Loading...
HomeMy WebLinkAboutseptic info 4 .q,. '��Rw. A�5:�5 '�k��. . ����b ��^ ��` � � � CITY of ORONO ,������: .c3tYlY.' �a"s°�5+�: " R e '�e'; �ae Post Office Box 66•Crystal Bay,Minnesota 55323•Municipal Offices • i � '� �` On the North Shore of Lake Minnetonka February 8 , 1989 Duane Ritter Excavating 7120 Vernon Street Rockford, MN 55373 RE: Septic System As-Built 1840 Shoreline Drive (1910 Heritage Drive) Dear Duane: In going through my open files, I find for the above-referenced property owned by James W. Marshall, an inspection slip from Lyle Oman indicating you were to measure ties from the tanks and drainfield to the house and submit those ties. If you have a record of those measurements , please submit them to this office. Thank you for your attention to this matter. Sincerely, , , � � 'i�- Michael P. G ffron Asst. Planning & Zoning Admin. MPG/ls cc: Mr. Lyle Oman BUILDING&ZONINC—473-7357 • ADMINISTRATION&FINANCE—473-7358 • PUBLIC WORKS—473-7359 ASSESSING � - .SEPTIC .SY.STEM INVENTORY Address: 1910Heritage Dr. PID: 10-1 17-23 42 0003 Building Type: residence #BRs/GPD: 4 #Systems 1 Units Billed 1 Permit#: 352 Date of Permit: 10/21/87 Installer: Ritter System Type mound Experimental: no Appliances lndry,dshw SYSTEM CONDITION Conformity: 1 Tank Condition: 8 DF condition: 11 Failure Pot: low .SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000, 1000 Setback to Bldg: 20 Cesspool: no DRAINFIELD Length of Lines 150 #Lines: 3 Trench Width: 10 Treatment Area: 80*41 Type of Filter rock,clean sand Soil Boring: yes Tile Size: 1.5 Under Tile 9 Perc Rate: 9.1 Setback DF-Bldg: 100 DF Ht above Wt: 3 Soil Type: loam,clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 100 Well-DF: 100 Report in File: y Pump Type: subm. Depth: 229 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 11/20/87 installation 1 7/18/90 no surfacing 1 10/2/92 no surfacing 1 6/13/94 no surfacing-pump tanks 1 4/13/98 no surfacing-need risers, pump tanks 1 � �����r � \ �� ���a �(',�l/4 � L�'� � � � . ���11 ' . ` , ,- - - - , . , � V `Q - - - � �--, i . \ — i i � � , � I I \ ' � � � ' ! � I � � O��(� - - - -� � ` � � I \ �`c��,(L� 5 � I I � � ' � (�� i k.Or '- - - -, ! J I � P�` � I � � � /� � - +'t' � i 1 i � - - - -f- � l �-- - � 4 � � Ga�. �- - — .. A g c D T, l00'3' ��' , T- Iog' `�l . �o � - ,X, � 16q' „ �� T3 ias I,�� � �,' s°�6 � o� ,; O �,, O �' � ����r��,� ,� CITY of ORONO � ��� � � ��^"��' !4 Munici al Offices `�n �� �'��� r°. P r.��� i��.'�'+4 '�' �.� �9 L'"����b���� Street Address: Mailing Address: `qjfE g HO�' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: L0111S BI.00�'1 Address: 1910 Heritage Dr. Permit #'s: 352 Dates: 10/21/87 Contractors: Ritter (This is [ ] an existing system [ � new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil leval is [ ] or is not [ ] idantified under this septic system. If the saturated soil lavel is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 The tank or tanks meet the definition of a cesspool and must be replaced within 10 months. (The tanks are ( ] or are aot [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed to be watertight, this classification is subject to ravision.) DRAINFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: 4/13/9 8 _i���t-C W�z-c%�fiYi�'� �? Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT � � INSPECTION REPORT ti ���kESHO�'�G � ��Owner• �� y �� Address• Permit �'s: � Dates: ��—����7 Contractors: /'Ci�� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. 7he on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �} an existing system [ ] new construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current C1ty Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current seuage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soit or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: ,5� Pwnpout not needet! at this time. Z.b� s indicates e m t t is ear to hel e le 7 Solids accumulation in tan s is at a critical evel. an s s ou e pumpe out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purt�out. If tanks have not been pumped out within the last three years, they should be purnped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). !f tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr field inspection indicates: 1 Drainfie[d is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City ]nspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTlAL FOR SYSTEM FAILURE (depends on soils,Water table,etc.): �n, 1 ��n. COMMENTS: Date of nspection S ic S stem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certtfy that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O ;� O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT „� � INSPECTION REPORT ti ���kESH��'�G Owner: � � ►G%/�. Address: �/�!J f7t'/�TU4E'� /ll:� Permit #'s: �� Dates: /�;,Z/=�,� Contractors: ICi /I�Y �XC:+ City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked belou. (This is [�j. an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): � 1 "CODE SYS7EM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): � T inspection indicates: 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 5olids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been purnped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr field insPection indicates: 1�Drainfield is dry, no surfacing evident. rz Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): !�� ! POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �� COMMENTS: Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner