HomeMy WebLinkAboutRe: septic info %' O
� �
O. :', O
y �� CITY of ORONO
�r �.
,a '��� � ,, < `:� �„
r�`„ w MunicipalOffices
�,.� ,��'�� ,��,�� ,(�., ,tilC�
�� ����'�,���������!i'�`;,'�����'�yG Street Address: MailinQ Address:
��$Egg04' 2750 Kelley Parkway P.O. Box 66
�' - -= Orono, MN 55356 Crystal Bay, MN 55323•0066
February 22, 2000
C. Paul& Rae H. Pesek
1235 Lyman Avenue
Wayzata, Mn 55391
Dear Mr.& Mrs. Pesek:
The above described property is in a Metropolitan Urban Service Area (MUSA) for sanitary
sewer installation. The factors for initiating the sewer project were smaller lot sizes and non-
compliant septic systems with limited replacement sites available. The septic system serving
your home is a compliant system according to State and City standards. Your property was
exempted from connecting to the sanitary sewer system at that time.
The existing septic system serving your home may stay in use until the system becomes non-
compliant. If for any reason the septic system becomes non-compliant, the home must then
connect to the sanitary sewer system If the home undergo's a remodeling project that will
increases the total water use, the home must then connect to the sanitary sewer system.
Minor maintenance can and should still be conducted on your septic system. Pumping the septic
tanks, repairing or replacing pumps, and replacement of septic tank baf�les are examples of
acceptable repairs. If the septic system needs major maintenance, such as septic tank
replacement or drainfield replacement, connection to the sanitary sewer system will be required.
If there are any questions regarding this letter, please contact me at (612) 249-4600.
Respectfully,
Chris Pence
On-Site Systems Manager
Telephone(612)?A9-4600 • Fax(612)249-4616
�°�
0 0
-�j�:��- CITY of ORON4
,� �����,�� ;-- ,,
�� `. - ��, Municipal Offices
'� `,.�- :.�+�.:�
�! � �.� G Street Address: �15a-a49'y6o 0 Mailing Address:
'�Hp'¢'� 2750 Keiley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
To Current Owner: Address: ��"3� Ly�^� �v t-
City Ordinance i99 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
STEM CONFORMIT'Y 1-3 : �
1 "CODE SYSTEM"'An TSTS which meets all the location,design and construction standards ofthe current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An LSTS which dces not meet all the location,design and construction standards of the current Orono
Municipal Code but dces meet the duce foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an iam�inent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited LST'S;an ISTS located witfiin a�signated 100-year flood plain,any ISTS which may
or may not meet all the location,desiga,or cons�uction stan�rds of the curtent Orono Municipal Code and which is failing for any
reason;and any ISTS witi�less than three feet of unsaturated soil or sand between the dish-ibution device and the limiting soil characteristics.
TANK CONDTTION(5-7):
�uvspection indica#es:
Pumpout not needed at this time.
6 Septic tanks must be pumped out#his year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped 6-2.�t-Uy ).
Make sure seatic tanks are aumaed throush man6ole and not throush white insaection uiaes. This allows for the arocer
cleanins. Keea water softner and iron filter dischar¢e out of seatic svstem to prolon¢life of drainfield. Ask aumcer to test
atarm float to verifv alarm is still workine in vour house. The alarm warns owner that seata$e is about to backua into basement
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three yeazs,they should be pumped out now.
D IELD CONDTTION 8-10 : �
Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield.is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 9U days.
COMMENTS: M O•..�,.J �- Scp'1-.�(., �'a���� I Oc��� O�_
���ii-1�e� �' l��
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the eveut that this inspecrion report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on Uie available infornoation.
� ������. �''�
C� o``�
_ ��I ��'��'" o� �R.�1�'�
::�.:;.*,: ,
;';tt�;��':'��r "'_ '�'''f
� 'Li".�`4��.���'�.L^,:��.�'r' � Municipal Offices
.\`�' !y.'�`t,��v`,,rtir`�4",� �'/
i6 �1
� ;��;�..�°h;;�::,� � Mailing Address:
�'�.;..'� "��.,.,,�,�;.r:;.3:�'��,��?�� Street Address:
�.-���A .��`��.''' �� '% 2150 Kelley Parkway P,O. Box 66
`•�• kES'L3� i%� Crystal Bay, MN 55323•0066
�� Orono, MN 55356
To: The Cun:ent Owner of Address , � 3 S r '��''�"A�
City Ordinance requires that onsite sewage treatment systems iiz Orono be
inspected on a periodic basis. The.onsite sewa?e treatment system at the above
address has been inspected and the following is l:nown about the system. A
sketch of t11e known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Thi-eat
Yes �No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
le�al action.
System Identif'ied as l�Ton-Compliant
Yes �N�
If yes, system must be brouaht into compliance by:
Decembez-31,2007 �
December 31, 2010
Other
Septic Tani:(s)Pump out Needed
Yes �No
The City recommends the septic tanl:(s) and/or lift tank be serviced a�ld pumped
out every tYuee years. City records indicate the tank(s) were last pumped out on
�;�,2�-i�-'1 . The tanl:(s) should be cleaned through the mailhole and
not through the inspection pipes,tlus allows for pzoper cleaning.
Camments:
�.. , �_
Inspect� & ' _ Date of Inspection � '��'� �
- �
Teleohone (9�21 2�9-46U0 ° Fa.r- (9�2:J 2�9-461h
�o�.
0.� ; O . .
���y°�� � CITYof �RONO �
i.
i �
� ����� ��� .MqIIICI� Q�CtS
�' ���'�" r G . sveet Adaress: . �.
�. �� � Og� Mailin�Addrou: .
EBII , _ 2750 Kelley Parfcway P.O. Box 66
_ � Orono� MN 55356� .� Crystal6ay� MN 55323-0066 .
. 95d-�4q-y600 � �
To Curreat Own.er: Address: (a�S Ly�`-��� . /t v�
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatmeat system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY 1-3 : (
1 "CODE SYSTEM"M ISTS which meets all the location.daign and eonstrucdon standards of the eeurent Orono MunIctpal Code.
2 "COMPLIANT SYSTEM" M IST'S which dou not meet all the location.daign and oonstruction standards of the eurrent Orono Municipal
Code but doa meet the three foot separation requirement or two foot requircment for systertu lnstalled 1996 oc earlier,and which is not failing or
an imminent threat to public health or safery.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS loeated within a daignated I00-year flood plain,any ISTS which may. .
or may not meet all the location.daign,or con4wction standards of t�e current Orono Municipal Code aad which is fafllag for aay reason;aad
any ISTS with leu than three feet of unsaturated soil or sand behveen the dis�ibudon devia and the 1'uniting soil eharactetistia.
TANK CONDITION(�-:71: � . �
Tank inspection indicates: � . - , . . .
U Pumpout aot needed at this time. �
6 Septic tanks must be pumped out this yeaz (city code requires tanks to be pumped out once every 3 ytars.
Tank was last pumped q-�t-o 1 �, •
Make sure seotic tanks are oumoed through manhole and not through white insoection ptpes
This allows for the proaer cleaning.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank:
RAINFIELD CONDITION[8-iCE�: �
8 Drainfield'u dry,no surfacing eviden�
9 Some evidence of surfacing,not critical yet '
10 Drainfield'u saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Iaspector � �
immediately.Repairs must be completed within 90 days. .
COMI/1ENTS: �`'�0 v„� c�r.L� S t�+.L �-�r���5 � e�i� 0)C
� -z� -d a- �� ��.�^
Date of Inspection Matt Boltecman- SepBc System Inspector
Note:ln the event thac this inspeccto�rcport is used w satisfy the requuements for a mortgage or othu transfer of properry.be advised that this repoR doa not guaranue
or artit�that an acisting system wiU continue to funetion propedy.but is mecely an opinion of the adequary otthe system uade�enrrent condidons based on the mu'labte
infacmation.
� o�
, o 0
' CITY of ORONO
, .
''a l� �.�' � ti! Mun;cipal offtces
�\�� n : a,, G'ti�
'��. ,t �� ' ` �:�� Stroet Addross: Mailin4 Addross:
�'yrgg0g' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
August 3, 2000
C. Paul& Rae H. Pesek
1235 Lyman Avenue
Wayzata, Mn 55391
Dear Mr. &Mrs. Pesek:
An inspection of your septic system was conducted on August 2, 2000. A summary of the
inspection is below.
Septic Tank Condition
1. Pumpout not needed at this time.
The septic system is a compliant system, meaning it meets all or most current City and State
Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This
list is enclosed simply for your reference in case your septic system needs maintenance in the future.
Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built
drawing is enclosed showing the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
Respectfull ,
_ �C��/
Chris Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,
be advised that this report does no guarantee or certify the eaisting system will continue to function properly,but
is merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
%/�O�
O . 0
h,:�� ,� CITY of ORONO
� �:�;.�; :��,��� �ti M��� ot��
, ,�,���.. ,
\,t�� , .�:, ;��.�''�G Street Address: Mailina Addreu:
'!$�p�" 2150 Kelley Pa�kway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: �V Address: ia35 Lyman Ava.
Permit #'s: 7497, 9026 Dates: 7/10/84, 5/a9/87 Contractors: E. J. Peterson Co.-Keith
Clark, Jerry Johason
(This is [� an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears' to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil lavel is [� � or is aot [ ] id.atified uader this septic system. If the
saturatad soil lwvel is aot idea�'ifisd, this classificatioa is subjact to rsvisioa.)
�_CONDITION (5-9) : 5
( 5J Pumpout not needed at this time.
�'� Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are ( ] or ara aot [ ] water tiQl�t or the condition is [� unkaowa. If tbe tanks
are aot coafirmed to be v�atertiQht, this classificatioa is subject to revisioa.)
�IN_FIELD CONDITION (11-14) : il
(11� Drainfield is dry, no surfacing evident.
��l' Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
CONII�2ENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 3 feet and the system is compliant.
�l�-�
Dat of Inspection Septi ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Tekp6one (612) 473-7357 • FAX 473-OS10
CITY OF ORONO �O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�S TRBAT�N'!.'
� � INSPECTION REPORT
� G�
�9kEsao4`'�
Owner: C..� �QA/' ��h Address: L— .
Permit �'s: Dates: — Contractors: - 1 ��
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �L an existing system [ ] new construction)
SYSTEM CONFORMITY C1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage ir�wt
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time ot installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; eny
system which may or mey not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic �l.has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5� Punpout not needed at this time.
Cb� Solids accumulation in tanks indicates they should be ptmped out this year to help prevent future problems.
7 JOIIQ� BGGVIRJlBLIVfI Ifl Lef11C�3 1S BL�r a eve . 8fl � �� n
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface�dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each
tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation>.
If tenks have not been punpeci out within the last three years, they should be punped out now.
DRAINFIELD CONDITION C11-14):
Dr,e�fietd inspection indicates:
� Drainfield is dry, no surfacing evident.
Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector
immediately. Repeirs must be completed within 90 days.
14 Drainfield extent end condition unknown.
LIMITING SITE FACTORS (slope.setbacks.etc.): J�—
.r
POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table.etc J: �
COMMENTS:
Date of Inspection S tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to f�mction
properly� but is merely an opim on of the adequacy of the system under current conditions based on the available
intormet�on.
This report must be kept on the premises with the system locstion and punping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 a � ON—SITE SEWAI3E TREA'1'l�NT
,� � INSPECTION REPORT
ti
p ��9x'Esxo4`'�c,
��'� r�
Owner: Address: ����-�,/I')YJIY� /tb�—
Permit �'s: Dates: l3'g — — Contractors: �iTI�T�'�7Y�CD✓fYYt/�h3lJ?'�
City ordinance nurtiber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �an existing system [ ] neW construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current seWage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface Waters.
3 "NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic 'iy�has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identiYied, this classification may be subject to revision.)
TANK CONDITION (5-10): �
T,aq�c inspection indicates:
(�/ Pumpout not needed at this time.
6 Solids accunulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 5olids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surtace dischar$e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each
tank at next pu�wut. If tanks have not been pimiped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been punped out within the last three years, they should be punped out now.
DRAINfIELD CONDITION (11-14):
Dr nfield inspection indicates:
� Drainfield is dry, no surfacing evident.
�� Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): `�J
COMMENTS:
ate o Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current corxiitions based on the available
informatton.
This report must be kept on the premises with the system loc�tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner