City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two.years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
STEM CONFORMITY (1-3): �
` 1 '"CODE SYSTEM" An ISTS which meeu all the location,design and construction standards of the cunent Orono Municipal Code.
2 J"COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS locatod within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of tho current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-71:
�k inspection indicates:
Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ). ;
Make sure seatic tanks are aumaed throush manhole and not throuth white insaection oipes. This allows for the aroaer
cleanin¢ Keea water softner and iron f lter discharee out of seatic svstem to prolong life of drainfield. Ask aumper to test
alarm float to verifv alarm is still working in vour house The alarm warns owner that seataQe is about to backua into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If �
tanks have not been pumped out within the last three years,they should be pumped out now.
D IELD CONDITION(8-101: �,
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
<. �. . _ - . .
. COlWIMENTS: ,�r":d,�„� ,��; � : .�" .�K; ,,5`C�.�'':��: "�a'"`,�
laa � - 0 .
. :.. .,�;s.�.�,.�k . � `
�
� �t� ��, � � ��
� ,� ' "��r � � ��� �� .
� �i�:-� .�. � � �: ,
Da�e of�nsp�tio� i� �: � Matt Bolterman - Septic System Inspector
� � � � � �'' �
i:� ..� R�..:. � �� ! :s�"# � :. .. .; �. . :: . .:.
Na�: ln the even�"ihat� is �5pe_ on� po; �s ' 'd t sati : tl req�rentb`�ts-ftlr a ittortgage ar other trat►sfer 4f property,be�dvis2d that"t{tis teport cVoes'
:«of gua[�wteG�r � if �tha� n sti �sy' m iU nti' t unC�n p�'oper#p but �s cnerely an opimnn of the �deqktacy af tlse system eEnder currcnl
` � � G`�tti�b�� � :'��.. ,�� yr.�r° :���; �" � �
�f,,.� �. te si de i� 'o � . � � ��. M a � , � . ` p. .. � „
. . . . . , .�.�n i.a�', ..;x,��:� �. . . -�,� ,ns ..�li,s�... n�G�: ,.
� o�
.� oo.:�,, .
��=�T-� CITY of ORONO
� ��`�?��.2-
��� � :,r'.:�
"� '1' �: �`°~ � 1�1unlci
� 4i�j-�. �°+,�y 'ti P� OfTces
l ����;������gf�iG ' Street Addreu: Mailing Address;
,,.ii
E880 2750 Ke11ey Parkway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
. 95d-�4q-y600
To Current Owner: Address: 5Ov 11/0�� ,L���,r, �f_
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
The on-site sewa�e treatrnent system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY 1-3 : f .
1 "CODE SYSTEM"M ISTS which meets all the location,duign and conswction standards of the current Orono Municipal Code.
2 "CO\�LIANT SYSTEM" An ISTS which dou nat meet al!the location�daign and construction standards of the cumnt Orono Municipa]
Code but does meet the three foot separation requinment or two foot rcquirement for systems installed 1996 or earlier.and which is not faiiing or
-an imminent threat W publie health or safery.
3 "NON-COMPLIANT SYSTEM" A prohibited iSTS;an ISTS located within a duignated 100-yeaz flood plain,any ISTS which may
or may not meet all the location,daign,or conswcdon standards of tJu currc�t Orono Municipal Code snd whIch is failing for any reason;and
any ISTS with less than ttuee feet of unsamrated so1 or sand between the distribudon device and the limiting soil eharacuristiu.
TANK COVDITION(5:71: 6 .
Tank inspection indicates: � . .
5 Pumpout not needed at this time.
6O Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 yeazs.
Tank was last pumpad ), �
blake sure septic tanks are oumaed throuah manhole and not through�vhite insoection oipes
This alloKs for the oroner cteaning.
7 Inspection risers missing tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
RAINFIELD CONDITION(8-1Q�: �
8 Dninfield is dry,no surfacing evident.
9 Some evidence of surfacin�,not critical yet. �
10 Drainfield'u satunted and visibly dischargina untreated effluent to the surface. Contact the Ciry Inspector
immediately.Repain must be completed within 90 days.
eo1�1�NTs: Me��� Ivc��s o(C - �e��.� seF�.� }��lcs ne�-�'
S J�r�cr .
�-� -�� " �' `�C �
Date of Inspection Matt Boiterman- Septic System Inspector
Nate:In the event that this inspecdon report is used W satisfy the rcquirements for a mortgage or other transfer of properry�be advised that this rcpoR docs not guarantee
o�certiCy that an existiag system will continue to functton properly.but is merely an opinion ofthe adequary of the sysum under eurrent eondidons bastd on the availabte
information.
,.�o.�,.
:;o 0
;j ,�,��;��:.� ,� CITY of ORONO
���� ��<� ,y` ,�� �p �lC� Municipal OPtices
� ' •�
,
\ ,t �' ', ,<J:,,<'��"�h�'.�G Street Addross: Mailin�Addreu:
'$'�+gg0�' 2150 Kelley Parkway P.O. Box 66
May 30, 2 Orono, MN 55356 Crystal Bay, MN 55323•0066
Mathew&Heidi Hoy
500 North Arm Drive
Mound,Mn 55364
Deaz Mr. &Mrs. Hoy
An inspection of your septic system was conducted on May 22, 2000. A summary of the inspection is
below.
Septic Tank Condition
l. Pumpout needed as the tanks become full
The septic system is non-compliant because it is failing by visibly discharging untreated sewage to the
surface. This is considered to be an imminent public health threat. This discharge could have adverse
effects to the environment including contamination of your well or neighboring wells. City Code
requires that the system be repaired or replaced within 90 days upon the date of this letter. The septic
system must be replaced by September 31,2000. Until the system is repaired or replaced, the septic
tanks must be used as holding tanks and pumped when full so as not to dischazge untreated sewage to
the surface.
Enclosed is a list of state licensed septic contractors who regularly work in Orono. Also enclosed is a
fact sheet explaining how a septic system functions. Finally, an as-built drawing is enclosed showing
the approximate location of the septic system.
Please contact the inspector at the City Offices at 249-4600 as soon as possible to discuss your options
regazding this situation.
Re ectfully
�,� �iL�
�s Pence
On-Site Systems Manager
Enclosure
In the event this inspection report is used to satisfy the requirements for a mortgage or other ttansfer of property,be
advised that this report does no guarantee or certify the eaisting system will contumue to fimcHon properly,but is merely
an opinion of the adequacy of the system under current conditions based on the available mformation
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www ci.orono.mn.us
_ �
�O� .
O O
' � -- CITY of ORONO
� .��: �t��- � �
� 1,',� �� !S' Municipal Otfices
� �� �, ��, ti
,� ���: �`�°a�'.�G Street Address: MailinQ Addross:
`�CEgg04' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
February 25, 2000
Mathew&Heidi Hoy
500 North Arm Drive
Mound,Mn 55364
Dear Mr. & Mrs. Hoy:
� The City of Orono implemented a septic system inspection program in 1978. City staff inspects all properties
in Orono with a septic system once every two to three years. The inspection entails checlang the system for
compliance with State and City codes. The inspection also includes exam;n;ng the septic tanks to deternune if
a pumpout is needed. Finally,the inspector looks for any site limitations that would inhibit the septic system
&om functioning properly. A report is then mailed to the homeowner explaining the condition of the system
and if the septic tanks needed to be pumped. The report also includes information if the system needs repairs
and the time frame for when the repairs need to be completed.
In 1989, Minnesota passed a law that stated all new and existing septic systems must have a three foot vertical
sepazation between the bottom of the drainfield and the seasonal watertable. This then forced City staff to
conduct soil borings along with the other aspects of the inspection stated above. City Council then passed a
resolution that those properties located with in the shoreland district would need to replace a non-compliant
septic system within seven years. Those properties not within the shoreland district must replace a non-
compliant septic system within ten yeazs.
The septic system at the above described property has been deemed non-compliant by the City of Orono
because it does not meet the three foot vertical sepazation requirement in the drainfield. The septic system
must be replaced by December 31,2000.
If you disagree with the inspection results,there is an appeals process. Enclosed is a list of State licensed
� septic contractors and inspectors who work regulazly in Orono. You may contact an inspector on this list to
independently inspect your septic system for compliance with State and City codes. If the septic system is
found to be compliant and is issued a certificate of compliance,the system will not need to be replaced. If the
system is issued a notice of non-compliance,the septic system will need to be replaced by December 31,
2000. ff tlus is the avenue you wish to pursue,please contact an inspector as soon as possible to set up a time
for the inspection. City staff will not be on-site when the independent inspector conducts the inspection.
� If there are any questions regazding this letter,feel free to contact me at the City Offices at 249-4600.
R ctfull ,
� , I /
�W
Chris Pence
On-Site Systems Manager
Enclosure
Telephone(612)249-4600 • Fax(612)249-4616
•�\` ��
� � 14�'`'`
,�.
O o�,,
���.:,,,;:::-.� ���.`�.' o� �1�.�1��
�%,��;::,,�',:7�,.
r� ���� =���;�,,� y� �, Municipal Offices
���� '� 1 c� 'hr`_� (�'�', �'
\:..'� �'��}"{;;.��:,`�'":;``��� � � Street Address: Mailing Address:
�:r .t�;,.
�''��`�,�<q,k''`'�'�"'p4��i;'� 2150 Kelley Parkway P.O. Box 66
`.:; E$I3 ��� Crystal Ba MN 55323-0066
� Orono, MN 55356 y�
To: The Current Owner of Address ��,f; �'"�✓� �� ��`�''' -
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The.onsite sewa?e treatment system at the above
address has been inspected and the following is l:nown about the system. A
sketch of tlle lcnown components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No �
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of tYus notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as N -Compliant
Yes
N�
If yes, system must be brought into compliance by:
December 31, 2007 �
December 31, 2010
Other
Septic Tank ump out Needed
Xes
No
The City recommends the septic tank(s) and/or lift tai�k be serviced and pumped
out every three years, City records indicate the tank(s) were last pumped out on
�� _ ��; . The tank(s) should be cleaned throuQh the manhole and
not through the inspection pipes,tlus allows for proper cleaninQ.
Comments:
�
Inspector: ,���= Date of Inspection (.�� �� �
Telephone (9�2) 2�9-460Q ^ Fa� (9�'_i 249-4616
���
O '�A O
�� � CITY of ORONO
,,��"` =�
� �� j�,�` .'�;� I,'►
r�, � ��` "y�` �' 15r Municipal Offices
� F��:i�,.% � ti
�,� ��`���_��'�!�=pr�,�'��',�G SVeet Address: Malling Address:
� ��.��.�r-��,. ,� .
$EgKO 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: ��'�'f'{�F� �. �-�-� Address: 500 North Arm Dr.
Permit #'s: 953, 266 Dates: 5/9/60, 4/23/63 Contractors: Hopkins P1bQ., E. J. Peterson
Co.
(This is [1/j an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
/� codes and is functioning properly.
( 3 1 Non-Compliant System: System may or may not meet current City standards for design,
�'J construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and tlze saturated soil level.
(The saturated soil level [� has or [ ] has not been identified at this time. If the
saturatad soil level has aot been identi£ied, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
� Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or [, ] were not confirmed
to be watertight by the licensed pumping coatractor. If the tanks were not confirmed to be
watartight, this classification is subject to revision.)
DRAINFIELD CONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : hiqh
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is .3 feet and the system is non-compliant. Repair or replacement of
the septic system is required by 9/31/97.
4��3b �9 7
Date of Inspection Se i System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 a � ON—SITE SEWA(�E TREATI�NT
v$,, �, INSPECTION REPORT
'�t' Gti
�9kEsxo4`'�
Owner: Address: ��� il/i ftf�h'\ !A.
i r
Permit �'s: � ' Q Dates: S�t��Contractors: ��y . /F,T�
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is [�. an existing system [ ] neu construction>
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system Which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
"NON-CONFORMING SYSTEM'�-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
� Codes and which is failing for any reason; and an s stem with less than 3 feet of unsaturated soil or s
between the distribution device and the limi ing soi c ' . �
��� y ia 3��s
(The limiting soil characteristic has or [ ] has not been identified a this time. If the limiting soil
characteristic has not been identi ied, this classi#ication may be subject to revision.) �
TANK CONDITION (5-70):
Tank inspection indicates:
5 Punpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accurtwlation in tanks is at a critical level. Tanks should be punped out as soon as possible.
8 System is discharging to the surface. 7anks must be pumped out uithin 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pimiped out within the last three years, they should be punped
out now.
� Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been punped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-74):
D�nfield inspection indicates: 9 �Q� �'�'y�('q'+`�
7 Drainfield is dry, no surfacin evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE Cdepends on soils,water table.etc.):
COMMENTS:
� � ��
� � �
d�"
Date of Inspection Sep ic System Inspector 'g'�3l'9+S
Note: In the event that this inspection report is used to satisfy the require�nts for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER ADDRESS �✓�L� � •
e �r .'�'I 1-��To23-�
PERMIT NO.'S. DATES 3 CONTRACTORS i 1`e�
City Ordinance No. 210 requi►es that each on-site sewege t�eatment system in Orono be inspected on a regular basis.The onsite sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is � an existing system ❑ new construction)
� � Meets o�exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
loceted, and constructed generally in sccordance with previous codes.System appears to be functioning properly;no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of potlution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is�ecessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
4 Tan inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not
� � Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tsnks indicates they should be pump- have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Soli� accumulation in tanks is at a critical level. Tanks Drai field inspection indicetes:
should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident.
❑ System is discharging to :urface. Tanks must be pumped O Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Orainfield is saturated and visibly discharging untreated
❑ Inspection risers missi�g—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4"dia.pipe)must be instslled in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they shoutd be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiti�g Site Factors Potential for System Failure Site Capabilities for
O Slope (depends on soil types,water Future Expansion
❑ Soil table,and systern condition) �Adequate
O High water table ❑ Low ❑ Fair
❑ Lot size �Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge. �
/
COMMENTS: � -� � '� PJ L�'I'1 S P
v / . / �
� „�
Date of Inspection S tic Syste Inspector
Note: I� the event that this inspection report is used to satisfy the requirements for a mortga�or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current co�ditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner