Loading...
HomeMy WebLinkAboutseptic info - - SEPTIC SYSTEM INVENTOR Y � Address: 3175 Jamestown Rd. PID: 28-118-23 33 0004 Building Typeresidence BRs Install'd for: 3 In Musa: Yes Permit#: 5548 Date of Permit: 5/8/79 Installer: Gene Hayes System Type: standard trench Performance: no Tank Filter: SYSTEM CONDITION Conformity: 3 Tank Condition: 9 DF condition: 8 Failure Pot: medium SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Setback to Bldg: 9 Cesspool: no DRAINFIELD Length of Lines: 325 # Lines: 3 Trench Width: 3 Treatment Area: 975 Type of Filter: rock Soil Boring: yes Tile Size: 4 Under Tile: 12 Perc Rate: 30 Setback DF-Bldg: 30 DF Ht above Wt: 0 Soil Type: loam, clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 80 Report in File yes Pump Type: subm. Depth: 220 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 5/14/79 installation c 10/2/86 1000 7/17/84 no surfacing 1 8/13/90 1500 12/15/86 no surfacing 1 5/15/87 no surfacing 1 9/19/91 no surfacing 1 10/11/93 non-conforming-repair by 12/31/95 3 7/15/96 non-conforming-repair by 12/31/96,pum�3 9/22/99 non-conforming-repair by 12/31/03 3 8/13/O1 non-compliant,replace by 12/31/2007 3 8/20/03 non-compliant,replace by 12/31/2007 non-compliant 5-�2�) .c14� 1����t,� -r An t�S ,. , , - f �� 5���� � � � � i .�� � ��-�� ��1. � � � �r� o �g � � 0 - A �t�''z�r' I � U� � � � �n �� <'�S � �;� �� �� aa� �. a� ��I� �q'� l��� ��'� � �� � a �n� ��� �� � � � � -- o�- � a I''� � � � ��� �� 6 ��, , ��� -- ��� � d � ��' ' O : O ' ��.�M�:,�:- � ciTY of oRONo Y'i � ,r��;,f�,-: _ �► � � � '" ��, , . Municipal Offices 4 t:'t ,�'�►� ,� ,�:.�� G qsa-a49-y6o o g � ��;:-:� .��`' Street Address: Mailin Address: \:�'��`����p'�'�// � 2150 Kelley Parkway P.O. Box 66 �ESII�� Orono, MN 55356 Crystal Bay, MN 55323 0066 To Current Owner: Address: � � A✓� S � City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment syste at the above address has been inspected and appears to fall into the categories checked belo . SYSTEM CONFORNIITY 1- : � 1 "CODE SYSTEM"An LST which meets all the locadon,design and construcdon standards of the current Orono Municipnl Code. 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the locadon,design and conshucdon stanc�rds of the current Orono Municipal Code but does meet tt�e three foot separation requirement or two foot requuement for systems installed 1996 or earlier,and which is not i'ailing or an imminbnt threat to public health or safety. 3 "NON-COMPLIANT SYS'�'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,jdesign,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than tlirce feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-'7): � Tank inspection indicates: � 5 Pumpout not needed at this�time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 yeazs. Tank was last pumped Make sure se tic tanks are um ed t rou 6 manhole and not throu h white ins ection i es. T6is allows for the ro er cleanin . Kee water softner a d iron filter discha e out of se tic s stem to rolon life of drainfield. Ask um er to test alarm float to veri alarm is still workin in our 6ouse. The alarm warns owner that se ta e is about to backu into basemen 7 Inspection risers missing- could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITTON f8t101: � 8 Drainfield is dry,no surfa�ing evident. 9 Some evidence of surfacin�;,not critical yet. 10 Drainfield is saturated andI visibly discharging untreated effluent to the surface. Contact the City Inspector , immediately.Repairs must be completed within 9U days. COMMENTS: � � I �i� r� �j�-- . S LI _ S � � � — il r'I�t v i 8Q i -�7. i ��f -c� S� C-�.�' �r Date of Inspection Septic System Inspector Note: In the event that this inspection port is used to satisfy the requirements for a mortgage or other transfer of properry,be advised that this eport does not euarantee or certify that an existin system will continue to function properly, but is merely an opinion of the adequacy of the system u der current o � � � � o;::�. . �:��:�:�_:. � I CITY of ORONO �y�,�, � � �� �-�.`� 'a � , �;_ Municipal Offices , � �� �� � �� U��������:�� ,� Street Address: Mailing Addross: ' 'ql�'E$HQg' 2150 Kelley Parkway P.O. Boz 66 Orono, MN 55356 Crystal Bay, MN 5 323•0066 To Current Owr�er: Address: 3 f �� ��Mes fio�� R U City Ordinance 199 requires ttuat each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment stem at the above address has been inspected and appeazs to fall into the categories chec ed below. SYSTEM CONFORMIT'�(1-3): � 1 "CODE SYSTEM" �STS which meets atl the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYS M" An ISTS which does not meet atl the location,design and construction standards of the current Orono unicipal Code but does meet thd three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is n t failing or /^� an imminent threat to p�ublic health or safery. ( 3 � "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located witl�in a designated 100-yaar flood plain,any ISTS which ay `J or may not meet all tho location,design,or construction standards of the current Orono Municipal Code and which is fai(ing for any r�eason;and any ISTS with less thah three feet of unsaturated soil or sand betwoen the distribution device and the timiting soil characteristics. TANK CONDITION(5-71:j � Tank inspection indicates: ' 5 Pumpout not needed a�this time. � Septic tanks must be p�niped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumpec� �S�\'�—"�� ). Make sure septic tanlcs a�e pumped through manhole and not throu¢h white insnection aines. This allows for the proaer cleanin�. Keen water softner and iron filter discharge out of septic system. 7 Inspection risers mis�ing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been piimped out within the last three years,they should be pumped out now. DRAINFIELD CONDITIO 8-10 : � 8 Drainfield is dry,no facing evident. 9 Some evidence of sur�acing,not critical yet. 10 Drainfield is saturate�and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repair must be completed within 90 days. co�rrrs: �r� �•_��� ; o _�Q f_ �;��� � n,�s�- be. �e iq��J � =�\=�--ud7 . - L �� � ��- �'►,Q l..o.v b ce�. v r e w- ��'+— 5� �r S , � -Zp -o�'' �� 6�� � Date of Inspection I Matt Bolterman- Septic System Inspector Note: In the event that this inspection epart is used to satisfy the requiroments for a mortgage or other transfer of property,be advised that this report do s not guarantee or certify that an existing system will c�ntinue to funcUon properly,but is menly an opinion ofthe adequacy of the system under current conditions based n the available informaGon. Telephone(952)249-4600 • Fax(952)249-4616 �, www.ci.orono.mn.ns ill . O � � O � O ���-� CITY of ORONO ,���� ,� . � ��: 4� „yti MtmIc�pal OtRces � ' G . �Streat Addrou: , . O4� , 2150 Kelley Parkway Y p p�g� �� � � Orono, MN 55356 � Gystai Bay, MN 55�23-0066 Owner: M�c.1, e\ vi S�� Address: 3 I 5 �g M S t ow� cJ City Ordinance 199 requires that�h existing on-site sewage treatment system in Orono be inspected e�rery two yeazs, The on-site sewage treatment syste�at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORNIII'Y (1-81: 3 " 1 "CODE SYSTEM" Aa LSTsiwhich mxts a11 the tocation,daigi and construction standards ofthe aureat Oraao Mnoicipal Code. 2 "COMPLIAIVT SYSTEM"''An LSTS which does not moet a!1 the tocatioq deaign aad coa�uction standacds of the aiaart Oroao Mnaicipa! �� Code but does meet the three f separatton requiremau,aad which it not failing oc an immiae�threat to public heahh a�safdy. : (3 ) "NON-COMPLIANT SY�$�"..Aprolu3ded ISTS;aa LSTS located withia a designated!0o-yeac Hood plaio.saY ISTS which may �� or may mt med all the locati desigq or coastcuctioa atandardi of the cument Orouo Muaicipal Code and wluch is for an ��8 Y�:and aay ISTS with less thaa thr«�of uosaL�rated soil or saad becwaa the distnbutioa device and the limitin.g soil chacada�istia. . . TANK CONDTI'ION(5-101:� ,� � � Tank inspection indicates: I • � i 5 Pumpoas not n«aea at this time. '' I 6 Tank must be pumped out this Yea� (city code taNira tanks to be pumped out evay 3 yeais. Tank wa4lavt pumped �-I 3-9 U ) '� 7O Solids accveaulatioa in tanks it at�aitical a ccitical IeveL Tanka should be pumped out as soon av poasib(e. 8 System is disd�argfng to the stufa4e. Tanks awst be pumped out within 48 ho�us to elimiaata siuface diacharge. 9 Lupectioa iisas missing-taoks crn►Id not be in4pected, Itsspection risas(4"dia.Pipe)must be installed ia each taak at ne�pumpout, If taoks have aot ban pumped out witLin 1he lasc thcee Yeats,they sbould be pwnped out now. 10 Lupection pipe is located diredly pver tanlc tiaffle(does not give aavrate measurem«rt of wlida aavmulation). 1f tanks have nat ban pumped out within the last three Yeais,thex should ba pumped out now. , DRAII�iFIELD CONDTTION(11�14): �� 11 Dralnfield is dry,�surfacing evid�t . 12 Some evidenoe of siufacing,nat ait�cal yet . , . 13 nraioGda is a�aua ana viubly e�ch�,i,s,�reatea�mue�to the wrface. eontace the ear��ly.Repaics musc be oompleted within 90 days. � � • , . 14 Drainfie(d e#ent aad conditioa ewn. • � � CONi11��NTS: 5 fien. "�S � �o�- �o�,,, 1;a��- d�e. to l�c.k o� 3 �roo s e�q :o� bct�ec� bor�u�•-, o� -rce� � ok Se�so�� r.�a�e�+q6k , Re \qce. b �a-3i-aoo�. ��... tan�s�. � �i -13 �d t � �Y�o�t. n�oe tioa � • - . �� Sep6c System inspector Note: Ia the evart that thu inapection rePoct is�to�atis�'Y t��Niraneats fa s moctgage or othc traa�'a of proPertY.be advised tbsd this repod doa nart or certity that aa e�dsting aystem will coatinue fundioa ProP�Y,but is maety aa opinioa of the adequuy of the sy�tem uoda cuaa�oondtioas based on the vailable infocmatioa. -O � CITY OF ORONO � � Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r$)� h INSPECTION REPORT ti ��9kESH�4'�G Owner:��I��-��/r��� ��`�C �J Addres s: ����� �J l,¢1����lc4Ll /C�7' 1��3�E�� C/' �"' CJ � .% Permit �'s: �1.7� Dates: ✓ —�" �/ Contractors: /7��/C=�S City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is�an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging �, any pollutants into ground or surface Waters. 3 "NON-CONfORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system Which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith tess than 3 feet of unsaturated soil or sand betueen the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): �}' f Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumPed out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 7anks should be pumped out as soon as possible. � System is discharging to the surface. 7anks must be pumped out uithin 48 hours to eliminate surface discharge. [nspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. If tanks have not been punped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): �field inspection indicates: 11 Drainfie[d is dry, no surfacing evident. Some evidence of surfacing, not cr�tical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS (slope,setbacks,etc.): � �t}� � POTEN7IAL FOR SYSTEM fAILURE (depends on soils,uater table,etc.): �.��.����1LYI COMMENTS: `.7 �� S G'Yl ��OYl7L'r st/� �� GC (C!�C< � �ll 1'�t? 7TJl�� .�{' Gl�cJ 7�/d !� trt �E'c/ , S• Q1�-l4 � — )3• Date of Inspection eptic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certtfy that an existing system uill continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system loc=_tion and pumping records. WHITE COPY/lnspectors File YELLOW COPY/Homeowner � o.�;.�,, � ,,o o ��. :, r �j,, CITY of ORONO � . � . r� ���, ,� i�� �l�, - Municipal Offices ���� � �� � �%�� Street Address: Mailing Address: ` �9 �,'� �� k'EggO % 2750 Kelley Parkway P.O. Box 66 � �- � � Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: �C.���l{'J ' ��1./�C/� Address:3175 Jamestown Rd. Permit #' s: Dates: Contractors: (This is f„�,, an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 3 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance ,� with previous codes and is functioning properly. / 3 � Non-Compliant Svstem: System may or may not meet current City standards for design, L� construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [ ] has or [ ] has not been identified at this time. If the saturated soil level has n t been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been � pumped out within three years, they should be pumped out and risers installed now. � 9J Inspection pipe is located over tank baffle-can not measure solids accumulation. If � tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [�j were not confirmed to be watertight by the licensed pumping contractor. If the t�anks were not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION 11-14 : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc. ) : medium-high COMMENTS: The non-conforminq septic system must be repaired by 12/31/96. �� ���if` , .�---� I.l..- �� �,��--i Date of Inspection ep System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO �O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-00 a � ON—SITE SEWAGE TRE TMENT �i r�)� �, INSPECTION REP RT ti ���kESH.��'�G Owner• Address• .�� ���J7��-Q�i1�t/1/\ /`�G� Permit �'s: Dates: �"�6_ Contractors: . City ordinance number 100 req ires that each on-site sewage treatment system in Orono be inspected on a regula basis. The on-site seWage treatment system at the above address has been inspected and appears to fall into the ategory checked below. (This is �an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"-A syst which meets all the location, design, and construction standards of the current City Codes, and which i operating satisfactorily by treating and disposing of the entire current sewage i put without dischargin any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes but was installed according to the code in effect at the time of installation, a which is operating satis actorily by treating and disposing of the entire current sewage input without dis harging any pollutants �nt ground or surface waters. 3 "NON-CONFORMING SYSTE "-A prohibited system; a system located within a designated 100-year floodpla n; any system which may r may not meet all the location, design, and construction standards of the curre t City Codes and uhich is failing for any reason; and an s stem with less than 3 feet of unsatur soil r sand � between the di tri tion device and the limitin i ar ics. (The limiting soil characteristic(� has or [ J has not been identified at this time. If the limiti g soil characteristic has not been identi'�ieZJ, this classification may be subject to revision.) TANK CONDITION C5-10): Tank inspection indicates: 5 Punpout not needed at th�s time. 6 Solids accumulation in t nks indicates they should be punped out this year to help prevent future problems. 