Loading...
HomeMy WebLinkAboutseptic info . o �'` � .. . .. .. . . � �.Fr�;Y� "4-...�,. � . - . � � � . . Io , .,` ,. ... .. . � � .. . ... __... .. .. . .. .. . 3r tir;. . ... . .. � � .� . . . � ���,. �� ��.� , � . CITY of ORONO '� ,� 'a;`�A`t���`r S+: . � . � ���•, et. ,;��; , ��, ! Municipal OfFices � ,� ,:,3;�:,:;.'�'.;�:s�.�.�r,, �j � � .,.,;.�°.:;��,� Street Address: °15a'a4 q"y 6� � Mailing Address: 9�ESxp4 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 To Current Owner: Address: ���� N�(fi� �'�t n., City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. � The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. � "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cuaent Orono �`•� Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eulier,and which is not failing or an imminent flueat to public heatth or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;en ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet ail the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than thra feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 6 Tank inspection indicates: . 5 Pumpout not needed at this time. , • � Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ��-7"b� �• Make sure seatic tanks are pumaed throu�h manhole and not throush white insaection aiaes. This allows for the aroper cleanin¢ Keep water softner and iron filter discharee out of seatic svstem to prolon¢life of dramfield. Ask oumoer to test alarm float to verifv slarm is still workin¢in vour house The alarm warns owner that seata¢e is a_bout to backuo mto basement. 7 Inspection risers missing-tanks could not be inspected. Inspect►on risers(4"d�a.pipe)must be mstalled in each tank. If tanks have not been pumped out within the last three yeazs,they should be pumped out now. DRAINFIELD CONDITTON 8-10 : � 8 Drainfield is dry,no surfacing evident. " 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. . - .p� - ��\� "^- �,� 1 ks �k n . oo �� , . - ..�. . CO1VI1�IE1�iTS: � . Y_ .. .,�: a n, ., . , , .. .,:. ,_� ._ . _ ,..: . �.�«� +� ;. . �P . . _ .. � . v�-r-�c�' 'L.cy o s- . . q--�-6�1 �'' r``� ` I ` � ;Dat�.of I�lspeciion �'�� MaEt Bo{ter�an -'Septic System Inspectar � - ' ' � � Y 'M1 . ;3" - :j .. . � � . T ' ;� �': 6� �' t .I �i � . , �:� � •, b , . ., . .. � � g �� i Nc�1�: l Cke t�vent,��ac t�tis itt�pectton r�iort is used ta�at�s�y the iec�irirecntnts�or a nlort��ge or oE�3er trannsfef of propecry.be advised t1�at this report do�s �. !,� � nc'��uti�,nte��r e�tify. at�n e�astin�systee�m vv��1 c udnt� td �unetton qrop�ly t��t �5 m�rs�y ai� opinion of the adequacy af t�he svst�m under currznt m �� � 4� � �� t ��, � ,��cti�tio�6 ot�he ik��ttt�a n��' �.�� ..��� �. . � � ,-.'� ,� �� �- . .:� u.�� .., a�. .�,�,N�, ,U �, ,_.. ., . ;� �># �o�. 0..:� O . . ,� ���;��;�- - CITYof �RONO � � ;�� � x�i �:�°: ,ti,� .Munlcipal Of�'ices r 11 y��',.� i�'�'YG ' . Street 1Wdress: Mam . n � ESSOg 2150 Keliey Parfcway P.O. Box 66� . - O�ono, MN .55356� .� Crystai Bay,.MN 55323-0066 . 95a-�49-y600 � To Cutrent Owner: Address: : . �7 c�� No C'� �i��. �� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatmeat system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-31: �, 1 "CODE SYSTEM"M ISTS which meets alt the location.duign and construcdon standards of the ewrent Orono MunIcipal Code. �"COMPLIANT SYSTEM" M ISTS which dou not meet a11 the loeation.daign and construet3on standards of the wrrent Orono Municipal Code but doa meet the three foot separation rcquinment or two foot requirement for systems installed 1996 or earlier.and which is aot failing o� an imm3neat threai w public health or safery. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a daignated(00-year tlood plain,aay IS?S which may . or may not meet al!the locatton.design.or consuuction standards of�e aurent Orono Municipal Code and which ts failing for any reawn;and any ISTS with less than three feet of unsaturated soil or sand behvicen the disuibution device and the 1'uniting soil eharacteristia. �'ANK CONDITION l�-:71: � _ � Tank inspectioa indicates: � . . _ . . . 5�Pumpout not needed at this time. � 6 Sepdc tanks must be pumped out this yeaz (city code requires tanks to be pumped out once every 3 years. Tank was last pumped 5'7—b t �, . �Viake sure seaiic tanks are aumoed through manhole and not throu�h white inspection oines This allows tor the arooer cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. RAINFIELD CONDITION -�lf : ,� 8 Drainfield is dry,no surfacing evident. . 9 Some evidence of surfacing,not critical ye� ' 10 Dninfield'u saturated and visibly dischargina untreated eE�luent to the surface. Contact the Ciry Inspector � � immediately.Repairs must be completed within 90 days. . COMt�NTS: Q f�.;�-:cl�� �� �c�1 �-_.L -f-�^�lS � C�c�k ��� � -�.� —D�— �ctoC Date of Inspection Matt Bolterman- Septic System Inspector Note:In the event that this inspection nport ts�ued to satisCy the requinments for a mortgage or other transfu of property.be advised that this rcport doa notguaranue or artiFy that an existing system will continue to funetion propedy.but ts meceiy an opinion of the adequary of the system under cumnt eondidons bi4ed on the avu'labie infomwtion. � \� � �`\`\' �'.���, O � ,;:,�:::::.;,-. �+��� Of �R�1�� �.j+T ti`�;�'xm;r�; _ ' �/ r'� �v�''�� ;�, � :, Municipal Of6ces 1\�+• �� +��' kJ �'^ ti ' Street Address: Mailing Address: , �. � ` % �\� '� �, �,� �•.'��??�° G i ���• �����'"'� ' �, ' P.o. BoX ss , < �� .,, �r. �� •.�� <q .�.'��`: '��; 2750 Kelley ParkwaY . ��. kESKO %� Crystal Bay, MN 55323-0066 ;� Orono, MN 55356 To: The Cunent Owner of Address o 7v2 `� ��'�� � ��" City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The.onsite sewaje treatment system at the above address has been inspected and the following is known about the system. A sketch of the known cornponents of the system is available for most properties at the Orono City Hall. Imminent Public Health Thi-eat Yes No � If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be broujht into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identif' as Non-Compliant Yes N� If yes, system must be brouaht into compliance by: December 31, 2007 December 31, 2010 � Other Septic Tank(s) mp out Needed Yes l�To The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on �—'1 -v 1 . The tank(s) should be cleaned through tlie manhole and not through the inspection pipes,tlus allows for proper cleaninQ. Comments: � �, - � � Inspector: � Date of Inspection Telephc,ne (9=21 249-=ifiOU • Fa� (9�2i 249-4616 . �o� / o � o _�.� , ;p � ,,A ��;=�:.,y ,, CITY of ORONO �`'� 4 "� d€ '�� l� MunicipalOttices �`�� � ;;;.�, � ,,��•_`v��j�' . Street Address: M�ilinQ Addroas: �'$+ggOg' � � 2750 Keiley Pa�kway P.O. Box 66 � Orono, MN 55356 Crystal Bay, MN 55323•0066 August 10, 2000 Benjamin Field 1729 North Farm Road Long Lake, Mn 55356 Dear Mr. Field: An inspection of your septic system was conducted on August 9, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout not needed at this time. The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built drawing is enclosed showing the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. Res ectfull ' � ��� Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does no guarantee or certify the eaisting system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www ci.orono.mn.us �°� . 0 0 ,,��j�� ,� CITY of ORONO � ��� �'��. ,�l4 Municipal Offices '� �� ,,��=;���� �`� , � ��,���.�G Stroet Address: MailinQ Addrou: Egg04' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 � � Owner: n �� Address: 1729 North Farm Rd. Permit #'s: 7108 Dates: 8/19/B3 Contractors: Hoff Plbg. (This is f,x] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance witkt previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [x] or ia not [ ] identified under this septic systam. If the saturated soil level is not identified, thia classification ia aubject to reviaion.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] xater tight or the condition is �] unkno�vn. If the tanks ara not confirmed to ba vratertiqht, this classification is aubject to revision.) INFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 2 feet and the system is non-compliant. City Codes do not require repair or replacement of the septic system at this time. ��.�`�g Date of Inspection t' ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existinq system will continue to function properly, but indicates the operation of the system under current conditions. . Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATl�NT � � IN3PECTION REPORT ti ���kESH���G Owner• �Yl A1'1')IYl 1�iQl� Address: �7s�/ /�bY711 �Y/Y� . Permit #`'s: Dates: �1 I—�� Contractors: �p 11 City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is D(1, an existing system [ ] new construction> SYSTEM CONFORMITY (1-3): � � "COOE SYSTEM"-A system which meets all the location, design, and construction starxiards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the • current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of. the entire current sewage input without discharging any pollutants into ground or surface Waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting sotl characteristics. (The limiting soil characteristic D�7.has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi'�ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection irxiicates: 5 Pumpout not needed at this time. b Solids accunulation in tanks indicates they should be punped out this year to help prevent future problerr�. 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next Exanpout. If tanks have not been punped out within the last three years, they should be punped � out now. Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids accunulation). If tanks h ve ot been out within the last three years, they should be punped out now. DRAINFIELD CONDITION (11-14): Dr field inspection indicates: �Drainfield is dry, no surfacing evident. �� Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irmiediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbecks,etc.): POTENTIAL FOR SYSTEM FAILURE Cdepends on soils.water table,etc.): � COMMENTS: Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location arid purt�ing records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner M On�the Noyth Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER � � � ADDRESS �/� �/u� l��• PERMIT NO.'S. ��Da C' ' ' �� � � DATES � CONTRACTORS City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite se treatment system at the above address has been inspected and appears to fall into the category checked below. (This is ❑ an existing system ❑ new construction) ��71 � Meets or exceeds current City standards in all respects releting to design,construction,and location.Appears to be operating �d properly. � 2 Dces not meet aIl current City standards for new co�struction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does�ot rrfeet current City standards in many respects relating to design,eonstruction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisence.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.You�contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Ta�k inspection indicates: � Inspection pipe is located directly over tank baffle.(Dces not ❑ Pumpout not needed at this time. � give accurate measurement of solids accumulation.) If tanks ❑ Solids aecumulation in tanks indicates they should be pump- have not bean pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a criticel level, Tanks , Drainfield inapection indicates: should be pumped out as soon as possible. ,� Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanka must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tsnks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) Adequate ❑ High water table �Low Fair O Lot size O Medium ❑Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage O System is causing visible s rface i h �ge. � _`, i / / COMMENTS: �` r � �` � �S 'g3 P �-/�'� Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the reGuirements for a mortgage or Uther transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinio�of the adequacy of the system under current conditions based on the available information. This report must be kepron the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner CITY OF ORONO � O� Municipal Offices O O Post Otfice Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE 3EWA(�L TREATI�NT INSPECTION REPORT ti ti ��9k o4�G EsH Owner• � �iU� Address: � • Permit #�'s: �� Dates:_ L���1 Contractors: r City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected end appears to fall into the category checked below. (This is f,,� an existing system [ ] new construction) S STEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewege input without discherging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet atl the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which �y or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil charecteristic [�has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDIT[ON (5-10): T� inspection indicates: 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be punoed out this year to help prevent future problems. 7 Solids accunulation in tanks is et a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar$e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each tank at next p�n�out. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is lxated directly over tank beffle (does not give accurate measurement of solids accunulation). If tanks have not been punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION C11-14): D�field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated end visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloce,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table,etc.): COMMENTS: Date of Inspection p ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortg_ e or other transfer of property, be advised that this report does not guarantee or cert�fy that an existing system w�l continue to f�ti� properly� but is merely an opinion of the adequecy of the system under current conditions based on the available informat�on. . This report must be kept on the premises with the system locetion and Fxanping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ��EL'� ADDRESS �7�/ /VL F'�� �p PERMIT NO.'S. ��08 DATES g��� 8 3 CONTRACTORS ��F City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the ab�ove addrQss has been inspected and appears to fall into the category checked below. (This is Id an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � � 3 Does not meet current City standards in ma�y respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan rhust be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) �nk i�spection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not Pumpout not needed at this time. give accurate measurement of solids accumulatio�.) If tanks ❑ Solids aacumulation in tanks indicates they should be pump� have not been pumped out within the last three years,they ed out this year to help prevent future probfems. should be pumped out now. ❑ Solids accumulation in tanks is at a criticel level. Tanks D infield inspection indicates: should be pumped out as soon as possible, Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. O Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risers (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped put now. O Drainfield extent and condition unknown. , iITE CHARACTERISTICS: 4niting Site Factors Potential for System Failure ite Capabilities for � Slope ( pends on soil types,water ure Expansion 1 Soil � ta e,and system condition) , �Adequate GH�gh water table � Low ❑ Fair �ot size ❑ Medium O Poor � �ke,wetland,or stream ❑ Migh , ❑ Inadequate �nage ❑Sy$tem is ceusing visible surface discharge. COMMENI __----. _.__--� -,,3-- � 3 - 8 7 Date of In ction . Septic System Inspector Note: In the event t�� �is report does not gl�s inspection report is used to satisfy the requireme�ts for a mortgege or other transfer of property,be advised that of the system under cuttee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy •onditions based on the available information. �is report must be kept on the premises wittr system location and pumping records. \ E COPY/Inspector's Fite GOID COPY/Homeowner � On the North Shore o f • Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 � � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ADDRESS / � �� N��� �'� �� PERMIT NO.'S. � DATES � ����3 CONTRACTORS TT-Sz�� ��� � City Ordinance No.210 requires that each on-site sewage treatment system in Oro�o be inspected on a regular basis.The on3ite sewage treatment system at the above address has been inspected and appears to fall i�to the category checked below. (This is ]IQ an existing system ❑ new construction) � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creati�g a safety hazard,or is otherwise creating a public�uisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil teating will usualty be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) T k' pection indicates: Inspection pipe is located directly over ta�k baffte.(Dces not �umpout not needed at this time. grve accurate measurement of solids accumulation.) If tanks ❑ Solids aecumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Orain 'eld inspection indicates: should be pumped out as soon as possible. ,�Drainfield is dry,no surfacing evident. ' ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risera (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and conditio�unknow�. SITE CHARACTERISTICS: Li iti g Site Factors Potential for System Failure Site Capabilities for �Slope (depends on soil types,water Fu ur Expansion ❑ Soil table, nd system condition) �Adequate ❑ High water taWe �Low ❑ Fair ❑ Lot size Medium ❑Poor ❑ Lake,wetla�d,or stream ❑ High ❑ Inadequate �Drainage ❑System is causing visible surface discharge. COMMENTS: �P�-S' � 6�,1/�I ��D �n�.��p'lD� � -�g- � Date of Inspection Septic System Insp Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to functio�properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner