AGREEMENT TO UPGRADE/REPLACE
ON-SITE SEPTIC SYSTEM
I/We,_Jessica Brown/Phil Lusardi do hereby acknowledge
Name of Owner
that the on-site�septic system located at_45 Myrtlewood Road
Property Address
must be upgraded or replaced to be in full compliance with Section 12.30, Individual
Sewage Treatment System Standards for the City of Orono. UWe have submitted or will
submit soil borings, perc tests and detailed design.
And further, Uwe agree that such upgrading or replacement will be completed no later
than 12 months from the date of the assigned agreement, except that in the event that at
the end of the 12 months the City has not decided whether the Myrtlewood Sewer will be
constituted or that it will not be,then the septic replacement deadline can be extended
til the process is complete.
! _ � � ,31� � � .
er Date Owner Date
�
�l� o�
Wi e , City of Orono Employee Date Signed
Failure to upgrade or replace the septic system as agreed to above will result in
enforcement action as prescribed in Section 12.30 Individual Sewage Treatment System
Standards for the City of Orono.
W:\(Forms)�.Septic System Agreements�2,008�,AGREEMENT TO UPGRADE-45 Myrtlewood.doc
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
SEPTIC SYSTEM INVENTORY
Site Address: 45 Myrtlewood Rd 1'�D: 3611823330015
Owner Name: Jessica M. Brown
Owner Address: 45 Myrtlewood Rd Wayzata MN 55391
Building Type: residence Installer:
Date of Permit: 10/24/85 Earl Day Pibg
System Type: mound BRs Designed for: 4
In Musa?: No Shoreland?: �
SEPTIC COMPLIANCE INSPECTION t7� /�
Report Date: \� \ �,
Compliant?: �- � Expires: � � �
Non-Compliant?: Report in Street File? `��
T
SEPTIC TANKS _�
Materiat: precast concrete Capacity: �800, 00,1000 Tank Filter: �
DRAINFIELD �„�
Treatment Area: Soil Boring: yes DF Ht above Wt: �!
WELL DATA
Setbacks-Well-Tanks: 50 Well-DF: 75 Report in File?: � Depth: �
INSPECTION RECORD PUMPOUT RECORD
Date Description Date Gallons
11/7/85 installation 09/19/89 500
6/25/87 no surfacing 08/22/96 1000
7/6/90 no surFacing 07/06/98 800
10/22/92 no surFacing 04/21/99 800
8/2/95 no surfacing 07/21/00 500
10/26/98 DF damaged,alarm off 11/25/00 1000
7/19/00 no surfacing 10/13/01 1000
6/27/02 no surfacing,pump tanks 07/02/02 800
08/31/04 OK-Non-conforming 10/18/04 1800
, . .
i i�
� �
�/r ,��� �, � , .
� , ,
.
�
- -- � � ,
� � �
� � � ` �
\ � �
� � \ �_
� �
�
\
` � ' �
,
� � � 3 � a /
'T r — Z•`�` f I�(o" � • \
'7'Z r-y'�;' 3�` -
��3 ��5� `33� -.
-___ _ - ------�------------------------ --- - - / � -
� O� _
O : O
���� �-�- CITY of ORONO
;,..-
� � ,-_
a �.���:��� _ �
,�, � n: �:, . �ti M�;��� otr,��
\ �1 t,'�� �.Lr ��
\�� ��,��`�. �;, ,�G Street Address: qsa-�49-y6o O Malling Addross:
9$EgHO�' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: J� ��f r�")�-�DDv ��
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
The on-site sewage treahnent system at the above address has been inspected and appeazs to fall into the categories checked below.
S� S"TEM CONFORMITY 1-3 : I
1 `CODE SYSTEM"?,n�ISTS which meets all the loca6on,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An IST'S which does not meet all the location,design and consiruction standards of the current Orono
Municipal Code but dces meet the three foot separation requirement or two foot requir�ent for systems installed 1996 or earlier,and
which is not ffiiling or an ia�►inent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and wlrich is failing for any
reason;and any ISTS with less than three feet of unsadirated soil or sand between the distribution device and ttie limiting soil characteristics.