7 Solids accumulation in t nks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pianped out uithin 48 hours to eliminate surface dischar e. 9 [nspection risers missin -tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed n each tank at next punpo t. If tanks have not been punped out within the last three years, they should be punped out now. 1 Inspection pipe is locat directly over tank baffle (does not give accurate measurement of solids accumul tion). If tanks have not en punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (17-74): Dr field inspection indicate • /�Drainfield is dry, no su facing evident. 72 Some evidence of surfaci , not critical yet. 13 Drainfield is saturated�and visibly discharging untreated effluent to the surface. Contact the City In pector imnediately. Repai s must be completed within 90 days. 14 Drainfield extent and co ition unknown. LIMITING SITE FACTORS slo s tbacks etc. : POTENTIAL FOR SYSTEM fAILURE e nds on soils water table etc. : CO NTS: � '� � �.. ► � Y�" — Date of In. pection p ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other trans er of property, be advised that this report does not guarantee or certify that an existing system will continue to fu ction properlyi but is merely an o inion of the adequacy of the system under current conditions based on the available informatton. This report st be kept on the premises with the system locetion and punping records. WHITE C�OPY/Inspectors File YELLOW COPY/Homeowner � On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TRE TMENT INSPECTiON REPORT � POST OFFICE BOX 66 i � _ � � 1335 S. Brown Rd. '� Crystal Bay,MN 55323 473-7357 � OWNER ADDRESS • PERMIT NO.'S. DATES s g'��9 CONTRACTORS � � City Ordinance No.210 re uires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site s ge treatment system at the above add has been i�spected and appears to fall into the category checked below. (This is � an e sting systern ❑ new construction) {a � Meets or exceeds urre�t City standards in all respects relating to design,construction,and location.Appears to be oper ting ,Y�- properly. � 2 Dces not meet al current City standards for new construction (1978 Code) but in most respects appea�s to be desi ned, located, and con ucted generally in accordance with previous codes.System appears to be functioning properly;no ajor upgrading of the stem is required at this time. � 3 Does not meet cu nt City standards in many respects relating to design,construction,or location.Appears to be oper ting adequately at this ime,but has a relatively high potential for future problems. No major upgrading of system is requir d at this time. � 4 System may or m not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the curr nt input,and is endangering a water supply,or is a source of pollution to surface or groundwaters, r is creating a safety h zard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system re ir/ replacement pr ures. If drainfield replacement is necessary,soil testing will usualty be required,and a design and site lan must be submitted or review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION (m Checke items may require your action) Tank'nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces n t �Pumpout not needed at this ti . give accurate measurement of solids accumulation.) If tan s ❑ Solids accumulatio� in tanks ndicates they should be pump- have not been pumped out within the last three years,th ed out thia year to help preve t future problems, should be pumped out now. ❑ Solids accumulation in tan ia at a critical level. Tanks Drai field inspection indicates: should be pumped out es aoon as posaible. �Drainfietd ia dry,�o surfacing evident. ❑ System is discF►arging to su ace. Tanks must be pumped ❑ Some evidence of surfacing,not criticat yet. within 48 hours to eliminste s rface discharge. ❑ Drainfield is saturated and visibly discharging untreate ❑ Inspection risers missing—ta ks could not be inspected, effluent to the surface. This condition may require replac - Inspection risera (4"dia.pipe must be installed in each tank ment or additions to drainfield. Contact Me City Inspect r at next pumpout. If tanks ha not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they shoul be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table ❑ Low �-Fair ❑ Lot size �-Medium ❑Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: f1V� Oate oF Inspection Septic System Inspector Note: In the event that this inspectio report is used to satisfy the requirements for a mortgage or other transfer of property,be advised th this report does not guarantee or certi y that an existi�g system will continue to function properly,but is merely an opinion of the adequac of the system under current conditions based on the available information. This repo t must be kept on the premises with system location and pumping records. WHITE CO Y/Inspector's File GOLD COPY/Homeowner