Loading...
HomeMy WebLinkAbout2000-P02850 - mechanical PERMIT CI�Y �F ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: Po2sso Crystal Bay, Minnesota 55323 P@f7111t Type: Mechanical Permits (612) 249-4600 Date Issued: gi2iioo SITE ADDRESS: 1461 North Arm Dr MOiJND,MN 55364 PID: 07-117-23-44-0070 DESCRIPTION: ' Proposed Use: Other Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 110.14 Valuation: $ 8,81 t.00 State Surcharge Fee: $ 4.41 Misc. Fee: $ 1.50 MAIL IN TOTAL FEE: $ 116.05 APPLICANT: DITTER INC&D[TTER PROPERTIES OWNER: D&J KOCH 820 TOWER DR 1461 NORTH ARM DR HAMEL,MN 55340 MOLJND MN 55364 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. �����- �, "� �� � � � ,_..:c `..t__ c �;!'?��_/7 APPLI ANT PERMiTEE SIGNATURE SS EDBY SIGNATURE ��/ % J Copies: City,Applicant,Assessor, Finance Page 1 . �JU Z�r�u CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 ;�. , - GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical DesiQns - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: New Addition Repair �Replace Reside tial Commercial JOB SITE: � � �`;v.e Zip: ��3� — Owner's Name: {J o Telephone Number: ` - Mailing Address: n-� " , ��r2 City: � ��_ Zip: 5'-`S Contractor's Name: `: � Tele hone Number: < - Mailing Address: .4{ r City: ��r Zip: SYSTE�1 DESCRIPTION ��`m'����� ,�r;� � HEATING SYSTEMS ? � �p/�� Quantity: �'` � �� � -�,. �b' Make: ' Qi � Model: Fuel: Flue Size: Input BTUs: /DO,�Uo Output BTUs: �,c��> CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H. Power ; - . . .,.. - � . . . , .. _�,.;�� 1 . � . � . . . ,. . .. _ . � .. . .. . . �. , a. . � � - . . � . � � . . �. � . . S ... . " . '.�:s: . �'�-, FIREPLACES - Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. �;. � VENTILATION ;'` . ':f No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Lacati�ns cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside � LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) J � ��-{ �-.r�c�; i ;, �v=x .0125 $ i � (contract price) � 2. State Surchar�e. ** Add the State Bui�ing Code;Division `��- Surchargc to �ach permit. i�,�J � x .0005 $ or $.50, whichever is greater (contract price) 3. Posta�e and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ _�� (� ,� * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materiais, iabor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may j � request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota � State Building Code, and cer.tifies,that all statements made on this application are complete, true and correct. � � i / ' Applicant's Signature: , '�� �l� Date: � ��� 00 / ��--�i Approved By: ��, Date: r r , KOCH HVAC LOAD ANALYSIS for ' DON KOCH 1461 N ARM DR. ORONO, MN I' � ���� ��jA�`�'T�A� � ���. �Q�� Prepared By: Doug Bjork Ditter Inc.,Cooling and Heating 820 Tower Drive Medina,MN.55340 (612)478-9558 8-14-00 RPNAC-Residential8�Light Commerclai HVAC Loads Program EIIte Software Development,Inc. Ditter,lnc. KOCN Hamel,MN 55340.9691 &1a-00 pgge Z Total Building Summary�oads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 220 11,152 0 11,312 11,312 10F Door Wood Solid Core& Metal Storm 63 1,854 0 477 477 12C Wall R-11 + 1/2"Gypsum(R-0.5) 1,621 13,422 0 3,443 3,443 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 896 6,594 0 1,690 1,690 16G Ceiling R-30 Insulation 768 2,332 0 1,115 1,115 21A Basemt Floor 2'or More Below Grade 768 1,696 0 0 0 Subtotals for structure: 4,336 37,050 0 18,037 18,037 Active People: 6 0 1,380 1,800 3,180 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 245.8, Summer CFM: 92.2 283 24,131 2,188 1,967 4,155 Ventilation: Winter CFM: 25.0, Summer CFM: 0.0 0 2,455 0 0 0 Sensible Gain Total: 23,004 Temperature Swing Multiplier: X1.00 Building Load Totals: 63,636 3,568 23,004 26,572 Check Figures Total Building Supply CFM: 1078 CFM per square foot: 1.403 Square feet of room area: 768 Square feet per ton: 300.469 Building Loads Total heating required with outside air: 63,636 Btuh 63.636 MBH Total sensible gain: 23,004 Btuh 87 % Total latent gain: 3,568 Btuh 13 % Total cooling required with outside air: 26,572 Btuh 2.214 Tons(based on sensible+ latent) 2.556 Tons(based on 75%sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Friday,August 18,2000 DATE TIME CITY OF ORONO CALLED IN ' INSPECTION NO ICE SCHEDULED '� -=O D /{'r PERMIT N0. D COMPLETED �X � ADDRESS ` � f��C T/-( .4-�P.�.r � OWNER �ON I�G C{'� CONTR. /��Ti�?"� TELEPHONE NO. �s� y�a .�,3� / � DESCRIPTION !`7 ' � -S �/�i(�1�'� � 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING MECHAN L FIN 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD• 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARO COVEF REMOVAL J 10 PLUMBING FINAL 36 FOUNDATIOWREMOVAL � OWNERICONTRACTOR TO MEET YOU:_YES_NO � COMMENTS: � W a j O � � O � W � Q � Z W � W � � � ORKSATISFACTORY:PROCEED �ROJECTCOMPLEfE W �CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN p CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlConU ctor on site: inspector. � �� White Copyllnspector's File Canary CopylSNe Notice