Loading...
HomeMy WebLinkAboutseptic info � O� � � ��'� O �\� a► :;�;:::� - GITY o� OIZOI�I ,,�, , w:f �� v� �y ''�, < ~ � Municipal Offices c, t�� \,r,�+,� w i:° ,t � I � �, '��* '���`w�i�4�E� G/ S t r e e t A d d r e s s: Mailin g Address: ,� .� �,�,?s.., '. '�•/ P.O. Box 66 \�.... �9kESKp¢,,� 2750 Keliey Parkway `�=�• Crystal Ba MN 55323-0066 �'��' Orono, MN 55356 y� To: Tlie Current Owner of Address 3�v�� �A C�' �� �'��1 r City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brought into compliance by: December 31,2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes � No � The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on �.-��,-�C ,5 . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: ��� �1,.��I ''ff���S .�'�'''�=T u�.9�1� � Insp ecto • � � Date of Inspection � ���� Telephone(9�2)249-4600 • Fay (9�21 249-46i6 � °� 0 0 ����- CITY of ORONO 3,. '�'„ �'�y������l� � - � E" R ,,.,t,^ � Municipal Offices \� �'�"^' ��@�r �7 ,� �� „'�� ..?. � .� Street Address: °ISoi�-a49-�6o O Mailing Address: `��ft'�KQ'g' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: �7� ��'�C o� _ /h:�i � City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treahnent system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): ( �"CODE SYSTEM"An lSTS which meet§all the location,design and construction standards of the cuirent Orono Municipal Code. 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the locadon,design and conshuction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may�Yot meet all the location,design,or construction stanc}ards of the current Orono Municip�l Code and which is failing for any reason;and any IST'S with less than three feet of unsaturated soil or sand between the dishibution device and the limiting soil chazacteristics. TANK CONDITION(5-7): � Tank inspection indica#es: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure seatietanks are aumaed throu¢h manhole and not throu¢h white insaection aipes. This allows for t6e proner cleanin¢. Keen water softner and iron filter dischar¢e out of sentic svstem to prolon¢life of drainfield. Ask pumner to test alarm float to verifv alarm is still workine in vour house. The alarm warns owner that seata�e is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three yeaxs,they should be pumped out now. D IELD CONDITION 8-10 : � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield.is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector iminediately.Repairs must be completed within 9U days. COMMENTS: M°`��� � 5���3L '�°`^�C� 1aok QK_ b ��� �� � Y�� Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under cumnt conditions based on the available anformation.