire Separation Distance Definition 702 � Exterior Walls 704 '� Projections 704.2 '� . • Compiies Fire Profecfion Svstems Yes No N/A Sprinkler Supervising Station Definition � 902.1 901.6.1 �� Fire Area Definition 702.1 r�' Sprinkler Systems Where Required 903.2 r � Sprinkler Systems Required @ Basements � b � 903.2.12.1 `� ,� Additional Required Suppression Systems Tabde 903.2.1 S Sprinkler Exempt Locations 903.1.1.1 Fire Alarm&Detection System 907 MNAmendments Notes Means of Eqress Occu ant Load 1003.2.2 Table 1003.2.2.2 ✓ P Increased Occupant Load 1003.2.2.4 _� Egress Width 1003.2.3, Table 1003.2.3 � Ceiling Height 1003.2.4 Exit Signs Where Required 1003.2.10.1 ✓ Means of Egress Illumination 1003.2.11 ,s_� � k^-� ' U ST Illumination Emergency Power 1003.2.11.2 ��� Guards 1003.2.12 MNRules 1305.1003.2.12.1 � Doors 1003.3.1 Size of Doors 1003.3.1.1 � Door Swing 1003.3.1.2 � Landings @ Doors 1003.3.1.S Locks & Latches 1003.3.1.8 Stairways 1003.3.3 MNRules 1305.1003.3.3.3 Stairway Landings 1003.3.3.4 '� Handrails 1003.3.3.11 MN Rules 1305.1003.3.11 ✓ Handrail Height 1003.3.11.2 � Handrail Continuity 1003.3.11.4 Handrail Extensions 1003.3.3.11.S ✓ MNRuIe 1305.1003.3.3.11.5 Exit Access General 1004.1 ✓ Exit or Exit Access Doorway Required 1004.2.1 Table 1004.2.1 MNRules 1305.1004.2.1 _� Separation of Exits or poorway's 1004.2.2.1 �/ Egress Through Intervening Rooms ✓ or Spaces 1004.2.3 Exit Travel Distance 1004.2.4 Table 1004.2.4 � Common Path of Egress Travel Definition 1002 � Common Path of Egress Trave11004.2.S . , � Complies Meons of Ecaress (cont.) Yes No N/A Corridor—Definition MN Rules 1305.1002 ✓ Corridor Where Required Table 1004.3.2.1 � Corridor Construction 1004.3.2.1 Table 1004.3.2.1 �� Comdor Continuity 1004.3.2.S Notes Exits General 1005.1 ✓ Miaimum Number of Egits 1005.2.1 Table 1005.2.1 � � Buildings With One Exit 1005.2.2 Table 1005.2.2 Vertical Exit Enclosures IOOS.3.2 � Exit Enclosure Definition 1002 ✓ Exit Enclosure 1005.3.2.S.1 ✓ Exit Passageway Definition 1002 �_ Exit Passageway 1005.3.3 ✓ Horizontal Exit Definition 1002 �_ Horizontal Exit 1005.3.S � � Exit Discharge Definition 1002 � Exit Discharge 1006.1 Notes