TANK CONDITTON(5-71: S
Tank inspection indicates:
5�1'umpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped �0-1`6'U`f ).
Make sure seatic tanks are aumced throueh man6ole and not through white iasaection uiaes. This allows for the proner
cleaninQ. Keeu water softner and iron filter discharee out of seatic svstem to arolone 6fe of drainfield. Ask oumner to test
alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner t6at se�ta¢e is about to backuu into basement.
7 Inspection risers missing-tanks could not be inspected. Insp�tion risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
IELD CONDI'TION 8-10 : �
8 Drainfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
10 Drainfield.is saturated and visibly discharging�r►treated ef�luent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMN�NTS: _ M t•• �, �" ScQ�;L �-��lf,� �oh� b� .
�-��—o� G1�
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or otha transfer of property,be advised that this report dces
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available information.
�°� �
o : o
��=������? CITY of ORONO
��� -�. .�
a���. �:�.
� �:• . •,
,� ��,�, .�"
v�, ��� �y��;,; � 15► Municipal Offices
`. °� ��,� '�
� i;';�.,:��.i:,_,.h G
� , � �{'��.� ,� Street Address: Mailin�Addreu:
'�',E g g04 2150 Keiley Pa�kway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
9sa-�49-4boo
To Current Owner:
Address: �s !'-��2 wd�C� ��/
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-31: �
Ol "CODE SYSTEM"M ISTS which meeu all the location,design and conswction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standazds of the cuaent Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibiud ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet atl the location,design,or conswction standards of the current Orono Municipal Code and which is failing for any.reaSon;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-10): 6
Tank inspection indicates:
5 Pumpout not needed at this time.
6OSeptic tanks must be pumped out this year (city code r;quires tanks to be pumped out once every 3 yeazs.
Tank was last pumped Setc.�c� }h�.K �zw� P�:''�p�cC
Make sure seatic tanks are pumued through manhole and not through white insaection uipes.
This allows for the aroaer cleanin¢.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
D INFIELD CONDITION 11-14 : �'
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: s �. lo�� O . Net� v -o�= �.. Z��� S; �;� i��.
\��� �:�5�. Se ?;L �-c.nK ea�ter — C��� Nt Q:.Ser Q� a�1 �^ e�re•�
�c� 5 Ldn �+�� -
6 - �7—0�. ��c �'�.
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requiremenu for a mortgage or other transfer of property,be advised that this report does not guarantee
or ceRify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
�O�
, O O
�� �A1 � - CITYof ORONO
��.I 3�rs..� ..
�1`` ��'��`��`�~ � � M��� �C�
,\� � ^•` ' q -
��`�,� 4 ,��:' ' ; G'ti,
�,�� -t `_�-;A�,�
Street Addrou: M�IIInQ Addross:
�$+gg04' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
July 24, 2000
Anita Liebscher
45 Myrtlewood Road
Wayzata, Mn 55391 _
Dear Ms. Liebscher:
An inspection of your septic system was conducted on July19, 2000. A summary of the inspection
is be�ow.
Septic Tank Condition
1. Pumpout needed within one year.
The septic system is a compliant system, meaning it meets all or most cunent City and State
Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This
list is enclosed simply for your reference in case your septic system needs maintenance in the future.
Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built
drawing is enclosed showing the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
Respect ly, -
�
Chris Pence
On-Site Systems Manajer
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,
be ad�•ised that this report does no guarantee or certify the ezisting system will continue to function properly,but
is merel�an opinion of the adequacy of the system under cnrrent conditions based on the available information.
This report must be kept on the premises with the s�stem location and pumping records.
Telephone(952)249-4600 • Faa(952)249-4616
www.ci.ornno.mn.us
� , ��
��
,;O O
� .�� ,_ - � CITY of ORONO
,', � , .,r � ��
�� � �y ��%, �!4 Municipal Offices
�,� '�� ��G Street Address: Mailing Address:
���Egg04' 2150 Kelley Parkway P,O. Box�66 �
Orono, MN 55356 Crystal Bay, MN 55323-0066
�
Owner: /7 � T LL !�-1 '�.�KJ��I� r Address: 45 Myrtlewood Rd.
Permit #'s: 8145 Dates: 10/24/85 Contractors: Earl Day Plbg.
(This is (�] an existing system [ ) new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [X ] or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
�K CONDITION (5-9) : 5
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
D AINFIELD CONDITION (11-14) : 11
1_ 1J Drainfield is dry, no surfacing evident.
�I� Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
CO[�1ENTS•
Alarm disconnected for remodel, portion of mound excavated-sand to surface damage to
system unknown.
� i
�(� � � �" `� �� �_–�� � �' �— _
D`ate of Inspection ep c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 � FAX 473-0510
CITY OF ORONO " O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(;E TREAT�Ml'
r�`, � INSPECTION REPORT
'�� G~
�kESH��'�
Owner• ddress:
Permit �'s: Dates: ontractors: �/ '1'llx!•/�l�) 'ML�A.
City ordinance nuni�er 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �an existing system [ ] new construction)
S1'STEM CONFORMITY 1-3 :
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which mey or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any_system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil charecteristic W has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi'#i�d, this classification may be subject to revision.)
TANK CONDITION (5-10): �
inspection indicates: ,.,,,.���c s)I1c:.C, � Iv '�
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. 'fanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next puipout. If tanks have not been p�xnped out within the last three years, they should be punped
out now.
10 lnspection pipe is located directly over tank beffle (does not give accurate measurement of solids accunulation).
lf tanks have not been punped out within the last three years, they should be pumped out now.
DRAINFIELD COtdDITION (11-74):
DrfflpQfield inspection indicates:
D v�Drainfie[d is dry, no surfacing evident.
T2 Same evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repeirs must be completed within 90 days.
14 Drainfield extent and condition �known.
LIMITING S1TE FACTORS (slooe.setbacks.etc.):
POTENTIAL FOR SYSTEM FA[LURE (deaends on soils,water table,etc.):
COMMENTS:
Date of inspection Sept' Syste Inspector
Note: tn the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informat�on.
This report must be kept on the premises with the system loc�tion and pumping records.
WHITE COPYllnspectors File YELLOW COPY/Homeowner
CITY OF ORONO �O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON-SITE SEWAQ�E TREATbIENT
� ti INSPECTION REPORT
ti
��9k'EsB��'�G
Owner: IS�/�/r►�er��� BN�"._lX`� Address: �/�/1n�/�] IC�,
Permit �'s: � Dates: k�9-7/�O�-a�f�5 Contractors: � ��_�� �r.
City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is f� an existing system [ ] new construction>
SYSTEM CONFORMITY (1-3):
7 �'CODE SYSTEM'�-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and uhich
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic �1 has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): �
T� inspection indicates:
5 Pumpout not needed at this time.
Solids accixnulation in tanks indicates they should be punped out this year to help prevent future problems.
7 5olids accumulation in tanks is at a critical tevel. Tanks should be punped out as soon as possible.
8 System is discharging to the surface. 7anks must be pumped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each
tank at next Fxmpout. If tanks have not been pumped out within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been punped out within the last three years, they should be punped out now.
DRAINFIELD CONDITION C11-14):
Dr nfield inspection indicates:
I� Drainfield is dry, no surfacing evident.
`R Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
imnediately. Repairs must be completed uithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS Cslope,setbacks,etc.): �"
POTENTIAL FOR SYSTEM FAILURE (deoends on soils,water table,etc J: ���
COMMENTS:
�d��9a
Date of Inspection S tic ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
tnformation.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner