HomeMy WebLinkAbout2002-P04870 - mechanical � PERMIT
C�ITY OF ORONO permit Number:
2750 Kelley Parkway- PO Box 66 P04870
Crystal Bay, Minnesota 55323 Permit Type: Mecnanicai Pennits
(952) 249-4600 Date Issued: 2iai2oo2
SITE ADDRESS: 1285 North Arm Dr
Mound,MN 55364
P I D: 07-117-23-41-0015
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 3�•24 Valuation: $ 2,979.00
State Surcharge Fee: $ 1.49
Misc.Fee: $ 1.50
TOTAL FEE: $ 40.23
APPLICANT: Ditter Inc.&Ditter Properties OWNER: Keenan&Jean Richardson
820 Tower Drive 1285 North Arm Dr
Medina,MN 55340 Mound,MN 55364
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
--�° ��;z��
�
PPLIC T PERMITEE SIGNATURE IS DB SIGNATURE
Couies: 1-File(SiQnitures Reauired). 1-Anolicant 1-Monthlv Reports, 1-Assessine, 1-Finance Page 1
�
��/, �,�7 '._i
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
rk!
GENER�IL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be ''�
reviewed and a permit will be issued within 2 working days. �
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical Desi�ns - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements.
6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. -�
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. �
Please check one: New Addition Repair �Replace ,�
Residential Commercial
JOB SITE: Z�� 't� ��'h , �i Zip: 5 S�1,� :'�
Owner's Name: � i sc Telephone Number: �5�' -(�G1,7- � 7 �
r�
Mailing Address: I Z< � � . �� City:(��i C�'��� � Zip: ,�� .� '
�
Contractor's Name: � . Telephone Number: �(;��(�y5�--C�,��� `
Mailing Address: ' � � City: .�� Zip: j.�3y�:�
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make: t1iC�i 1 ML�i�n-
Model: G C� '�}}1��1
Fuel:
Flue Size:
Input BTUs: (Q��L���; '�
Output BTUs: � ;�
CFM:
COOLING SYSTEMS �
Quantity: ��
Make:
Model�
Tons:
H. Power
FIREPLACES `��
,,::,
Gas factory fireplace �
Wood burning factory fireplace with flue ;;:�
Wood Stove
,};
Wood stove with flue .�
Brand Name Model No.
VENTILATION ��
No. Kitchen E�aust ducted recirculating cfm ��
No. Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal �'
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening =
,.
3�
PERMIT FEE CALCULATION �
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
Z��C � X .ol2s � 3� .� z '
(contract price) �
2. State Surchar�e. ** Add the State Building Code Division �
Surcharge to each permit. �C;Z�'� aL x .0005 $ � � �� �
or $.50, whichever is greater (concracc price) F,�=�
rna�
3. Postage and Handling (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $ �-(�f ���
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer :�i
for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or :s
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may `�
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all �
work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements made on this application are complete, true
and correct. -
A licant's Si nature: /�. • ����� � -
pp g , � Date.
�
Approved By: Date:
s �
RICHARDSON
HVAC LOAD ANALYSIS
for
JEAN RICHARDSON
1285 N ARM DR �
ORONO, MN I
�
�
� '
�
� � + �� ��jA�1��A�
� ����Q��
�
Prepared By:
Doug Bjork
Ditter Inc.,Cooling and Heating
820 Tower Drive
Medina,MN.55340
(612)478-9558
10-12-2001
�v
- �I��RHVAC=Residential&Ltght Commercial HVAC Loads Program � Elite Software Development,Inc. �
'�itter,inc. RICHARDSON
i Hamel,MN 55340-9691 10-12-2001 Page 2 i
i -- -----------------__--_ _--_
- - - --- - --
____ __-._ __ __ __ .. _
System#1 Summary Loads
' -- - ',
--- -- -------- _. -- ___ _-- - -- -
� Component Area Sen. Lat. Sen. Total ',
Description Quan Loss Gain Gain Gain
- ---------- - ---------- --- '
� 3A Window Double Pane Clear Glass Wood Frame 220 11,152 0 11,312 11,312 '
10F Door Wood Solid Core& Metal Storm 63 1,854 0 477 477 ;
12C Wall R-11 + 1/2"Gypsum(R-0.5) 1,621 13,422 0 3,443 3,443 �
12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 896 6,594 0 1,690 1,690
16G Ceiling R-30 Insulation 768 2,332 0 1,115 1,115
21A Basemt Floor 2'or More Below Grade 768 1,696 0 0 0 !,
Subtotals for structure: 4,336 37,050 0 18,037 18,037 �
i Active People: 6 0 1,380 1,800 3,180 ;
Inactive People: 0 0 0 0 0 �
Appliances: 0 0 0 1,200 1,200 �
Lighting: 0 0 0 ��
Ductwork: 0 0 0 0 0 I
Infiltration: Winter CFM: 184.3, Summer CFM: 92.2 283 18,098 2,188 1,967 4,155 '
Ventilation: Winter CFM: 25.0, Summer CFM: 25.0 0 2,455 594 534 1,127 ��
--- ---- ----------------- --- ;
Sensible Gain Total: 23,538 ;
Temperature Swing Multiplier: X1.00
-- --- - -- - �
- - ------ -
i System Load Totals: 57,603 4,162 23,538 27,699 '
I -- ------------- --_ ----___ - _ _ __ _ -- _
Check Figures I
- - -------
Supply CFM: 1,078 CFM per square foot: 1.403 �i
Square feet of room area: 768 Square feet per ton: 293.657 ,
i
System Loads - - ------ ------ --- --
Total heating required with outside air: 57,603 Btuh 57.603 MBH
Total sensible gain: 23,538 Btuh 85 % i
Total latent gain: 4,162 Btuh 15 % I
Total cooling required with outside air. 27,699 Btuh 2.308 Tons (based on sensible+ latent) �i
2.615 Tons(based on 75% sensible capacity) '
I Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary. ,
Be sure to select a unit that meets both sensible and latent loads.
�� i
,
i I
i !
� I
I
i '�
� ,
i �
�- - -- - �
Thursday,January 31,2002