HomeMy WebLinkAboutseptic info �°� _
o : o
�� CITY of ORONU
-����:���
,� 't�����r5��- . �.
�1_ : n" �� MIlII1C1� ��CPS
1�'� 1��.�� �'/''�
�`y � i4N� 4 G Street Address: °I51-a4�i—y6�0 Mailing Address:
�'9���"'p'¢'� 2750 Kelley Parkway P.O. Box 66
ESI;
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: ��� �� �`t�^'' �i��'�c-
City Ordinance 199 requires that each existing on-site sewage treahnent system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below.
S�'STEM CONFORMITY (1-3): �
1 "CODE SYSTEM"An ISTS which meets all the location,design and consh�uction standards of the cucrent Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not�et all the location,design and construc6on standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an im�inent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an LSTS located within a designated 100-year flood plain,any ISTS which may
or may bot meet all the location,design,or construction stanc�rds of the current Orono Municipal Code and wluch is failing for any
reason;and any IST'S with less than three feet of unsaduated soil or sand between the distribution device and the limiting soil characterisdcs.
TANK CONDITION(5-71:
Tank inspection indicates:
� Pumpout not needed at this time.
6 Septic tanks must be pum ed out this yeaz (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped �—Z.ai-0� ).
Make sure seatir tanks are aumaed throu¢6 manhole and not through white insaection aiaes. This allows for the aroaer
cleanin¢ Keea water softner and iron filter discharee out of seatic svstem to arolon¢life of drainfield. Ask uumaer to test
alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner that seata¢e is about to backua into basemen�
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : b
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield.is saturated and visibly discharging untreated ei�luent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: l�.�v�� �— S c 3Z �--�,.,� �o�k,- 6�C. _ Nt� ��f C
_�pS0.1 a— �CC��S �r� ri,fv� ,
�-20 -oy c�.� ���
Date of Inspection Matt Bolterman - Septic System Inspector
Note: tn the event that this inspec6on report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available information.
o �
� �
o �,... o�
`��:�:�:4�,.- �ITY of UIiONU
a! t�����,��.��xf'. l�• �'"
z�� +�r, � �, MunicipalOffices
`� � ���'s���°���� �
'� �. �f,,....tis}'a'�`�'6 �j
� � ���;f.���►.�.�t�� Street Address: Mailing Address:
9�`''" '''p4�' 2750 Keliey Parkway P.O. Bax 66
E3II � Orono, MN 55356 Crystal Bay, MN 55323•0066
�3� S G..0� �rj�
To: The Current Owner of Address �
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The.onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes �_
No
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attomey for
legal action.
System Identified as Non-Compliant
Yes �No
If yes, system must be brought into compliance by:
December 31,2007 � ,
December 31, 2010
Other '
Septic Tank(s)Pump out Needed
Yes __� .
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three yeazs. City records indicate the tank(s)were last pumped out on
�_a �-o� . The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning. ,
Comments:
�1�� ����
ec : "'r ��� Date of Ins ection �" ��
Insp tor p
Telephone (9�2)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
�o�
o ,, o .
������=� CITY of ORONO
� ���; , �
�
y r,�.. �,y
� : -�'
� �� ��, 'I�.3' j� G�lSr Municipal offices
.� ��,��•�';���'�"' Street Addross: Mailin�Addreuc
�Eg�gOg'� 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
95d-�49-4600
To Current Owner: Address: a3a� ��'�v`e`" ��rcle
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
lO "CODE SYSTEM"An ISTS which meets all the location,design and conswction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which dces not meet a11 the location,design and conswction standards of the current Orono Municipal
Code but dces meet the three foot separation requinment or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent throat W public health or safery.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year fl�d plain,any ISTS which may
or may not meet all the location,design,or conswction standards of the curtent Orono Municipal Code and which is failing for any roason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(-;.?: �
Tank inspection indicates:
� Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped �-�—b 0 )•
Make sure seatic tanks are pumued through manhole and not through white insaection aipes.
This allows for the uroaer cleanin�.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
DRAINFIELD CONDITION(' ` ��: $
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: S�IS�c� IoG1C5 O�'., '�',�Sfi �'A�k Co�it� u5� pu�•p:�� �
-�_�.-pa ��
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the rcquircments for a moRgage or other transfer of property,be advised that this repoR does not guarantee
or certify that an existing system witl continue to function propedy,but is merely an opinion ofthe adequacy ofthe system under currcnt conditions based on the available
information.
� �
��
;�� 0 0 ����
� � � !�i CITYof ORONO
J � - v �
���;�', 1' .`p`- �C �=� l4� Municipal Ot�ices
',, ,� �� �,;�. _�.� � �,ti�
�� \� : '� ' ':`�".ry � Street Addross: MaUin�Addrou:
�`��;gg0�'�� 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
July 7, 2000 ,
Stephen& Dana Wood
2325 Longview Circle
Long Lake, Mn 55356 .
Dear Mr. & Mrs. Wood:
An inspection of your septic system was conducted on July 6, 2000. A summary of the inspection
is below.
Septic Tank Condition
1. Pumpout not needed at this time.
The septic system is a compliant system, meaning it meets all or most current City and State
Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This
list is enclosed simply for your reference in case your septic system needs maintenance in the future.
Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built
drawing is enclosed showing the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
Res ectfully
.
�
C is Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,
be advised that this report does no guarantee or certify the eaisting system will continue to function properly,but
is merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www ci.ornno.mn.us
� o�
0 0
, , J:t��� ,� CITY of ORONO
�r�, ��` � �5r MunicipalOffices
E �.T��, �;� �
�`�� ��=I�v'�`��`�" G Stroet Address: Mailing Address:
� :,. � �, � �i
�'EgH04' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: � �i Address: 2325 Longview Cir.
Permit #'s: 315 Dates: 10/12/87 Contractors: Jerry Johnson
(This is [ K] an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is �] or is not [ ] identified under this septic system. If the
saturated aoil level is not identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9O Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are � or are not [ ] water tiqht or the condition is [ ] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
D�AINFIELD CONDITION (11-14) : 11
�ainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL �'OR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 3 feet and the system is compliant.
_a_ � �
�ate of Inspection Se ic System ns ec or
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITL SEWAGE TREA'1'd�NT
INSPECTION REPORT
ti
ti
��9k og�G
EsH
Owner: ��l/�l'� G'l/ri[eC,1 Address: ��� �41/181� ��
Permit #'s Q Dates: ��1��� Contractora:
City ordinance nuinber 100 requires that each on-site sewage treatment system in Orono inspected on a regular besis.
The on-site sewege treatment system at the above address has been inspected and appears to fall into the cetegory
checked betow.
(This is �9-an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system wt►ich meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and �fiich
is opereting satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which mey or mey rwt meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic � has or [ ] has not been identified at this time. if the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONOITION (5-10): �
T� inspection indicates:
Punpout not needed at this time.
Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. Tanks should be puiped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed �n each
tank at next pumpout. If tanks have not been punped out aithin the last three years, they should be punped
out now.
10 lnspection pipe is located directly over tenk baffle (does not give accurate measurement of solids accumuletion>.
If tanks have not been punped out within the last three years, they should be punped out now.
ORAINFIELD CONDITION (11-14):
D nfield inspection indicates:
1�1 Drainfield is dry, no surfacing evident.
'f2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS Csloae,setbacks.etc.):
POTENTIAL FOR SYSTEM FAlLURE (deoends on soils.water table.etc.): ��J
COMMENTS:
Date of Inspection ep c Syst m Inspector
Note: !n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properlyi but is merely an op�m on of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system locetion and punping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeownar
CITY OF ORONO �O�
Municipal Offices O O
Post Office eox 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATI�NT
� �, INSPECTION REPORT
ti
���kESH���G
Owner: ��1�Ptt'� //�.Q�L� Addre s s: �Oc���/�P,z..J Ci i:
Permit �'s: .�).� Dates: �0`�oZ�g7 Contractors: ./('VI'i/ J�hSDY�
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is ,� an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): (
•{--
"CODE SYSTEM��-A system which meets all the tocation, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or ,p�L has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.>
TANK CONDITION (5-10): �
T�Qk inspection indicates:
(�J Pumpout not needed at this time.
b Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. 'fanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each
tank at next punpout. If tanks have not been p�rnped out within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been p�mped out within the last three years, they should be punped out now.
DRAINFIELD CONDITION C11-14):
D� field inspection indicates:
Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE Cdepends on soils.water table,etc.): ���
COMMENTS:
Date of Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements tor a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system locstion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner