Loading...
HomeMy WebLinkAboutseptic info f ,. .�o�,. O O CI'TY OF ORONO � � � Municipal Offices �, 3treet Address Mailiag Address: � G�' 2750 Kelley Pazkway P.O. Box 66 '�.9 �i Orono,MN 55356 Crystal Bay,MN 55323-0066 kEsBo�' To: The Current Owner of Address 45 LUCE LINE RIDGE City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes _/ No ►/ If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other Septic Tank(s) Pun�out Needed Yes V No The city recommends the septic tank(s) and/or lift tank be serviced and pum�ed out every three (3) years. City records indicate the tank(s)were last pumped out on S -D`-� The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: .. Inspector: Date of Inspection: ��a� Telephoae (952) 249-4600 • Fax(952)249-4616 www.ci.oroao.mn.us � _ . � ' � i �. � To: Orono residents on mound type septic systerns From: Willie Gibbs, ISTS Manager Date: May 10,2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent(the fiquid left after the "othe�' stuff has been removed) in the summer time and allows the mound system to hefp breakdown nitrogen in the efFluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the winter time. Even human foot traffic can cause ftost to penetrate the mound resulting in potential freezing problems. Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember,that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound system please feel free to call me, I can be reached at 952-249-4626. 1 :/.' ''IO _�..\ .!�� � � �•,,,.1 /�' Q '`\ �� � �1 CITY of OIZ4N0► I , r ,6 � II `��'. � '' � ��,,;' Municipal Offices �,,',\�,� � �. � � \. G , , Street Address: Mailing Address: ��9.kE,$.Kp'4��' 2750 Kelley Parkway P.O, Box 66 __.��__... Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Current Owner of Address L� � �- v C'e � �'1-3� `� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other ' Septic Tank(s ump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on c� -2�{ O � . The tank(s} should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: �. Inspector: ��L1 ate of Inspection `l ' �� Telephone(9�2) 249-4600 � Fax(952) 249-461b www.ci.orono.mn.us � �� . O :. O ���� �� � �� -� CITY o� ORONO � 'i����,;�':�� b+ i���. :,. ° ti Municipal Offices '�, ���;�-�;����, Gti � .,.��,..�� .t � Street Address: Mailing Address: '��Hpg' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 To Current Owner: Address: `�'`� ��C, ��f�Q.- ��U,�� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. STEM CONFORMITY (1-3): � 1 "CODE SYS'TEM" M ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYST'EM" M ISTS which does not meet ali the location,design end construetion standards of the current Oroao Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent throat to public health or safety. 3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not mect all the location,design,or construction standards of the cucrent Omno Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsatutated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-71: � � Tank inspection indicates: � S Pumpout not needed at this time. �Septic tanks must be pumped out this yeaz (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �-Z`i—o i ). Make sure septic tanks are pumued through manhole and not through white insnection pipes. This allows for the proper cleanin¢. Keep water softner and iron filter dischar¢e out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : Drainfield is dry,no surfacing evident. Some evidence of surfacing,not critical yet. � 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. co�N rs: ►`^e v,�.� i oa�LS 41�_ p u~�� S c�t;ti.- -��^k�S S v�ri� �ac�� , ���-03 �� � Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection roport is used to satisfy the requirements for a mortgage or other trsnsfer of property,be advised that this roport does not guaranue or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy ofthe system under cucrent conditions based on the available i�formation. Telephone(952)249-4600 • Fax(952)249-4616 www_ri_nrnnn_mn_un �o� o ::., _ o ��y�-��?� CITY of ORONO � ;bl�'�:������� '" � ��� ,�,.�;�;� ,�ti M��;� otn�� � �'''��_�"� G Street Addross: '�'�`;�;,�g�i Mallin�Addreu: �'E*gg0 2750 Kelley Parfcway P.O. Bax 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: 5 c��''•�S �01�� Address:_ �s Z�c< 1;�e ►2,d��_ Cin•Ordinance 199 requires that each existing on-site sewage treatment rystem in Orono be inspected every nvo years. The on-site se�vage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � lO °CODE SYSTEM" An ISTS which meets ail the location,desigi and constivction standards ofthe cuarnt Orono l�funicipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet ail the locatioq design and constcuction standards of the cun ecrt Orono Municipal Code but does meet the three foot separatioa requiremrnt,and which is not failing or an imrninrnt threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located withia a designated 100-year flood plair�any ISTS which may or may not meet all the locatioq design,or construction standard4 of the cuaetrt Orono�tuaicipal Code and which is failing for any reason;and any ISTS with tess than three feet of unsaturated soil or sand between the distributioa device and the limiting soil characteristics. T.�NK CONDITION(5-10): C� Tank inspection indicates: � Pumpout not needed at this time. � Tank must be pumped out this year (city code requires tanks to be pumped out avery 3 yeazs. Tank was last pumped �-����g �, 7 Solid4 accumulation in tanks is at a ctitica!a critical leveL Tanks should ba pumped out as soon u possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspaetion risers missing-tanks could not be inspected Inspection risecs(4"dia.pipe)must be installed in each tanlc at ne:ct pumpout If tanks hava nut been pumped out within tha last three yeazs,they should be pumped out now. 10 Inspaction pipe is located directly over tank ba�le(does not give accurate measuremeat of solids accumulation). If tanlcs have not been pumped out within tha last three years,they should be pumped out now. DRAINFIELD CONDITION 11-14 : �1 1 Drainfield is dry,no surfacing evidrnt 1� Some evidence of surfacing,not critical yet 13 Ihaintiald is saturatad and visibly discharging untreated efflurnt W tha surface. Contad the City Inspector immediately.Repaits must be complated withirt 90 days. 1-� Drainfiald e�ctent and condition unknown CONIl�IENTS: S �S�-e� \o�1�s � '� � -I"� —b \ �� � Date of Inspection Septie System Inspector ' Note: In the event that this inspection repoR is used to satisfy t}u requireme�for a moRgage or otha traa4fer of property,be advised that this repoR doa not guarantae or cettiCy that an a�tisting systam wiil continue to function properly,but is mecely an opinion of the adequacy of the system under cusrrnt rnnditions b�sed on the available informatioa CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r$), . � INSPECTION REPORT `C�� G~ 9kESH�4'� � [ ` Owner: � �f�'Yy1L s l� � Address: �!S j�r_e . �(!�_�lQ���Q �J�S•3,j�nj� Permit �'s: �:>L�J Dates: �� '-�.)' �� Contractors:_�i 11�11- ��C• City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is xj an existing system [ ] new construction) /� STEM CONFORM[TY 1-3 : � 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current seuage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input Without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and uhich is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic� has or [ ] has not been identified at this time. If the limiting soil characteristic has not been idenfified; this classification may be subject to revision.) TANK CONDITION (5-10): inspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be purtiped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be purnped out Within 48 hours to eliminate surface dischar�e. 9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. ]f tanks have not been pumped out within the last three years, they should be punped out nou. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accurtiulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINfIELD CONDITION C11-14): 1( field inspection indicates: Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City ]nspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): , � � POTENTIAL FOR SYSTEM FAILURE (depends on soils,uater table,etc.): �1LJ COMMENTS: S� � Date o Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal eay, MN 55323-0066 a � ON—SITS SEWA(;E TREATl�IIrNT INSPECTION REPORT ti ��� �G �kESII��' Owner:�YAm�� �/�� Address• Lr� �� � Permit �'s: Datea: ��1�""� Contractora: City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been �nspected and appears to fall into the category checked below. (This is� an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or mey not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or send between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic U4 has or [ ] has not been identified at this time. If the limiting soil characterist�c has not been identified, this classification may be subject to revision.> TANK CONDITION C5-10): Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids eccunulation in tanks indicates they should be punped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. fianks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each tank at next punpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection p' ' a ver nk ba (does not give accurate measurement of solids accumulation). If tan s have not en ou wit �n e las three years, they should be punped out now. DRAINFIELD CONDITION C11-14): D�fietd inspection indicates: Drainfield is dry, no surfacing evident. 2 Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. L1MITING SITE FACTORS Csloae,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table,etc.): �� COMMENTS: Date of nspection S tic S tem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of p�operty, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an op�nion of the adequacy of the system under current conditions based on the available tnformation. This report must be kept on the premises with the system locstion and punping records. WHITE COPY/Inspectors File YELLOW COPYIHomeowner � o� 0 0 ��Y��,� CITY of ORONU . > > ,#,��,f�,, ;� �, ''� ���; ,F�� n;:� ti Mnnicipa� ot'fces �' f, •;'�1,,`',�•� 'i '�' �,�9�,;,�������¢.�G SVeet Address: Mailing Address: $EggO 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 n Owner: �e���-s /� Address:45 Luce Line Ridge Permit #'s:1453, 8500 Dates:ll/17/88, 10/15/96 Contractors:Ritter Exc., Ritter Exc. �his is (� an existing system [ ] new construction) YSTEM COMPLIANCE (1-3) : 1 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level f�j has or [ ] hss not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION 5-9 : 5 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have r�ot been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks (� were .or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this clasaification is subject to revision.) INFIELD CONpITION 11-14 : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (svstem acre and condition, soils, etc. ) : low COMMENTS: j�- �j��� �a�/�� /����� '"'!�� ,.� Date of Inspection Sep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWA<3E TREA'1'1�NT � � INSPECTION REPORT ti ���kES�I���G Owner: . 1(�m�S �T�JIY?'\ Address: 7J �—�G �.-1/�� 1C�U4�_ Permit #'s: Dates: ��`�7 gg Contractors: 1\1� �JlG, City ordinance number 700 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is p�ll. an existing systc�n [ ] new construction> SYSTEM CONFORMITY C1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas instalted according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants �nto ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic pQ has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): � T� inspection indicates: Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be p�p�� out this year to help prevent future problems. 7 5olids accumulation in tanks is at a critical level. a'f nks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each tank at next pumpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is Located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been p�mped out within the last three years, they should be punped out now. DRAINfIELD CONDITION (11-14): Dr,d7lnfield inspection indicates: tlY Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector immediately. Repairs must be completed Within 90 days. 14 Draintield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): �� COMMENTS: Date of Inspection Se tic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system loc�tion and p�ing records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER G � ADDRESS l �-/ �N PERMIT NO.'S. �� DATES !��< a g CONTRACTORS � �' City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address haa been inspected and eppears to fall into the category checked below. (This is �an existing system ❑ new construction) �� Meets or exceeds current City standards in ali respects relating to design,construction,and location.Appears to be operating pro►�riy. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generaliy in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. � System may or may not meet current City standards for design,construction or location, but is failing to properly treat and 4 dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testi�g will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a pe�mit before work is started. SYSTEM CONDITION (m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not �Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks Solids eccumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drain ield i�apection indicetes: should be pumped out as soon as possible. �rainfield is dry,no surfacing evident, ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risen missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risen (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. O Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Futu e Expansion ❑ Soil table,and system condition) �Adequate �-High water table ,�Low ❑ Fair O Lot size ❑ Medium ❑Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: �'� 's 9� Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information, This report must be kept on the premises with system locatio�and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner CITY OF ORONO �a� ADDRESS � Connected to CODE SEPTIC SYSTEM INVENTORY CARD Municipal Sewer Address �7 S uC-��N� �/DC•sC property I.D. 3I'��O�Z3 3'1 �� WELL DATA �Moundrd trench L� Z ���,K� � I I System type � Other Legal Description Il/�S � p m Ar C ^l r Permit No. �"Ta 3 Date of permit � � Installer �i�� y XL0.�4 vt� m � � � No. Bedroo� Garbage � � d f Buiiding type ���. or GPD Laundry � Dishwasher h Disposal h � o p ( o m� � SEPTIC TANKS: Material Capacity 1) 2) � ���U�,�4� " m �8 Proper outlet and inlet�Baffles �k Liqu d depth to RO eve m � � � Height of tank bottom above water table ��_Distan�to nearest buildi g N � � � DRAINFIELD: Total length of lines � Number of li s Tren wi � � JOisD'Ro'c�E JB / c � � Total treatment area(sq.ft.) 3�� ��$�4nGt Height of d infi b re wa e � m `„ Q � 3/�'=��' " Ro k / __. � � �rr Type of filter materialouiC►rG�rld So ype a $ � m / / A�, / M w Distance from nearest bldg. � Tile s � / �V� L� min/in ° � m c q �� /� c0/i � O � Depth of fiil over drai�field — Dept roc ile under tile .� E � " p d �U '�+ G�R —, ��I`fi �✓eli 7` 1-aa �t INSPECTION RECORD PUMPOUT RECORD SKETCH DATE COMPLIANCE DATE GALLONS " uS� 8 3'- -"p � n � � ' —� �{��`=;I' ����O !� ��l.s 9� ' - ^°'e �' �— T�►k t �� ,�, 6 - m ��_ ��=9� c�o z� I z ,eb -��- �� �, „ �� �— 3� �pp�p io o c�.+ �.g� sz� �� ���- �,��-��► +���:�. r i��..��F��_ o _,_ T�.ti�. � $39 , �h 3o Q ?Sa o �v� 3�b S7 a.�� � s,� 8� q�� fk► �z` 4 3 � i°°'� Cj �,.. __ --, ,_ ____ __ � � � � �un� ?X 3� .� - �p ia�c sa ^ �nclude: �) WeTf locatiori 2) Distance from house to septic tanks,dist.box, and drainfield C— CONFORMING S —SUBSTANDARD N —NONCONFORMING 3) North arrow and road