Loading...
HomeMy WebLinkAboutseptic info �� °�� 0 0` :::::�:;�:::.r _ cITY of UItONa ���'�r�7 °� � ,�, r����� a��<, ,': \�� t,��;,�-(�- ,�r�r =��' ��, Municipal Offices 1��1,�'�`�'7',SP..J);�'• ``��';��'��{��`'��,�� G Street Address: Mailing Addresr. � r '�(,.��,a"�5,4,. �R �' "r �p4��i 2150 Kelley Parkway P.O. Box 66 �� kESK Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Current Owner of Address � �� �� �Q J�'� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The.onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes,please conta.ct the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 da.ys. Failure to do so will result in referral to the City Attomey for legal action. System Ident' as Non-Compliant Yes No If yes, system must be broug ' to compliance by: . December 31,2007 December 31, 2010 Other � Septic Tank(s)Pump out Needed Yes � No —� The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the ta.nk(s)were last pumped out on �- r �, �- c��1 . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: � ���Ck� C�J . � �O ro Inspector: Date of Inspection Telephone(9�2)249-4600 • Fax (95?)249-461b wr��w.ci.orono.mn.us � o.�,. _ 0 0 � ��� �-_� CITY of ORONO �r�3�. ,j° >--� p,r ;� `�l�' �� " ��, Municipal Offices ,�' :�:.,`�_ � ;� '� �`�"""� �r G Street Address: °ISa.—a49—y6o O Mailing Addreu: ,; r ; � ,� �`9�'���p'4�' 2750 Kelley Parkway P.O. Box 66 �_ Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: I�6s LSkC V:�ti... ��f Cu.C� City Ordinance 199 requires that each e�cisting on-site sewage treaixnent system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SI'STEM"An LSTS which meets all thelocation,design and construction standards of the cwrent Orono ivSunicipal Code. 2 "COMPLIANT SYSTEM" An ISTS which dces not�et all the location,design and constr�ction standazds of the current Orono Muaicipal Code but does meet the three foot separation requir�ent or two foot requirzment for systems installed 1996 or earlier,and which is not�iling or an i�inent tl�reat to public health or safety. � "NON-COMPLIANT SYSTEM" A prolubited ISTS;an TSTS located within a�signated 100-year flood plain,any LSTS wlrich may or may not�et all the location,design,or construcdon standards of the ciurent Orono Municipal Code and which is failing for any reason;and any LSTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITTON(5-71: S� Tank inspection indica.tes: �Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped a-\`"0''1 ). Make sure seatic tanks are uumaed throueh man6ole and not throu¢h white inscection aiaes. This allows for the nrouer cieaning Keea water softner and iron filter discharse out of seatic svstem to arolon¢life of drainfield. Ask numaer to test alarm float to verifv alarm is still workine in vour house. The alarm warns owner that septaee is about to backua into basement� 7 inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. IELD CONDITTON 8-10 : �, 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield.is satiu-axed and visibly discharging untreated ef�luent to the surface. Contact the City Inspector immediately.Repairs must be completed within 9U days. COMMENTS: �:.c��.�\�� :4 5�a�.- C o N- �;Gr�- 3`�vS�.- �L (' C,o �.��c.a-t. c� S ewc r �t 31-Zo d , �-\�- by C�� Date of Inspection Matt Bolterman- Sepric System Inspector Note: In the ev�t that this inspection report is used to satisfy the requirements for a mortgage or other transfer of properry,be advised that this report dces not guarantse or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. �o�. o .� o ������ CITY of ORONO `.�� � '����� ��� ,� Nt��� ot�t� � .`t G . ��y�f�� Street Addross: Mailin Add EgK04'� 2150 Keiley Padcway P.OgBox 66�� Orono, MN 55356 Crystal Bay� MN 55323-0066 95d-�4q-4600 To Current Owner: Address: � �6 S ��- �:e�..- TeC����- Ciry Ordinance 199 requ'ves tliat each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"M ISTS which mats all the location,design and construction standards of the current Orono Munictpal Code. 2 "COMPLIANT SYST'EM" An ISTS which does not meet all the location,daign and construcdon standazds of the cucnnt Orono Municipal Code but does meet the three foot uparation requinment or two foot cequuement for systems instalied 1996 0�earlier.and which is aot failing or an imminent threac w pnblic health or safety. 3 "NON-COMPLIAN'T SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any 1STS which may or may not meet all the location.design,or conswction standards of t�e cucrent Orono Municipal Code and which is failing for any rcason;and any ISTS with tess than tluee feet of unsaturated soil or sand between the d'utribution device and the limitine soil characterisdcs. TANK CONDITION(_.5-:7�: � Tank inspection indicates: � Pumpout not needed at this time. ' "(6 �Septic tanks must be pumped out this y�ear (city code requires tanks to be pumped out once every 3 years. v Tanlc was last pumped �6- �X ) Make sure seatic tanks are numaed through manhole and not through white insaection aioes. T61s allows for the uroaer cleaninQ. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. INFIELD CONDITION �C� : 8 ninfield is dry,no surfacing evident. Some evidence of surfacing,not critical yet. � . 10 Drainfield is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: S S Ye.� � c�a _ o r. 1;��'� R�YI �� � to n�.c c..r l/ � �. � � Z,=�1 -Z.�d7- .� �.K. :.4- -Y►.c �av �0'r ►�ic� J �^--•} . . � � ,��- o� ��c Date of Inspecdon Matt Bolterman- Septic System Inspector Notr. In the event that this inspection rcport is uxd to satisfy the rcquirements for a mortgage or other transfer of property.be advised that this rcpoR does not guaranue o�artify Ihat an existing system will continue to tunction properly,but is mercly an opinion of the adequary of the system under cucrent conditions bated on the avai�abk infortnation. �°� . 0 0 � � CITY of ORONO �,,,� ,L'�A'°r�,�'�`.,--� i5r Municipal Offices \�� 0.*1,� �IL� 1� � . ,� ��� � �,,��"��',�G Street Addross: MailinQ Addross: '��KQ'g' 2750 Kelley Parkway P.O. Box 66 February 18, 2000 Orono, MN 55356 Crystal Bay, MN 55323-0066 Karl&Sherrilyn Aske 1865 Lakeview Tenace Long Lake, Mn 55356 Dear Mr. &Mrs. Aske: The above described property is in a Metropolitan Urban Service Area(MUSA)for sanitary sewer installation. The factors for initiating the sewer project were smaller lot sizes and non-compliant septic systems with limited replacement sites available. The residence was required to connect to the sewer system no later than February 14, 2000. Recently, the City Couiicil adopted a resolution allowing all sewer connections to coincide with the septic system upgrade time frame. The time frame for a septic system upgrade is seven to ten years from the inspection date dependant upon the property's location. Your property will nced to connect to the sanitary sewer system no later than December 31, 2002, wl�ich is the date your septic system was to be upgraded. A Sewer Availability Charge (SAC)fee will need to be paid to the City in the year the sewer connection is made. A licensed plumber must then obtain a permit from the City to make the connection from the residence to the actual sewer line. If at any time before December 31, 2008 the residence undergo's a remodeling project that will increase the total water use, the residence must then connect to the sanitary sewer system. If at any time before the above date the system is failing,the residence must then immediately connect to the sanitary se�ver system. Minor maintenance can and should still be conducted on your septic system. Pumping tlie septic tanks, repairing or replacing pumps, and replacement of septic tank baffles aze examples of accepta.ble repairs. If the septic system needs major maintenance, such as septic tank replacement or drainfield replacement, connection to the sanitary sewer system�vill be required. If there are any questions regarding this letter, please contact me at(612) 249-4600. R ctfully, � Chris Pence On-Site Systems Manager Telephone(612)249-4600 • Fax(612)249-4616 ::%�"�o� ,, � � . ,;�o o , � � � � �'��'�� CITY of ORONO ;l���� �-- � �i � � ,,�_ ; , ,�:-� �ti�/ Municipal Offices ,�,�9 � � f �`��4.�G � Street Add�ess: Mailin� Address: , �CEggO 2750 Kelley Parkway P.O. Box 66 �� Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: ��e. Address: 1865 Lakeview Terrace Permit #'s: 1607 Dates: 8/29/67 Contractors: Bob's Plbg. & Htg. (This is [x an existing system ( ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [� ] or is not [ ] identified under this septic system. If the saturated soil level is not id�ntified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is [X� unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) D INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to public health or safety (surface discharge or backup into the dwelling) . The residence must be connected to municipal sewer by 12/31/1998. �� L� Date of Inspection S p ic Syst m Inspecto Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO �O� M�icipel Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(;E TREATl�Ml' �ti INSPECTION REPORT ��9k o4�p EBH Owner• �Address•_ _i��� �1��=K.1'/l��irQ� . / Permit #`'s: Dates: �����Contractors: City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �l,an existing system [ ] neW construction) SYSTEM CONFatMITY (1-3): � t "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input witha�t discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING STSTEM'�-A prohibited system; a system located within a designated 100-year floodplein; any system which may or mey not meet all the location, design,.and construction standards of the current City Codes and which is faili for any reason; ,and eny.system with less tha 3 feet of unsaturated soil or sand v� betw ' ' ' the limitin . (The limitin� soil characteristic as or [ ] has not been identifi at i� ti f � e l ting soil characteristic has not been identi ied, this classification may be subject revision. TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be wmr�ed out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Yanks should be {xanped out as soon as possible. 8 System is discharging to the surface. Tanks must be pu�ed out within 48 hours to eliminate surface dischar4e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next p�mpout. If tanks have not been punped art within the last three years, they should be Fxmped out now. 1 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). lf tanks have not been punped out within the last three years y hould out now. � DRAINFIELD CONDITION C11-14): field inspection indicates: 11 Drainfield is dry, no surtacing evident. Same evidence of surfacing, not criticel yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS (slooe.setbecks.etc.): POTENTIAL FOR SYSTEM FAILURE (deoends on soils,water tab4e.etc.): � CO NT • � l � � Date o Inspection Se i ystem Inspec or Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system uill continue to f�mction properly� but is merely an opinion of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the premises with the system locetion and Fxmping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal eay, MN 55323-0066 a � ON—SITE SEWA(�E TREATl�NT � �, INSPECTION REPORT ti '�' G �9kESHo4� Owner: �Y' r'i�l�+� Address: �/�� �KP1/I%!� /�J�Y/ICP. Permit ,�'s: Dates: t5�'�--�� Contractors: ,LY�rQ� �l.d�. City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is .�an existing system [ ] new construction) SYSTEM CONFORMITY (t-3): 1 �'CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discherging any pollutants into ground or surface waters. "CONFORMING SVSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but Was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or may not meet all the location, design, end construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin$ soil characteristic [ ] has or � has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION CS-10): Tank inspection indicates: � Puipout not needed at this time. Solid eccunu ' ' ' ' ates th ' t v , �7 o i s accunu ation in tanks is at critical level. an s should be out as soon as possib e. 8 System is discharging to the surface. Tanks must be p�mped out within 48 hours to eliminate surface dischar$e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been pun�ed out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been punpea out within the last three years, they shoutd be punped out now. DRAINFIELD CONDITIOM (11-14): Dr field ,inspection indicates: Drainfield is dry, no surfacing evident. �Sane evidence of surfacing, not �atical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repeirs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS (slooe.setbecks.etc.): POTENTIAL FOR SYSTEM fAILURE (decends on soils.water table.etc J: �p�ri�,�,�, COMMENTS: Date of Inspection S pt System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to f�ction properly� but is merely an opinion of the adequacy ot the system under current conditions based on the available informat�on. This report must be kept on the premises with the system locetion and pumping records. WHITE COPYllnspectors Flle YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAQ�E TREATI�NT r�, � INSPECTION REPORT '�� G~ �kEsxo�'� Owner: 1�7h/ ft5� Address: lg� LA,�,�,��� T,�r. Permit �'s: ���7 Dates: ga�—�7 Contractors: �S 1'/�. City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is fi11, an existing system [ l new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants �nto ground or surface Waters. 3 "NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any_system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or�has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): � T�q(c inspection indicates: (y Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. 7 5olids accumulation in tanks is at a critical level. `fanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pu�ed out uithin 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each tank at next p�mpout. If tanks have not been pumped out within the last three years, they should be punped out now. 10 lnspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (11-14): Dpe�9�field inspection indicates: �1Y Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE fACTORS (slooe,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table,etc.): �.�,J�,y� l( COMMENTS: Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or cert�fy that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available information. � This report must be kept on the premises with the system locstion and pu�ing records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER .�� �'L�,�'P- ADDRESS !o����P`✓l".��L,��'✓�'G PERMIT NO.'S. ��7 DATES �%�9'?�7 CONTRACTORS �S ��� City O►dinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall i�to the category checked below. (This is �l an existing system ❑ new conatruction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Dces not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,co�struction or location,but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION (m Checked items may require your actio�) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not � Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation i� tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfaci�g evident. ❑ System is discharging to surface. Tanks must be pumped Some evide�ce of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield ia saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia.pipe)must be installed in each ta�k ment or additions to d�ai�field. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they ahould be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil tabl,e..�t and system conditio�) �Adequate ❑ High water table 1�Low ❑ Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: /��/d Date of Inspection ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to functio�properly,but is merely an opinion of the adequacy of the system under current co�ditions based on the available information. This report must be kept on the premises with system location a�d pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of� Lakc�Yfin7aetoyzka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 owNER �d:�.�"t- �c(.�►-svr� aooREss I��� (-�l�v��,�� Te�z.ce, l�mG���lo, � PERMIT NO.'S. ��Q � DATES � �'� CONTRACTORS ���� 'S ��'�C�'Y��i✓�� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the b�address has been inspected and appears to fall into the category checked below. (This is n existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. -�I�,f 7 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, 4 located, and constructed enerall in accordance with revious codes.System a g y � p ppears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high pote�tial for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. if drainfield replacement is necessary, soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: Inspection pipe is located directly over tank baffle. (Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks D ain "eld inspection indicates: should be pumped out as soon as possible. �,Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTER�STICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Fu�Expansion ❑ Soil table nd system condition) dequate ❑ High water table �Low ❑ Fair ❑ Lot size ❑ Medium � Poor �Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: % / �� � 22 �B �-- � . Date of Inspection Septic Syste spector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY!Homeowner On the North Shore o f Lake�Ylinnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER /1�4'!�L �`1"_S�C ADDRESS / �Cc%—`� L ��L`��/G����lk71 i7"C � � PERMIT NO.'S. ���, � DATES g � `'��� � � �?— CONTRACTORS �G�S �� 6�' City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above ad ress has bee�inspected and appears to fall into the category checked below. (This is an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accorda�ce with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, constructio� or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replaceme�t is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started.- SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ---r� Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped �� Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers l4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion _—�7 Soil table,and system condition) ❑ Adequate �� High water table ❑ Low ❑ Fair —� Lot size ❑ Medium --� Poor --E7 Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ---�1 System is causing visible surface discharge. COMMENTS: �/���/U F�LI� /� �OFT ��C-'JVG L/��/�� �ENU T� , � i�'��NS�'�ZT /�t,' �d v-4�-s, -S� /� � Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. � Crystal Bay, MN 55323 • - • � 473-7357 OWNER �ARL AS�CL� ADDRESS � �&5 LfIK�Y/CW ��P.�CRFC '— PHONE PERMIT NO'S. d�D� DATES �'�a�-b7 City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ❑ � Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. � � Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. ❑ � Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ � Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: � Septic tanks must be pumped within 48 hours. � Drainfield must be repaired or replaced within 90 days. � Inspsction riser (4"diam. pipe) must be installed in each tank. � Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑Slope (depends on soil types, water Future Expansion ❑Soil table,and system condition) � Adequate �-ligh water table ❑ Low [�. Fair ❑Lot size (�„Medium ❑ Poor �Lake,wetland,or stream (p�High ❑ Inadequate �Drainage �System is causing visible surface discharge. COMMENTS: (�-��-Ky � v,,� Date of Inspection S tic System Inspector This report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY/Homeowner