Loading...
HomeMy WebLinkAboutseptic info �« � Minnesota Pollution Compliance Inspection Form ���� �.,- Control Agenty 520lafayette Road North Existing Subsurface Sewage Treatment Systems (SSTS) St.Paul,MN 55155-4194 Doc Type:Compliance and Enforcement InspeCtion results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes: requirements and attached forms—additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days System Status System status on date(mm/dd/yyyy): 11/10/2016 � Compliant— Certificate of Compliance ❑ Noncompliant— Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.) frame outlined in Local Ordinance.) Reason(s)for noncompliance (check all applicable) ❑ Impact on Public Health (Compliance Component#1)—Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance Component#3)—Imminent threaf to public hea/th and safety ❑ Tank Integrity(Compliance Component#2)—Failing to protect groundwater ❑ Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater ❑ Soil Separation (Compliance Componenf#4)—Failing to protect groundwater ❑ Operating permiUmonitoring plan requirements(Compliance Component#5)—Noncompliant Property Information Parcel ID#or Sec/Twp/Range: Property address: 215 Hollander Road Reason for inspection: New Installation Property owner: Owner's phone: or Owner's representative: Haye&Sons Excavating Inc. Representative phone: (763)479-1762 Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600 Brief system description: Type III Mound _ ___ Comments or recommendations: New Installation Certification 1 hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system peiformance has been nor can be made due to unknown conditions during system construction, possib/e abuse of the system, inadequate maintenance, or future water usage. Inspector name: Roger Peitso Certification number: #6683 Business name: License number: Inspector signature: _ Phone number: 952-249-4625 Necessary or Locally Required Attachments ❑ Soil boring logs ❑ System/As-built drawing ❑ Forms per local ordinance ❑ Other information (list): www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31b • 6/4/14 Poge 1 of 3 Property address: 215 Hollander Road Inspector initials/Date: RLP � 11/10/2016 (mm/dd/yyyy) 1. Impact on Public Health— Compliance component#1 of 5 Com liance criteria: Veri�cation method(s): System discharges sewage to the ❑Yes � No ❑ Searched for surface outlet round surface. ❑ Searched for seeping in yard/backup in home System discharges sewage to drain ❑Yes � No ❑ Excessive ponding in soil system/D-boxes tile or surface waters. ❑ Homeowner testimony(See Comments/Explanation) System causes sewage backup into ❑Yes � No ❑"Black soil°above soil dispersal system dwelling or establishment. ❑ System requires"emergency"pumping Any"yes"answer above indicates the ❑ Performed dye test system is an imminent threat to public ❑ Unable to verify(See Comments/Explanation) hea/th and safety. ❑Other methods not listed(See Comments/Explanation) Com ments/Explanation: New installation 2. Tank Integrity— Compliance component#2 of 5 Com liance criteria: Verification method(s): System consists of a seepage pit, ❑Yes � No ❑ Probed tank(s)bottom cesspool,drywell,or leaching pit. ❑ Examined construction records Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach) com liant if allowed in local ordinance. Sewage tank(s)leak below their ❑Yes � No � Observed liquid level below operating depth designed operating depth. ❑ Examined empty(pumped)tanks(s) If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for"black soil" Any "yes"answer above indicates the ❑ Unable to verify(See Comments/Explanation) system is failing to protect groundwater. ❑ Other methods not listed(See Comments/Explanation) Com ments/Explanation: New installation of tanks 3. Other COmplianCe ConditiOns—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to be structurally unsound. ❑Yes* �No ❑Unknown b. Other issues(electrical hazarcls,etc.)to immediatety and adversely impact public health or safety. ❑Yes" �No ❑Unknown "System is an imminent threat to public healUi and safety. Explain: c. System is non-protective of ground water for other conditions as determined by inspector. ❑Yes* �No *System is failing to protect groundwater. Explain: www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TT1f 651-282-5332 or 800-657-3864 • Available in altemative formats wq-wwists4-316 • 6/4/14 Poge 2 of 3 ,. Property address: 215 Hollander Road Inspector initials/Date: RLP � 11/10/2016 (mMdd/YYYY) 4. Soil Separation—Compliance component#4 of 5 Date of installation: 11/10/2016 ❑ Unknown Verification method(s): (mm/dd/YYYY) ShorelandNVellhead protectioNFood beverage Soil obseivafion does not expire. Previous soil lodging? ❑Yes � No observations by two independent parties a�sufficient unless site conditions have been altered orlocal Com lianCe Criteria: requirements differ. For systems built prior to April 1, 1996, and ❑Yes ❑ No ❑ Conducted soil observation(s)(Attach boring logs) not located in Shore/and or Wellhead Protection Area or not serving a food, ❑Two previous verifications(Attach boring logs) beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drainfield) Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) separation distance from periodically ❑ Other(See Comments�Explanation) saturated soil or bedrock. Non perfom►ance systems builtApril 1, �Yes ❑ No Comments/Explanation: 1996, or later or for non performance systems located in Shoreland orWellhead New Installation Protection Areas or serving a food, beverage, orlodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* "Experimental'; "Othe�'; or Pe►formance" ❑Yes ❑ No Indicate de ths or elevations systems built under pre-2008 Rules;Type IV or V systems built under 2008 Rules(7080. A. Bottom of distribution media 2350 or 7080.2400 (Advanced Inspector License required) B. Periodicall saturated soil/bedrock Drainfield meets the designed vertical C. S stem se aration separation distance from periodically saturated soil or bedrock. D. Re uired compliance se aration* Any "no"answer above indicates the system is "May be reduced up to 15 percent if allowed by Local failing to protect groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 � Not applicable Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required Is the system required to employ a Nitrogen BMP? ❑Yes ❑ No If"yes", B below is required BMP=Best Management Practice(s)specified in the system design If the answer to both questions is "no", this section does not need to be completed. Com liance criteria a. Operating Permit number: ❑Yes ❑ No Have the O eratin Permit re uirements been met? b. Is the re uired nitro en BMP in lace and ro erl functionin ? ❑Yes ❑ No Any"no"answer indicates Noncompliance. Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded,replaced,or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance.If the system is failing to protect ground water,the system must be upgraded,replaced,or its use discontinued within the time required by local ordinance.If an existing system is not failing as defined in law,and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced,or its use discontinued,notwithstanding any local ordinance that is more strict This provision does not apply to systems in shoreland areas, Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in altemative formats wq-wwists4-316 • 6/4/14 Page 3 of 3 � � \\` �\�\ � i' O\`\\ ����;,,:x�:,..*,:. �i��� 4� ��.��� ;1Yt4w�„:;�:•wr:,% � F'� �,: , •: � �; , �,;.,,��cF;i'_ � �� Municipal Offices � � t b�'r+ �':>' `�'.� 'C� � '`'� ��,«"��?�.ti G� Street Address: Mailing Address: `', � �� •�.,:.;�,.l;l.;���r. .�;% P.O, Box 66 ���kE$I3��-'� 2150 Kelley Parkway . `�� Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Cunent Owner of Address o7 � � i�o� i�^ ��� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewa?e treatment system at the above address has been inspected and the following is l:nown about the system. A sketch of tlie known components of the system is available for most properties at the Orono City HaIL Imminent Public Health Thi-eat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be broujht into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identifi as Non-Compliant Yes No If yes, system must be brouaht into compliance by: December 31, 2007 � December 31, 2010 � . Other Septic Tank(s) Pump out Needed Yes no � The City recommends the septic tank(s) and/ar lift tank be serviced and pumped out every tYv:ee years. City records indicate the tank(s) were last pumped out on �{�('� .�(,� . The tanl:(s) should be cleaned through the mailhole and not throu�h tlze inspection pipes, tlus allows for pro per cleaning. Comments: P a ;�� � � , " Date of Inspection ��'� l� • Insp.c�;pq ,� � Telephone (9_2) 2�9-4600 • Fax (9�3:i 2�9-461( �' �O \ � � •: •, ,.,� . .�;: „ . _ `. �,.�:..y. . M-. ..�:' ..;'i..i. .. .�.,. ,/ \ ,; ��; { �� '� CITY of ORONO , .. ,, ,; :. . , � ,t�h�,� . . . �7/ �C � � �f''�. '��' �. ��r M11111C1j� ��CPS ��;:�,.. �� ^:.�,:����b:'.�,t�� G a �� •� .� Street Address: qsa- 49-y6o o Mailing Add�ess: �'EgytOg' 2750 Kelley Parkway � P.O. Box 66 Orono, MN 55356 . Crystal Bay, MN 55323-0066 . als Ho�la�de� ��/ To Current Owner: Address. City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories cHecked below. SYSTEM CONFORMITY (1-3): � 1 "CODE'SYS1'EM"An IS'FS which meefs ali the location,design and construction standards of the cutrent Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which dces not meet all the location,design and construction standards of the current Orono . Municipal Code but does meet the three foot separarion requirement or two foot requirement for systems installed 1996 or earlier,and wluch is not failing or an imminent threat to public health or safety. 3�"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which.may or may not meet all the location,design,or construction standards of the cwrent Orono Municipal Code and which is failing for ang reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribudon device and the limiting soil charaderistics. TANK CONDITTON(5-71: b . Tank inspection indicates: 5 Pumpout not needed at this time. �Septic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 years. . Tank was last pumped �Z-Z'°Z l. Make sure seatic tanks are aumaed throu¢h manhole and not throu¢h white inspection aines. This ailows for the uroaer . , cleanine. Keea water softner and iron fitter discharge out of seatic svstem to prolone life of drainfield. Ask aumaer to test alarm float to verifv alarm is still working in vour house. The alarm warns owner that septase is about to backua into basement 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : b ' . 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. � . 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector � . immediately.Repairs must be completed within 90 days. COMTvIENTS• ��tA•n�=:t��U � "= 13 c�d��,:td��, r�,�,r ,�„J �„`,,�-. l,.L. � � ��c�� �i=1�-zd�o, v� Sc �,`�-- �ks Su., c� �o o� _ �'—�� —0`a � ��� --� � � �; Date of Inspection Matt Bolterman - Septic System Inspector • Notc.: ln the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report dues not guarantee or certify that an e�isting system will continue to function properly. bi�t is merely an opinion oF the adequac�• of the s��stem under current conditions based on die availabte inl'ormation. � °� o �. � � - ��:�-� � � CITY of 4RON0 - � �l1 1r� � �� � �,� �iY/r �, •� MII�C�� Q�CC.4 : �� ,�' �i �'yG � ' � Street Addrou: Maiqa��ddreu: �'SH�g . 2750 Kelley Pa�krvaY P.0.�6oii 66;:� Orono. MN 55356� � � �� Crystal Bay, MN 5532 66 - � . � 9Sd•�49=4600 - - , , .���.�s� v . � �S I-I o 11 ��t�er (�,� �. .� 7,. To Current Owner: Address: a City Ordinance 199 requires that each existing on-site sewage treatment§ystem in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fatt into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYST'EM"An ISTS which meets a(i the location,design and construction standazds of the eument Orono Municipal Code. 2 "COMPLIANT SYST'EM" An ISl'S which does not mat ali the location,design and co�struction siandards of the currcnt Orono Municipal Code but doa mat the tfuee foot sepuadon requircmrnt or two foot rcqui�ement for systertu installed 1996 or eartier,and which is not failing o� aa imminent threat to public health or safety. � 3O "NON-COMPLIANT SYSTEM" A prohibiud IS1'S;an ISTS la�ated within a designated l00-year flood plain.any ISTS which may o�may not meet ali the location,daign.or construction standards of dx cument Orono Municipal Code and which is failing for my rcason;and any ISTS with less than ihree feet of unsaduated soil or sand betwan the distribution device and the limiting soil characteristics. TANK CONDITION(5:��: 6 Tank inspecrion indicates: � � . � � Pumpout not needed at this time. Septic tanks must be pumped out thq year (city code requires tanks to be pumped out once every 3 years. Taalc was last pumped Lt-'i-0 ). �Vlake sure seatic tanks are aumaed throu�h manhole and not throush white insoection aiaes. This allows for the aroaer cleanin¢. � 7 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank. INFIELD CONDTTION lC� : a . . 8 Drainfield is dry,no surfacing eviden� Some evidence of surfacing,not crirical yet . 10_ Drainfield is saturated and visibly dischacging untreated ef�luent W the surface. Contact the City Inspector � � immediately.Repairs must be completed within 90 days. CONIlVIENTS: S S tc�-- �S �0� c_.d 1,�.�- o�� rr.�5� 5c. (' 14u� � \2.=3l-2.0�0 0 f�c n S t1 r�,c� �n�. � i't '�L � �'�.�.�-.�t.� - � . �? =3 a -oa- �ct� . Date of Inspxtion Matt Boltennan- Sepdc System Inspector Note:In the event that this inspection report is used W satisfy the cequircme�for a moctgage or other transfa of propecty.be advised that this ceport doe.s not guaraneee o�cercify d�at an pcisting system wtU continue W function propedy.but is ma�ely an opWon ofthe adequacy of the system under eucrent con�dons based on the avallable infonnation. _ �o� 0 0 !,, =,, a�r��-� ,� CITY of ORONO 1,r�l � � � �`„ ` �. '�� , �r Municipal Offices ,� �� i�,� �;����a'� 'ti l�'_ , ,! ; , ,'e".��.�G Street Addross: MailinQ Addrou: -'�'EgH04' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 October 18, 2000 Blair&Mary McKeever 215 Hollander Road Wayzata, MN 55391 Dear Mr. &Mrs. McKeever: An inspection of your septic system was conducted on October 3, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout not needed at this time. The septic system is,nt�n-compliant due to a lack of a three foot sepazation distance between the bottom of the drainfield to th�seasonally high watertable. The three foot requirement is a State Code,not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic system must be replaced by December 31,2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regulaz basis. Also enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the appro�mate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. Re ec 1 , t"� � Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,6e advised that this report does no guarantee or certify the esisting system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www ci.orono.mn.us =�°� - o 0 -, f:�� � CITY of ORONO �,`.�l ,�,. .. ,.<, � �,� � � ���f �lSr Municipal Offices � ,�,,��;��`�F��'°�yG Street Address: Mailing Address: `��gg04' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay; MN 55323-0066 Owner: V�.1�C�! � /�1cK,�.,��Pr Address: 215 Hollander Rd. Permit #'s: 7692, 166 Dates: 10/31/84, 9/11/87 Contractors: Gene Hayes, E. J. Peterson Co. (This is [ �] an existing system ( ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance wittt previous codes and is functioning properly. � Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [�] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) NK CONDITION (5-9) : 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is (�unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : lo�v COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008. • i //- ��- 9� Date of Inspection S ic System I spector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this ,report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT � � INSPECTION REPORT ti '�' G �9kESH��'� X �'� �� 1 L�l IGf��I�' /�E.[ Owner• Address• • Permit #'s: Dates: 1V� � Contractors: �� �XG•% I I�fpTP{-� 1.1J• City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): � � "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (7he limiting soil characteristic � has or [ 7 has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): � T�alc inspection indicates: /5> Pumpout not needed at this time. b Solids accumulation in tanks indicates they should be p�xnped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. 7anks must be p�xnped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. ]nspection risers (4" dia. pipe) must be installed in each tank at next purnpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D�field inspection indicates: 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �� COMMENTS: Date of Inspection Se ic Syste Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prEmises uith the system loc=tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATMENT � �, INSPECTION REPORT ti ��9k'EsHog'�G Owner: J ��T�� C���� Address: �� ��L/��e��� Permit #�'s: � Dates: — Contractors: �J'�TKl1��/��J� r��� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is py.an existing system [ ] new construction) SYSTEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standa�ds of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet atl the location, design, and construction standards of the current City Codes and which is faili�g for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �1—has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION C5-10): Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each tank at next punpout. If tanks have not been punped out within the last three years, they should be punped out now. 1 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out aithin the last three years, they should be p�rnped out now. DRAINFIELD CONDITION C11-14): Dr,a�field inspection indicates: (1Y Drainfield is dry, no surfacing evident. `f2 Same evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfietd extent and condition unknown. LlMIT1NG SITE FACTORS (sloae,setbacks.etc.): POTENTIAL fOR SYSTEM fA1LURE (deoends on soils.water table,etc.): COMMENTS: Date of Inspection ep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opim on of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the premises with the system loc�tion and punping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAf;E TREA'1'b�NT � �, INSPECTION REPORT ti ��9x'Esxo4`'�c, Owner: ,C�✓L�)I J+lC�F�CG✓L�1� Address: �rVJ �////1"�ii�lr ICG�. Permit �'a: Dates: — g � �-�/ Contractors:['Y�I9P /7Ayt'��. ���'F�tF+��DY� City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is §�an existing system [ l new construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and ahich is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting sotl characteristics. (The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.> TANK CONDITION (5-10): Tank inspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharye. 9 Inspection risers missing-tanks could not be inspected. [nspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been punped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D field inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 73 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS Cslope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /� r COMMENTS: Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner