Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2003-P05980 - mechanical
' �� PERMIT � � CITY OF ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: Pos9so Crystal Bay, Minnesota 55323 Permit Type: Me�nani�al Pe�ts (952) 249-4600 Date Issued: i�23i2oo3 SITE ADDRESS: 1125 Hunter Dr Wayzata,MN 55391 PID: 25-118-23-31-0004 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Sub-type(s): Mulriple Mechanical Items Permit Type: Mechanical Permits DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Pernvt Fee: $ 251.24 Valuation: $ 20,099.00 State Surcharge Fee: $ 10.05 TOTAL FEE: $ 261.29 APPLICANT: Watertown Sheet Metal OWNER: Christopher Perry 14730 Hwy 7 1125 Hunter Dr Mayer, MN 55360 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. ., � 1 . ��� . � /t.� ` � � � � J APPLICANTPCRMITL ATURL ISSUEDBYSIG'�'ATI;RE Copies: 1-File(Sieriitures Required), 1-Applicant, 1-Monthlv Reoorts, 1-Assessin�, 1-Fina�lce Page 1 ! �f �'+.� ! � , � CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a pernut will be issued within two working days. 2. Permit cards will be sent by retum mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECENE A PERMIT. WORK MUST NOT BEG1N UNTII,THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs-Complete calculations, details and specifications are required for each heating, ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call (952)249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one: ❑ New � Addition ❑ Repair ❑ Replace�] Residential ❑ Commercial JOB SITE: ,`%,%J //��(T�f�/r cJ�iQ, /P��f ro4�ir' Zip: �Jr3 Owner's Name: � ' °� o ! , Phone Number: Mailing Address: ;;,.�;;,;t-` City: Zip: Contractor's Name: U��"�Ek'���vr�J�ft'������hone Number: ���� ��lJ��—'���� Mailing Address: 1{f 1"? � ��a�t^ i City: /'l';,4 ;�f/' Zip• ,�r 3l, J 1 r � � .. � SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: Make: L�/i�7�� ��/7/,'c7�'' Model: Fuel: ��i R; /1��'T �i�i5 Flue Size: .-i �i ���a� r0�� Input BTUs: � Output BTUs: � � Q CFM: �'� �� COOLING SYSTEMS Quantity: Make: G E6?/j� �/7�� Model: ,���� ��� �/✓��'/7� Tons: �� H.Po�ver � ` FIREPLACES GAS LINE ONLY ❑ Gas factory fireplace ❑ Installing a Gas Line Only ❑ Wood burning factory fireplace with flue ❑ Wood Stove ❑ Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust duct recalculating cfm No.�_Bath Exhaust(must have duct outside) ;;� cfm No._2_Other Fans: Locations �� �1='%��<,��'�`/�'�,C;�f; cfm /�'� FUEL STORAGE (MUST BE APPROVED BY FIItE MARSHAL) ❑ Installation or ❑ Removal ❑Fuel oil: gallons ❑ underground ❑ inside ❑outside ❑ LP Gas: gallons �}Other �/�T. ���5 � Gas opening 2 � l ' L l PERMIT FEE CALCULATION(S) 2002 State Statute ❑ Yes This Section Applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$500.00 or less; excludin�the cost of the fixture or appliance: and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Pernut $ 15.00 State Surcharge $ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: L Contract Price* is .0125% of job with a Minimum Fee of($35.00) �c� �c'�'" X 0125 $ ,�'�� ,�� (con act price) (minimum$35.00) 2. State Surchar�e. ** Add the State Building Code Division a Minimum Fee of($ .50) ��%i�`�� x.0005 $ /���� (contract price) (minimum$.50) 3. Postage and Handlin� (Only rnail-i�t applications) $ �g— 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ ����,� � *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work induding materials,labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment,labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. **The STATE SURCHARGE is.0005 of the contract price under�1,00Q000 or$.50-whichever is greater.For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code,and certifies that all statements made on this application are complete,true and correct. /� /� �j Applicant's Signature: � J`'�-t_(�. l����' Date: ��o<��� � Approved By: Date: 3 1 � LENIVOX RESIDENTIAL HEATING DATA SHEET JOB NAME: �4'v�5 �.� DATE - ,2.� 6 S ADDRESS: � - �f�7��'rE' �is�l�!� OUTDOOR TEMP: -�02 U INDOOR TEMP: � D TEMP. DIFFERENCE: O DESIGN TEMPERATURE DIFFERENCE MOVABLE GLASS WINDOWS S�E TRE 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 39 45 52 58 65 71 78 84 90 97 103 110 116 123 SINGLE GLASS W/STORM 21 25 28 31 35 38 42 45 49 52 56 59 63 66 DOUBLE GLASS 28 32 37 41 46 50 55 60 64 69 73 78 82 87 DOUBLE GLASS W/STORM 16 19 21 24 27 29 32 35 37 40 42 45 48 50 DESIGN TEMPERATURE DIFFERENCE SLIDING GLASS DOORS S�E TR� 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 42 48 55 62 69 76 83 90 97 104 110 117 124 131 SINGLE GLASS W/STORM 22 26 29 33 37 40 44 48 51 55 59 62 66 70 DOU B LE G LASS 29 34 39 43 48 53 58 63 67 72 77 82 87 91 DESIGN TEMPERATURE DIFFERENCE DOORS SnE TRE � �` � � � � � �` �� � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER SO LI D W 00 D 31 36 41 46 51 56 62 67 72 77 82 87 92 97 SOLID WOOD** 18 21 24 27 30 33 36 39 42 45 47 50 53 56 METAL URETHANE 23 27 30 34 38 42 45 49 53 57 60 64 68 72 METAL URETHANE** 13 16 18 20 22 25 27 29 31 33 36 38 40 42 **Weatherstripped or Storm RUNNING FEET �� CEILING HEIGHT X WALLS GROSS WALL �-�3 O WINDOWS & DOOR AREAS - ��'�o NET WALL AREA �� DESIGN TEMPERATURE DIFFERENCE FRAME WALL S�E TRE � � � � � � � �' �� 75 � �' � � HEAT LOSS HEAT TRANSFER MULTIPLIER NOINSULATION 8 10 11 12 14 15 17 18 19 21 22 23 25 26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 8.1 8.5 R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 6.3 6.6 R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1/2" POLYSTYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4.7 4.9 5.2 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH ABOVE GRADE FEET � � � � � � � �' �� � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 16 18 21 23 26 28 31 33 36 38 41 44 46 49 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.5 3.8 4.2 4.6 5.0 5.4 5.8 6.2 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.6 3.8 4.1 4.3 4.6 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH BELOW GRADE FEET � � � �' � � � � �� � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NOINSULATION Q 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.6 10.311.011.812.513.214.0 R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4 7.8 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL � 3 � Heat Loss Subtotal from Page 1 �! � DESIGN TEMPERATURE DIFFERENCE CEIIING S�E TRE � � � � � �' � �' �� � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NO I N SU LATI O N 18 21 24 27 30 33 36 39 42 45 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.6 7.0 7.5 7.9 8.4 R-19, 6" INSULATION 1.6 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 4.8 5.0 R-30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.8 3.0 3.1 R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2.2 2.3 2.5 DESIGN TEMPERATURE DIFFERENCE FLOOR OVER AN SQUARE � � � � � � � � �� � � � � � BTUH UNCONDITIONED SPACE FEET HEAT TRANSFER MULTIPLIER HEAT LOSS NOINSULATION 10 11 13 14 16 17 19 21 22 24 25 27 28 30 R-11, 3" INSULATION G' ' 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 R-19, 6"INSULATION 1.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4 4.7 4.9 R-30, 10"INSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.1 3.3 3.5 DESIGN TEMPERATURE DIFFERENCE BASEMENT FLOOR SaE TRE 30 35 40 45 50 55 60 65 �0 75 80 � � � HEAT LOSS HEAT TRANSFER MULTIPLIER BASEMENT FLOOR 0.8 1.0 1.1 1.3 1.4 1.5 1.7 1.8 2.0 2.1 2.2 2.4 2.5 2.7 DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB WITHOUT LINEAR BTUH PERIMETER SYSTEM FOOT � � � � � � � �' �� � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 37 41 45 49 53 57 61 65 69 73 77 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8 17.8 18.9 20.0 DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB LINEAR � � � � � � � � �� � � � � � BTUH WITH PERIMETER SYSTEM FOOT HEAT TRANSFER MULTIPLIER HEAT LOSS NO EDGE INSULATION 57 67 76 86 95 105 114 124 133 143 152 162 171 181 1" EDGE INSULATION 34 40 46 52 57 63 69 74 80 86 91 97 103 109 2" EDGE INSULATION 28 33 37 42 47 51 56 61 65 70 75 79 84 89 An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than.5 CFM per linear foot of crack. INFILTRATION/ ��OFLOOR SQ FT. c�CEILING HEIGHT =����BIC FT VENTILATION 0.40���CUBIC Ff = 60 =��CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 45 50 55 60 65 70 75 80 85 90 � HEAT LOSS HEAT TRANSFER MULTIPLIER INFILTRATION 33 39 44 50 55 61 66 72 77 83 88 94 99 105 CO MECHANICAL VENTILATION p 33 39 44 50 55 61 66 72 71 83 88 94 99 105 HEAT LOSS SUBTOTAL DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% (.15) R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) TOTAL HEAT LOSS � D�- NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. HL-841-L7 Op23qq Litho U.S.A. ' � LENNOX RESIDENTIAL COOLING DATA SHEET JOB NAME: �'�P DATE Z.-- � ADDRESS: /02 - �1.� tiQ � �y�! fi9 OUTDOOR TEMP: INDOOR TEMP: � TEMP DIFFERENCE: 02 � SENSIBLE LOAD CALCULATIONS GLASS SINGLE DOUBLE TRIPLE NO SHADE DESIGN TEMPERATURE DIFFERENCE COMPASS GLASS AREA �0 15 20 25 30 35 10 15 20 25 30 35 10 15 20 25 30 35 BTUH POINT SQ. FE T HEAT TRANSFER MULTIPLIER HEAT GAIN N 29 33 37 41 45 20 22 24 26 28 30 15 16 18 19 20 21 N E& N W 5 60 65 70 75 80 50 52 54 56 58 60 37 38 40 41 42 44 E& W 85 90 95 100 105 70 72 74 76 78 80 55 56 58 59 60 62 SE& SW 7 74 78 82 86 90 60 62 64 66 68 70 47 49 51 52 53 54 S 44 48 52 56 60 35 37 39 41 43 45 26 27 29 31 32 33 GLASS SINGLE DOUB E TRIPLE INSIDE SHADE DESIGN TEMPERAT E DIFFERENCE COMPASS GLASS AREA �0 15 20 25 30 35 10 15 20 25 30 35 10 15 20 25 30 35 BTUH POINT SQ. FEET HEAT TRANSFER MULTIPLIER HEAT GAIN N 15 19 23 27 31 35 15 17 19 21 23 25 10 12 14 16 17 19 � N E& N W 35 39 43 47 51 55 30 32 34 36 38 40 22 24 26 28 30 31 E& W 50 54 58 62 66 70 45 47 49 51 53 55 35 36 38 40 42 44 SE& SW 40 44 48 52 56 60 35 37 39 41 43 45 29 30 32 34 36 38 S 25 29 33 37 41 45 20 22 24 26 28 30 16 18 20 22 24 26 02 DESIGN TEMPERATURE DIFFERENCE DOORS SnEETRE 10 15 20 25 30 35 HEAT GAIN HEAT TRANSFER MULTIPLIER SOLID WOOD 6.3 8.6 10.9 13.2 14.4 15.5 SOLID WOOD '* 4.2 5.7 7.3 8.8 9.6 10.4 - '- METAL URETHANE 2.6 3.5 4.5 5.4 5.9 6.4 METAL URETHANE ** 2.2 3.0 3.8 4.6 5.0 5.4 "* Weatherstripped or Storm RUNNING FEET g� CEILING HEIGHT X WALLS GROSS WALL = WINDOWS & DOOR AREAS - �i�l� NET WALL AREA � DESIGN TEMPERATURE DIFFERENCE FRAME WALL S�E TRE 10 15 20 25 30 35 HEAT GAIN HEAT TRANSFER MULTIPLIER NOINSULATION 3.7 5.0 6.4 7.8 8.5 9.1 R-11, 3" INSULATION 1.2 1.7 2.1 2.6 2.8 3.0 R-13, 3-1/2" INSULATION 1.1 1.5 1.9 2.3 2.5 2.7 R-13 + 1" POLYSTYRENE 0.8 1.1 1.4 1.7 1.8 2.0 R-19 + 1/2" POLYSTYRENE 0.7 1.0 1.3 1.6 1.7 1.8 O MASONRY WALL SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH ABOVE GRADE FEET �� HEAT TRANSFER MULTIPLI R � HEAT GAIN NOINSULATION 3.2 5.8 8.3 10.9 12.2 13.4 R-5, 1" INSULATION 0.9 1.6 2.3 3.1 3.5 3.8 R-11, 3" INSULATION 0.5 0.9 1.3 1.6 1.8 2.0 R-19, 6" INSULATION 0.3 0.5 0.8 1.0 1.2 1.3 SENSIBLE HEAT GAIN SUBTOTAL `s0(� r�---_ . Sensible Heat Gain Subtotal from Page 1 / -� ��/ � ` SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH CEILING FEET �0 15 20 25 � �` HEAT GAIN HEAT TRANSFER MULTIPLIER No Insulation 14.9 17.0 19.2 21.4 22.5 23.6 R-11, 3" Insulation 2.8 3.2 3.7 4.1 4.3 4.5 R-19, 6" Insulation 1.8 2.1 2.3 2.6 2.8 2.9 R-30, 10" Insulation 1.1 1.3 1.5 1.6 1.7 1.8 R-38, 12" Insulation 0.9 1.0 1.1 1.3 1.3 1.4 FLOOR OVER SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET �� HEAT TRANSFER ULTIPLI R � HEAT GAIN No Insulation 1.9 3.9 5.8 7.7 8.7 9.6 CARPET FLOOR-NO INSULATION c7C� 1.3 2.5 3.8 5.1 5.7 6.3 R-11, 3" INSULATION 0.4 0.8 1.3 1.7 1.9 2.1 R-19, 6" INSULATION 0.3 0.5 0.8 1.1 1.2 1.3 R-30, 10" INSULATION 0.2 0.4 0.6 0.7 0.8 0.9 FLOOR SQ FT. x___p_CEILING HEIGHT�O,�'"�UBIC FT INFILTRATION/ �� O 'J 0.40 x���UBIC Ff = 60 = �.�CFM VENTILATION MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 10 15 20 �` � � HEAT GAIN HEAT TRANSFER MULTIPLIER INFILTRATION �, 11.0 16.5 22.0 27.0 32.0 38.0 MECHANICAL VENTILATION t� 11.0 16.5 22.0 27.0 32.0 38.0 INTERNAL HEAT GAIN BTUH HEAT GAIN Number of People x 300 ��� Kitchen Allowance 1,200 SENSIBLE HEAT GAIN SUBTOTAL t ( DUCT GAIN BTUH HEAT GAIN R-4, 1" Flexible Blanket Insulation: ADD 15°k (.15) R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) TOTAL SENSIBLE HEAT GAIN 0 LATENT LOAD CALCUI.ATIONS Conditions Outdoor Wet Bulb indoor Wet Bulb Grains Wet 80 62.5 50 ediu 75 62.5 35 edium Dry 70 62.5 20 Dry 65 62.5 0 Based on 75°F Indoor Dry Bulb at 50% RH. / LATENT LOA�-�ILTRATION ��� 0.68 x Grains x � o�- Infiltration CFM LATENT LOAD-VENTILATION 1� /- 0.68 x � Grains x �Ventilation CFM 7 ��P � LATENT LOAD-PEOPLE /�^� Number of People x 230 � � TOTAL LATENT HEAT GAIN � TOTAL SENSIBLE AND LATENT HEAT GAIN C? NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition and for a medium outdoor daily temperature range. CL-841-V 002345 Litho U.S.A.