HomeMy WebLinkAboutseptic info // O
1 � �
� 0 \
�' `�:- - � CI
' ��� � `' TY of ORONO
,, -- _ .�
,,,� A�.::;t�^� _ ��i
,�"�+,� ,!'.�..���`��< -'�~ ti/; Municipal OtTices
'ti, '
\\� �9� ``.�?�O4�G� Street Addross: MailinQ Address:
EgK 2751 Kelley �arkway �.0. 9ox 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address:_�y.S No�� �tM n
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY 1-3 : I
1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the curtent Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and conswction standards of the current Orono Municipa!
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failins or
an imminent threat to public health or safery. -
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason_and
any IS'fS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): C7
Tank inspection indicates:
5 Pumpout not needed at this time.
QSeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank w-as last pumped ).
Make sure septic tanks are oumned through manhole and not through white inspection pipes This allows for the
proaer cleanmg. Keeo water softner and iron filter dischar¢e out of se�tic svstem.
7 Inspection risers missing-tanlcs could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tanlc. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector
immediately. Repairs must be completed within 90 days.
COMMENTS: �ouc•C� Ip0 d�. PUrn S� �.L a--at�Y�S �c�C�
�-\�� S���c Oc� 5 cc�� ar.� ,
56--�6-0"3 p��'
Datz of Inspection Matt Bolterman - Septic System Inspector
Note: [n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantze
or certify that an exisung system will continue to function properly,but is merely an opinion of the adequacy ofthe system under current conditions based on the available
infortnation.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
._ _..___
.�=�o `
,';` � � ''ti`.,
,, o 0��1
'� �� C ITY o� ORONO
i� „ r � ,I
�`�II, '"� '''` , ',.' �, ;! Municipal Offices
,��,� �, -��: G~ :,',
Street Address: Mailing Address:
�`q.t�ESHp4'� 2750 Kelley Parkway P,O. Box 66
`' � Orono, MN 55356 Crystal Bay, MN 55323•0066
To: The Current Owner of Address �� �-I � ll�c�/�h /�/'/-t�--�-� �
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No '�
If yes, please contact the Onsite Systems ManaDer at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes
No �
If yes, system must be brought into compliance by:
December 31,2007
December 31,2010
Other �
Septic Tanl�s) Pump out Needed
Yes i�
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
�- f D - c� � . The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleaning.
Comments:
�.� � � -d �
Inspector: Date of Inspection
Telephone(952)249-4600 • FaY(9�2)249-4616
w���w.ci.orono.mn.us
. � °� ..
o��., o � . .
� ���°�� CITY of �]EZO
*�, �,���,,��, ,, NO
7,� :�;,,�'��,,���� G'y�' � .. Municipal offces
���"'�'�"�t"�'�`�� G` Street Address: . Matling Address:
.1'�?�r 1/O y .
. ES�I g �2150 Keiley Parkway � P.O. Box 66
Orono, MN 55356 Crysta( Bay, MN 55323-0066
Owner: IJqv�,d S"�a a�ce.11 � � 34� /�. Arn.
Address:_ �n. .
Ciry Ordinance 199 requires that each existing on-site sewaoe�ea�ent system in Orono be inspected every rivo yeazs.
The on-site seivage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): ( � � �
lO "CODE SYSTEM" Aa ISTS whieh meets aii the lacatioq daiga aad cocutruction staadscdi of the cuaent prono bfuaicapai Cade.
2 "COVIPLIANT SYSTEM" Aa ISTS whieh does aot meet a11 the loeatioq daign and eoastcuetioa standards ofthe eurreat prone 1Vfuairipal
Code bnt doa meet the three foot sepacation nquiremen�aad wf�ich is not fa�ing ac aa im�niae�thteat to publie healtFi or sa:_ty.
3 'NON-CO�LIANT SYSTEM" Apcohibited ISTS;ae LSTS louted withia a daigaated 100 year fload Plaia�any ISTS wSuch may
or may aat auet all the Iocatioq daign,or conttruction staadatds of the eurreat Oroao bfaaicipal Code aad whieti is failing far aay reasoq aad
any ISTS with las than three feet of u�ahuaied soil or saad betwera the distnbutioa deviee aad the limiting�oil characteristia.
TANK CONDITION f5-10): �. � � " •- �
Tank inspection indicates: .• • �
OPumpout nat neaded at this tiate.
6 Tacik must be pumped out this yeat (city code requica Lankt to be pumped out every 3 years. Tank was lazt pumped �,
7 Salids aavmalstion in tsaks is at a critieal a criti�I leveL Tmlcs should be pumped out as saon ac possible.
8 System is discharging to the sucface. Tanics must be pumped out within 48 hours to elimiaste sucface d'uchsrge.
9 Inspa'tion risers missing-tanks eould not be inspeeted Inspectian risers(4"dib pipe)must be insta!!ad in each tacdc at nest pumpout If tanks ,
have nut br.n pamped out within the latt three years,tl��y�ould ba pumped out now.
10 Inspertiun pipe u lxued d"irectly over tank ba@le(does nat give aceurate measuremeat of solidt aecumulation). If tanks have aet beeapumped
out�vithin the last three yescs,tltey shoutd be pucnped out no�v.
DRAINFIELD CONDITTON(11-14): _,�
�'Drsinfield u dry,no surfuiag evident •
12 Some erldence of surfaeing,not eridca!yet � � . ' ' . • .
13 Drsinfield is sstunted and visbIy discharging nntre�ed e�luent W tha surface. Cantad the Ciry Inspecto�imrsiediacely.Repairs must be
eampkted«ithin 90 days. .
1� DrainFieId estent and eondition uaknown.
co�rrrs: S�s��, E o oks p k �
�6-�� - o � G�� � _
Date oflaspecaoa Sepfic SystemIns ector * • '
P "
Note: Ia tlu eveat that this mspecsian repad is used W satiify the requireme�for a mart3age or otha 4ansfa of property,be advised tbat thit tepaR daes aat guaranta
or eertiFy that aa e�a.sting sysum will eaatiaue to Functlaa properiY,but'u maely m apinion of the adequsry of the system uadec eua�t oo�tiom baud aa the avalIsbla
infoca�atioa