Loading...
HomeMy WebLinkAboutseptic info ; , , • 1 • a. � To: Orono residents on mound type septic systems From: Willie Gibbs, ISTS Manager Date: May 10,2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent(the fiquid left after the"other" stuff has been removed) in the summer time and allows the mound system to help breakdown nitrogen in the effluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay oif of it. This is especially true in the winter time. Even human foot traffic can cause frost to penstrate the mound resulting in potential freezing problems. Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember,that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound system please feel free to call me, l can be reached at 952-249-4626. 1 ► � �..: .. �O_V � O O CITY OF ORONO � � Municipal Offices �, Street Address Mailiag Address: �� �j'�' 2750 Kelley Parkway P.O. Box 66 �i Orono,MN 55356 Crystal Bay,MN 55323-0066 9k'EsHo�' To: The Current Owner of Address 1490 LONG LAKE BLVD City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as N -Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump o Needed Yes No The city recommends the septic tank(s) and/or lift tank be serviced and umped out every three (3) yeaxs. City records indicate the tank(s)were last pumped out on � The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: ����"�"" �4.k� Inspector. Date of Inspection: �- O� Telephone (952) 249-4600 . Fax(952) 249-4616 www.ci.orono.ma.us �°� � o : o ��r:��,:��- _. CITY of ORON4 � , �� l�-k",„t; �r ��r :�>.,.- �F, MunicipalOffices � \� � � '��.,;-�;' ;�� G Street Address: q5a-a4q-�-160 0 Mailing#ddress: �,� �.r ;,� � �`9$E$Kp'4�' 2750 Kelley Parkway P.O. Box 66 �_____.—% Orono, MN 55356 Crystal Bay, MN 55323•0066 To Current Owner: Address: � �f�� �.���. G- L ra �e Z�� �a City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below. SYSTEM CONFORMITY (1-3): I 1 "CODE SYSTEM"An ISTS which meets all the location,design and construcrion standards of`the cu�rent Orono Municipat Code. 2 "COMPLIANT SYSTEM" An ISTS which does not mbet all the location,design and construction standards of the cuaent Orono Municipsl Code but doos meet the thrce foot separation nquirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an i�vinent threat to public heelth or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plaia,any ISTS which may or may not�et all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failiag for eny reason;and any ISTS with loss than thrce feet of unsaturated soil or sand between the distnbution dovice and the limitiag soil characterisdcs. TANK CONDTTION(5-7): �. Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic_tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure seatic tanks are aumaed throue6 manhole and not throu¢h white insnection aiaes. This sllows for the arooer cleanins Keea water sot�ner and iron filter discharee out of seotic svstem to nrolone life of drainfield. Ask aumper to test alarm float to verifv alarm is stilt workins in vour house. The alarm warns owner that seatase is about to backuu into basement 7 Inspection risers missing-tanks could not b�e inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be punnped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 9U days. COMMENTS: � � _ �,�" �C�}- i o � Date of Inspection Septic System Inspector i - . . . _ . . ,. i _ . .._ __. � O� O��. O _ �� --� �- CITY of ORONO �, �' � ' ,�ti M�� o� � �� � ,� *yG Street At�reu: _ Mailing Addreas: `��0�' 2150 Kelley Parkway P.O. Box 66 Ocono, MN 553�6 Cr�rstal Bay, MM! 55323�0066 -----_ _____ _____ _._. .----- - To�urnremt 4w�er: Address: � �g o L.o�g L-�kc, I v� � .., City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected�every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY 1-3 : � 1 "CODE SYSTEM"An ISTS which meets all the locaYion,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS w6ich dces not meet all�e location,design and conswction standards of the current Orono Municipal Code but dces meet the dvee foot separation requirement or two foot requirement for systeros installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet ail the location,design,or construction standazds of the current Orono Municipal Code and which is failing for any reason;end any ISTS witl►less than duee feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. (6 1 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 yeazs. � v Tank was last pumped ). Make sure seutic tanks are unmued through manhole and not throueh white inspection pipes This allows for the proaer cleaning. Keen water softner and iron filter discharge out of septic sv`stem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDIT'ION '8-10 : � Drainfield is dry,no surfacing evident. _ Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: /�^o v� 1 oo�C.s (�k_ �U�...� ScP fi;�- -�^�� Svh,cLc.� : �o o� . �'�-\'o� �"`°►� ��� Date of Inspection Matt Bo(terman - Septic System Inspector Note: In the event tl�at�is ias�ction report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this repork Qoes�ot guarsetee t�r oer�i'y�et aaeuiati�g�will continue to function propedy,but is merely an opinion of tl�e adeqwtcy ofthe system under current conditioes�Sad c��e�8il�le lielephone(952)249-4G00 • Faz(952)Z49-4616 � www ci.orono.mn.ns .