HomeMy WebLinkAboutseptic info � °�
o ; o
��i��:��:- CITY of ORONO
� ������ - � �
,� ` � ��p�� titi M�,;��� ot���
'�' 1 ` .`�.��.°
i�',�, G �15a-a49-'i6o 0
\ � +,'-�f f.,: ,� Street Address: Mailing Addross:
`��Hp'g' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
` ��
To Current Owner: Address: ! � M�f�� �-���/
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at ihe above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (i-3): �
1 "CODE SYSTEM"An ISTS which meets all the location,design and conshuction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS wluch dces not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an i�inent threat to public health or safety.
�"NON-COMPLIANT SYSTEM" A protubited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may bot meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any LSTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): t7
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are aumued through manhole and not throush white insaection uiaes. This sllows for the aroaer
cleanins Keea water softner and iron filter disc6aree out of seatic svstem to arolon¢life of drainfield. Ask uumaer to test
alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner that septa�e is about to backua into basement
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D IELD CONDITION 8-10 : ,�,
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield.is saturated and visibly discharging untreated ei�luent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENT�S. �f�y t��F-_.c�(l 1S rUh- C U� 1'[,�j d-- /`'`v�Y ��
_�(�1��c�-t,1 b,�r \�=31-'2,.01 U , ✓•-� 1 t��i L fiFn1l' d v�..*�-r r 2 a c'3-
°��1-0� G�
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the ev�t that this inspection report is used to satisfy the requ'u�ents for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available int'ormation.
� � � ��
.� o
o..,,
�y�_��� CITY of ORONO
� ' `�'��`,r? .�,+
������.��.� ti
_" G.�, Municipal offices
�4i j'��`�
� ��.='��a=� � �'y ' Street Address:
►•�.►� Mailtn�Addross:
�.ES�I�g 2150 Keiley Padcv+►ay P.O. Box 66
Orona, MN 55356 Crystal Bay, MN 55323-0066
95d-�yq-y600 -
To Current Owner: Address: �5 �'� r t� w d o d d
Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage�eatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-31: �
1 "CODE SYSTEM"An IS'TS which meeu all the location.design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYST'EM" M ISTS which does not meet all the location,design and construcdon standards of the cucrent Orono Municipal
Code but doa meet the three foot separation requirement or two foot nquirement for rystems installed 1996 or eariier.and which is not failing or
�"� an imminent threat to public health or safety. .
( 3 )'T10N-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a duignated 100-year tlood plain,any ISTS which may
�-� or may not meet all the location,design,or conswction standards of t�e current Orono Municipal Code and which is fail'ing for any teason;and
any 1STS with leu than three feet of unsaturated soil or sand between the distribudon device and the limidng soil characteristics.
TAMC CONDITION(5:7�: �
Tank inspection indicates: .
5 Pumpout not needed at this time.
6� Septic tanks must be pumped out this year (ciry code requires tanks to be pumped out once every 3 years.
Tank was last pumped `7'� — qU ).
�iake sure seotic tanks are numoed throu�h manhole and not throu�h white inspection aiDes
This allows for the prooer cleaning.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
D INFIELD CONDITION(S��Q�: �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet. �
10 Dninfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector �
immediately.Repairs must be completed within 90 days.
CO�IYIENTS: D i��,:,•sc-�,c\� '�S n o c�- �o h. 1�.��fi a�-c� rr�st 6c i'e ��c c c�
b ��;3�-�.��0 ���„ r, c� +c 'C-c a� cq:� �;c
�'a.�-o� �a� ���-
Date of Inspection Matt BoIterman- Septic System Inspector
Note: In the event that this inspection report is used w satisfy the rcquirements for a mortgage or other transfer of property.be advised that this npoR does not guaranme
or certify that an erisdng rysum will continue to funcdon properly,but is mecety an opinion of the adequaey of the system undercumnt eonditions based on the available
infortnation.
�
o�
, o 0
�� �� � CITY of ORONo
'+f����� ?y �J
� -� �lCr MunicipalOt'tices
� �i► ' x�,.' �, i
C 'j`i i.
'� �� -,;� `,;:��yG Street Addross: M�ilina Addrou:
'�L+gH04' 2150 Kelley Parkway P.O. Box 66
July 24, 2000 Orono, MN 55356 Crystal Bay, MN 55323•0066
Darrel Heil
15 Myrtlewood Road
Wayzata, Mn 55391
Deaz Ms. Heil:
An inspection of your septic system was conducted on July 19, 2000. A summary of the inspection is
below.
Septic Tank CondiHon
1. Pumpout needed within one year. (last pumpout date 7/25/90)
The septic s5�stem is non-compliant due to a lack of a three foot sepazation distance beriveen the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code, not a City
Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic
system must be replaced by December 31,2010.
Enclosed is a list of state licensed septic contractors who work in Orono on a regulaz basis. Also
enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the approximate location of the septic system.
If you ha�e any questions regarding this report, please contact me at the City Offices at 249-4600.
Respectful .
. �
Chris Pence
On-Site Systems Manager
Enclosures
In the event this inspection repoct is used to satisfy the requirements for a mortgage or ather transfer of property,be
adr•ised that this report does no guarantee or certify the eSisting system will continue to function properly,but is
merely aa opinion of the adequacy of the system under current conditions based on the available informatioa
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
/ ;;=O�
� �\
,, O O �
, �. _.
''� CITY of ORONO
,� ,�. r��- �,
' �, 1' ;;4: �` �..� !S, ;�'I Municipal Offices
\\� , ,... ; ti%
.�� ` f ` ¢.`yG '/ Street Addresr. MailinQ Addross:
���'E+gH� 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: �-��-�c`.��}��-1 �(%( 1 Address: 15 Myrtlewood Rd.
�
Permit #'s: none Dates: Contractors: unknown
(This is [ � an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relatinq to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
�; Non-Compliant System: System may or may not meet current City standards for design,
��•� construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [X] or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 8
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
(8`,� Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
- within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [ ] or are not [ ] water tight or the condition is [�(] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to re�sion.)
DRAINFIELD CONDITION (11-14) : 11
11�= Drainfield is dry, no surfacing evident.
`I2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic
system is required by 12/31/2008. �
�
, �
! ^ - ���, - f=� � t, � -r. � - �-----
`.� �_ i
Date of Inspection Sept System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
� .�O
CITY OF ORONO �
M�icipal Offices O � O
Post Office Box 66 .
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(iE TREATN�NT
� ti INSPECTION REPORT
'�� G~
9kEsxo�'�
Owner• Address•
Permit #'s:�Y�Y1P. Dates: � Contractors: //Yl K�Y1�IwN\
City ordinance number 100 requires that each on-site sewage treatment _system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has .been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
"CONFORMING STSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactority by treating and disposing of the entire current sewage input without discharging
any pollutants into gro�d or surface waters.
3 "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or mey not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or send
between the distribution cJevice and the limiting soil charecteristics.
(The timitin� soil characteristic [ l has or ,[7S.has not been identified at this time. tf the limiting soil
characteristic has not been identified, this cYassification may be subject to revision.>
TANK CONDITION (5-10):
Tank inspection indicates:
� Punpout not needed at this time.
Solids accunulation in tanks indicates the should r to hel r future roblems.
Solids accumulation in tanks is at a cri ice eve an s s ou out as soon as pos
8 System is discharging to the surface. Tanks must be puniped out within 48 hours to eliminate surface�discharye.
9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be instelled in each
tank at next punpout. If tanks have not been pu�ed out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been pu�out within the last three years, they should be punped out now.
DRAINFIELD CONDiTION C11-14):
Dy�f�ifield inspection indicates:
111P Drainfield is dry, no surfacing evident.
�47 Some evidence of surfacing, rwt critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Dreinfield extent and condition unkno►m.
LIMITING SITE FACTORS (sloae,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table,etc.): �
COMMENTS:
Date of Inspection Septi ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an op�m on of the adequacy of the system under current conditions based on the available
informatton.
This report must be kept on the premises with the system locetion and punping records.
WHI7E COPYllnspectors File YELLOW COPY/Homeowner
. , ��1V'
CITY OF ORONO O O
Municipal Offices
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON–SITE SEWA<3E TREATMF�N'!.'
� . � INSPECTION REPORT
ti
���kES�I���G
Owner: L.q►�I�P' ItP.i 1 Address: /J /�/Y{TI/Lt�/� IC�(.
Permit �'s: �'bY►P. Dates: `� Contractors: —
�
City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): � �
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
20 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface Waters.
3 "NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or �E}1. has not been identified at this time. If the limiting soil
characteristic has not been identified, this ctassification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection irxiicates:
5 Punpout not needed at this time.
6 Solids accunulation in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. tanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> must be installed in each
tank at next purnpout. If tanks have not been punped out within the last three years, they should be punped
� � out now.
Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been punped out uithin the last three years, they should be punped out now.
DRAINFIELD CONDITION (17-14):
Drp�.�field inspection indicates: •
LI1/ Drainfield is dry, no surfacing evident.
'r2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE CdeDends on soils,water table.etc.): L'1Nl7�IM'�
COMMENTS:�- 1Xe�� ��►� �.w�e �.�-��.
��
Date o Inspection eptic ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system w�ll continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prernises with the system locstion and pumping records.
WHITE COPY/Inspectors Ffle YELLOW COPY/Homeowner