HomeMy WebLinkAbout2000-P02587 - mechanical � ' PERMIT CITY OF ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: Po2ss� Crystal Bay, Minnesota 55323 Per'mit Type: lvlechanical Permits (612) 249-4600 Date Issued: 6i2iioo SITE ADDRESS: 3680 Jacobs Mill Rd LONG LAKE, MN 55356 PID: 32-118-23-24-0009 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems Air Conditioning Ventilation DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUIIIIMARY: Permit Fee: $ 204.20 Valuation: $ 16,336.00 State Surcharge Fee: $ 8.17 TOTAL FEE: $ 212.37 APPLICANT: ANGELL AIRE INC OWNER: LECY CONSTRUCTION 12245 NICOLLET AVE S ]0340 VIK[NG DR, SUITE 105 BURNSVILLE, MN 55337 EDEN PRAIRIE,MN 55344 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITfi ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILD]NG CODE REQU[REMENTS. _ ^ . �C_.''e_..��i ���i' APPL[ ANT PERMI'CEE S[ NATURE SUED BY SIGNATURE �/,� � Copies: City,Applicant,Assessor, Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 C,ENERAL INFORMATION .. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desiens - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: x New Addition Repair Replace Residential Commercial JOB SITE: ��'C) ��r�.c"-L,� ��:1.'�� K`C.�-"l�,-/ ZIP: Owner's Name: �"Q�.� (�'�,�-��,,;,�,�,'.;,� Telephone Number: �':.�-;:���� ,+y;-�' MailingAddress: ;c�:;yo��.,7o,-w �r�. �v.-�-e /��Y' City: c'`�I';. .r='���:, .. Zip: :�:s35�� Contractor'sName: ,�;,,,�,�.;��,,�� TelephoneNumber: �;;;�-�y�-sav� Mailing Address: ,�_�,,y�s—ti,�t�rt�.� �r!�,-e_�c� City: ��r,��z������ Zip: s S 3�7 SYSTEM DESCRIPTION HEATING SYSTEMS � ����'� Quantity: � � ;`;��;��:,�;:�' �_ Make: �b�.cn,7' i:��-a������ �:�"o � Model: 35�;:;^�;�- �rS�� s�J .�,2�,�t,���?si;�;r;,"✓ Fuel: ,N,;.�-t ��� Flue Size: ;� "f'�%�� �` �!zi�� Input BTUs: �'.�ca,�aoca �1;�,,-,,, Output BTUs: -?y�c���c% �c: r:�<j CFM: �'c--���% �-- COOLING SYSTEMS Quantity: % Make: �.�,�,,p�' � Model: �3'��r;�xc,��, � Tons: � -r- f"or;_ H. Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. � Kitchen Exhaust x ducted recirculating 3���� cfm No. 3 Bath E�aust (must be ducted outside) �c�� cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) /E� -��� x .0125 $ �("�J ,�r.�U (contract price) 2. State Surcharge. ** Add the State Building Code Division Surcharge to each permit. � 3,3� x .0005 $ �. f % or $.50, whichever is greater (contract price) 3. Posta�,e and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ � >� 3"i * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. � The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. � Applicant's Signatu : Date: G-f�-�o'�--��/ Approved By: Date: G =����� r � , � G'�� � a ,�� i i PRATT � HVAC LOAD ANALYSIS � ; � for ( I i � LECY CONSTRUCTION ' � 10340 VIKING DR � EDEN PRAIRIE MN 5344 i � � i � I I � , � i � �I I � i � i � RHVACRESIDEM'IAL AND LI6HT CoMM�tCu�.HVAC LoanS Prepared By: i CR,41G ANGELL � I ANGELL-AIRE 12245 NICOLLET AVE BURNSVILLE MN 55337 612-746-5200 05-26-2000 r �;� Y F��l�NAC�WsidbnNat'�,�$Light CanmerctaL HVAC Losda Program $� � ;,�, t ������� Ellta 8oRware Developmentn,wN��-r. r�Tr� ��i`F''�`c�1'.�v S3��y'�''yYX'ya � r s r� ., x ,` �,'''.'�'.�'r�� ,t��y 'f�M1� Eagan..MNl'��;. 23u L�����;h�'„,�.�i �`�r r; >; 05 26-Z000 ,'��. �'v`` Page 2 .: • ��, , ,^ ,., , . , �� � . .. . ., . . :.,. .r. . t .� ., ,.. _ ,.:u�..�� a. ... $�RI,�'�Uth11131'�(�b3t7S ,� > Component Area Sen. Lat. Sen. Totai Description Quan Loss Gain Gain Gain 3D Window Doubie Pane Low Emit Wood Frame 624 20,724 0 29,970 29,970 11E Door Metal Urethane Core 42 734 0 188 188 12H Wall R-19+1/2"Gypsum Board(R-0.5) 2,147 11,853 0 3,040 3,040 15G Wall 5'or More Below Grade 8112"BIk+R-11 873 3,454 0 0 0 161 Ceiling R�4 Insulation 2,196 4,647 0 2,222 2,222 21A Basemt Floor 2'or More Below Grade 2,196 4,849 0 0 0 Subtotals for sUucture: 8,078 46,261 0 35,420 35,420 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appiiances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 13,349 0 7,621 7,621 Infiltration:Winter CFM:208.6,Summer CFM:69.5 666 20,484 1,652 1,484 3,136 Ventilafion:Winter CFM:69.5,Summer CFM:69.5 0 6,828 1,651 1,484 3,136 Sensible Gain Total: 47,209 Temperature Swing Multiplier: X1.00 System Load Totals: 86,922 4,223 47,209 51,433 � �ril., ..� .� :. y �Y' , �! � kk ��qr ��1��'if�t`�i� �t f .. A1 s� ��� .m �,.�- .�3 ,�` .�� �f �� ,�e�-tRrt,�',-��-��� _� Supply CFM: 2,142 CFM per square foot: 0.488 Square feet of room area: 4,392 Square feet per ton: 859.62 ���„{ ° �� �_� � Total heabng requi�ed with outside air. 86,922 Btuh 86.922 MBH Total sensible gain: 47,209 Btuh 92 �o Total latent gain: 4,223 Btuh 8 % Total cooling required with outside air. 51,433 Btuh 4.286 Tons(based on sensible+latent) 5.109 Tons(based on 77%sensible capacity) r�;:� �-� ..0� ' �< � Calculations a�e based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � Friday,May 26,2000 • N.$' • ittiYA� �iasl�Mia1��.IghCCommercla(HVAC losds Program� ��� � � n Elite Sottware Devalopment,h�c.�� � �� . �a�" ��i}a�H��i.y�.l�.r}, P� . �� i y , �., '-"�.r t<, r t t y� . �dm :� ���.I � p 71��5����k 1 �':W'�xY'�Yk 4 �. 1J iV .J J � 1 t ,>�.agan.NIN.S5'i2��t�,���x ��k � , ,�° z� 05-26-2000, ` '�Page 3 S�'f[I��Ofl@�7$W11t1181�/LQilds�+ ` Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 435 14,447 0 21,255 21,255 11E Door Metal Urethane Core 42 734 0 188 188 12H Wall R-19+112"Gypsum Board(R-0.5) 1,463 8,077 0 2,072 2,072 161 Ceiling R�4 Insulation 2,196 4,647 0 2,222 2,222 Subtotais fa stnicture: 4,136 27,905 0 25,737 25,737 Active People: 2 0 460 600 1,060 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwark: 0 8,515 0 5,480 5,480 infiitration:Winter CFM: 149.4, Summer CFM:49.8 477 14,671 1,183 1,063 2,246 Ventilation:Winter CFM:44.4, Summer CFM:50.0 0 nla n/a n/a nla Sensible Gain Total: 32,880 Temperature Swing Multiplier: X1.00 Zone Load Totals: 51,091 1,643 32,880 34,523 �...... " �, �.�F� �`���y�r�.���_.��e�^d a� �� � s�,�'t�#''���i'� y � k�.'`�"�` ��r�,.�},�'��� �; �' �,•e�,�d"'�r�i'3 � m� b, y �n.w,.` _ � .�?a3�" � .k-t r��£a .'�,P. ..�w, �,'�,, ;�i� Supply CFM: 1,540 CFM per square foot: 0.701 Square feet of room area: 2,196 Square feet per ton: 686.859 , . � ::. ,i.. ... ,;.� � .. .. .,..�,re.r.. �4 yA e" �i.Y�F f �L��ti viCc 4 ki _ .� � �_ � �i�.�a�m s�}� R �yyy Y+�Q � � �y.�. ,tnyyDl"_'-� � , 4 s..v.Y"5 4���y.�; Total heating required with outside air. 51,091 Btuh 51.091 MBH Total sensible gain: 32,880 Btuh 95 % Total latent gain: 1,643 Btuh 5 % Total cooling required wi#h outside air. 34,523 Btuh 2.877 Tons(based on sensible+latent) 3.197 Tons(based on 77%sensible capaaty) Friday,May 26,2000 w ^ RF11�A� Ru(�tntlaf�LIgM Commerc(aI HVAG Loads Program z Ellte 8oftwaro DevelopmeM,lnc. ^' s 1a .AI7Qelf-Aife'�,�`#������`t�"�,, � � �„w ,� ,: 3 - ��'�� `PRATF 'Eagart FAN 55�t23 ti� � .;;� '.�f Page 4 ; . , ey � 05-26-2000 ' Systeni�1 Zone#2 Summaty Lo�ids` ' � Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 189 6,277 0 8,715 8,715 12H Wall R-19+1/2"Gypsum Board(R-0.5) 684 3,776 0 968 968 15G Wal(5'or More Below Grade 8112"BIk+R-11 873 3,454 0 0 0 21A Basemt Floor 2'or More Below Grade 2,196 4,849 0 0 0 Subtotals for structure: 3,942 18,356 0 9,683 9,683 Active People: 2 0 460 600 1,060 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductuuo�k: 0 4,834 0 2,141 2,141 Infiltration:Winter CFM:59.2, Summer CFM: 19.7 189 5,813 469 421 890 Ventilation:Winter CFM:25.2, Summer CFM: 19.5 0 n/a n/a nla nla Sensible Gain Total: 12,845 Temperature Swing Multiplier. X1.00 Zone Load Totais: 29,003 929 12,845 13,774 ��..M � .8' , ,.� � '°B A<,�y� .,+�A�g R i � � „� �` � � '4s p�'i :: �4+v�G�^ `� �' � k. �r � ; .3 � s Y� t ,'�d^,ei { �r �3 y' ?'�r '' �. .�� �.,.c"t?:T ,S� .X ..;.Ks � r` A r..�.�'. �tz..,�. � �S"' n:�2� `�� „! Supply CFM: 602 CFM per square foot: 0.274 Square feet of room area: 2,196 Square feet per ton: 1,652.481 � k�k'w?�t,�`P a������` � �'�,�#p,,�, ��'"�4�>'-3s�r�.`'k.�} �'� "' �`"�,'�. �'�f�a '' `�,..�-�`r . _�� . , +s.�,�',�.5`:^SA ,.� ..: m �?_, i'-1r �{5',_,. , , ..: ,�-a'. 2i'1"}' _ .. k� _:.,a Total heating required with outside air. 29,003 Btuh 29.003 MBH Total sensible gain: 12,845 Btuh 93 % Total latent gain: 929 Btuh 7 °/a Total cooling required with outside air. 13,774 Btuh 1.148 Tons(based on sensible+latent) 1.329 Tons(based on 77%sensible capaaty) Friday,May 26,2000 DATE TIME CITY OF ORONO CALLED IN '�, -O a INSPECTION NOTICE SCHEDULED �,��S-vo �, pc�. PERMIT NO. ��� �� COMPLETED �:�-- --�---- ADDRESS � � g � , OWNER CONTR. � �-'`� TELEPHON E NO. c/� 2- � �F-lc SZ-v � � DESCRIPTION rn�� � 1'�`� � lu 01 FOOTING -�d�HANICAL RI 18 EXCA GRADING/FILLING � 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS � 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL � 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Z Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP W 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL � 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL J Q OWNERICONTRACTOR TO MEET YOU:_YES_NO Z � MMENTS: � � � o re��.� �Yr 2��,� � /��-o � ' J L� s O � � O C� �_S W t Q. (� I2 � i �5 �t,c- 4.. z W � W � � d ❑WORKSATISFACTORY:PROCEED ❑ PROJECTCOMPLETE W � �❑ CORRECT WORK&PROCEED �' ISSUE CERTIFICATE OF OCCUPANCY W O �ORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORECOVERING PERMANENT ❑ CORRECT UNSAFE CONDITION WITHIN HOURS. i ' PHOTO TAKEN INSPECTOR WILL RETURN � CITATION ISSUED C STOP ORDER POSTED.CALL INSPECTOR [� INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. 249-46�0 OwnerlContrac or on site: Inspector. White Copyllnspector's File Canary CopylSite Notice