���� ;�O O � _ - ���, , �r� ,.,- CITY o� ORONO � � � \, a , . , , _, ' =E � lC� Municipal Oft3ces '\� ! ��' ' r�,�.� ,y' � ' ' �'�� ' �� G Street Addross: MailinQ Address: ��' ��"i�,�;.,�°, . '�EggOg'� 2750 Keliey Pa�kway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 February 18, 2000 Troy& Catherine Anderson 1490 Long Lake Boulevard Long Lake, Mn 55356 Dear Mr. & Mrs. Anderson: The above described property is in a Metropolitan Urban Service Area (MUSA) for sanitary sewer installation. The factors for initiating the sewer project were smaller lot sizes and non- compliant septic systems with limited replacement sites available. The septic system serving your home is a compliant system according to State and City standards. Your property was exempted from connecting to the sanitary sewer system at that time. The existing septic system serving your home may stay in use until the system becomes non- compliant. If for any reason the septic system becomes non-compliant, the home must then connect to the sanitary sewer system If the home undergo's a remodeling project that will increases the total water use, the home must then connect to the sanitary sewer system. Minor maintenance can and should still be conducted on your septic system. Pumping the septic tanks, repairing or replacing pumps, and replacement of septic tank bat�les are examples of acceptable repairs. If the septic system needs major maintenance, such as septic tank replacement or drainfield replacement, connection to the sanitary sewer system will be required. If there are any questions regarding this letter, please contact me at (612) 249-4600. ectfull , , -�� ris Pence On-Site Systems Manager Telephone(612)249-4600 • Fax(612)249-4616 � °� . o :, o � ,,����-�y ,� CITY of ORONO � �k �` `� l4 Munici Oft3ces ���'��-;����:,!] ,y, Pal � �� ,,����-;`����G Street Address: Mailln�Addross: I-.rti!� `�'�*gg0g' 2750 Keiley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: � Address: 1490 Long Lake Blvd. Permit #'s: 618 Dates: 10/14/93 Contractors: Ritter Exc. (This is [�j an existing system [ ] new construction) . STEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [�] or is not [ ] identified under this septic system. If the saturated soil level ia not ide'�itified, this claasification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. Zf tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks ara [�] or are not [ ] water tight or the condition ia [ ] unknovrn. If the tanks are not confirm�d !.o be xatertiqht, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low CONII�IENTS:The residence must be connected to municipal sewer by 12/31/98. g�7�Date o�nsp ction c System In ec or Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO Date ADDRESS � Connected to CODE SEPTIC SYSTEM IN,V$ ORY CARD Municipa1Sawe�,_ Address G-CY✓E: �LVA. oper .D. � -�� 3 d�`j� { WELL i ATA �Standard trench GoTS ,� ,AL13 L� i4�P• � I ❑ Mound . N/t.{F'fA'T' . � System type ❑ Other Legal scripti•n � � d t Permit No. � Date of per � Installer � O . Bedr ms ���'arbage � d I � ` - Building type � N or GPD - undry Di sh r Disposal � •- E n 0 SEPTIC TANKS: Material g ��' Capacity-1) 1✓ ° oC � � ' �' ,� 'o � . d � Proper outlet and' let Baffles ,-�"" Liq depth to O level s -'� + � � ` := o �- i � Height of tank bo ter t le + Dis ce ne rest ilding S m N p DRAINFIELD: Total length f lines mber of lin �- �- Trench width � 1 Y �Total treatment area (s .) ' t o rai ield abov water table � '} � �� U Type of filter material Soil ty e a ^� N d � E t w Distance from nearest bldg. S '� Ti si � Perc rate min/in ° � d ,c p 'o . +••� U �'' f0 Depth of fill over drainfield Dept f rock over tile under tile � a �, " E c � p a V � /� � �'�� ��Yp � / LOCATION INSPECTION RECORD PUMPOUT RECORD / / SKETCH DATE COMPLIANCE DATE GALLONS ' � i . i 7�z�C No s,.�,�F�cr.vG Nor�D � /n_30-7� o�� � � I i � `?— l�s a � �� .C�e Sie.f'F/�i�%c Noi�O z 12�.2_—Q> � � ��I � � I —�' �,_.� N�S�.�kF-��c��vt, � 7/-9,� 15d0 i ► d� � � � � /�� � „ _� � � � , "63 ��i' I I I � � - I i i � � i Yr�1��� - ' ; � � �,� � I � I ��- '�°��� � - � ' i ; �n I�n�� Sy�'-r � � f� Cl►"'• I Ihclude: 1) Well locati n — � � 2) Distance fr m house to � � septic tank ,dist.box, and drainfi Id � � C— CONFORMING S —SUBSTANDARD N — NONCONFORMING I I 3) North arrow and road � I I � CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON-SITF SEWA(;E TRPDATISSI�iT ° INSPECTION REPORT ti ti '�' G �9kEsao�'� Owner. Trav A�,-,�„�� Address• LJ Permit #�'s: Dates: 1[/-�7�J� Contractors: lCl eY- ,r'llC-i� City ordinance number 100 re�ires that each on-site sewage treatment system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the cetegory checked below. (This is �an existing system [ ] new construction) SY TEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONF�MING SYSTEM"-A system uhich does not meet all the locati�, design, ar�d construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, end �ich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-0011FORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodptain; any system which mey or may not meet all the location, design, and construction standerds of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The timiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.> TANK COHDITION (5-10): � 7pr� inspection indicates: (� Pumpout not needed at this time. Solids accunutation in tanks indicates they should be pnped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Yanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids accunulation>. If tanks have not been pu�out within the last three years, they should be punped out now. DRAINFIELD CONDiTION (77-14): Dr ield inspection indicates: Drainfield is dry, no surfacing evident. 1 Same evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repeirs must be completed within 90 days. 14 Drainfield extent and condition unkno►m. LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table,etc.): � COMMENTS: � Date of nspection e c Syste inspector Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function propertyi but is merely an opim on of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system locetion and punping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E T.REATMENT INSPECTION REPORT ti ti ��9k o4�p �sH. Owner• l Address• �F-� . Permit #'s: �7�/R Dates: /(7�'-f�-� Contractors: City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is [ ] an existing system �new construction) SYSTEM CONFatMITY 1-3 : 1 "COOE STSTEM"-A system which meets all the Location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONfORMiNG SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into gro�d or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; eny system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (7he limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tpr�k inspection indicates: cy Puipout not needed at this time. 6 Solids accumulation in tanks indicates they should be cxnped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. 1'anks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 lnspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed in each tank at next purtipout. 1t tanks have not been p��npr.�d out within the last three years, they should be pu�ed out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been puqx�d out within the last three years, they should be puiped out now. DRAINFIELD CONDlTION C11-14): Dr field inspection indicates: �Orainfield is dry, no surfacing evident. �L Sane evidence of surfacing, not critical yet. 13 Drainfield is seturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloce,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): 1�,1� COMMENTS: Date of inspection S p System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or cert�fy that an existing system will continue to function properly� but is merely en opim on of the adequacy of the system under current conditions besed on the available information. This report must be kept on the premises with the system locstion and punping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner 14�0 Long Lake Boulevard Orono, Mi.nnesota 55356 January 9, 1993 Stephen Weclanan Ck�-Site Systems Manager 2750 Kelley Par',tway P.O. Box 66 Crystal Bay, Minnesota 55323 Dear Mr. WeClanan, This serves as a letter of intent stating that, should the existing septic system at 1490 Long Lake Boulevard, Orono, require replacement, we will do so when weather and ground conciitions permi.t. Should this be the case, a suitable site has been located on the property by S & P Testing, St. Michael, Minnesota. ncerel Tr D. Anderson CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON–SITE SEWA(�LR TREATMI:NT � � INSPECTION REPORT ti ��9k'Es8o4'�G Owner• �� fh /f'� Address• Permit �'s:�'101►1e, Dates: � Contractors: '— City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been tnspected and appears to fall into the category checked below. (This is�1. an existing system [ ] new construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input ry without discharging any pollutants into ground or surface waters. �J "CONfORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfectorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONPORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; .and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or� has not been identified at this time. If the limiting soil characteristic has not been identified, this lassification may be subject to revision.) TANK CONDiTION (5-10): T$q�c inspection indicates: (� Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be p�ped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each tank at next pumpout. [f tanks have not been pumped out within the last three years, they should be punped out now. 10 inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been p�mped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (11-14): D nfield inspection indicates: 1� Drainfield is dry, no surfacing evident. 'f2 Some evidence of surtacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 74 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAiLURE Cdeoends on soils.water table,etc.): '�� COMMENTS: Date o Inspection ptic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available �nformation. This report must be kept on the premises with the system locetion and purtiping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner