HomeMy WebLinkAboutSeptic info � ��' _
O O
�i CITY of OR4N0
_��:��.,
�a '����'��}- _ �
��, s�; "''. Munici�l offices
` � � .�r. ,�,
�,t ' �„'��.FF..,,'�,�G Street Address: °ISa-�49-y6o � Mailing Address:
`�x'�HO'g' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: v��� �^5 v'e`� C:� L 1�
City Ordinance 199 requires that each e�cisting on-site sewage treatment system in Orono be inspected every two years.
`The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below.
SYSTEM CONFORMIT'Y (1-3): �
1 "CODE SYSTEM";An ISTS which meet4 all the location,design and construction standazds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which dces not meet all the location,design and consiruction standards of the current Orono
Municipal Code but dces meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an i�inent threat to public health or safety.
� "NON-COMPLIANT SYSTEM" A prohibited ISTS;an LSTS located within a designatsd 100-year flood plain,any ISTS which may
or may riot meet all the location,design,or construction stan�rds of t.�e current Orono Municipal Code and which is failing for any
reason;and any IST'S with less than thrce feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDTTION(5-71: �
Tank inspection indicates:
5 Pumpout not needed at this time.
r6�eptic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 yeazs.
�JTank was last pumped �-3^0� ),
Make sure seatic tanks are pumped throu¢h manhole and not throu�h white insaection aices. This allows for the uroaer
cleanin�. Keen water softner and iron filter discharse out of sentic svstem to arolon¢life of drainfield. Ask uumper to test
alarm float to verifv alarm is still workine in vour 6ouse. The alarm warns owner that seata¢e is about to backua into basement
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: �s"=���c\� iS ror.— C o,.— \:�.,,�y— d-- r1�S-r �� r� 1��t �
b �t=3 �—Zo�v v� S� �-,, L 3-���1 � Sti.�.�r Zoo� ,
� �za —Qy Glr—�
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this iaspection report is used to sa6sfy the requirements for a mortgage or other transfer of property,be advised that this report dces
not guarantee or certify that an existing system will wntinue to function properly, but is merely an opinion of the adequacy of the system under cutrent
conditions based on the available infoimation.
� ��
o �, o . .
����� ? � CITY of �R4N0 � �
� �����' .
� , � .t '1 � .Munlcipal Offitces
'�,�? ' �g,'�iG . ' Street Address: Mailin��dress: ' .
� , . 2750 Kelley Parfcway P.O. Bax 66
_ � � - Orono. MN .55356� .� Crystal Bay, MN 55323-0066
. 95d-�4q-y600 '
To G�urent Owner: Address: a a7 S Lo�� v:Q�-�- C;r L��
City Ordinaace 199 requires that each existing on-site sewage treadment system in Orono be inspected every two years.
The on-site sewage trearrneat system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMIT'Y (1-31: 3
1 "CODE SYSTEM"M ISTS which meets all the locat�on�daign and construc6on ssandard4 of the evnent Orono MunIcipal Code. ' '�
2 "COMPLIANT SYSTEM" M iSTS which doa not meec a11 the location.daign and constructIon standards of the eurrent Orono Municipal
Code but docs meet the ttuee foot separation nquinmeat or two foot requirement for rysums installed 1996 or earlier.and which k aot failing or
an imminent threat to public health or safery.
3U "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS locaud within a daignated 100-year tlood plain,any ISiS which taay.. .
or may not meet all the locatlon.daign.or construction atandards of the cucrent Orono Mimtcipal Code and which is failing for any reason;and
any ISTS with less than three fcet of unsaturated soil o�sand between the d'uui'bution devia and the limiting wii eharacteristla.
TANK CONDITION(�-:71: s �
Tank inspection indicates: � . . . . .
� Pumpout aot needed at this time. -
Septic tanks must be pumped out this yeaz (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped 6-3-O], �. •
Make sure seatic tanks are oumned through manhole and not throvgh white insoection otnes
This atlows for the orooer cleaning.
7 Inspecrion risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank:�
FI LD C NDI'fI0 l� : �_
8 Drainfield is dry,no surfacing evidenL
9 Some evidence of surfacing,not critical ye� •
10 Drainfield is saturated and visibly d'ucharging untreated efflueat to the surface. Contact the City Inspector � �
immediately.Repairs must be completed within 90 days. .
COM�NTS: �JC ";`��:��(� \S �t�- (C�M��;�t�-�' c�n� (1�SSr bz lC��''t(�d S�/' 11�1-ZOI�
c����°��z ;�S(�<<�--_o_ a:cc � � �:�s,- ��7t-c.� �^K .
�� zz-���- G��
Date of Inspection Matt Bolterman- Septic System Inspeccor
Note:in the evcnt that this inspection report is used to satisfy the rcquirements for a moctgage or other transfer of property�be ad�rised that this rcport doa eot guarantee
or artiPy that an existing sysum wiU continue to function properly�but is mereiy an opinion of the adequary otthe system under entreat con�dons based on the svailabte
iniomiatioa
I
Y
� �1V'`
O`S�\'� .. . O O
�.��.::��:::�:., ciTY of o�oN
`��,���'•��- .
r'! t�y�s'�'�����_�'�:��• � Municipal Offices
�}{�,�,.�1}/��`,,�1,:.:% i
1\ �' M��y Tf�'Y�t i/�;`�' �
\ �- ��'�.�'r s��`���' G Mailing Address:
�'�� ��;,r�.� �.��,� Street Address:
�,,� :; P.O. Box 66
� 9kEs�p� 2150 Kelley Parkway •
� Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Current Owner of Address ���S � v�� ���''J ,
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The.onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall. �
Imminent Public Health Threat
Yes �
No �
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identi�ed as Non-Compliant
Yes ''�
No
If yes, system must be brought into compliance by:
December 31,2007 �
December 31,2010 ��
Other
Septic Tank(s Pump out Needed
Yes '
No IThe City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s)were last pumped out on
�„ .. 3 -va . The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleaning.
Comments:
Ins ecto � ~ Date of Inspection J "��'
P
Telephone(952) 249-4600 • Fax(952)249-461b
www.ci.orono.mn.us
� o�
O�:� O �
��� CITY of ORONO
���
,;��:1 �
�� r,e� —:��,'��� �,
� �'ill•4 v �.�� G~� Mri�C�� ��CCS
� ,� Street Addroas: Mailina Addrou:
��,+gH�04'� 2750 Keliey Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
July 7, 2000
Steven&Deborah Buchholz
2275 Longview Circle
Long Lake, Mn 55356
Deaz Mr. &Mrs. Buchholz:
An inspection of your septic system was conducted on July 6, 2000. A summary of the inspection is
below.
Septic Tank Condition
1. Pumpout not needed at this time.
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City
Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic
system must be replaced by December 31,2010.
Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also
enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the Ciiy Offices at 249-4600.
Res ectfully
` ���
�s Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements far a mortgage or other transfer of property,be
advised that this report does no guarantee or certify the existing system will continue to function properly,but is
merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www ci.orono.mn.us
���
. O O
a h�� CITY of ORONO
�ti��'T '�
,•� °�� r��� �l�i Municipal Offices
� `�;``� ��� �� G
.� '� :����p���.�,�� � �Street Address: � Mailin� Addrou: �
'�EggO�' 2150 Keliey Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: , ��/ � �lJ ��'� Address: 2275 Lon�view Cir.
Permit #'s: 6129 Dates: 10/1/80 Contractors: Sullivan
(This is [�] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
�� codes and is functioning properly.
/ 3 / Non-Compliant System: System may or may not meet current City standards for design,
�•� construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The aaturatmd soil level is [x] or is aot [ ] identified uader this septic system. I£ the
saturated soil level is not identified, this classification is subject to revisioa.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
/q within three years, they should be pumped out and risers installed now.
U Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are ( ] or are aot [ ] wat�r tiQht or the condition is �) unknowa. I£ the tanks
are aot coafirmed to be watertiQht, this classificatioa is subject to revisioa.)
INFIELD CONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
CONII�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the
septic system is required by 12/31/2008.
����l v �-�-_
Date of Inspection tic System Inspector ,
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 � FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON–SITF SLWA(�E TREATI�NT
INSPECTION REPORT
ti
ti
'�' G
�9kEs8o�'�
Owner• �l/PI'1 �la�� Address:__�� �uP/.� �17i
Permit �'s: Z Datea: �CT�—N.7 Contractors: �L//)��
City ordinence nu�er 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is ,� an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into gro�d or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed accarding to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING STSTEM'�-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or mey not meet all the lxation, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distributia� device and the limiting soil characteristics.
(The limitin� soil characteristic�has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification mey be subject to revision.>
TANK CONDITION C5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumuletion in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> must be installed in each
tank at next punpout. If tanks have not been punned out within the last three years, they should be punped
OUL �10M.
1 inspection pipe is located directly over tank beffle (does not give accurate measurement of solids accunulation).
If tanks have not been punped out within the la�r rh�p�vears, the s ould be ut now.
�_
DRAINFIELO CONDITION (11-14):
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfietd extent and condition �known.
41MITING SITE fACTORS (sloae,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table.etc.): ���
COMMENTS:
Date o Inspection Se ic Sys em Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system wilt contirx�e to f�mction
properly� but is merely an opim on of the adequacy of the system under current conditions based on the available
tnformation.
This report must be kept on the premises with the system locetion and p�mping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowoer
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATI�NT
r�,, �C�, INSPECTION REPORT
'�� G~
9kESH.��'�
Owner: S�l/PY� E,UC'1JY)'7 Address:_��L��Yq//�Z.J �i'l�
Permit #�'s: Dates: �—/�� Contractors: Si���i1/or�
City ordinance number 100 requires that each on-site sewage treatment .system in Orono be •inspected on a regular basis.
The on-site sewage treatment system at the above address has been �nspected and appears to fall into the category
checked below.
(This is �J, an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
uithout discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM��-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 700-year floodplain; any
system which may or may not meet all the location, design, arxi construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting so�l characteristics.
(The limiting soil characteristic p�has or [ ] has not been identified at this ti�. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 5olids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible.
� System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e.
� Inspection risers missing-tanks could not be inspected. ns ctio risers 4'� dia. "
tank at next punpout. If tanks have not been ou uit in e as ree years, t ey should be
u.�t n +ow•
10 Inspection ptpe is located directly over tank baffle (does not give accurate measurement o so i s accunu atton .
If tanks have not been punped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
2 Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed uithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (sloae,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE Cdepends on soils.water table,etc.): ����
COMMENTS:�I�" j�-i" �' '' e � �
Date of Inspection ptic ystem nspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system tocetion and punping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner