HomeMy WebLinkAboutseptic info � O� _ _
O :. O
����� �-=- CITY of ORONO
3.
� �t��,�r�__�:. �,
�'`� ti
: � M�,;���t ot���
`\�� t `rl .N �
i'�0'�" G SVeet Address: qsa-a49—y6o 0 Mailing Address:
.�'��
��' �,r , 4 ,
�Hp 2750 Kelley Parkway P.O. Box 66
�� Orono, MN 55356 Crystal 8ay, MN 55323-0066
To Current Owner: Address: a��v �0^5v��`--- C:rL�t
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
The on-site sewage treah�►ent system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM":An ISTS which meets all the location,clesign and conshuction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An IST'S which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an i�inent tlueat to pubiic health or safety.
�`NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construcdon standards of the cua�t Orono Municipal Code and which is failing for any
reason;and any ISTS with less�an three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDIT'ION(5-7): �
Tank inspection indicates:
SO Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure seotir tanks are numued#hrou¢h manhole and not through white insaection aiaes. This allows for the arouer
cleanin�. Keea water softner and iron filter discharge out of seatic system to arolong life of drainfield. Ask numuer to test
alarm float to verifv alarm is still workinE in vour house. T6e alarm warns owner that septa¢e is about to backua into basemen�
7 Inspection risers missing-ta.nks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D IELD CONDTITON 8-10 : �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly dischazging untreated ei�luent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: U f R:i��,t\� iS c�u �- c��-�l;Rti�s- d- '(`�v1,�-- bC �'��!�uced
b-,+ �ti'3�-Zo�o
��Z-D -r�y �
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event thai this inspection report is used to satisfy the require�ents for a mortgage or otha transfer of property,be advised that tlus report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available information.
�°�
o.:� o . . .
,� ������� � CITY of �RONO �
�.��.�,�.
'�, ,,��• �.r .Munlcipal Of�ices
��'�i�.,� ; Og�i . Street Addross: MailinY Address: �
E8� , _ 2150 Ketley Parkway P.O. B
ax 66
- � - Orono� MN 55356 .� Crystal Bay, MN 55323-0066 .
. 95d-�4q-y600 � �
To G�ureat Owner. Address: a�5-� L��5 v ,�e� . .�:r�1�
City Ordinance 199 requires tliat each existing on-site sewage treatment system in Orono be inspected every two years.
The on•site sewage treatment system at the above address has been insp,ected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM"M ISTS whleh meeis all the locadon.daign and eonstrucdon standardc of the emm�t Orono Muaictpal Code.
2 "COMPLIANT SYSTEM" M IST'S which doa not meet all the location.daign and constivction standards of the aaent Orono Manicipal
Code but doa meet the thm foot separadon requinment or two foot cequlnment for systems installed 1996 or earlier.and which is not failing or
^"���aa Inunineat threat to public health or safery.
(3 rIVON-0011�LIANT SYSTEM" A prohibited ISTS:an ISTS located within a daignated I00-year tlood plain.any IS?S whIeh may. .
�J or may aot meet all the locatio�.daign.or construction standards of the cnaent Orono MunIcipal Code aad which is falliug for any reason;aad
any ISTS wi�h less than three feet of nnsaturated soit or sand between the d'uoributioa devia and the limiting soil eharacteristics.
TANK CONDTfION(�-:71: s �
Taak inspection indicates: � � .� . . . . .
� Pumpou►not needed at this time. �
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped t t-�'3-a� �. •
Make sure seotic tanks are oumoed through manhole and not through white insoect�on ulpes
This allows for the oroaer cleaning.
. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank:
FIELD CONDITION -IQ : �_
8 Drainfield'u dry,no surfacing evident
9 Some evidence of surfacing,aot cridcal ye� �
10 Drainfield'u saturated and visbly discharging untreated eftlueat to the surface. Contact the City Inspector � �
immediately.Repairs must be completed within 90 days. .
COb'IlVIENTS: Qe �:�C_;c\cJ �S �a�_ ��� 1.�..,- �.ne� �.�j �r Z !e I�.ce e/
� ---( �'L=�.,to �c� .
� ,-�-z-�� �1�.,� -
Date of Inspectioa Mau Boltera�an- Sepfic System Inspector
Note:!n the evrnt that thts inspection rcport is used w satisfy the rcquirements for a mortgage or otha transfu of property,be advised that this rcpoR doa not guarantee
or actity that an acisting system will con6aue ro funetion property,6ut is merety an opinion of tlie adequary o[the system undereurrent aondtdons based on the ava�'Iable
infomiation.
�o�
/
;, o; ,�,_ o
�! ��:=��=� CITY of ORONO
I� +���������T �
\ �' `�r�,��. l�r Munidpal Ofttces
\� �i �ti �
� �,✓.��?�..�I�.M.��� G�'
�, �������`� Street Addrou: Mailina Addrou:
��j�;g�HO�' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
July 7, 2000
Norman&MarS�Torrison
2250 Longview Circle
Long Lake, Mn 55356
Dear Mr. &Mrs. Tomson:
An inspection of your septic system was conducted on July 6, 2000. A summary of the inspection is
below.
Septic Tank Condition
i. Pumpout not needed at this time.
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City
Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic
system must be replaced by December 31,2010.
Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also
enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the appro�mate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
R ectful ,
- x�E�
's Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be
advised that this report does no guarantee or certify the esisting system will continue to function properly,but is
merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Faz(952)249-4616
www ci.ornno.mn.us
� � °�
�
0 0
�����-��� =- CITY of OliONO
,� ��tz���T��.-�r� �
f'b� �;:...�p�`d��:"'' �, Municipal Offices
�`�� ��1� r�'�'�`�4��' G�'
,� ��'Yt�,.:hl��.'
�;,���:r �� Street Address: Mailing Address:
�,9gEs�p��'% 2750 Kelley Parkway P.O. Box 66
��--�' Orono, MN 55356 Crystal Bay, MN 55323•0066 ,
To: The Current Owner of Address ol ��O L O�g tI��Q�
.
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The.onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall. .
Imminent Public Health Threat
Yes �
No �_
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identi�ed as Non-Compliant
Yes '�
No
If yes, system must be brought into compliance by:
December 31,2007 �
December 31,2010 �
Other '
Septic Tan�l�(�Pump out Needed
Yes ��
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every t ee e s. City records indicate the tank(s) were last pumped out on
l �'�� '� � . The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning.
Comments:
�.
Inspec���C/��''�'��'�+ ���:/`�' Date of Inspection ����
Telephone(952)249-4600 • Fax(9�2)249-461h
www_ci.orono.mn.us
� o�
. o 0
' ��� � T CITY of ORONO
� _ � - �
�
1,�� ;'�'';`''j��',�,i -�, �►
���'„� ��•;y.; ��: .�� �l�r Municipa! Offices
�.� �,�=i;;�,'eh�"�G SVeet Address: Mailing Address:
�'Egg04' 2?50 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
� � .
owner: �LL�'Yl)'1t��1 '01rir 1�O 1"� Address: 2250 Longviem Cir.
Permit #'s: 7406 Dates: 5/4/84 Contractors: Reith Clark
(This is [�( ] an existing system [ ] new construction) .
r-
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
(� Non-Compliant System: System may or may not meet current City standards for design,
v construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The ssturated soil level is [� or is not [ ] identified under this septic system. If the
saturated soil level ia not identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
$� Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
L•� have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [ ] or are not [ ] mater tight or the condition is [� unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 1.6 feet and the system is non-compliant. Repair or replacement of the septic
system is required by 12/31/2008.
/a- a- � 8
Date of Inspection i System ns ector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO �O�
Mimicipal Offices O O
Post Office eox 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATI�iT
INSPECTION REPORT
ti
ti
���k o4�G
�sx
Owner: l//[1l / � � 1�� Address: ��� L-qI"�t�u.�( ./7:'
Permit #'s: Dates: �� Contractors: �,P_�T��(� AY7C
City ordinance nuni�er 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction>
S STEM CONFORMITT 1-3 :
1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but Was installed according to the code in effect at the time of installetion, and which
is operating setisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the locetion, design, and construction standards of the current City
Cades and which is failing for any reason; and any system with less than 3 feet of unsatureted soil or sand
between the distribution device and the limiting soil characteristics.
(The limitin� soil characteristic �has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.>
TANK CONDITION (5-10):
Tank inspection indicates:
� Pu�out not needed at this time.
S ation in tanks indicates they should be is ear to hel prevent futur
o i s accunu a �on in " ' an s shou possi e.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next punpout. [f tanks have not been punped out within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
lf tanks have not been punped out within the last three years, they should be punped out now.
DRAINFIELD CONDITION C11-14):
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
Same evidence of surfacing, not critical yet.
13 Drainfield is saturated end visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Draintield extent and condition unknown.
LIMITING SITE fACTORS Csloce.setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table.etc.): ��
COMMENTS:
Date of Inspection Se ic Sys em Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
i nforn�at i on.
This report must be kept on the premises with the system locstion and punping records.
WHITE COPYllnspectors Flle YELLOW COPY/Homeowner
�°�
CITY OF ORONO O O
Municipal Offices
Post Office Box 66
Crystal eay, MN 55323-0066 a � ON—SITE SEWAQ�E TREATMENT
� �, IN3PECTION REPORT
ti
��9kEsH.o�'�G
Owner: /I.CX!'1�1l1h'� II'VMi.'Sr)I'\ Address: o�d`J� LD�Av1o�J �►/�
Permit �'s: Dates: �r�I��ST Contractors: ��� Ul��
City ordinance nunber 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(7his is 9(L an existing system [ ] new construction>
SYSTEM CONFORMITY (1-3):
1 "COOE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM'�-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standerds of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting so�l characteristics.
(The limiting soil characteristic -�}-has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection irxiicates:
Pumpout not needed at this time.
6 Solids accunulation in tanks indicates they should be pumped out this year to help prevent future problems.
Solids accunulation in tanks is at a critical level. 'fanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) �st be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be Fxmped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been punped out within the last three years, they should be punped out now.
DRAINFIELD CONDITION (17-74):
D field inspection indicates:
Drainfield is dry, no surfacing evident.
2 Same evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector
immediately. Repairs must be completed aithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE Cdepends on soils,water table,etc.): ��
COMMENTS:
ate of Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informat�on.
This report must be kept on the pre�nises with the system Locetion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner